Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 368
Filter
Add more filters

Publication year range
1.
Annu Rev Physiol ; 83: 83-106, 2021 02 10.
Article in English | MEDLINE | ID: mdl-33064962

ABSTRACT

Atrial fibrillation (AF) contributes to morbidity and mortality of millions of individuals. Its molecular, cellular, neurohumoral, and hemodynamic pathophysiological mechanisms are complex, and there is increasing awareness that a wide range of comorbidities can contribute to AF-promoting atrial remodeling. Moreover, recent research has highlighted that AF risk is not constant and that the temporal variation in concomitant conditions contributes to the complexity of AF dynamics. In this review, we provide an overview of fundamental AF mechanisms related to established and emerging comorbidities or risk factors and their role in the AF-promoting effects. We focus on the accumulating evidence for the relevance of temporally dynamic changes in these risk factors and the consequence for AF initiation and maintenance. Finally, we highlight the important implications for future research and clinical practice resulting from the dynamic interaction between AF risk factors and mechanisms.


Subject(s)
Atrial Fibrillation/pathology , Animals , Comorbidity , Humans , Risk Factors
2.
Circ Res ; 130(6): 814-828, 2022 03 18.
Article in English | MEDLINE | ID: mdl-35130718

ABSTRACT

BACKGROUND: In patients with chronic kidney disease (CKD), atrial fibrillation (AF) is highly prevalent and represents a major risk factor for stroke and death. CKD is associated with atrial proarrhythmic remodeling and activation of the sympathetic nervous system. Whether reduction of the sympathetic nerve activity by renal denervation (RDN) inhibits AF vulnerability in CKD is unknown. METHODS: Left atrial (LA) fibrosis was analyzed in samples from patients with AF and concomitant CKD (estimated glomerular filtration rate [eGFR], <60 mL/min per 1.73 m2) using picrosirius red and compared with AF patients without CKD and patients with sinus rhythm with and without CKD. In a translational approach, male Sprague Dawley rats were fed with 0.25% adenine (AD)-containing chow for 16 weeks to induce CKD. At week 5, AD-fed rats underwent RDN or sham operation (AD). Rats on normal chow served as control. After 16 weeks, cardiac function and AF susceptibility were assessed by echocardiography, radiotelemetry, electrophysiological mapping, and burst stimulation, respectively. LA tissue was histologically analyzed for sympathetic innervation using tyrosine hydroxylase staining, and LA fibrosis was determined using picrosirius red. RESULTS: Sirius red staining demonstrated significantly increased LA fibrosis in patients with AF+CKD compared with AF without CKD or sinus rhythm. In rats, AD demonstrated LA structural changes with enhanced sympathetic innervation compared with control. In AD, LA enlargement was associated with prolonged duration of induced AF episodes, impaired LA conduction latency, and increased absolute conduction inhomogeneity. RDN treatment improved LA remodeling and reduced LA diameter compared with sham-operated AD. Furthermore, RDN decreased AF susceptibility and ameliorated LA conduction latency and absolute conduction inhomogeneity, independent of blood pressure reduction and renal function. CONCLUSIONS: In an experimental rat model of CKD, RDN inhibited progression of atrial structural and electrophysiological remodeling. Therefore, RDN represents a potential therapeutic tool to reduce the risk of AF in CKD, independent of changes in renal function and blood pressure.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Renal Insufficiency, Chronic , Animals , Atrial Fibrillation/etiology , Atrial Fibrillation/prevention & control , Denervation , Female , Fibrosis , Humans , Kidney/pathology , Male , Rats , Rats, Sprague-Dawley , Renal Insufficiency, Chronic/complications
3.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38758963

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the corner stone of modern rhythm control strategies in patients with atrial fibrillation (AF). Sleep-disordered breathing (SDB) is prevalent in more than 50% of patients undergoing AF ablation, and studies have indicated a greater recurrence rate after PVI in patients with SDB. Herein, we study the effect of catheter-based PVI on AF in a pig model for SDB. METHODS AND RESULTS: In 11 sedated spontaneously breathing pigs, obstructive apnoeas were simulated by 75 s of intermittent negative upper airway pressure (INAP) applied by a negative pressure device connected to the endotracheal tube. Intermittent negative upper airway pressures were performed before and after PVI. AF-inducibility and atrial effective refractory periods (aERPs) were determined before and during INAP by programmed atrial stimulation. Pulmonary vein isolation prolonged the aERP by 48 ± 27 ms in the right atrium (RA) (P < 0.0001) and by 40 ± 34 ms in the left atrium (LA) (P = 0.0004). Following PVI, AF-inducibility dropped from 28 ± 26% to 0% (P = 0.0009). Intermittent negative upper airway pressure was associated with a transient aERP-shortening (ΔaERP) in both atria, which was not prevented by PVI (INAP indued ΔaERP after PVI in the RA: -57 ± 34 ms, P = 0.0002; in the LA: -42 ± 24 ms, P < 0.0001). Intermittent negative upper airway pressure was associated with a transient increase in AF-inducibility (from 28 ± 26% to 69 ± 21%; P = 0.0008), which was not attenuated by PVI [INAP-associated AF-inducibility after PVI: 58 ± 33% (P = 0.5)]. CONCLUSION: Transient atrial arrhythmogenic changes related to acute obstructive respiratory events are not prevented by electrical isolation of the pulmonary veins, which partially explains the increased AF recurrence in patients with SDB after PVI procedures.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Disease Models, Animal , Pulmonary Veins , Animals , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Atrial Fibrillation/physiopathology , Atrial Fibrillation/surgery , Atrial Fibrillation/prevention & control , Atrial Fibrillation/diagnosis , Swine , Catheter Ablation/methods , Sleep Apnea, Obstructive/physiopathology , Treatment Failure , Heart Rate , Heart Atria/physiopathology , Heart Atria/surgery
4.
Europace ; 26(7)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38885309

ABSTRACT

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Subject(s)
Defibrillators, Implantable , Electric Power Supplies , Registries , Humans , Male , Female , Middle Aged , Retrospective Studies , Aged , United States/epidemiology , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/epidemiology , Europe/epidemiology , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Equipment Failure/statistics & numerical data , Time Factors , Equipment Failure Analysis/statistics & numerical data , Adult
5.
Europace ; 26(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38861398

ABSTRACT

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Subject(s)
Defibrillators, Implantable , Electric Countershock , Registries , Humans , Male , Retrospective Studies , Female , Middle Aged , Incidence , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Aged , Europe/epidemiology , Equipment Failure/statistics & numerical data , United States/epidemiology , Risk Factors
6.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38591838

ABSTRACT

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Stroke/etiology , Stroke/prevention & control , Risk , Hemorrhage , Anticoagulants/therapeutic use
7.
J Electrocardiol ; 84: 129-136, 2024.
Article in English | MEDLINE | ID: mdl-38663227

ABSTRACT

BACKGROUND: The association between type 2 diabetes and electrocardiographic (ECG) markers are incompletely explored and the dependence on diabetes duration is largely unknown. We aimed to investigate the electrocardiographic (ECG) changes associated with type 2 diabetes over time. METHODS: In this cross-sectional study, we matched people with type 2 diabetes 1:1 on sex, age, and body mass index with people without diabetes from the general population. We regressed ECG markers with the presence of diabetes and the duration of clinical diabetes, respectively, adjusted for sex, age, body mass index, smoking, heart rate, diabetes medication, renal function, hypertension, and myocardial infarction. RESULTS: We matched 988 people with type 2 diabetes (332, 34% females) with as many controls. Heart rate was 8 bpm higher (p < 0.001) in people with vs. without type 2 diabetes, but the difference declined with increasing diabetes duration. For most depolarization markers, the difference between people with and without type 2 diabetes increased progressively with diabetes duration. On average, R-wave amplitude was 6 mm lower in lead V5 (p < 0.001), P-wave duration was 5 ms shorter (p < 0.001) and QRS duration was 3 ms (p = 0.03). Among repolarization markers, T-wave amplitude (measured in V5) was lower in patients with type 2 diabetes (1 mm lower, p < 0.001) and the QRS-T angle was 10 degrees wider (p = 0.002). We observed no association between diabetes duration and repolarization markers. CONCLUSIONS: Type 2 diabetes was independently associated with electrocardiographic depolarization and repolarization changes. Differences in depolarization markers, but not repolarization markers, increased with increasing diabetes duration.


Subject(s)
Diabetes Mellitus, Type 2 , Electrocardiography , Humans , Diabetes Mellitus, Type 2/physiopathology , Diabetes Mellitus, Type 2/complications , Female , Male , Middle Aged , Cross-Sectional Studies , Aged , Sensitivity and Specificity , Biomarkers/blood , Reproducibility of Results , Heart Rate
8.
Eur Heart J ; 44(27): 2458-2469, 2023 Jul 14.
Article in English | MEDLINE | ID: mdl-37062040

ABSTRACT

AIMS: Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS: This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION: Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophageal Fistula , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnosis , Treatment Outcome , Incidence , Risk Factors , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology , Esophageal Fistula/diagnosis , Prognosis , Catheter Ablation/adverse effects , Catheter Ablation/methods
9.
Neth Heart J ; 32(3): 130-139, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38214880

ABSTRACT

AIM: To evaluate changes in healthcare utilisation and comprehensive packages of care activities and procedures (referred in the Netherlands to as 'diagnose-behandelcombinatie (DBC) care products) during the implementation of the TeleCheck-AF approach (teleconsultation supported by app-based heart rate/rhythm monitoring) in a Dutch atrial fibrillation (AF) clinic. METHODS AND RESULTS: In the Maastricht University Medical Centre+ AF Clinic, data on healthcare utilisation and DBC care products for patients consulted by both a conventional approach in 2019 and the TeleCheck-AF approach in 2020 were analysed. A patient experience survey was performed. Thirty-seven patients (median age 68 years; 40% women) were analysed. With the conventional approach, 35 face-to-face consultations and 0 teleconsultations were conducted. After the implementation of TeleCheck-AF, the number of face-to-face consultations dropped by 80% (p < 0.001) and teleconsultations increased to 45 (p < 0.001). While 42 electrocardiograms (ECGs) and 25 Holter ECGs or echocardiograms were recorded when using the conventional approach, the number of ECGs decreased by 71% (p < 0.001) and Holter ECGs or echocardiograms by 72% (p < 0.001) with the TeleCheck-AF approach. The emergency department patient presentations showed no statistically significant change (p = 0.33). Overall, 57% of medium-weight DBC care products were changed to light-weight ones during implementation of the TeleCheck-AF approach. Patient satisfaction with the TeleCheck-AF approach was high. CONCLUSION: The implementation of TeleCheck-AF led to a change in healthcare utilisation, a change from medium-weight to light-weight DBC care products and a reduction in patient burden. These results created the basis for a new reimbursement code for the TeleCheck-AF approach in the Netherlands.

10.
Circulation ; 146(9): e119-e136, 2022 08 30.
Article in English | MEDLINE | ID: mdl-35912643

ABSTRACT

Sleep-disordered breathing (SDB), characterized by specific underlying physiological mechanisms, comprises obstructive and central pathophysiology, affects nearly 1 billion individuals worldwide, and is associated with excessive cardiopulmonary morbidity. Strong evidence implicates SDB in cardiac arrhythmogenesis. Immediate consequences of SDB include autonomic nervous system fluctuations, recurrent hypoxia, alterations in carbon dioxide/acid-base status, disrupted sleep architecture, and accompanying increases in negative intrathoracic pressures directly affecting cardiac function. Day-night patterning and circadian biology of SDB-induced pathophysiological sequelae collectively influence the structural and electrophysiological cardiac substrate, thereby creating an ideal milieu for arrhythmogenic propensity. Cohort studies support strong associations of SDB and cardiac arrhythmia, with evidence that discrete respiratory events trigger atrial and ventricular arrhythmic events. Observational studies suggest that SDB treatment reduces atrial fibrillation recurrence after rhythm control interventions. However, high-level evidence from clinical trials that supports a role for SDB intervention on rhythm control is not available. The goals of this scientific statement are to increase knowledge and awareness of the existing science relating SDB to cardiac arrhythmias (atrial fibrillation, ventricular tachyarrhythmias, sudden cardiac death, and bradyarrhythmias), synthesizing data relevant for clinical practice and identifying current knowledge gaps, presenting best practice consensus statements, and prioritizing future scientific directions. Key opportunities identified that are specific to cardiac arrhythmia include optimizing SDB screening, characterizing SDB predictive metrics and underlying pathophysiology, elucidating sex-specific and background-related influences in SDB, assessing the role of mobile health innovations, and prioritizing the conduct of rigorous and adequately powered clinical trials.


Subject(s)
Atrial Fibrillation , Sleep Apnea Syndromes , Tachycardia, Ventricular , Adult , American Heart Association , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Autonomic Nervous System , Female , Humans , Male , Sleep Apnea Syndromes/complications , Sleep Apnea Syndromes/diagnosis , Sleep Apnea Syndromes/epidemiology , Tachycardia, Ventricular/complications
11.
J Cardiovasc Electrophysiol ; 34(1): 126-134, 2023 01.
Article in English | MEDLINE | ID: mdl-36482155

ABSTRACT

BACKGROUND: Obstructive sleep apnea (OSA) creates a complex substrate for atrial fibrillation (AF), which is refractory to many clinically available pharmacological interventions. We investigated atrial antiarrhythmogenic properties and ventricular electrophysiological safety of small-conductance Ca2+ -activated K+ (SK)-channel inhibition in a porcine model for obstructive respiratory events. METHODS: In spontaneously breathing pigs, obstructive respiratory events were simulated by intermittent negative upper airway pressure (INAP) applied via a pressure device connected to the intubation tube. INAP was applied for 75 s, every 10 min, three times before and three times during infusion of the SK-channel inhibitor AP14145. Atrial effective refractory periods (AERP) were acquired before (pre-INAP), during (INAP) and after (post-) INAP. AF-inducibility was determined by a S1S2 atrial pacing protocol. Ventricular arrhythmicity was evaluated by heart rate adjusted QT-interval duration (QT-paced) and electromechanical window (EMW) shortening. RESULTS: During vehicle infusion, INAP transiently shortened AERP (pre-INAP: 135 ± 10 ms vs. post-INAP 101 ± 11 ms; p = .008) and increased AF-inducibility. QT-paced prolonged during INAP (pre-INAP 270 ± 7 ms vs. INAP 275 ± 7 ms; p = .04) and EMW shortened progressively throughout INAP and post-INAP (pre-INAP 80 ± 4 ms; INAP 59 ± 6 ms, post-INAP 46 ± 10 ms). AP14145 prolonged baseline AERP, partially prevented INAP-induced AERP-shortening and reduced AF-susceptibility. AP14145 did not alter QT-paced at baseline (pre-AP14145 270 ± 7 ms vs. AP14145 268 ± 6 ms, p = .83) or QT-paced and EMW-shortening during INAP. CONCLUSION: In a pig model for obstructive respiratory events, the SK-channel-inhibitor AP14145 prevented INAP-associated AERP-shortening and AF-susceptibility without impairing ventricular electrophysiology. Whether SK-channels represent a target for OSA-related AF in humans warrants further study.


Subject(s)
Atrial Fibrillation , Sleep Apnea, Obstructive , Humans , Swine , Animals , Atrial Fibrillation/prevention & control , Acetamides
12.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37622591

ABSTRACT

This reviews the transition of remote monitoring of patients with cardiac electronic implantable devices from curiosity to standard of care. This has been delivered by technology evolution from patient-activated remote interrogations at appointed intervals to continuous monitoring that automatically flags clinically actionable information to the clinic for review. This model has facilitated follow-up and received professional society recommendations. Additionally, continuous monitoring has provided a new level of granularity of diagnostic data enabling extension of patient management from device to disease management. This ushers in an era of digital medicine with wider applications in cardiovascular medicine.


Subject(s)
Cardiovascular Agents , Humans , Electronics , Heart , Technology , Disease Management
13.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37682245

ABSTRACT

AIMS: This study aims to survey current educational experience and the individual requirements for electrophysiologists in training. METHODS AND RESULTS: The European Heart Rhythm Association (EHRA) e-Communication Committee and the Scientific Initiatives Committee prepared a questionnaire and distributed it via newsletters, Twitter, LinkedIn, and Facebook. The survey consisted of 22 questions collected on an individual basis anonymously. Two hundred and forty-three responders from 35 countries (32% female, age 38 ± 6 years old) completed the survey. This EHRA electrophysiology (EP) fellowship survey showed that (i) hands-on participation and observation of EP procedures are very important; (ii) the main motivations to choose the EP fellowship institution are centre reputation and volume as well as the availability of a structured EP fellowship programme; (iii) 59% passed the EHRA exam and 46% took a national certification exam; (iv) respondents are overall satisfied with their own fellowships, but there are areas of less confidence such as conduction system pacing implantation and cardiac resynchronization therapy implantation; (v) 78% of respondents performed research during their fellowship, (vi) the optimal duration of an EP fellowship should be at least 2 years; and (viii) doing fellowships abroad is beneficial, but significant obstacles exist. CONCLUSION: The results of this EHRA survey may help to refine current EP fellowship programmes to improve the quality of EP training and early career building of young electrophysiologists.


Subject(s)
Cardiac Resynchronization Therapy , Fellowships and Scholarships , Humans , Female , Adult , Male , Cardiac Conduction System Disease , Cardiac Electrophysiology , Certification
14.
Europace ; 25(3): 855-862, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36738261

ABSTRACT

AIMS: Evaluation of (i) the effects of a virtual reality (VR) preprocedural patient education video on information provision, procedure-related knowledge, satisfaction, and the level of worries in patients planned for atrial fibrillation (AF) ablation and (ii) the feasibility of a disposable cardboard VR viewer for home use in this setting. METHODS AND RESULTS: In this prospective observational cohort study, patients were alternatively assigned in a 1:1 ratio to the control or VR group. Controls received standard preprocedural information. VR group received standard information and a VR video (via in-hospital VR headset and disposable cardboard). The Amsterdam Preoperative Anxiety and Information Scale (APAIS) together with additional questions concerning procedural experience and satisfaction was completed pre- and post-ablation. Of 134 patients [38.1% female, aged 66 (58-72) years] included, 49.2% were assigned to the control and 50.7% to the VR group. The number of patients that worried about the ablation procedure was lower in VR than in control patients (19.1% vs. 40.9%, P = 0.006). More VR females than males had worries about the procedure (34.8% vs. 11.1%, P = 0.026). The number of VR patients that were satisfied with the preprocedural information provision was higher post-ablation than pre-ablation (83.3% vs. 60.4%, P = 0.007). In total, 59.4% reported that the disposable cardboard was easy to use and led to a discussion with relatives in 68.8%. CONCLUSION: In patients scheduled for AF ablation, a VR preprocedural educational video led to better information provision and procedure-related knowledge, higher satisfaction, and less worries regarding the procedure. The disposable cardboard was feasible for home use.


Subject(s)
Atrial Fibrillation , Virtual Reality , Male , Humans , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Prospective Studies , Patient Education as Topic , Anxiety/etiology , Anxiety/prevention & control
15.
Europace ; 25(3): 835-844, 2023 03 30.
Article in English | MEDLINE | ID: mdl-36748247

ABSTRACT

AIMS: Although mobile health tools using photoplethysmography (PPG) technology have been validated for the detection of atrial fibrillation (AF), their utility for heart rate assessment during AF remains unclear. Therefore, we aimed to evaluate the accuracy of continuous PPG-based 1 min mean heart rate assessment during AF. METHODS AND RESULTS: Persistent AF patients were provided with Holter electrocardiography (ECG) (for ≥24 h) simultaneously with a PPG-equipped smartwatch. Both the PPG-based smartwatch and Holter ECG automatically and continuously monitored patients' heart rate/rhythm. ECG and PPG recordings were synchronized and divided into 1 min segments, from which a PPG-based and an ECG-based average heart rate estimation were extracted. In total, 47 661 simultaneous ECG and PPG 1 min heart rate segments were analysed in 50 patients (34% women, age 73 ± 8 years). The agreement between ECG-determined and PPG-determined 1 min mean heart rate was high [root mean squared error (RMSE): 4.7 bpm]. The 1 min mean heart rate estimated using PPG was accurate within ±10% in 93.7% of the corresponding ECG-derived 1 min mean heart rate segments. PPG-based 1 min mean heart rate estimation was more often accurate during night-time (97%) than day-time (91%, P < 0.001) and during low levels (96%) compared to high levels of motion (92%, P < 0.001). A neural network with a 10 min history of the recording did not further improve the PPG-based 1 min mean heart rate assessment [RMSE: 4.4 (95% confidence interval: 3.5-5.2 bpm)]. Only chronic heart failure was associated with a lower agreement between ECG-derived and PPG-derived 1 min mean heart rates (P = 0.040). CONCLUSION: During persistent AF, continuous PPG-based 1 min mean heart rate assessment is feasible in 60% of the analysed period and shows high accuracy compared with Holter ECG for heart rates <110 bpm.


Subject(s)
Atrial Fibrillation , Humans , Female , Aged , Aged, 80 and over , Male , Atrial Fibrillation/diagnosis , Heart Rate , Photoplethysmography/methods , Electrocardiography/methods , Electrocardiography, Ambulatory , Algorithms
16.
Europace ; 25(7)2023 07 04.
Article in English | MEDLINE | ID: mdl-37421318

ABSTRACT

AIMS: Chronic obstructive pulmonary disease (COPD) negatively impacts the efficacy of heart rhythm control treatments in patients with atrial fibrillation (AF). Although COPD is recognized as a risk factor for AF, practical guidance about how and when to screen for COPD is not available. Herein, we describe the implementation of an integrated screening and management pathway for COPD into the existing pre-ablation work-up in an AF outpatient clinic infrastructure. METHODS AND RESULTS: Consecutive unselected patients accepted for AF catheter ablation in the Maastricht University Medical Center+ were prospectively screened for airflow limitation using handheld (micro)spirometry at the pre-ablation outpatient clinic supervised by an AF nurse. Patients with results suggestive of airflow limitation were offered referral to the pulmonologist. Handheld (micro)spirometry was performed in 232 AF patients, which provided interpretable results in 206 (88.8%) patients. Airflow limitation was observed in 47 patients (20.3%). Out of these 47 patients, 29 (62%) opted for referral to the pulmonologist. The primary reason for non-referral was low perceived symptom burden. Using this screening strategy 17 (out of 232; 7.3%) ultimately received a diagnosis of chronic respiratory disease, either COPD or asthma. CONCLUSION: A COPD care pathway can successfully be embedded in an existing AF outpatient clinic infrastructure, using (micro)spirometry and remote analysis of results. Although one out of five patients had results suggestive of an underlying chronic respiratory disease, only 62% of these patients opted for a referral. Pre-selection of patients as well as patient education might increase the diagnostic yield and requires further research.


Subject(s)
Atrial Fibrillation , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/complications , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/therapy , Lung , Risk Factors
17.
Europace ; 25(5)2023 05 19.
Article in English | MEDLINE | ID: mdl-36967470

ABSTRACT

AIMS: Atrial fibrillation (AF) progression is associated with adverse outcome, but the role of the circadian or diurnal pattern of AF onset remains unclear. We aim to assess the association between the time of onset of AF episodes with the clinical phenotype and AF progression in patients with self-terminating AF. METHODS AND RESULTS: The Reappraisal of AF: Interaction Between Hypercoagulability, Electrical Remodelling, and Vascular Destabilization in the Progression of AF study included patients with self-terminating AF who underwent extensive phenotyping at baseline and continuous rhythm monitoring with an implantable loop recorder (ILR). In this subanalysis, ILR data were used to assess the development of AF progression and the diurnal pattern of AF onset: predominant (>80%) nocturnal AF, predominant daytime AF, or mixed AF without a predominant diurnal AF pattern. The median follow-up was 2.2 (1.6-2.8) years. The median age was 66 (59-71) years, and 117 (42%) were women. Predominant nocturnal (n = 40) and daytime (n = 43) AF onset patients had less comorbidities compared to that of mixed (n = 195) AF patients (median 2 vs. 2 vs. 3, respectively, P = 0.012). Diabetes was more common in the mixed group (12% vs. 5% vs. 0%, respectively, P = 0.031), whilst obesity was more frequent in the nocturnal group (38% vs. 12% vs. 27%, respectively, P = 0.028). Progression rates in the nocturnal vs. daytime vs. mixed groups were 5% vs. 5% vs. 24%, respectively (P = 0.013 nocturnal vs. mixed and P = 0.008 daytime vs. mixed group, respectively). CONCLUSION: In self-terminating AF, patients with either predominant nocturnal or daytime onset of AF episodes had less associated comorbidities and less AF progression compared to that of patients with mixed onset of AF. CLINICAL TRIAL REGISTRATION: NCT02726698.


Subject(s)
Atrial Fibrillation , Female , Male , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Electrocardiography, Ambulatory/methods , Comorbidity , Time Factors
18.
Europace ; 25(4): 1323-1331, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36857318

ABSTRACT

AIMS: The recent 4S-AF (scheme proposed by the 2020 ESC AF guidelines to address stroke risk, symptom severity, severity of AF burden and substrate of AF to provide a structured phenotyping of AF patients in clinical practice to guide therapy and assess prognosis) scheme has been proposed as a structured scheme to characterize patients with atrial fibrillation (AF). We aimed to assess whether the 4S-AF scheme predicts AF progression in patients with self-terminating AF. METHODS AND RESULTS: We analysed 341 patients with self-terminating AF included in the well-phenotyped Reappraisal of Atrial Fibrillation: Interaction between HyperCoagulability, Electrical remodelling, and Vascular Destabilization in the Progression of AF (RACE V) study. Patients had continuous monitoring with implantable loop recorders or pacemakers. AF progression was defined as progression to persistent or permanent AF or progression of self-terminating AF with >3% burden increase. Progression of AF was observed in 42 patients (12.3%, 5.9% per year). Patients were given a score based on the components of the 4S-AF scheme. Mean age was 65 [interquartile range (IQR) 58-71] years, 149 (44%) were women, 103 (49%) had heart failure, 276 (81%) had hypertension, and 38 (11%) had coronary artery disease. Median CHA2DS2-VASc (the CHA2DS2-VASc score assesses thromboembolic risk. C, congestive heart failure/left ventricular dysfunction; H, hypertension; A2, age ≥ 75 years; D, diabetes mellitus; S2, stroke/transient ischaemic attack/systemic embolism; V, vascular disease; A, age 65-74 years; Sc, sex category (female sex)) score was 2 (IQR 2-3), and median follow-up was 2.1 (1.5-2.6) years. The average score of the 4S-AF scheme was 4.6 ± 1.4. The score points from the 4S-AF scheme did not predict the risk of AF progression [odds ratio (OR) 1.1 95% CI 0.88-1.41, C-statistic 0.53]. However, excluding the symptoms domain, resulting in the 3S-AF (4S-AF scheme without the domain symptom severity, only including stroke risk, severity of AF burden and substrate of AF) scheme, predicted the risk of progression (OR 1.59 95% CI 1.15-2.27, C-statistic 0.62) even after adjusting for sex and age. CONCLUSIONS: In self-terminating AF patients, the 4S-AF scheme does not predict AF progression. The 3S-AF scheme, excluding the symptom domain, may be a more appropriate score to predict AF progression. TRIAL REGISTRATION NUMBERS: Clinicaltrials.gov NCT02726698 for RACE V.


Subject(s)
Atrial Fibrillation , Heart Failure , Hypertension , Ischemic Attack, Transient , Stroke , Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Ischemic Attack, Transient/diagnosis , Ischemic Attack, Transient/epidemiology , Ischemic Attack, Transient/etiology , Risk Assessment/methods , Risk Factors , Stroke/diagnosis , Stroke/epidemiology , Stroke/etiology
19.
Europace ; 25(1): 6-27, 2023 02 08.
Article in English | MEDLINE | ID: mdl-35894842

ABSTRACT

Despite marked progress in the management of atrial fibrillation (AF), detecting AF remains difficult and AF-related complications cause unacceptable morbidity and mortality even on optimal current therapy. This document summarizes the key outcomes of the 8th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). Eighty-three international experts met in Hamburg for 2 days in October 2021. Results of the interdisciplinary, hybrid discussions in breakout groups and the plenary based on recently published and unpublished observations are summarized in this consensus paper to support improved care for patients with AF by guiding prevention, individualized management, and research strategies. The main outcomes are (i) new evidence supports a simple, scalable, and pragmatic population-based AF screening pathway; (ii) rhythm management is evolving from therapy aimed at improving symptoms to an integrated domain in the prevention of AF-related outcomes, especially in patients with recently diagnosed AF; (iii) improved characterization of atrial cardiomyopathy may help to identify patients in need for therapy; (iv) standardized assessment of cognitive function in patients with AF could lead to improvement in patient outcomes; and (v) artificial intelligence (AI) can support all of the above aims, but requires advanced interdisciplinary knowledge and collaboration as well as a better medico-legal framework. Implementation of new evidence-based approaches to AF screening and rhythm management can improve outcomes in patients with AF. Additional benefits are possible with further efforts to identify and target atrial cardiomyopathy and cognitive impairment, which can be facilitated by AI.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Artificial Intelligence , Early Diagnosis , Consensus , Cognition , Stroke/prevention & control
20.
Am Heart J ; 244: 36-41, 2022 02.
Article in English | MEDLINE | ID: mdl-34688651

ABSTRACT

Atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) are 2 cardiovascular conditions that often coexist. Strain phases of both the left and right atria are more impaired in paroxysmal AF patients with HFpEF than those without HFpEF in spite of comparable global longitudinal strain of the left ventricle. Atrial function may differentiate paroxysmal AF patients with HFpEF from those without HFpEF.


Subject(s)
Atrial Fibrillation , Heart Failure , Atrial Fibrillation/complications , Atrial Function , Heart Atria/diagnostic imaging , Heart Failure/complications , Humans , Stroke Volume
SELECTION OF CITATIONS
SEARCH DETAIL