Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Sensors (Basel) ; 24(7)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38610250

ABSTRACT

Optical interferometers are the main elements of interferometric sensing and measurement systems. Measuring their optical path difference (OPD) in real time and evaluating the measurement uncertainty are key to optimizing system noise and ensuring system consistency. With the continuous sinusoidal wavelength modulation of the laser, real-time OPD measurement of the main interferometer is achieved through phase comparison of the main and auxiliary interferometers. The measurement uncertainty of the main interferometer OPD is evaluated. It is the first evaluation of the impact of different auxiliary interferometer calibration methods on OPD measurements. A homodyne quadrature laser interferometer (HQLI) is used as the main interferometer, and a 3 × 3 interferometer is used as the auxiliary interferometer. The calibration of the auxiliary interferometer using optical spectrum analyzer scanning and ruler measurement is compared. The evaluation shows that the auxiliary interferometer is the most significant source of uncertainty and causes the total uncertainty to increase linearly with increasing OPD. It is proven that a high-precision calibration and large-OPD auxiliary interferometer can improve the real-time accuracy of OPD measurements based on the auxiliary interferometer. The scheme can determine the minimum uncertainty to optimize the system noise and consistency for vibration, hydroacoustic, and magnetic field measurements with OPDs of the ~m level.

2.
Sensors (Basel) ; 24(9)2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38732930

ABSTRACT

The temperature and strain fields monitoring during the preparation process of buoyancy materials, as well as the health status after molding, are important for mastering the mechanical properties of buoyancy materials and ensuring the safety of operators and equipment. This paper proposes a short and high-density femtosecond fiber Bragg grating (fs-FBG) array based on different temperature coefficients fibers. By optimizing the parameters of femtosecond laser point-by-point writing technology, high-performance fs-FBG arrays with millimeter level gating length and millimeter level spatial resolution were prepared on two types of fibers. These were successfully embedded in buoyancy materials to achieve in-situ online monitoring of the curing process and after molding. The experimental results show that the fs-FBG array sensor has good anti-chirp performance and achieves online monitoring of millimeter-level spatial resolution. Intelligent buoyancy materials can provide real-time feedback on the health status of equipment in harsh underwater environments. The system can achieve temperature monitoring with an accuracy of 0.56 °C and deformation monitoring with sub-millimeter accuracy; the error is in the order of micrometers, which is of great significance in the field of deep-sea exploration.

3.
Sensors (Basel) ; 23(5)2023 Feb 24.
Article in English | MEDLINE | ID: mdl-36904733

ABSTRACT

Optical fiber interferometric magnetic field sensors based on magnetostrictive effects have several advantages, e.g., high sensitivity, strong adaptability to harsh environments, long distance transmission, etc. They also have great application prospects in deep wells, oceans, and other extreme environments. In this paper, two optical fiber magnetic field sensors based on iron-based amorphous nanocrystalline ribbons and a passive 3 × 3 coupler demodulation system were proposed and experimentally tested. The sensor structure and the equal-arm Mach-Zehnder fiber interferometer were designed, and the experimental results showed that the magnetic field resolutions of the optical fiber magnetic field sensors with sensing length of 0.25 m and 1 m were 15.4 nT/√Hz @ 10 Hz and 4.2 nT/√Hz @ 10 Hz, respectively. This confirmed the sensitivity multiplication relationship between the two sensors and the feasibility of improving the magnetic field resolution to the pT level by increasing the sensing length.

SELECTION OF CITATIONS
SEARCH DETAIL