Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Int Heart J ; 59(1): 226-228, 2018 Jan 27.
Article in English | MEDLINE | ID: mdl-29279534

ABSTRACT

This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.


Subject(s)
Cardiac Catheterization/methods , Device Removal/methods , Embolism/surgery , Heart Septal Defects, Atrial/surgery , Septal Occluder Device/adverse effects , Angiography , Echocardiography, Transesophageal , Embolism/diagnosis , Embolism/etiology , Heart Septal Defects, Atrial/diagnosis , Humans , Male , Middle Aged , Prosthesis Failure , Reoperation
2.
Catheter Cardiovasc Interv ; 88(2): 193-200, 2016 Aug.
Article in English | MEDLINE | ID: mdl-26423017

ABSTRACT

OBJECTIVES: To assess the safety and efficacy of fractional flow reserve (FFR) guided paclitaxel-coated balloon (PCB) treatment for de novo coronary artery lesions. BACKGROUND: There is limited data on PCB treatment for de novo lesions especially of major epicardial coronary arteries. METHODS: Sixty-six patients with 67 de novo lesions who underwent successful plain old balloon angioplasty (POBA) were included. If POBA-FFR was favorable (≥ 0.85), PCB was applied and if POBA-FFR was <0.85, stent implantation was preferred over PCB. RESULTS: Forty-five lesions were treated with PCB (67.2%) and 22 lesions with stents (32.8%). Dual antiplatelet therapy duration was 6 weeks. Late luminal loss with PCB was significantly less than stent (0.05 ± 0.27 mm vs. 0.40 ± 0.54 mm, P = 0.022). The baseline FFR of target lesions was 0.69 ± 0.16 in PCB and 0.60 ± 0.11 in stent group (P = 0.015), however, the FFR at 9 months was not different between groups (0.85 ± 0.08 in PCB vs. 0.85 ± 0.05 in stent group, P = 0.973). At 1 year, one myocardial infarction and one target lesion revascularization related to in-stent restenosis were detected, both in the stent group. CONCLUSION: POBA-FFR-guided PCB treatment is safe and effective for de novo coronary lesions with good anatomical and physiological patency at mid-term follow-up. © 2015 Wiley Periodicals, Inc.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheters , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Coronary Vessels/drug effects , Drug-Eluting Stents , Fractional Flow Reserve, Myocardial/drug effects , Paclitaxel/administration & dosage , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/adverse effects , Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Coronary Restenosis/etiology , Coronary Vessels/physiopathology , Drug Therapy, Combination , Equipment Design , Female , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Paclitaxel/adverse effects , Platelet Aggregation Inhibitors/administration & dosage , Predictive Value of Tests , Prospective Studies , Registries , Republic of Korea , Time Factors , Treatment Outcome , Vascular Patency/drug effects
3.
Heart Vessels ; 31(11): 1767-1775, 2016 Nov.
Article in English | MEDLINE | ID: mdl-26874947

ABSTRACT

There is limited research on plaque characteristics of ST elevation myocardial infarction (STEMI) patients according to the gender and age. 280 Consecutive STEMI patients who underwent VH-IVUS imaging on culprit before percutaneous coronary intervention (PCI) were enrolled in this study. Women were significantly older than men (69.8 ± 10 vs. 55.9 ± 11.3, p < 0.001). After propensity matching, men had higher plaque burden (79.7 ± 7.8 vs. 73.7 ± 13.0 %, p = 0.010), more fibro-fatty tissue (12.8 ± 9.9 vs. 9.5 ± 6.8 %, p = 0.04) and less dense calcium than women (8.4 ± 5.8 vs. 12.3 ± 8.7 %, p = 0.007). Subgroups dividing by 50, 65, 75 years old, plaque burden was higher in elderly men aged 66-75 years compared to the young men aged less than 50 (75.5 ± 9.2 vs. 68.4 ± 10.1 %, p = 0.012). And middle aged men ranged 51-65 years showed significantly more plaque burden at minimal lumen area site than matched aged women (77.5 ± 8.0 vs. 69.0 ± 17.6 %, p = 0.012). Elderly women aged 66-75 years showed significantly more necrotic core (28.6 ± 7.3 %) and dense calcium (14.9 ± 7.5 %) compared to all the younger or matched subgroups of men. These differences in plaque composition are blunted in the very elderly of men and women aged over 75 years. The findings may explain the gender differences in clinical prognosis in STEMI patients.


Subject(s)
Coronary Artery Disease/pathology , Coronary Vessels/pathology , Health Status Disparities , Plaque, Atherosclerotic , ST Elevation Myocardial Infarction/etiology , Age Factors , Aged , Chi-Square Distribution , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/diagnostic imaging , Coronary Vessels/diagnostic imaging , Female , Fibrosis , Humans , Logistic Models , Male , Middle Aged , Necrosis , Predictive Value of Tests , Prognosis , Propensity Score , Registries , Risk Factors , Rupture, Spontaneous , ST Elevation Myocardial Infarction/diagnostic imaging , Sex Factors , Ultrasonography, Interventional , Vascular Calcification/diagnostic imaging , Vascular Calcification/pathology
4.
Heart Vessels ; 30(2): 162-8, 2015 Mar.
Article in English | MEDLINE | ID: mdl-24481539

ABSTRACT

Optical coherence tomography (OCT) has a sufficiently high resolution to allow assessment of stent edge dissection (ED). The aims of the present study were as follows: (1) evaluation of the frequency of stent ED using OCT; (2) comparison of stent ED detection rates obtained using angiography, intravascular ultrasound (IVUS), and OCT; and (3) IVUS-Virtual Histology (IVUS-VH) evaluation of plaque composition at the site of stent EDs detected by OCT after percutaneous coronary intervention (PCI). Fifty-eight consecutive patients (59 lesions, 100 stent edges) who underwent balloon-expandable stent implantation and post-stent assessment with OCT and IVUS-VH were included. OCT revealed stent ED in 24.0 % (24 of 100) of stent edges after PCI with a balloon-expandable stent. In contrast, ED was detected in only 3.0 % (3 of 100) of stent edges using angiography and 4.0 % (4 of 100) of stent edges using IVUS. Plaque evaluation using IVUS-VH showed that the percent necrotic core (21.2 ± 8.3 vs. 13.4 ± 10.7 %, p = 0.001) and absolute dense calcium (2.9 ± 2.4 vs. 1.3 ± 2.2 mm(3), p = 0.0104) and dense calcium (13.8 ± 9.3 vs. 5.4 ± 5.8 %, p < 0.001) volumes were greater in the ED group than in the non-ED group. Thus, OCT is superior to conventional coronary angiography and IVUS in the identification of stent ED. In addition, the plaque composition at the ED site is characterized by a necrotic core and greater dense calcium levels than those observed at the non-ED site.


Subject(s)
Coronary Angiography , Coronary Artery Disease/therapy , Coronary Vessels , Multimodal Imaging/methods , Percutaneous Coronary Intervention/instrumentation , Stents , Tomography, Optical Coherence , Ultrasonography, Interventional , Aged , Coronary Artery Disease/diagnosis , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Female , Humans , Male , Middle Aged , Necrosis , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Retrospective Studies , Treatment Outcome , Vascular Calcification/diagnosis , Vascular Calcification/therapy
5.
PLoS One ; 11(1): e0147057, 2016.
Article in English | MEDLINE | ID: mdl-26824602

ABSTRACT

AIMS: To assess the serial changes of de novo coronary lesions treated with paclitaxel-coated balloon (PCB) using intravascular ultrasound virtual histology (IVUS-VH) and fractional flow reserve (FFR). METHOD AND RESULTS: This prospective observational study enrolled 27 patients with coronary artery disease treated with PCB who underwent coronary angiography, IVUS-VH and FFR before, immediately after intervention and at 9 months. 28 de novo lesions were successfully treated with PCB. Angiographic late luminal loss was 0.02 ± 0.27 mm. Mean vessel and lumen areas showed increase at 9 months (12.0 ± 3.5 mm(2) to 13.2 ± 3.9 mm(2), p <0.001; and 5.4 ± 1.2 mm(2) to 6.5 ± 1.8 mm(2), p <0.001, respectively). Although mean plaque area was unchanged (6.6 ± 2.6 mm2 to 6.6 ± 2.4 mm(2), p = 0.269), percent atheroma volume decreased significantly (53.4 ± 7.9% to 49.5 ± 6.4%, p = 0.002). The proportion of plaque compositions including fibrous, fibrofatty, dense calcium and necrotic core by IVUS-VH was unchanged at 9 months. The FFR of the treated lesion was 0.71 ± 0.13 pre-procedure, 0.87 ± 0.06 post-procedure and 0.84 ± 0.06 at follow-up. CONCLUSIONS: De novo coronary lesions treated with PCB showed persistent anatomical and physiological patency with plaque redistribution and vessel remodeling without chronic elastic recoil or plaque compositional change during follow-up.


Subject(s)
Angioplasty, Balloon, Coronary/methods , Coronary Artery Disease/surgery , Coronary Vessels/surgery , Fractional Flow Reserve, Myocardial/physiology , Plaque, Atherosclerotic/surgery , Aged , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/pathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Female , Humans , Male , Middle Aged , Paclitaxel , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/pathology , Prospective Studies , Ultrasonography, Interventional
6.
JACC Cardiovasc Imaging ; 8(9): 1059-1067, 2015 Sep.
Article in English | MEDLINE | ID: mdl-26298073

ABSTRACT

OBJECTIVES: The aim of this study was to define the morphological features of coronary artery spasm sites using optical coherence tomography (OCT) in patients with vasospastic angina (VSA). BACKGROUND: Plaque characteristics at coronary artery spasm sites have not been investigated systematically. METHODS: Sixty-nine consecutive patients (80 spasm sites) presenting with VSA who underwent OCT imaging were included in this study. Fibrous cap disruption was identified by the discontinuation of fibrous cap with or without intraplaque cavity formation. OCT-defined erosion was established by the presence of thrombus with or without lumen irregularity overlying an intact fibrous cap on multiple adjacent OCT frames. Other morphological features such as the absence of thrombus with or without lumen irregularity and those not in the previously mentioned criteria were also documented. RESULTS: Plaque was seen on OCT in 79 of the 80 spasm sites. Fibrous cap disruption was detected at 3 sites (4%). OCT-defined erosion was observed at 21 spasm sites (26%). Thrombus with lumen irregularity was observed in 20 sites, whereas 1 site had thrombus without lumen irregularity. Lumen irregularity without thrombus was observed at 49 spasm sites (61%). Spontaneous spasm was seen more frequently in patients with acute myocardial infarction and out-of-hospital cardiac arrest than in patients without these conditions (50.0% vs. 19.3%, p = 0.025). CONCLUSIONS: Our results show that OCT-defined erosion at spasm sites occurred in more than one-fourth of patients in this study. Luminal irregularity was observed in nearly two-thirds of the patients without overlying thrombus. These findings suggest the potential role of antiplatelet therapy in VSA.


Subject(s)
Angina Pectoris/pathology , Coronary Thrombosis/pathology , Coronary Vasospasm/pathology , Coronary Vessels/pathology , Myocardial Infarction/pathology , Out-of-Hospital Cardiac Arrest/pathology , Plaque, Atherosclerotic , Tomography, Optical Coherence , Angina Pectoris/diagnostic imaging , Coronary Angiography , Coronary Thrombosis/diagnostic imaging , Coronary Vasospasm/diagnostic imaging , Coronary Vessels/diagnostic imaging , Female , Fibrosis , Humans , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Out-of-Hospital Cardiac Arrest/diagnostic imaging , Predictive Value of Tests , Republic of Korea
7.
J Korean Med Sci ; 24 Suppl: S109-14, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19194538

ABSTRACT

Vitamin D insufficiency may be associated with cardiovascular (CV) mortality in HD patients. To test this hypothesis, we cross-sectionally measured 25-hydroxyvitamin D (25D), 1,25-dihydroxyvitamin D (1,25D), cardiac troponin T (cTnT), and N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) in chronic HD patients. Sixty-five patients (M:F=31:34, age 52.2+/-13.2 yr, DM 41.5%) were selected. Along with the expected low levels of 1,25D, 59 (90.8%) patients had 25D insufficiency (<30 ng/mL) among whom 15 (23.1%) were 25D deficient (<10 ng/mL). The 25D levels showed a negative correlation with cTnT levels (Spearman's rho=-0.44, p<0.01) but not with NT-pro-BNP levels (Spearman's rho=-0.17, p=0.17). The 1,25D levels, however, did not show any relationship with either cTnT or NT-pro-BNP. In multivariate analysis, being male and having low levels of 25D were independent risk factors associated with cTnT elevation (beta=0.44, p<0.01 and beta=-0.48, p<0.01, respectively). In conclusion, not only 1,25D but also 25D are commonly decreased in HD patients. Lower 25D levels appear to be associated with cTnT elevation, predicting worse CV outcome, and are possible to involve cardiac hypertrophy or coronary artery disease.


Subject(s)
Biomarkers/blood , Heart Diseases/blood , Renal Dialysis/methods , Vitamin D/blood , Coronary Artery Disease/blood , Coronary Artery Disease/diagnosis , Electrocardiography/methods , Female , Heart Diseases/diagnosis , Humans , Male , Middle Aged , Multivariate Analysis , Natriuretic Peptide, Brain , Nerve Tissue Proteins/blood , Protein Precursors/blood , Risk Factors , Troponin T/blood , Vitamin D/metabolism