Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Country/Region as subject
Language
Affiliation country
Publication year range
1.
Clin Exp Rheumatol ; 33(5): 617-23, 2015.
Article in English | MEDLINE | ID: mdl-26316061

ABSTRACT

OBJECTIVES: Infliximab (IFX) and adalimumab (ADL) drug levels and anti-drug antibodies (ADA) are assessed using a variety of techniques, therefore, results cannot accurately be compared for clinical purposes. The aim of this study was to test two infliximab (IFX) and adalimumab (ADL) ELISA versions, for drug levels and ADA, to see whether they yield similar results. METHODS: ELISA versions [Promonitor® IFX R1 and R2 (V.1), Promonitor® IFX and Anti-IFX (V.2); Promonitor® ADL R1 and R2 (V.1), Promonitor® ADL and Anti-ADL (V.2) kits (Progenika Biopharma, Spain)] were used to measure drug levels and ADA in IFX (n=24) and ADL (n=24) rheumatoid arthritis-treated patients in three independent laboratories. Quantitative and qualitative agreements were evaluated using intraclass correlation coefficients (ICC), and Cohen's Kappa (κ) respectively. The Bland-Altman plots assessed differences between V.1 and V.2. RESULTS: Interlaboratory agreement (ICC/κ) with V.1 was poor for IFX (0.66/0.62) and ADL (0.69/0.52) drug levels; meanwhile, high agreement was found with V.2 for IFX (0.98/0.95) and ADL (0.094/1.00). Comparison between V.1 and V.2 in each laboratory resulted in systematically higher values in V.2 than in V.1 and poor agreement (ICC/κ ranges) for IFX (0.12-0.7/ 0.19-0.42) and ADL (0.69-0.89 /0.50-0.73). CONCLUSIONS: Qualitative measurements result in better agreement, as evidenced in our study. Greater agreement in V.2 compared with V.1 for IFX and ADL levels could be due to a better tune up. Further studies are required to standardise methods to establish therapeutic reference ranges.


Subject(s)
Adalimumab/blood , Antirheumatic Agents/blood , Arthritis, Rheumatoid/blood , Drug Monitoring/standards , Enzyme-Linked Immunosorbent Assay/standards , Infliximab/blood , Laboratory Proficiency Testing/standards , Adalimumab/immunology , Antibodies/blood , Antirheumatic Agents/immunology , Arthritis, Rheumatoid/diagnosis , Arthritis, Rheumatoid/drug therapy , Arthritis, Rheumatoid/immunology , Cross-Sectional Studies , Humans , Infliximab/immunology , Observer Variation , Predictive Value of Tests , Quality Indicators, Health Care/standards , Reproducibility of Results , Spain , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL