Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 89
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Card Fail ; 28(7): 1222-1226, 2022 07.
Article in English | MEDLINE | ID: mdl-35318127

ABSTRACT

BACKGROUND: There are limited data regarding the management of guideline-directed medical therapy (GDMT) for heart failure with reduced ejection fraction (HFrEF) with virtual visits in comparison with in-office visits. We sought to compare the changes in GDMT (angiotensin-converting enzyme inhibitors, angiotensin II receptor blockers, angiotensin receptor neprilysin inhibitors, mineralocorticoid receptor antagonists, and sodium glucose cotransporter-2 inhibitors) and loop diuretics across visit types. METHODS AND RESULTS: This study included 13,481 outpatient visits performed for 5439 unique patients with HFrEF between March 16, 2020, and March 15, 2021. The rates of initiation and discontinuation of GDMT were documented, and multivariable logistic regression was performed to test associations with outcomes between modes of visit. The rates of medication initiation were higher in office (11.7%) compared with video (9.6%) or telephone (7.2%) visits. In multivariable adjusted analysis, the initiation of at least 1 GDMT class was similar between in-office visits and video visits (adjusted odds ratio [OR] 0.97, 95% confidence interval [CI] 0.82-1.14, P = .703). Telephone visits were associated with less frequent initiation of at least 1 class of GDMT in comparison with in-office visits (adjusted OR 0.64, 95% CI 0.55-0.75; P < .001) and video visits (adjusted OR 0.67, 95% CI 0.55-0.81, P < .001). Despite similar rates of baseline loop diuretic use, patients seen with both video visits (adjusted OR 0.70, 95% CI 0.52-0.94, P = .018) and telephone visits (adjusted OR 0.64, 95% CI 0.49-0.83, P < .001) were less likely to have a loop diuretic initiated when compared with in-office visits. CONCLUSIONS: The initiation of GDMT for HFrEF was similar between in-office and video visits and lower with telephone visits, whereas the initiation of a loop diuretic was less frequent in both types of virtual visits. These data suggest that video streaming capabilities should be encouraged for virtual visits.


Subject(s)
Heart Failure , Telemedicine , Adrenergic beta-Antagonists/therapeutic use , Angiotensin Receptor Antagonists/pharmacology , Angiotensin Receptor Antagonists/therapeutic use , Heart Failure/drug therapy , Heart Failure/epidemiology , Humans , Outpatients , Sodium Potassium Chloride Symporter Inhibitors/therapeutic use , Stroke Volume , Telephone
2.
Echocardiography ; 38(7): 1179-1185, 2021 07.
Article in English | MEDLINE | ID: mdl-34047394

ABSTRACT

INTRODUCTION: Anomalous aortic origin of a coronary artery (AAOCA) is a potential etiology of sudden cardiac death (SCD) in physically active individuals. Identification of coronary artery origins is an essential part of comprehensive pre-participation athletic screening. Although echocardiography is an established method for identifying AAOCA, current imaging protocols are time intensive and readers frequently have low confidence in coronary artery identification. METHODS: Echocardiographic images from a sample of 110 patients from a database of competitive athletes ages 13-22 years from the Kansas City metropolitan area were reviewed by six echocardiographers of varying experience. Coronary artery images were provided to the readers in the conventional single plane for all the patients; then biplane images of the same patients were presented to the readers. While reviewing the images, readers recorded perceived confidence level of identifying the coronary artery from 1 (least confident) to 5 (most confident). Ratings and differences between ratings were summarized descriptively by means and standard deviations across all readings as well as by individual reader. RESULTS: The mean confidence level of echocardiogram readers in identifying coronary artery origins increased by 0.4 points (P = .05) on a five-point confidence scale when using biplane imaging rather than single plane imaging. When assessing the variability of confidence of readers on the same patient, the between-reader variability improved from 25.9% to 10.3%. CONCLUSIONS: Biplane echocardiographic imaging increases the confidence of readers in identifying coronary artery origins.


Subject(s)
Coronary Vessel Anomalies , Coronary Vessels , Adolescent , Adult , Aorta , Coronary Vessel Anomalies/diagnostic imaging , Coronary Vessels/diagnostic imaging , Death, Sudden, Cardiac , Echocardiography , Humans , Young Adult
3.
Catheter Cardiovasc Interv ; 95(5): 920-923, 2020 04 01.
Article in English | MEDLINE | ID: mdl-31250510

ABSTRACT

A 34-year-old woman with history of surgical correction (Takeuchi procedure) of anomalous left coronary artery from the pulmonary artery (ALCAPA) presented with reduced left ventricular ejection fraction of 48% and severe ischemia quantified as 21% by stress Positron Emission Tomography (PET) scan. A coronary angiogram revealed ostial 90% stenosis of the left main coronary artery (LMCA). A guidewire (Sion Blue, Asahi Intecc USA, Inc., Santa Ana, CA) was navigated robotically and after pre-dilation with 3.5 × 15 mm cutting balloon, the lesion length was measured by marking the distal end of the lesion with the balloon marker and withdrawing back robotically to the ostium of the LMCA. A 3.5 × 16 mm drug-eluting stent was deployed robotically after intravascular ultrasound (IVUS) with good results. The main advantage of robotic percutaneous coronary intervention includes the precise measurement and positioning of the stent. Since the guide catheter and balloon can be adjusted without guide catheter and device interaction, precise placement of stent is possible by advancing the device distal to the lesion, positioning the guide catheter just proximal to the proximal edge of the stent and pulling the guidecatheter and device back as a unit. Final IVUS after post-dilation with 4.0 noncompliant and 5.0 compliant balloon revealed precise placement at the ostium and full stent expansion.


Subject(s)
Angioplasty, Balloon, Coronary , Bland White Garland Syndrome/surgery , Cardiac Surgical Procedures/adverse effects , Coronary Stenosis/therapy , Coronary Vessels/surgery , Pulmonary Artery/surgery , Robotics , Therapy, Computer-Assisted , Adult , Angioplasty, Balloon, Coronary/instrumentation , Bland White Garland Syndrome/diagnostic imaging , Bland White Garland Syndrome/physiopathology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/etiology , Coronary Stenosis/physiopathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Drug-Eluting Stents , Female , Humans , Pulmonary Artery/abnormalities , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/physiopathology , Therapy, Computer-Assisted/instrumentation , Treatment Outcome
4.
Circ J ; 84(8): 1237-1243, 2020 07 22.
Article in English | MEDLINE | ID: mdl-32595176

ABSTRACT

BACKGROUND: The SALUTE trial was a prospective, multicenter, single-arm trial to confirm the safety and efficacy of the WATCHMAN left atrial appendage closure (LAAC) device for stroke prevention in patients with nonvalvular atrial fibrillation (NVAF) in Japan.Methods and Results:A total of 54 subjects (including 12 roll-in subjects) with a WATCHMAN implant procedure were followed in 10 investigational centers. Follow-up visits were performed up to 2 years post-implant. The baseline CHA2DS2-VASc score was 3.6±1.6 and the baseline HAS-BLED score was 3.0±1.1. All 42 subjects in the intention to treat (ITT) cohort underwent successful implantation of the LAAC device without any serious complications, achieving the prespecified performance goal. The effective LAAC rate was maintained at 100% from 45 days to 12 months post-implant, achieving the prespecified performance goal. During follow-up, 1 subject died of heart failure, and 3 had ischemic strokes, but there were no cases of hemorrhagic stroke or systemic embolism. All events were adjudicated as unrelated to the WATCHMAN device/procedure by the independent Clinical Events Committee. All 3 ischemic strokes were classified as nondisabling based on no change in the modified Rankin scale score. CONCLUSIONS: Final results of the SALUTE trial demonstrated that the WATCHMAN LAAC device is an effective and safe alternative nonpharmacological therapy for stroke risk reduction in Japanese NVAF patients who are not optimal candidates for lifelong anticoagulation. (Trial Registration: clinicaltrials.gov Identifier NCT03033134).


Subject(s)
Atrial Appendage , Atrial Fibrillation/therapy , Cardiac Catheterization/instrumentation , Stroke/prevention & control , Aged , Aged, 80 and over , Atrial Appendage/physiopathology , Atrial Fibrillation/complications , Atrial Fibrillation/mortality , Atrial Fibrillation/physiopathology , Atrial Function, Left , Cardiac Catheterization/adverse effects , Cardiac Catheterization/mortality , Female , Heart Disease Risk Factors , Heart Rate , Humans , Japan , Male , Middle Aged , Prospective Studies , Stroke/etiology , Stroke/mortality , Time Factors , Treatment Outcome
5.
Circulation ; 138(9): 874-885, 2018 08 28.
Article in English | MEDLINE | ID: mdl-29752398

ABSTRACT

BACKGROUND: In patients with atrial fibrillation, left atrial appendage closure with the Watchman device prevents thromboembolism from the left atrial appendage; however, thrombus may form on the left atrial face of the device, and then potentially embolize. Herein, we studied the incidence, predictors, and clinical outcome of device-related thrombus (DRT) using a large series of clinical trial cohorts of patients undergoing Watchman implantation. METHODS: We studied the device arms of 4 prospective Food and Drug Administration trials: PROTECT-AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) (n=463); PREVAIL (Evaluation of the Watchman LAA Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy) (n=269); CAP (Continued Access to PROTECT AF registry) (n=566); and CAP2 (Continued Access to PREVAIL registry) (n=578). Surveillance transesophageal echocardiographs were performed at 45 days and 12 months in all patients, and also at 6 months in the randomized control trials. We assessed both the incidence of DRT during these transesophageal echocardiographs (and other unscheduled transesophageal echocardiographs), and clinical outcomes of postprocedure stroke or systemic embolism (SSE) and adjusted for CHA2DS2-VASC and HAS-BLED scores. RESULTS: Of 1739 patients who received an implant (7159 patient-years follow-up; CHA2DS2-VASc=4.0), DRT was seen in 65 patients (3.74%). The rates of SSE with and without DRT were 7.46 and 1.78 per 100 patient-years (adjusted rate ratio, 3.55; 95% confidence interval [CI], 2.18-5.79; P<0.001), and ischemic SSE rates were 6.28 and 1.65 per 100 patient-years (adjusted rate ratio, 3.22; 95% CI, 1.90-5.45, P<0.001). On multivariable modeling analysis, the predictors of DRT were as follows: history of transient ischemic attack or stroke (odds ratio [OR], 2.31; 95% CI, 1.26-4.25; P=0.007), permanent atrial fibrillation (OR, 2.24; 95% CI, 1.19-4.20; P=0.012); vascular disease (OR, 2.06; 95% CI, 1.08-3.91; P=0.028); left atrial appendage diameter (OR, 1.06 per mm increase; 95% CI, 1.01-1.12; P=0.019); left ventricular ejection fraction (OR, 0.96 per 1% increase; 95% CI, 0.94-0.99; P=0.009). DRT and SSE both occurred in 17 of 65 patients (26.2%). Of the 19 SSE events in these patients with DRT, 9 of 19 (47.4%) and 12 of 19 (63.2%) occurred within 1 and 6 months of DRT detection. Conversely, after left atrial appendage closure, most SSEs (123/142, 86.62%) occurred in patients without DRT. CONCLUSIONS: After left atrial appendage closure with Watchman, DRT (≈3.7%) is not frequent but, when present, is associated with a higher rate of stroke and systemic embolism.


Subject(s)
Atrial Appendage/physiopathology , Atrial Fibrillation/therapy , Atrial Function, Left , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Intracranial Embolism/epidemiology , Stroke/epidemiology , Thrombosis/epidemiology , Aged , Aged, 80 and over , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/physiopathology , Echocardiography, Transesophageal , Female , Humans , Incidence , Intracranial Embolism/diagnostic imaging , Male , Prosthesis Design , Randomized Controlled Trials as Topic , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Stroke/diagnostic imaging , Thrombosis/diagnostic imaging , Time Factors , Treatment Outcome
6.
Circ J ; 82(12): 2946-2953, 2018 11 24.
Article in English | MEDLINE | ID: mdl-30305484

ABSTRACT

BACKGROUND: The PROTECT AF and PREVAIL trials demonstrated that the WATCHMAN left atrial appendage (LAA) closure device is a reasonable alternative to warfarin therapy for stroke prevention in patients with nonvalvular atrial fibrillation (NVAF) in the USA and Europe. We conducted the SALUTE trial to confirm the safety and efficacy of the LAA closure therapy for patients with NVAF in Japan. Methods and Results: A total of 54 subjects (including 12 Roll-in) with NVAF who had a CHA2DS2-VASc score ≥2 were enrolled. All subjects were successfully implanted with the LAA closure device. No serious adverse events related to the primary procedure-safety endpoint occurred. The 2nd co-primary endpoint was a composite of all stroke, systemic embolism and cardiovascular/unexplained death. One ischemic stroke (1/42) occurred during the 6-month follow-up. The effective LAA closure rate defined as the 3rd co-primary endpoint was 100% (42/42) at both 45-day and 6-month follow-up. CONCLUSIONS: The procedural safety and 6-month results from the SALUTE trial demonstrated that the LAA closure device was safe and effective, similar to the results of large-scale randomized clinical trials, and provides a novel perspective of LAA closure for Japanese patients with NVAF in need of an alternative to long-term oral-anticoagulation. (Trial Registration: clinicaltrials.gov Identifier NCT 03033134).


Subject(s)
Anticoagulants/administration & dosage , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Surgical Procedures , Thromboembolism/prevention & control , Administration, Oral , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Atrial Fibrillation/mortality , Female , Humans , Japan/epidemiology , Male , Middle Aged , Prospective Studies , Risk Factors , Thromboembolism/complications
7.
Echocardiography ; 34(1): 128-130, 2017 Jan.
Article in English | MEDLINE | ID: mdl-27862233

ABSTRACT

Left atrial appendage closure with the WATCHMAN device is an alternative to chronic oral anticoagulation for thromboembolic prophylaxis in atrial fibrillation patients. Left atrial device-related thrombus (DRT) has been described in the first year after implant with an incidence of ~6%. A 79-year-old man underwent WATCHMAN device placement in 2006. Routine protocol specified follow-up transesophageal echocardiograms (TEE) at 6 weeks, 6 months, and 1 year following implant showed no evidence for DRT or peri-device flow. A decade after device implant, the patient presented with severe symptomatic aortic stenosis and underwent repeat TEE, which revealed a 21 mm × 18 mm DRT on the LA aspect of the WATCHMAN device. He was prescribed apixaban 5 mg po BID. A TEE performed 111 days later demonstrated marked diminution in the DRT (9 mm in diameter). This case demonstrates that WATCHMAN DRT may occur late following implantation.


Subject(s)
Atrial Appendage/surgery , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Embolic Protection Devices/adverse effects , Forecasting , Heart Diseases/diagnosis , Thrombosis/diagnosis , Aged , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/surgery , Follow-Up Studies , Heart Diseases/etiology , Humans , Male , Prosthesis Failure , Thrombosis/etiology
8.
Echocardiography ; 33(7): 1092-1094, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27009637

ABSTRACT

A 61-year-old man presented with unstable angina 16 years after undergoing coronary artery bypass grafting with a left internal mammary artery graft to the left anterior descending coronary artery and a sequential saphenous vein graft (SVG) to the right coronary artery and an obtuse marginal branch. Transthoracic echocardiography (TTE) with a Philips iE33 machine and an S5 transducer revealed a 5.3 cm × 4.6 cm mass with a central echolucent area, surrounded by a peripheral zone of increased echodensity adjacent to, and partially compressing, the right atrium. Contrast echocardiography following an intravenous bolus injection of Definity revealed late appearance of contrast within the mass consistent with a giant SVG aneurysm. Coronary artery bypass graft angiography revealed a giant aneurysm in the SVG proximal to the RCA anastomosis; the distal limb of the graft to the obtuse marginal branch was occluded. Under intravascular ultrasound guidance, a 7-mm spider filter was placed in the distal graft; then, a 6 mm × 10 cm Viabahn self-expanding nitinol polyethylene terephthalate-covered stent was deployed in the SVG with good seal zones proximally and distally. A follow-up contrast-enhanced transthoracic echocardiogram 1 day postprocedure revealed partial thrombosis of the aneurysm cavity. Ultrasound contrast did not appear in the aneurysm following intravenous injection, consistent with complete exclusion from the systemic circulation. This is the first report demonstrating feasibility of contrast-enhanced transthoracic echocardiography for the diagnosis of SVG aneurysm and confirming procedural success by documenting exclusion from the systemic circulation following intervention.

9.
Echocardiography ; 33(5): 792-795, 2016 May.
Article in English | MEDLINE | ID: mdl-26775639

ABSTRACT

The WATCHMAN left atrial (LA) appendage closure system is an alternative therapy for stroke prevention in patients with atrial fibrillation who are intolerant to chronic oral anticoagulation with warfarin. Infrequently, LA device-related thrombus (DRT) has been suspected. Optimal treatment of DRT is not known, and the efficacy of novel oral anticoagulants (NOAC) in this setting has not been previously described. A 69-year-old woman with permanent atrial fibrillation underwent WATCHMAN device placement. A transesophageal echocardiogram (TEE) performed 45 days following implant revealed a well-seated device. A 1-year follow-up TEE revealed a 1.2 × 0.8 cm sized DRT on the LA aspect of the WATCHMAN device. She was prescribed dabigatran 150 mg po BID for 3 months and she remained on aspirin 325 mg per day. She returned approximately 4 months later (and several weeks after completing her 3-month course of dabigatran) for a repeat TEE, which revealed complete resolution of the DRT. A TEE was performed approximately 8 months later and revealed a new DRT measuring 1 cm in diameter on the LA aspect of the device. This is the first report of successful WATCHMAN DRT treatment with a NOAC, and the first report of late DRT recurrence following treatment to resolution with an anticoagulant. This case report demonstrates that (1) WATCHMAN DRT may form late following implantation, (2) DRT resolution is possible with NOACs, specifically dabigatran, and (3) late recurrence of DRT is possible, even after treatment to initial resolution with systemic anticoagulation.

10.
J Electrocardiol ; 48(3): 407-14, 2015.
Article in English | MEDLINE | ID: mdl-25795567

ABSTRACT

BACKGROUND: We evaluated the prevalence of isolated T-wave inversions (TWI) in American athletes using contemporary ECG criteria. Ethnic and gender disparities including the association of isolated TWI with underlying abnormal cardiac structure are evaluated. METHODS: From 2004 to 2014, 1755 collegiate athletes at a single American university underwent prospective collection of medical history, physical examination, 12-lead ECG, and 2-dimensional echocardiography. ECG analysis was performed to evaluate for isolated TWI as per contemporary ECG criteria. RESULTS: The overall prevalence of isolated TWI is 1.3%. Ethnic and gender disparities are not observed in American athletes (black vs. white: 1.7% vs. 1.1%; p=0.41) (women vs. men: 1.5% vs. 1.1; p=0.52). No association was found with underlying cardiomyopathy. CONCLUSION: A lower prevalence of isolated TWI in American athletes than previously reported. Isolated TWI was not associated with an abnormal echocardiogram. No ethnic or gender disparity is seen in American college athletes.


Subject(s)
Athletes/statistics & numerical data , Cardiomyopathy, Hypertrophic/diagnosis , Cardiomyopathy, Hypertrophic/epidemiology , Electrocardiography/statistics & numerical data , Students/statistics & numerical data , Adolescent , Black or African American/statistics & numerical data , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/prevention & control , Diagnostic Tests, Routine/statistics & numerical data , Early Diagnosis , Electrocardiography/methods , Female , Humans , Incidence , Kansas/ethnology , Male , Mandatory Testing/statistics & numerical data , Mass Screening/statistics & numerical data , Prevalence , Prognosis , Reproducibility of Results , Risk Assessment/methods , Risk Factors , Sensitivity and Specificity , Survival Rate , Universities , White People/statistics & numerical data
11.
Mo Med ; 109(5): 397-401, 2012.
Article in English | MEDLINE | ID: mdl-23097947

ABSTRACT

BACKGROUND: The prevalence of obesity has increased markedly over the past four decades; however, some reports suggest a recent plateau. There is little information available regarding recent changes in obesity prevalence among patients hospitalized with cardiovascular disease. OBJECTIVE: To define obesity trends among patients hospitalized with cardiovascular disease between 2002 and 2009 at an academic medical center. METHODS: This is a retrospective database analysis of patients admitted with cardiovascular diagnoses in 2002 versus 2009. Using ICD-9 codes, the study population was generated. Body mass index (BMI) was calculated by dividing weight in kilograms by height in meters squared (Quetelet index). Patients were assigned to 1 of 5 BMI categories: normal weight (BMI < 19-24.99), overweight (BMI 25-29.99), Grades I obesity (BMI 30-34.99), Grade II obesity (BMI 35-39.99), and Grade III obesity (BMI > 40). Patient demographics are compared with Student's T-tests for continuous data and chi2 tests for categorical data. Logistic regression models were developed in the overall cohort to ascertain differences in obesity grades I, II & III between the two time points with age, gender, race and primary ICD-9 code included as covariates. The logistic regression models were then repeated for each primary ICD-9 code. RESULTS: Patients admitted with cardiovascular diagnoses in 2002 (n = 1271) and 2009 (n = 1576) were stratified by BMI categories. Over this period of nine years, obesity prevalence increased significantly from 28.5% to 38.4% of patients. In particular, Grades II and III obesity increased markedly from 2002 to 2009 (7.6% versus 9.9%, and 2.7% versus 7.5%; unadjusted p = 0.04, p < 0.001 and adjusted p = 0.09 and p < 0.0001 respectively). Individuals with Grade III obesity had a higher incidence of arrhythmias, coronary heart disease, and valvular heart disease. CONCLUSIONS: Grade II and III obesity has markedly increased among patients admitted to our hospital with major cardiovascular diagnoses in the period 2002 to 2009. With respect to hospitalized patients, the obesity epidemic is still on a steeply rising trajectory, especially for the extremely obese categories.


Subject(s)
Cardiovascular Diseases/epidemiology , Obesity/epidemiology , Aged , Aged, 80 and over , Arrhythmias, Cardiac/epidemiology , Female , Heart Valve Diseases/epidemiology , Hospitalization , Humans , International Classification of Diseases , Male , Obesity/classification , Peripheral Arterial Disease/epidemiology , Prevalence
12.
Mo Med ; 109(6): 489-92, 2012.
Article in English | MEDLINE | ID: mdl-23362654

ABSTRACT

Drug and device therapy for heart failure is increasingly determined based on left ventricular ejection fraction. Significant disparity frequently exists between echocardiographic and nuclear scintigraphic techniques, even when testing is performed nearly simultaneously in clinically stable patients. In 119 patients with left ventricular dysfunction who underwent both echocardiography and stress testing with nuclear imaging within seven days (but with significant disparity in reported left ventricular ejection fraction), we identified four clinical variables which were associated with left ventricular ejection fraction difference. These clinical variables included atrial fibrillation, left ventricular hypertrophy, severe mitral regurgitation and paced rhythm.


Subject(s)
Echocardiography , Stroke Volume , Tomography, Emission-Computed, Single-Photon , Ventricular Dysfunction, Left/diagnostic imaging , Aged , Exercise Test , Female , Humans , Logistic Models , Male , Missouri , Retrospective Studies , Risk Assessment , Risk Factors , Ventricular Dysfunction, Left/physiopathology
13.
Echo Res Pract ; 9(1): 7, 2022 Aug 23.
Article in English | MEDLINE | ID: mdl-35996167

ABSTRACT

The present CEUS Cardiac Exam Protocols represent the first effort to promulgate a standard set of protocols for optimal administration of ultrasound enhancing agents (UEAs) in echocardiography, based on more than two decades of experience in the use of UEAs for cardiac imaging. The protocols reflect current clinical CEUS practice in many modern echocardiography laboratories throughout the world. Specific attention is given to preparation and dosing of three UEAs that have been approved by the United States Food and Drug Administration (FDA) and additional regulatory bodies in Europe, the Americas and Asia-Pacific. Consistent with professional society guidelines (J Am Soc Echocardiogr 31:241-274, 2018; J Am Soc Echocardiogr 27:797-810, 2014; Eur Heart J Cardiovasc Imaging 18:1205, 2017), these protocols cover unapproved "off-label" uses of UEAs-including stress echocardiography and myocardial perfusion imaging-in addition to approved uses. Accordingly, these protocols may differ from information provided in product labels, which are generally based on studies performed prior to product approval and may not always reflect state of the art clinical practice or guidelines.

15.
Echocardiography ; 28(5): 502-7, 2011 May.
Article in English | MEDLINE | ID: mdl-21535117

ABSTRACT

BACKGROUND: In investigational medicinal products testing centers (IMP), reliable methods for monitoring early signs of cardiotoxicity of a potential new drug in healthy volunteers are essential. This study examines what levels of left ventricular ejection fraction (LVEF) variance can be achieved with two-dimensional echocardiography (2DE) in a core laboratory versus a site laboratory. Diurnal variability of LVEF and diastolic parameters were also reviewed. METHODS AND RESULTS: 64 healthy males, (age range 18-40 years), with optimal echo windows were recruited. Two-dimensional and tissue Doppler (TDI) echocardiography was performed by one dedicated sonographer using an Acuson Sequoia C256 machine. Heart rate and blood pressure were recorded simultaneously. Echocardiograms were performed at set time points (0, 1, 4, and 20 hours) on all subjects. The images were analyzed independently by one on-site, unblinded, sonographer reader (site lab) and one experienced off-site blinded physician over reader (core lab). The core lab showed significantly less variance in LVEF measurements than the site lab (5.5% vs. 19.9%). There was no significant diurnal variation in mean blood pressure, LVEF or E:A ratio measurements over 20 hours. CONCLUSIONS: The core lab had better reproducibility and significantly less variance in LVEF measurements by 2DE than the site lab. There was no diurnal variation in LV function measurement.


Subject(s)
Circadian Rhythm/drug effects , Drug-Related Side Effects and Adverse Reactions , Heart Ventricles/diagnostic imaging , Heart Ventricles/physiopathology , Toxicity Tests/methods , Ventricular Dysfunction, Left/chemically induced , Ventricular Dysfunction, Left/diagnostic imaging , Adolescent , Circadian Rhythm/physiology , Echocardiography/methods , Female , Heart Ventricles/drug effects , Humans , Reference Values , Reproducibility of Results , Sensitivity and Specificity , Ventricular Dysfunction, Left/physiopathology , Young Adult
16.
Am J Cardiol ; 150: 117-122, 2021 07 01.
Article in English | MEDLINE | ID: mdl-34001340

ABSTRACT

Limited data suggests ultrasound enhancing agent (UEA) use is associated with changes in clinical management and lower mortality in intensive care unit (ICU) patients. We conducted a retrospective observational study to determine if contrast echocardiography (vs non-contrast echocardiography) is associated with differences in length of stay (LOS) and subsequent resource utilization in the ICU setting. The Premier Healthcare Database (Charlotte, NC) was analyzed to identify patients receiving Definity vs. no use of contrast during the initial rest transthoracic echocardiogram (TTE) in an ICU setting. The primary outcomes of interest were subsequent TTE and transesophageal echocardiography (TEE) during the index hospitalization, and ICU LOS. Propensity scoring was used to statistically model treatment selection to minimize selection bias. A total of 1,538,864 patients from 773 hospitals were identified as undergoing resting TTE in the ICU with use of DEFINITY in 51,141 (3.3%) patients and no contrast agent use in 1,487,723 (96.7%) patients. After adjusting for patient, clinical, and hospital characteristics, patients in the Definity cohort were less likely to undergo a subsequent TTE or TEE as compared to those in the no contrast cohort (odds ratio = 0.704 for TTE, odds ratio = 0.841 for TEE; p < 0.0001 for both). Adjusted mean ICU LOS for the Definity cohort was shorter than that of the no contrast cohort (4.59 vs 4.15 days, p < 0.0001). In conclusion, Definity-enhanced echocardiography in the ICU setting (in comparison with non-contrast TTE) is associated with lower rates of subsequent TTE and TEE during the index hospitalization, and shorter ICU LOS.


Subject(s)
Critical Illness , Echocardiography , Fluorocarbons/administration & dosage , Adult , Aged , Cost Savings , Female , Humans , Intensive Care Units , Length of Stay/statistics & numerical data , Male , Middle Aged , Propensity Score , Retrospective Studies , United States
17.
JACC Heart Fail ; 9(12): 916-924, 2021 12.
Article in English | MEDLINE | ID: mdl-34857175

ABSTRACT

OBJECTIVES: This study sought to determine whether the increased use of telehealth was associated with a difference in outcomes for outpatients with heart failure. BACKGROUND: The COVID-19 pandemic led to dramatic changes in the delivery of outpatient care. It is unclear whether increased use of telehealth affected outcomes for outpatients with heart failure. METHODS: In March 2020, a large Midwestern health care system, encompassing 16 cardiology clinics, 16 emergency departments, and 12 hospitals, initiated a telehealth-based model for outpatient care in the setting of the COVID-19 pandemic. A propensity-matched analysis was performed to compare outcomes between outpatients seen in-person in 2018 and 2019 and via telemedicine in 2020. RESULTS: Among 8,263 unique patients with heart failure with 15,421 clinic visits seen from March 15 to June 15, telehealth was employed in 88.5% of 2020 visits but in none in 2018 or 2019. Despite the pandemic, more outpatients were seen in 2020 (n = 5,224) versus 2018 and 2019 (n = 5,099 per year). Using propensity matching, 4,541 telehealth visits in 2020 were compared with 4,541 in-person visits in 2018 and 2019, and groups were well matched. Mortality was similar for telehealth and in-person visits at both 30 days (0.8% vs 0.7%) and 90 days (2.9% vs 2.4%). Likewise, there was no excess in hospital encounters or need for intensive care with telehealth visits. CONCLUSIONS: A telehealth model for outpatients with heart failure allowed for distanced encounters without increases in subsequent acute care or mortality. As the pressures of the COVID-19 pandemic abate, these data suggest that telehealth outpatient visits in patients with heart failure can be safely incorporated into clinical practice.


Subject(s)
COVID-19 , Heart Failure , Telemedicine , Heart Failure/epidemiology , Heart Failure/therapy , Humans , Outpatients , Pandemics , SARS-CoV-2
18.
Am J Cardiol ; 137: 127-129, 2020 12 15.
Article in English | MEDLINE | ID: mdl-32991857

ABSTRACT

Described herein is a 49-year-old black man with advanced polycystic renal disease, on hemodialysis for 6 years, who during his last 12 days of life had his vegetations on the aortic valve extend to the mitral and tricuspid valves, through the aortic wall to produce diffuse pericarditis, to the atrioventricular node to produce complete heart block, and embolize to cerebral arteries producing multiple brain infarcts, to a branch on the left circumflex coronary artery producing acute myocardial infarction, and to mesenteric arteries producing bowel infarction.


Subject(s)
Cerebral Infarction/etiology , Endocarditis/complications , Heart Block/etiology , Heart Valve Diseases/etiology , Myocardial Infarction/etiology , Aortic Valve , Cerebral Infarction/diagnosis , Echocardiography , Electrocardiography , Endocarditis/diagnosis , Fatal Outcome , Heart Valve Diseases/diagnosis , Humans , Male , Middle Aged , Mitral Valve , Myocardial Infarction/diagnosis , Tricuspid Valve
19.
J Am Soc Echocardiogr ; 33(12): 1500-1508, 2020 12.
Article in English | MEDLINE | ID: mdl-32919859

ABSTRACT

BACKGROUND: Ultrasound enhancing agents (UEAs) are routinely used to improve transthoracic echocardiographic (TTE) image quality, yet anticipation of UEA need is a barrier to their use. METHODS: Structured report data from 171,509 consecutive TTE studies in 97,515 patients who underwent TTE imaging from January 26, 2000, to September 20, 2018, were analyzed. Trends in UEA use and suboptimal image quality were examined. Among outpatients (92,291 TTE examinations, n = 56,479), the data set was randomly split into a 75% derivation sample and a 25% validation sample. Logistic regression was used to model the composite of either UEA receipt or suboptimal image quality (two or more nonvisualized segments) using only variables available at the start of the TTE examination. Model performance was tested in the validation sample. RESULTS: A total of 4,444 TTE examinations (2.6%) in 3,827 patients (3.9%) involved UEAs, and 28,468 TTE examinations (16.6%) in 21,994 patients (22.5%) were suboptimal. UEA use increased over the observation period. Among TTE studies with suboptimal image quality, UEA use was lower in women (P < .0001). Among outpatients referred for TTE imaging, older age, greater weight, and higher heart rate best predicted UEA use or suboptimal image quality. Model performance in the validation sample was excellent (C statistic = 0.74 [95% CI, 0.73-0.75]; calibration slope = 1.11 [95% CI, 1.06-1.15]). CONCLUSIONS: In this large, single-center, retrospective study, UEA use remained substantially below rates of suboptimal image quality, despite increases over time. Among outpatients, a simple prediction rule using three routinely collected variables available before TTE image acquisition predicted potential benefit from UEAs with high accuracy. If confirmed in other cohorts, this rule may be used to identify patients who may benefit from intravenous placement for UEA administration before TTE image acquisition, thus potentially improving work-flow efficiency.


Subject(s)
Echocardiography , Aged , Female , Humans , Retrospective Studies
20.
Eur J Echocardiogr ; 10(2): 347-9, 2009 Mar.
Article in English | MEDLINE | ID: mdl-18723848

ABSTRACT

We report a case of an ischaemic stroke secondary to an isolated pulmonary arteriovenous malformation. In this case, transoesophageal echocardiogram played a pivotal role in shunt identification, exclusion of atrial septal defect, and definitive diagnosis and localization of the pulmonary arteriovenous malformations. Pulmonary arteriovenous malformations should be excluded in all patients with cryptogenic stroke.


Subject(s)
Arteriovenous Malformations/diagnostic imaging , Brain Ischemia/diagnostic imaging , Intracranial Embolism/diagnostic imaging , Stroke/diagnostic imaging , Arteriovenous Malformations/pathology , Arteriovenous Malformations/therapy , Brain Ischemia/pathology , Brain Ischemia/therapy , Echocardiography , Echocardiography, Transesophageal , Female , Humans , Intracranial Embolism/pathology , Intracranial Embolism/therapy , Middle Aged , Stroke/pathology , Stroke/therapy
SELECTION OF CITATIONS
SEARCH DETAIL