1.
Analyst ; 148(21): 5366-5379, 2023 Oct 23.
Article in English | MEDLINE | ID: mdl-37702052

ABSTRACT

Paracetamol overdose is a leading cause of acute liver failure that can prove fatal. Establishing paracetamol concentration accurately and quickly is critical. Current detection methods are invasive, time-consuming and/or expensive. Non-invasive, rapid and cost-effective techniques are urgently required. To address this challenge, a novel approach, called Paper-Arrow Mass Spectrometry (PA-MS) has been developed. This technique combines sample collection, extraction, enrichment, separation and ionisation onto a single paper strip, and the entire analysis process, from sample to result, can be carried out in less than 10 min requiring only 2 µL of raw human saliva. PA-MS achieved a LOQ of 185 ng mL-1, mean recovery of 107 ± 7%, mean accuracy of 11 ± 8% and precision ≤5% using four concentrations, and had excellent linearity (r2 = 0.9988) in the range of 0.2-200 µg mL-1 covering the treatment concentration range, surpassing the best-in-class methods currently available for paracetamol analysis. Furthermore, from a panel of human saliva samples, inter-individual variability was found to be <10% using this approach. This technique represents a promising tool for rapid and accurate emergency diagnosis.

2.
Analyst ; 148(19): 4677-4687, 2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37697928

ABSTRACT

Surface-enhanced Raman scattering (SERS) is a powerful technique for detecting trace amounts of analytes. However, the performance of SERS substrates depends on many variables including the enhancement factor, morphology, consistency, and interaction with target analytes. In this study, we investigated, for the first time, the use of electrospray deposition (ESD) combined with a novel ambient focusing DC ion funnel to deposit a high density of gold nanoparticles (AuNPs) to generate large-area, uniform substrates for highly sensitive SERS analysis. We found that the combination of ambient ion focusing with ESD facilitated high-density and intact deposition of non-spherical NPs. This also allowed us to take advantage of a polydisperse colloidal solution of AuNPs (consisting of nanospheres and nanorods), as confirmed by finite-difference time domain (FDTD) simulations. Our SERS substrate exhibited excellent capture capacity for model analyte molecules, namely 4-aminothiophenol (4-ATP) and Rhodamine 6G (R6G), with detection limits in the region of 10-11 M and a relative standard deviation of <6% over a large area (∼500 × 500 µm2). Additionally, we assessed the quantitative performance of our SERS substrate using the R6G probe molecule. The results demonstrated excellent linearity (R2 > 0.99) over a wide concentration range (10-4 M to 10-10 M) with a detection limit of 80 pM.

3.
Mikrochim Acta ; 190(6): 215, 2023 05 12.
Article in English | MEDLINE | ID: mdl-37171648

ABSTRACT

The detection of biogenic amines released from degraded meats is an effective method for evaluating meat freshness. However, existing traditional methods like titration are deemed tedious, while the use of sophisticated analytical instruments is not amenable to field testing. Herein, a cyanostilbene-based fluorescent array was rapidly fabricated using macroarray synthesis on a cellulose paper surface to detect amines liberated from spoiled beef, fish, and chicken. The fluorescence changes of immobilized molecules from the interaction with gaseous amines were used to monitor changes in freshness levels. Thanks to the high-throughput nature of macroarray synthesis, a set of highly responsive molecules such as pyridinium and dicyanovinyl moieties were quickly revealed. Importantly, this method offers flexibility in sensing applications including (1) sensing by individual sensor molecules, where the fluorescence response correlated well with established titration methods, and (2) collective sensing whereby chemometric analysis was used to provide a cutoff of freshness with 73-100% accuracy depending on meat types. Overall, this study paves the way for a robust and cost-effective tool for monitoring meat freshness.


Subject(s)
Biogenic Amines , Meat , Animals , Cattle , Meat/analysis , Biogenic Amines/analysis , Coloring Agents , Fishes , Chickens
4.
Sensors (Basel) ; 22(20)2022 Oct 15.
Article in English | MEDLINE | ID: mdl-36298183

ABSTRACT

Azo compounds such as the Sudan dyes I-IV are frequently used illegally as colorants and added to a wide range of foods. These compounds have been linked to a number of food safety hazards. Several methods have been proposed to detect food contamination by azo compounds and most of these are laboratory based; however, the development of reliable and portable methods for the detection and quantification of food contaminated by these chemicals in low concentration is still needed due to their potentially carcinogenic properties. In this study, we investigated the ability of surface enhanced Raman scattering (SERS) combined with chemometrics to quantify Sudan I-IV dyes. SERS spectra were acquired using a portable Raman device and gold nanoparticles were employed as the SERS substrate. As these dyes are hydrophobic, they were first dissolved in water: acetonitrile (1:10, v/v) as single Sudan dyes (I-IV) at varying concentrations. SERS was performed at 785 nm and the spectra were analyzed by using partial least squares regression (PLS-R) with double cross-validations. The coefficient of determination (Q2) were 0.9286, 0.9206, 0.8676 and 0.9705 for Sudan I to IV, respectively; the corresponding limits of detection (LOD) for these dyes were estimated to be 6.27 × 10-6, 5.35 × 10-5, 9.40 × 10-6 and 1.84 × 10-6 M. Next, quadruplex mixtures were made containing all four Sudan dyes. As the number of possible combinations needed to cover the full concentration range at 5% intervals would have meant collecting SERS spectra from 194,481 samples (214 combinations) we used a sustainable solution based on Latin hypercubic sampling and reduced the number of mixtures to be analyzed to just 90. After collecting SERS spectra from these mixture PLS-R models with bootstrapping validations were employed. The results were slightly worse in which the Q2 for Sudan I to IV were 0.8593, 0.7255, 0.5207 and 0.5940 when PLS1 models (i.e., one model for one dye) was employed and they changed to 0.8329, 0.7288, 0.5032 and 0.5459 when PLS2 models were employed (i.e., four dyes were modelled simultaneously). These results showed the potential of SERS to be used as a high-throughput, low-cost, and reliable methods for detecting and quantifying multiple Sudan dyes in low concentration from illegally adulterated samples.


Subject(s)
Metal Nanoparticles , Spectrum Analysis, Raman , Spectrum Analysis, Raman/methods , Coloring Agents/chemistry , Gold/chemistry , Chemometrics , Azo Compounds/chemistry , Acetonitriles , Water
5.
Anal Chem ; 92(13): 9104-9112, 2020 07 07.
Article in English | MEDLINE | ID: mdl-32479060

ABSTRACT

This paper describes, in detail, the development of a novel, low-cost, and flexible drift tube (DT) along with an associated ion mobility spectrometer system. The DT is constructed from a flexible printed circuit board (PCB), with a bespoke "dog-leg" track design, that can be rolled up for ease of assembly. This approach incorporates a shielding layer, as part of the flexible PCB design, and represents the minimum dimensional footprint conceivable for a DT. The low thermal mass of the polyimide substrate and overlapping electrodes, as afforded by the dog-leg design, allow for efficient heat management and high field linearity within the tube-achieved from a single PCB. This is further enhanced by a novel double-glazing configuration which provides a simple and effective means for gas management, minimizing thermal variation within the assembly. Herein, we provide a full experimental characterization of the flexible DT ion mobility spectrometer (Flex-DT-IMS) with corresponding electrodynamic (Simion 8.1) and fluid dynamic (SolidWorks) simulations. The Flex-DT-IMS is shown to have a resolution >80 and a detection limit of low nanograms for the analysis of common explosives (RDX, PETN, HMX, and TNT).

6.
Langmuir ; 35(43): 13853-13859, 2019 Oct 29.
Article in English | MEDLINE | ID: mdl-31585036

ABSTRACT

We have developed a new spray-based method for characterizing surface energies of planar, porous substrates. Distinct spray modes (electrospray versus electrostatic spray), from the porous substrates, occur in the presence of an applied DC potential after wetting with solvents of different surface tension. The ion current resulting from the spray process is maximized when the surface energy of the porous substrate approaches the surface tension of the wetting solvent. By monitoring the selected ion current (e.g., benzoylecgonine, m/z 290 → 168) with a mass spectrometer or the total ion current with an ammeter, we determined the solvent surface tension yielding the maximum ion current to indicate the surface energy of the solid. Detailed evaluations using polymeric substrates of known surface energies enabled effective calibration of the approach that resulted in the correct estimation of the surface energy of hydrophobic paper substrates prepared by gas-phase silanization. A three-parameter empirical model suggests that the experimentally observed ion current profile is governed by differential partitioning of analyte controlled by the interfacial forces between the wetting solvent and the porous substrate.

7.
Anal Chem ; 90(15): 9353-9358, 2018 08 07.
Article in English | MEDLINE | ID: mdl-29975501

ABSTRACT

It is well-known that 2D dried blood spots on paper offer a facile sample collection, storage, and transportation of blood. However, large volume requirements, possible analyte instability, and difficult sample recovery plague this method, lowering confidence in analyte quantification. For the first time, we demonstrate a new approach using 3D dried blood spheroids for stabilization of small volume blood samples, mitigating these effects without cold storage. Blood spheroids form on hydrophobic paper, preventing interaction between the sample and paper substrate, eliminating all chromatographic effects. Stability of the enzyme alanine transaminase and labile organic compounds such as cocaine and diazepam were also shown to increase in the spheroid by providing a critical radius of insulation. On-surface analysis of the dried blood spheroids using paper spray mass spectrometry resulted in sub-ng/mL limits of detection for all illicit drugs tested, representing 1 order of magnitude improvement compared with analysis from 2D dried blood spots.


Subject(s)
Dried Blood Spot Testing/methods , Temperature , Alanine Transaminase/blood , Cocaine/blood , Diazepam/blood , Enzyme Stability , Humans , Hydrophobic and Hydrophilic Interactions , Limit of Detection
8.
Anal Chem ; 88(2): 1391-400, 2016 Jan 19.
Article in English | MEDLINE | ID: mdl-26727190

ABSTRACT

Direct analysis and identification of long chain aliphatic primary diamine Duomeen O (n-oleyl-1,3-diaminopropane), corrosion inhibitor in raw water samples taken from a large medium pressure water tube boiler plant water samples at low LODs (<0.1 pg) has been demonstrated for the first time, without any sample preparation using paper spray mass spectrometry (PS-MS). The presence of Duomeen O in water samples was confirmed via tandem mass spectrometry using collision-induced dissociation and supported by exact mass measurement and reactive paper spray experiments using an LTQ Orbitrap Exactive instrument. Data shown herein indicate that paper spray ambient ionization can be readily used as a rapid and robust method for in situ direct analysis of polymanine corrosion inhibitors in an industrial water boiler plant and other related samples in the water treatment industry. This approach was applied for the analysis of three complex water samples including feedwater, condensate water, and boiler water, all collected from large medium pressure (MP) water tube boiler plants, known to be dosed with varying amounts of polyamine and amine corrosion inhibitor components. Polyamine chemistry is widely used for example in large high pressure (HP) boilers operating in municipal waste and recycling facilities to prevent corrosion of metals. The samples used in this study are from such a facility in Coventry waste treatment facility, U.K., which has 3 × 40 tonne/hour boilers operating at 17.5 bar.

9.
Analyst ; 141(12): 3866-73, 2016 Jun 21.
Article in English | MEDLINE | ID: mdl-27121269

ABSTRACT

Paper-based microfluidic channels were created from solid wax printing, and the resultant 2D wax-printed paper substrates were used for paper spray (PS) mass spectrometry (MS) analysis of small organic compounds. Controlling fluid flow at the tip of the wax-printed paper triangles enabled the use of lower spray voltages (0.5-1 kV) and extended signal lifetime (10 minutes) in PS-MS. High sensitivity (sub ng mL(-1) levels) and quantitation precision (<10% RSD) have been achieved in the analysis of illicit drugs in 4 µL of raw urine (fresh and dry), as well as corrosion inhibitors and pesticides in water samples. The reported study encourages the future development of disposable 3D microfluidic paper-based analytical devices, which function with simple operation but capable of on-chip analyte detection by MS; such a device can replace the traditional complex laboratory procedures for MS analysis to enable on-site in situ sampling with portable mass spectrometers.

10.
Anal Chem ; 87(19): 10047-55, 2015 Oct 06.
Article in English | MEDLINE | ID: mdl-26329926

ABSTRACT

A novel, lightweight (0.6 kg), solvent- and gas-cylinder-free, hand-held ion source based on desorption atmospheric pressure chemical ionization has been developed and deployed for the analysis of nitroaromatic explosives on surfaces in open air, offering portability for in-field analysis. A small, inexpensive, rechargeable lithium polymer battery was used to power the custom-designed circuitry within the device, which generates up to ±5 kV dc voltage to ignite a corona discharge plasma in air for up to 12 h of continuous operation, and allowing positive- and negative-ion mass spectrometry. The generated plasma is pneumatically transported to the surface to be interrogated by ambient air at a rate of 1-3.5 L/min, compressed using a small on-board diaphragm pump. The plasma source allows liquid or solid samples to be examined almost instantaneously without any sample preparation in the open environment. The advantages of low carrier gas and low power consumption (<6 W), as well as zero solvent usage, have aided in developing the field-ready, hand-held device for trigger-based, "near-real-time" sampling/ionization. Individual nitroaromatic explosives (such as 2,4,6-trinitrotoluene) can be easily detected in amounts as low as 5.8 pg with a linear dynamic range of at least 10 (10-100 pg), a relative standard deviation of ca. 7%, and an R(2) value of 0.9986. Direct detection of several nitroaromatic compounds in a complex mixture without prior sample preparation is demonstrated, and their identities are confirmed by tandem mass spectrometry fragmentation patterns.

11.
Anal Chem ; 87(7): 3714-20, 2015 Apr 07.
Article in English | MEDLINE | ID: mdl-25710191

ABSTRACT

A key requirement of electrospray ionization (ESI) and other techniques facilitating ionization at elevated pressures is the efficient transport of free gas-phase ions into the high vacuum region of the mass spectrometer. Radio frequency (RF) multipole ion guides that allow for collisional cooling are one of the most popular means of achieving this. However, their performance is highly dependent on several experimental factors, including pressure and various electrode potentials along the ion path. To experimentally visualize these effects, we have employed a position-sensitive detector at the exit of a quadrupole mass spectrometer (QMS) instrument operated in RF only mode that employs an RF only octopole as a collisional cooling ion guide. This allows the spatial distribution of the ions, and its dependence on experimentally determined conditions, to be directly visualized at the exit of the quadrupole. This investigation provides a detailed insight into the ion dynamics occurring inside multipole ion guides. This knowledge can directly be applied to instrument development and to improve the ion transmission efficiency and, thus, sensitivity. Numerical simulations using custom-developed trajectory simulation software are compared and contrasted with the experimental observations.

12.
Anal Bioanal Chem ; 407(8): 2055-62, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25270865

ABSTRACT

An in-vacuum position-sensitive micropixelated detector (Timepix) is used to investigate the time-dependent spatial distribution of different charge state (and hence different mass-to-charge (m/z)) ions exiting an electrospray ionization (ESI)-based quadrupole mass spectrometer (QMS) instrument. Ion images obtained from the Timepix detector provide a detailed insight into the positions of stable and unstable ions of the mass peak as they exit the QMS. With the help of image processing algorithms and by selecting areas on the ion images where more stable ions impact the detector, an improvement in mass resolution by a factor of 5 was obtained for certain operating conditions. Moreover, our experimental approach of mass resolution enhancement was confirmed by in-house-developed novel QMS instrument simulation software. Utilizing the imaging-based mass resolution enhancement approach, the software predicts instrument mass resolution of ∼1,0000 for a single-filter QMS instrument with a 210-mm long mass filter and a low operating frequency (880 kHz) of the radio frequency (RF) voltage.

13.
Article in English | MEDLINE | ID: mdl-38640067

ABSTRACT

We critically evaluate the current status of portable mass spectrometry (pMS), particularly where this aligns with ambient ionization. Assessing the field of pMS can be quite subjective, especially in relation to the portable aspects of design, deployment, and operation. In this review, we discuss what it means to be portable and introduce a set of criteria by which pMS and ambient ionization sources can be assessed. Moreover, we consider the recent literature in terms of the most popular and significant advances in portable instrumentation for ambient ionization and miniature mass spectrometers. Finally, emerging trends and exciting future prospects are discussed and some recommendations are offered.

14.
Chem Sci ; 15(3): 914-922, 2024 Jan 17.
Article in English | MEDLINE | ID: mdl-38239686

ABSTRACT

Direct infusion ionization methods provide the highest throughput strategy for mass spectrometry (MS) analysis of low-volume samples. But the trade-off includes matrix effects, which can significantly reduce analytical performance. Herein, we present a novel chemical approach to tackle a special type of matrix effect, namely type II isobaric overlap. We focus on detailed investigation of a nanodroplet-based esterification chemistry for differentiating isotopologue [M + 2] signal due to unsaturated fatty acid (FA) from the monoisotopic signal from a saturated FA. The method developed involves the online fusion of nonthermal plasma with charged nanodroplets, enabling selective esterification of saturated FAs. We discovered that unsaturated FAs undergo spontaneous intramolecular reaction via a novel mechanism based on a carbocation intermediate to afford a protonated lactone moiety (resonance stabilized cyclic carbonium ion), whose mass is the same as the original protonated unsaturated FA. Therefore, the monoisotopic signal from any saturated FA can be selectively shifted away from the mass-to-charge position where the isobaric interference occurs to enable effective characterization by MS. The mechanism governing the spontaneous intramolecular reactions for unsaturated FAs was validated with DFT calculations, experimentation with standards, and isotope labeling. This novel insight achieved via the ultrafast plasma-nanodroplet reaction environment provides a potentially useful synthetic pathway to achieve catalyst-free lactone preparation. Analytically, we believe the performance of direct infusion MS can be greatly enhanced by combining our approach with prior sample enrichment steps for applications in biomedicine and food safety. Also, combination with portable mass spectrometers can improve the efficiency of field studies since front-end separation is not possible under such conditions.

15.
Neurosurgery ; 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38578087

ABSTRACT

BACKGROUND AND OBJECTIVES: Rapid detection of cerebrospinal fluid (CSF) leaks is vital for patient recovery after spinal surgery. However, distinguishing CSF-specific transferrin (TF) from serum TF using lateral flow immunoassays (LFI) is challenging due to their structural similarities. This study aims to develop a novel point-of-care diagnostic assay for precise CSF leak detection by quantifying total TF in both CSF and serum. METHODS: Capitalizing on the substantial 100-fold difference in TF concentrations between CSF and serum, we designed a diagnostic platform based on the well-known "hook effect" resulting from excessive analyte presence. Clinical samples from 37 patients were meticulously tested using the novel LFI sensor, alongside immunofixation as a reference standard. RESULTS: The hook effect-based LFI sensor exhibited outstanding performance, successfully discriminating positive clinical CSF samples from negative ones with remarkable statistical significance (positive vs negative t-test; P = 1.36E-05). This novel sensor achieved an impressive 100% sensitivity and 100% specificity in CSF leak detection, demonstrating its robust diagnostic capabilities. CONCLUSION: In conclusion, our study introduces a rapid, highly specific, and sensitive point-of-care test for CSF leak detection, harnessing the distinctive TF concentration profile in CSF compared with serum. This novel hook effect-based LFI sensor holds great promise for improving patient outcomes in the context of spinal surgery and postsurgical recovery. Its ease of use and reliability make it a valuable tool in clinical practice, ensuring timely and accurate CSF leak detection to enhance patient care.

16.
Nat Commun ; 14(1): 5033, 2023 08 18.
Article in English | MEDLINE | ID: mdl-37596260

ABSTRACT

The novel coronavirus pandemic (COVID-19) has necessitated a global increase in the use of face masks to limit the airborne spread of the virus. The global demand for personal protective equipment has at times led to shortages of face masks for the public, therefore makeshift masks have become commonplace. The severe acute respiratory syndrome caused by coronavirus-2 (SARS-CoV-2) has a spherical particle size of ~97 nm. However, the airborne transmission of this virus requires the expulsion of droplets, typically ~0.6-500 µm in diameter (by coughing, sneezing, breathing, and talking). In this paper, we propose a face covering that has been designed to effectively capture SARS-CoV-2 whilst providing uncompromised comfort and breathability for the wearer. Herein, we describe a material approach that uses amorphous silica microspheres attached to cotton fibres to capture bioaerosols, including SARS CoV-2. This has been demonstrated for the capture of aerosolised proteins (cytochrome c, myoglobin, ubiquitin, bovine serum albumin) and aerosolised inactivated SARS CoV-2, showing average filtration efficiencies of ~93% with minimal impact on breathability.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/prevention & control , Gossypium , Cotton Fiber , Ubiquitin
17.
Sci Rep ; 12(1): 16791, 2022 Oct 06.
Article in English | MEDLINE | ID: mdl-36202943

ABSTRACT

A novel experiment has been devised shedding new light on the phenomenon of unipolar induction, also known as "Faraday's Paradox". This is a topic which continues to fascinate scientists and engineers with much debate continuing to this day. In particular, the question of the field co-rotating with the magnet or remaining stationary remains unsettled and supporting evidence exists for both positions. In this study, we present a novel experimental apparatus that includes, for the first time, the relative motion of the measurement circuit including the closing wires, as well as the magnet and disc respectively. The results show that the closing wire needs to be considered as part of the problem, which enables the apparent paradox associated with this phenomenon to be resolved. However, it remains impossible to tell if the field co-rotates with the magnet or if it remains stationary. Instead, direct electron interaction is considered as a viable alternative to resolve remaining paradoxes.

18.
Materials (Basel) ; 15(10)2022 May 10.
Article in English | MEDLINE | ID: mdl-35629460

ABSTRACT

Systematic disinfection of the stethoscope diaphragm is required to ensure that it does not act as a vector for cross-transmission of health-related diseases. Thus, an antimicrobial latex film could be used as a cover to inhibit pathogenic bacteria from growing on its surface. The aim of this work is to determine the antimicrobial activity and mechanical properties of antimicrobial natural rubber (NR) latex films with different types of antimicrobial agents (mangosteen peel powder (MPP), zinc oxide nanoparticles (ZnO NP), and povidone-iodine (PVP-I)). The antimicrobial loading was varied from 0.5, to 1.0, and 2.0 phr to monitor the effective inhibition of Gram-negative bacteria and fungi growth. For MPP and PVP-I antimicrobial agents, a loading of 2.0 phr showed good antimicrobial efficacy with the largest zone of inhibition. Simultaneously, ZnO NP demonstrated excellent antimicrobial activity at low concentrations. The addition of antimicrobial agents shows a comparable effect on the mechanical properties of NR latex films. In comparison to control NR latex film (29.41 MPa, 48.49 N/mm), antimicrobial-filled films have significantly greater tensile and tear strengths (MPP (33.84 MPa, 65.21 N/mm), ZnO NP (31.79 MPa, 52.77 N/mm), and PVP-I (33.25 MPa, 50.75 N/mm). In conclusion, the addition of antimicrobial agents, particularly ZnO NP, can be a better choice for NR latex films because they will serve as both an activator and an antimicrobial. In a clinical context, with regard to frequently used medical equipment such as a stethoscope, such an approach offers significant promise to aid infection control.

19.
Polymers (Basel) ; 14(15)2022 Jul 28.
Article in English | MEDLINE | ID: mdl-35956563

ABSTRACT

Glove tear or perforation is a common occurrence during various activities that require gloves to be worn, posing a significant risk to the wearer and possibly others. This is vitally important in a clinical environment and particularly during surgical procedures. When a glove perforation occurs (and is noticed), the glove must be replaced as soon as possible; however, it is not always noticeable. The present article is focused on the design and development of a novel fluorescence-based sensing mechanism, which is integrated within the glove topology, to help alert the wearer of a perforation in situ. We hypothesized that natural rubber gloves with curcumin infused would yield fluorescence when the glove is damaged, particularly when torn or punctured. The glove design is based on double-dipping between Natural Rubber Latex (NRL) and an inner layer of latex mixed with curcumin, which results in a notable bright yellow-green emission when exposed to UV light. Curcumin (Cur) is a phenolic chemical found primarily in turmeric that fluoresces yellowish-green at 525 nm. The tear region on the glove will glow, indicating the presence of a Cur coating/dipping layer beneath. NRL film is modified by dipping it in a Cur dispersion solution mixed with NRL for the second dipping layer. Using Cur as a filler in NRL also has the distinct advantage of allowing the glove to be made stronger by evenly distributing it throughout the rubber phase. Herein, the optimized design is fully characterized, including physicochemical (fluorescence emission) and mechanical (tensile and tear tests) properties, highlighting the clear potential of this novel and low-cost approach for in situ torn glove detection.

20.
Biosens Bioelectron ; 205: 114094, 2022 Jun 01.
Article in English | MEDLINE | ID: mdl-35202985

ABSTRACT

Lateral flow immunoassays (LFI) have shown great promise for point-of-care (POC) sensing applications, however, its clinical translation is often hindered by insufficient sensitivity for early detection of diseases, including severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). This is mainly due to weak absorption signals of single gold nanoparticles (AuNPs). Here, we developed AuNP clusters that maintain the red color of isolated individual AuNPs, but increase the colorimetric readout to improve the detection sensitivity. The plasmon color-preserved (PLASCOP) AuNP clusters is simply made by mixing streptavidin-coated AuNP core with satellite AuNPs coated with biotinylated antibodies. The biotinylated antibody-streptavidin linker forms a gap size over 15 nm to avoid plasmon coupling between AuNPs, thus maintaining the plasmonic color while increasing the overall light absorption. LFI sensing using PLASCOP AuNP clusters composed of 40 nm AuNPs showed a high detection sensitivity for SARS-CoV-2 nucleocapsid proteins with a limit of detection (LOD) of 0.038 ng mL-1, which was 23.8- and 5.9-times lower value than that of single 15 nm and 40 nm AuNP conjugates, respectively. The PLASCOP AuNP clusters-based LFI sensing also shows good specificity for SARS-CoV-2 nucleocapsid proteins from other influenza and coronaviruses. In a clinical feasibility test, we demonstrated that SARS-CoV-2 particles spiked in human saliva could be detected with an LOD of 54 TCID50 mL-1. The developed PLASCOP AuNP clusters are promising colorimetric sensing reporters that present improved sensitivity in LFI sensing for broad POC sensing applications beyond SARS-CoV-2 detection.


Subject(s)
Biosensing Techniques , COVID-19 , Metal Nanoparticles , COVID-19/diagnosis , Gold , Humans , Immunoassay , SARS-CoV-2