Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Country/Region as subject
Language
Publication year range
1.
Cardiovasc Revasc Med ; 18(3): 160-164, 2017.
Article in English | MEDLINE | ID: mdl-28017259

ABSTRACT

BACKGROUND: Procedural and clinical outcomes in patients with very long (>30mm) coronary lesions who underwent stent-based percutaneous coronary interventions are still unfavorable. Therefore, we compared the relative efficacy and safety of resolute zotarolimus-eluting stents (R-ZES) and Xpedition everolimus-eluting stents (X-EES) for patients with de novo very long coronary lesions. METHODS: This comparative single-centre, retrospective study compared long R-ZES and X-EES in consecutive patients admitted with very long (≥30mm) native ACC/AHA type C coronary lesions in 2014. All patients were followed up clinically at 1, 3, 6 and 12months. In this study, only symptom-driven angiogram was advised. The study end point was to evaluate immediate procedural success and one-year rate of target lesion failure (TLF), which is a composite of cardiac death, target lesion myocardial infarction, or target lesion revascularization (TLR). RESULTS: Total number of patients enrolled in this study was 185 (R-ZES=107; X-EES=78). The baseline characteristics and post procedural success rate were similar between R-ZES and X-EES groups, including the post stenting lesion lengths (36.6±1.92mm vs 40.71±6.175mm, P=0.09). At 12-month follow-up, there were no significant between-group differences in the rate of adverse clinical events (death, myocardial infarction, stent thrombosis, target lesion revascularization, and composite outcomes). Procedural success was achieved in 94% in R-ZES group and 93% in X-EES group (P=0.24). The incidence of TLF was 5% in R-ZES and 4% in X-EES groups (HR-1.25; 95% CI-0.86-5.6; P=0.19). CONCLUSION: Patients with de novo long coronary artery disease, R-ZES implantation showed similar clinical outcome as compared with X-EES implantation.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Stenosis/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Sirolimus/analogs & derivatives , Aged , Cardiovascular Agents/adverse effects , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Everolimus/adverse effects , Female , Humans , India , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Risk Factors , Sirolimus/administration & dosage , Sirolimus/adverse effects , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL