Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 56
Filter
1.
Audiol Neurootol ; 29(5): 341-350, 2024.
Article in English | MEDLINE | ID: mdl-38377970

ABSTRACT

INTRODUCTION: Bone conduction implants have been indicated for patients with conductive hearing loss, mixed hearing loss, and even profound unilateral sensorineural hearing loss. With the introduction of Bonebridge®, new transcutaneous implant options emerged. The latest is Osia®, a direct-drive variant or active systems, where the implant directly generates and applies vibration to the bone. MATERIALS AND METHODS: Retrospective study of two cohorts of patients treated with active bone conduction implants at a single center, one with the Bonebridge® device and the other with Osia®. OUTCOMES: Fourteen patients were included, seven in each group (n = 14). The Bonebridge® group showed an average hearing gain in tonal intelligibility thresholds of 32.43 ± 21.39 dB and a gain in the average intelligibility threshold (with 50% discrimination) of 26.29 ± 19.10 dB. In the Osia® group, there was a gain in average tonal thresholds of 41.49 ± 14.16 dB and 23.72 ± 6.98 dB in average intelligibility thresholds. Both devices contributed to improvements in patients' quality of life, as assessed with APHAB in all the variables studied in the test. Both devices offer rehabilitation for hearing loss as an alternative to hearing aids. The Osia® system shows statistically significant (p < 0.05) improvements in mid and high frequencies, but Bonebridge® slightly outperforms in speech understanding at 50%. Differences in average tonal thresholds and quality of life are not statistically significant. CONCLUSIONS: While auditory improvement is observed postimplantation, other aspects, such as intelligibility thresholds and quality of life, lack statistical significance. Given the limited experience with Osia® and the small sample size, the choice of the device should be personalized. Although the literature is inconsistent due to small sample sizes and variable approaches, some studies suggest potential advantages of the Osia® system, especially in speech comprehension in different environments and greater hearing gain compared to Bonebridge®.


Subject(s)
Bone Conduction , Hearing Aids , Hearing Loss, Conductive , Quality of Life , Humans , Retrospective Studies , Middle Aged , Female , Male , Adult , Aged , Hearing Loss, Conductive/rehabilitation , Hearing Loss, Conductive/surgery , Auditory Threshold , Treatment Outcome , Hearing Loss, Sensorineural/surgery , Hearing Loss, Sensorineural/rehabilitation , Speech Perception , Audiometry , Hearing Loss, Mixed Conductive-Sensorineural/rehabilitation , Hearing Loss, Mixed Conductive-Sensorineural/surgery
2.
Audiol Neurootol ; 29(4): 306-321, 2024.
Article in English | MEDLINE | ID: mdl-38447542

ABSTRACT

INTRODUCTION: Active aging emphasizes optimizing health and participation for a better quality of life as people age. This paper explores the significant impact of hearing loss and balance disorders on the elderly. Age-related hearing loss is thought to contribute to communication breakdown and cognitive dysfunctions. The "hearing and balance in healthy aging" project focuses on early detection, mitigation, and advocacy. Objectives include exploring epidemiological traits, evaluating overall well-being impact, proving positive intervention effects, and advocating societal care for the elderly with hearing loss and balance disorders, aiming to reduce their broader impact on cognition, independence, and sociability. METHODS: This study is observational, prospective study. Subjects over 55 years old with a follow-up every year or every 2 years were divided into three groups, according to their hearing and balance: within the normal range (group A), detected and not treated (group B), and detected and treated (group C). At each visit, they underwent a series of tests or questionnaires, evaluating different areas: hearing, balance, cognition, depression, dependence, tinnitus, loneliness, health. RESULTS: A total of 710 patients were included in the study. The distribution of patients was as follows: group A - 210 patients, group B - 302 patients, and group C - 198 patients. Significant differences were found between the three groups related to age, sex, educational level, bilingualism, and work activity. In group C, there was a higher percentage of males, older than in groups A and B, and the percentage of individuals with a university education was lower (28%), as was the rate of bilingualism (23%). In terms of hearing, significant differences were found in the three groups in the mean PTA, speech discrimination in quiet, and the HINT test, with worse results for group C. Only patients in group C presented a perception of hearing impairment, and the handicap caused by hearing impairment worsened from group A to C. Concerning balance, both tests performed (TuGT and DHI) revealed increased difficulty in maintaining autonomous walking from group A to C, which, again, exhibited the worst results, with statistically significant differences across the group. Analysis about cognition revealed significant differences in DSST questionnaires and in TMT scores, where group C had the worst scores. In HUI3 questionnaire scores, the differences between each and every group were statistically significant, with group C showing moderate disability. CONCLUSION: This extensive analysis, encompassing a considerable number of subjects, reveals significant findings that have important implications for the early prevention of hearing loss and its consequent consequences. At the same time, these data represent an initial exploration, which raises the need for in-depth examinations of additional factors and longer follow-up to continue contributing insights and knowledge for a healthy aging.


Subject(s)
Postural Balance , Humans , Male , Female , Aged , Middle Aged , Prospective Studies , Aged, 80 and over , Healthy Aging , Hearing Loss/epidemiology , Quality of Life , Presbycusis/epidemiology , Sensation Disorders/epidemiology , Hearing/physiology
3.
Article in English | MEDLINE | ID: mdl-39179915

ABSTRACT

INTRODUCTION: Superior semicircular canal dehiscence syndrome (SCDS) is a clinical syndrome that can cause instability, vertigo, fullness, tinnitus, autophony, hearing loss (HL), Tullio phenomenon, or Hennebert's sign. Historically, surgery has been the primary treatment reported in the literature, although some medical treatments may also be proposed. This study aims to comprehensively characterize SCDS in a large series of patients from clinical, auditory, and vestibular perspectives, and explore medical alternatives to conventional surgical treatments by comparing their results and evolution. METHODS: A retrospective observational study was designed in a tertiary care center. Audiovestibular tests evaluated included pure-tone audiometry (PTA), VEMPs, video head impulse test (vHIT), and CT imaging. Improvement was assessed over a follow-up period of up to 6 months for seven cardinal symptoms to verify the efficacy of the proposed treatments. RESULTS: 71 subjects with SCDS and a mean age of 51.20 ± 12.22 years were included in the study. The most common symptom found in our sample was instability in 31 patients (43.66%), followed by aural fullness or tinnitus in 29 subjects (40.85%). 36 patients (43.66%) received medical treatment, with 28 of them (77.78%) showing symptom reduction. Surgical repair was indicated in five patients, with all showing symptom improvement. Statistically significant improvement (p < 0.05) was observed, particularly with surgical treatment and acetazolamide, in both symptoms and objective tests such as pure-tone audiometry and VEMPs. CONCLUSION: SCDS shows significant similarities with other otic capsule dehiscences. It is essential to perform VEMPs and CT scans to complete the diagnosis, which is usually accompanied by clearly recognizable clinical criteria. Surgery for SCDS is effective, safe, and without complications. However, in cases where symptoms are mild to moderate, addressing this condition with medical treatment using diuretics such as acetazolamide has shown promising results.

4.
Audiol Neurootol ; : 1-12, 2023 Dec 12.
Article in English | MEDLINE | ID: mdl-38086340

ABSTRACT

INTRODUCTION: The primary objective of this article was to determine if any histological alterations occur in the round window (RW) and adjacent anatomical structures of an animal model with normal hearing when a cochlear implant (CI) electrode array is inserted. Furthermore, this article aims to relate these histological alterations to the auditory changes generated. METHODS: Cochlear implantation was performed, following the principles of minimally traumatic surgery (MTS), in 15 ears of nonhuman primates (Macaca fascicularis) (Mf) with normal hearing. Auditory brainstem-evoked potentials (ABR) using clicks and tones were used prior to surgery and during a 6-month follow-up period. Histological evaluation was carried out, analyzing the position of the electrode array with respect to the round window membrane (RWM), its percentage of occupation and integrity, the presence of intracochlear damage, and the tissue reaction provoked, the latter of which was quantified in the temporal bones. RESULTS: Surgery was performed on all 15 ears without relevant incidences. Regarding histology, the electrode array in the RW of all ears presented a lateral position with respect to the modiolus. No lesions affecting the integrity of the RW were observed. The mean value of the array's occupation in the RW was 25%. Tissue reaction, in the form of fibrosis, was observed in all ears and more intensely in the trans-RWM and post-RWM areas. In all ears, the electrodes remained on the scala tympani. No profound hearing impairment was recorded in any ear, being the mean loss of 25.4 dB when comparing presurgical thresholds with those collected 6 months after implantation in ABR click and 24.4 dB in ABR tone burst. CONCLUSIONS: The animal model and Hybrid L-14 (HL14) electrode array were optimal for implementing a surgical technique similar to that routinely performed on humans. Mild histological alterations were observed in the round window membrane and adjacent anatomical structures from the insertion of a cochlear implant electrode array. Following the minimally invasive technique, levels of hearing preservation were satisfactory, reaching a pre-post difference of 25.4 dB in the ABR click and 24.4 dB for a high-frequency tone burst. Complete hearing impairment was not observed in either ear. Correlation between the severity of histological alterations and hearing changes recorded in the ABR studies was observed.

5.
Eur Arch Otorhinolaryngol ; 279(12): 5591-5600, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35578137

ABSTRACT

PURPOSE: Current studies show that frequency tuning modification is a good marker for the detection of endolymphatic hydrops (EH) employing magnetic resonance imaging (MRI) in patients with Ménière's disease (MD). The purpose of the present study is to analyze the auditory and vestibular function with audiometric and vestibular-evoked myogenic potentials (VEMP) responses, respectively, in both the affected and unaffected ears of patients with unilateral MD using MRI as diagnostic support for the degree of EH. METHODS: We retrospectively reviewed the medical records of 76 consecutive patients with unilateral definite MD (age 55 (28-75); 39 women, 37 men). MRI was used through intravenous gadolinium administration, audiometry, and VEMPs. Functional tests were performed up to a week after the MRI. All were followed up one year after imaging utilizing clinical, auditory, and vestibular testing to rule out bilateral involvement. RESULTS: In the unaffected ear, the mean pure-tone average is normal even in cases with hydrops and, for a similar severity of hydrops is significantly lower than in the affected ear. Significant differences for the amplitude of the response at 0.5 kHz, at 1 kHz between the affected and unaffected ears were found to be lower in the affected ears. The relative amplitude ratio (1 Kz-0.5 kHz) was significantly lower in the affected ear and in the case of the oVEMP response depends on the degree of EH. The response in the unaffected ear was not modified by the presence or the degree of hydrops. CONCLUSION: In the unaffected ear, hydrops is not associated with hearing deterioration. For a similar degree of hydrops, hearing loss is significantly greater in the affected ear. The endolymphatic hydrops in the vestibule induces a frequency bias in the VEMP response only in the affected ear and not in the unaffected ear. Because of these findings we consider that hydrops does not represent an active disorder in the unaffected ear.


Subject(s)
Endolymphatic Hydrops , Meniere Disease , Vestibular Evoked Myogenic Potentials , Male , Humans , Female , Middle Aged , Meniere Disease/complications , Meniere Disease/diagnosis , Retrospective Studies , Endolymphatic Hydrops/diagnosis , Endolymphatic Hydrops/diagnostic imaging , Vestibular Evoked Myogenic Potentials/physiology , Magnetic Resonance Imaging/methods , Edema
6.
Cerebellum ; 20(5): 717-723, 2021 Oct.
Article in English | MEDLINE | ID: mdl-31414248

ABSTRACT

Cerebellar ataxia with neuropathy and vestibular areflexia syndrome (CANVAS) is a recently described slowly progressive ataxia with severe imbalance due to the compromise of three of the four sensory inputs for balance, leaving only vision unaffected. Bilateral vestibulopathy is present but saccular and utricular function, measured by vestibular evoked myogenic potentials (VEMPs), has not been widely studied in these patients. Dysautonomia has been reported but is not among the diagnostic criteria. We performed a database analysis to identify patients evaluated between 2003 and 2019 with probable diagnosis of CANVAS by using key words "bilateral vestibulopathy and/or cerebellar ataxia and/or sensory polyneuropathy." Five out of 842 met all conditions. Patients underwent neurological/neurootological exam, brain MRI, visually enhanced vestibulo-ocular reflex (VVOR) exam by high-speed video-oculography using video-Head Impulse Test (vHIT), VEMPs, neurophysiological studies, and genetic tests to exclude other causes of ataxia. Dysautonomia was addressed by the standardized survey of autonomic symptoms. All patients had clinically definite CANVAS as brain MRI showed vermal cerebellar atrophy, neurophysiological studies showed a sensory neuronopathy pattern (absent sensory action potentials), VVOR was abnormal bilaterally, and genetic tests ruled out other causes of ataxia including SCA 3 and Friedreich ataxia. Patients had at least 3 dysautonomic symptoms, including xerostomia/xerophthalmia (5/5). VEMP results varied among patients, ranging from normal to completely abnormal. We found inconsistent results with VEMPs. The utilization of VEMPs in more CANVAS cases will determine its utility in this syndrome. Dysautonomia may be included in the diagnostic criteria.


Subject(s)
Bilateral Vestibulopathy , Cerebellar Ataxia , Primary Dysautonomias , Vestibular Evoked Myogenic Potentials , Vestibular Neuronitis , Bilateral Vestibulopathy/diagnosis , Bilateral Vestibulopathy/diagnostic imaging , Cerebellar Ataxia/diagnostic imaging , Humans , Primary Dysautonomias/diagnosis , Reflex, Vestibulo-Ocular/physiology
7.
Audiol Neurootol ; 25(1-2): 72-78, 2020.
Article in English | MEDLINE | ID: mdl-31825921

ABSTRACT

OBJECTIVES: Bilateral vestibulopathy is a clinical syndrome in which laboratory testing plays a crucial diagnostic role. We aimed to establish the frequency of detection of that finding in a tertiary level hospital considering the new methods of laboratory vestibular examination nowadays in use, with respect to the conventional caloric and rotatory chair test approaches. DESIGN: Two similar time periods (5 years) were retrospectively evaluated, and the demographic, clinical data and test results from 4,576 patients were reviewed. In the first period, the diagnosis was based on caloric and rotatory chair tests and, in the second, on the video head impulse test. RESULTS: Of the patients included, 3.77% in the first period and 4.58% in the second met the criteria for bilateral vestibular hypofunction; there was no significant difference between both periods. CONCLUSIONS: The functional vestibular evaluation to detect bilateral deficiency makes no significant difference to the number of patients diagnosed with a bilateral vestibulopathy. New diagnostic categories probably depend not only on the availability and accessibility of complete vestibular and visual-vestibular evaluation, but also on recent advances in defining vestibular disorders. Bilateral vestibular hypofunction manifests with very different patterns. Progress in more detailed definition (clinical and laboratory) is needed, in particular when all 6 semicircular canals and both maculae are available for testing.


Subject(s)
Reflex, Vestibulo-Ocular/physiology , Vestibular Diseases/physiopathology , Vestibule, Labyrinth/physiopathology , Aged , Caloric Tests , Female , Head Impulse Test , Humans , Male , Middle Aged , Retrospective Studies , Semicircular Canals/physiopathology
8.
Audiol Neurootol ; 25(1-2): 42-49, 2020.
Article in English | MEDLINE | ID: mdl-31910409

ABSTRACT

BACKGROUND: Histological study of vestibular end organs has been challenging due to the difficulty in preserving their structures for histological analysis and due to their complex geometry. Recently, radiology advances have allowed to deepen the study of the membranous labyrinth. SUMMARY: A review and analysis of surgical implications related to the anatomy of the vestibular end organ is performed. Radiological advances are key in the advancement of the knowledge of the anatomy and pathology of the vestibule. Thus, application of such knowledge in the development or improvement of surgical procedures may facilitate the development of novel techniques. Key Messages: During the last few decades, the knowledge of the anatomy of the auditory system through histology and radiology had improved. Technological advances in this field may lead to a better diagnosis and therapeutic approach of most common and important diseases affecting the inner ear.


Subject(s)
Vestibule, Labyrinth/diagnostic imaging , Humans , Tomography, X-Ray Computed , Vestibule, Labyrinth/pathology , Vestibule, Labyrinth/surgery
9.
Eur Arch Otorhinolaryngol ; 277(6): 1645-1650, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32162058

ABSTRACT

PURPOSE: Since the beginning of cochlear implant (CI) surgery, several techniques to fixate the electrode array at the cochleostomy and stabilize it have been described; however, most techniques use autologous tissues such as fascia, muscle, fat or fibrin glue. We describe a new surgical technique aimed to stabilize the electrode array of a CI without using autologous tissues or artificial materials. MATERIALS AND METHODS: The surgical technique described consists in creating three stabilizing channels in the temporal bone for the electrode array. The first one in a partially opened aditus, the second one in a partially preserved Koerner's septum (KS) and the last one in the sinodural angle. The procedure was performed in five human temporal bones using a straight array; a radiography was made to confirm the correct placement of the electrode array and afterwards all temporal bones were shaken using a Titramax 1000 platform. The correct placement of the array post-shaking was then confirmed using the microscope and another radiography. RESULTS: No migration of the electrodes outside the cochlea was observed. The CI cable remained in the same position at the aditus and the KS in all the temporal bones. In three cases (60%), the electrode array moved away from the groove carved in the sinodural angle. CONCLUSIONS: The new surgical technique described stabilizes the electrode array using the temporal bone's normal anatomy, preserving the middle ear spaces, facilitating the ulterior explantation and reimplantation if necessary, and may reduce cost and surgery time.


Subject(s)
Cochlear Implantation , Cochlear Implants , Cochlea/diagnostic imaging , Cochlea/surgery , Device Removal , Electrodes, Implanted , Humans , Temporal Bone/diagnostic imaging , Temporal Bone/surgery
10.
Eur Arch Otorhinolaryngol ; 277(1): 69-76, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31637478

ABSTRACT

PURPOSE: To compare the surgical and audiological outcomes with two perimodiolar electrode arrays (Nucleus 512-Contour Advance® y Nucleus 532-Slim Perimodiolar®) and a straight electrode array (Nucleus 422/522). METHODS: Patients were retrospectively selected from our cochlear implant program database. Only patients with a history of bilateral, sensorineural postlingually profound hearing loss who underwent cochlear implant surgery with either a N512, a N532 or a N422 were included. Throughout a year of follow-up, pure tone audiometry (PTA), speech perception, Impedances and T-C Thresholds levels were analyzed. Surgical data were also analyzed. RESULTS: 66 patients were included (19-CI532, 20-CI512 and 27-CI422). The most common type of cochlea access with the N532, N512 and N422 was through an extended round window, a promontorial cochleostomy and a pure round window, respectively. No significant differences were observed after 12 months in Mean PTA and Speech recognition. No significant differences were seen in the levels of hearing preservation at frequencies of 250 and 500. The average values of the impedances were significantly higher in the CI group N532 and N422 than in the N512. The mean values of the T and C levels were significantly lower in the CI groups N532 and N422 compared with the N512. CONCLUSIONS: No significant differences were observed after 12 months in Mean PTA and Speech recognition; however, a faster acquisition of auditory results were observed in the group of patients treated with the CI N532. The type of electrode array influences in the type of cochleostomy.


Subject(s)
Cochlea/surgery , Cochlear Implantation/instrumentation , Cochlear Implants , Hearing Loss, Sensorineural/surgery , Adult , Aged , Cochlear Implantation/methods , Female , Hearing Loss, Sensorineural/diagnosis , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies
11.
Ear Hear ; 38(1): e57-e68, 2017.
Article in English | MEDLINE | ID: mdl-27556522

ABSTRACT

OBJECTIVES: The objectives of this study were to evaluate the effect of reimplanting a cochlear implant electrode in animal normal-hearing cochlea to propose measures that may prevent cochlear injury and, given its close phylogenetic proximity to humans, to evaluate the macaque as a model for electroacoustic stimulation. DESIGN: Simultaneous, bilateral surgical procedures in a group of 5 normal-hearing specimens (Macaca fascicularis) took place in a total of 10 ears. Periodic bilateral auditory testing (distortion product otoacoustic emissions and auditory brainstem evoked responses [ABR]) took place during a 6-month follow-up period. Subsequently, unilateral explantation and reimplantation was performed. Auditory follow-up continued up to 12 months, after which animals were sacrificed and both temporal bones extracted for histological analysis. RESULTS: Implantation and reimplantation surgeries were performed without complications in 9 of 10 cases. Full insertion depth was achieved at reimplantation in four of five ears. Auditory evaluation: Statistically significant differences between implanted and reimplanted were observed for the frequencies 2000 and 11,000 Hz, the remaining frequencies showed no differences for distortion product otoacoustic emission. Before the procedure, average thresholds with click-stimuli ABR of the five animals were 40 dB SPL (implanted group) and 40 dB SPL (reimplanted group). One week after first implantation, average thresholds were 55 dB SPL and 60 dB, respectively. After 12 months of follow-up, the average thresholds were 72.5 dB SPL (implanted group) and 65 dB SPL (reimplanted group). Hearing loss appeared during the first weeks after the first implantation and no deterioration was observed thereafter. Differences for ABR under click stimulus were not significant between the two ear groups. Similar results were observed with tone-burst ABR. A 15 dB shift was observed for the implanted group preoperatively versus 1-week post surgery and an additional 17.5 dB shift was seen after 12-month follow-up. For the reimplanted group, a 20 dB shift was observed within the first week post reimplantation surgery and an additional 5 dB after 6 months follow-up. Statistical analysis revealed significant differences between the implanted and reimplanted ear groups for frequencies 4000 Hz (p = 0.034), 12000 Hz (p = 0.031), and 16,000 Hz (p = 0.031). The histological analysis revealed that the electrode insertion was minimally traumatic for the cochlea, mainly indicating rupture of the basilar membrane in the transition area between the basal turn and the first cochlear turn only in Mf1 left ear. CONCLUSIONS: With application of minimally traumatic surgical techniques, it is possible to maintain high rates of hearing preservation after implantation and even after reimplantation. Partial impairment of auditory thresholds may occur during the first weeks after surgery, which remains stable. Considering the tonotopic distribution of the cochlea, we found a correlation between the histological lesions sites and the auditory findings, suggesting that a rupture of the basilar membrane may impact hearing levels. The macaque was observed to be a functionally and anatomically an excellent animal model for cochlear implantation.


Subject(s)
Cochlear Implantation/methods , Cochlear Implants , Device Removal , Hearing Loss/physiopathology , Animals , Cochlea/injuries , Electrodes, Implanted , Evoked Potentials, Auditory, Brain Stem , Macaca fascicularis , Otoacoustic Emissions, Spontaneous , Reoperation/methods
12.
Audiol Neurootol ; 21 Suppl 1: 29-35, 2016.
Article in English | MEDLINE | ID: mdl-27806353

ABSTRACT

The study aim was to determine the benefit of cochlear implantation and hearing aids in older adults diagnosed with hearing loss and to evaluate the index of depression, anxiety and quality of life after such treatments. A retrospective cohort comprised 117 patients older than 65 years and diagnosed with moderate to profound hearing loss who were included and classified into 2 groups (treated vs. non-treated). A battery of tests including auditory (pure-tone average, disyllabic words in quiet at 65 dB SPL) and findings from a series of questions relevant to quality of life were compared between both groups. Auditory outcomes for disyllabic words were 58.21% for the cochlear implant-treated group and 82.8% for the hearing aid-treated group. There was a positive effect on anxiety, depression, health status and quality of life in the cochlear implant group versus the profound hearing loss control group. We conclude that older adults with moderate to profound hearing loss gain benefit from hearing aids or cochlear implants not only in terms of improved hearing function, but also in terms of positive effects on anxiety, depression, health status and quality of life.


Subject(s)
Cochlear Implantation , Deafness/rehabilitation , Depression/psychology , Hearing Aids , Hearing Loss, Sensorineural/rehabilitation , Quality of Life , Aged , Aged, 80 and over , Audiometry, Pure-Tone , Cochlear Implants , Deafness/psychology , Female , Hearing Loss, Sensorineural/psychology , Humans , Male , Retrospective Studies , Severity of Illness Index , Speech Perception
13.
Audiol Neurootol ; 20 Suppl 1: 48-52, 2015.
Article in English | MEDLINE | ID: mdl-25997524

ABSTRACT

This article presents an analysis of the impact of functional neuroimaging studies (positron emission tomography, PET) in asymmetric hearing loss based on the clinical expertise obtained from a group of 21 patients. In these patients, PET studies are performed at rest and after auditory stimulation in order to measure the increase in brain activity in the ipsi- and contralateral cortex, providing supporting evidence to recommend a specific treatment and the side to implant. In conclusion, PET is a useful tool for selected cases in which information on the metabolic status of the auditory pathway can drive the decision regarding the treatment of the most appropriate ear. However, in view of our small sample, further research is needed to confirm our results in this topic.


Subject(s)
Auditory Cortex/diagnostic imaging , Auditory Pathways/diagnostic imaging , Hearing Loss, Unilateral/diagnostic imaging , Acoustic Stimulation , Adult , Aged , Auditory Cortex/physiopathology , Auditory Pathways/physiopathology , Brain/diagnostic imaging , Brain/physiopathology , Cochlear Implantation , Female , Functional Neuroimaging , Hearing Loss, Unilateral/physiopathology , Hearing Loss, Unilateral/rehabilitation , Humans , Male , Middle Aged , Positron-Emission Tomography , Young Adult
14.
Article in English | MEDLINE | ID: mdl-38823774

ABSTRACT

INTRODUCTION AND OBJECTIVES: Even though the incidence has decreased in recent years, Down syndrome (DS) remains the most common chromosomal disorder today. Despite being a condition with multisystemic involvement, it often tends to affect the head and neck area, making it a frequent reason for consultation with pediatric otolaryngologists or otologists. The purpose of this work is to be one of the first in Spain to characterize and describe the pathology and therapeutic approach typically provided to these patients, analyzing the evolution from a clinical and auditory perspective. MATERIAL AND METHODS: We aim to analyze a sample of 16 pediatric patients recruited over the past 24 years, diagnosed with Down syndrome, and experiencing a wide range of diseases affecting the ear and its auditory function. RESULTS: 62.50% of the patients were women, whose main reason for seeking specialist care was acute and serous otitis media, accounting for 31.25%. These patients have an indication for treatment for various entities within the otological sphere that usually do not differ from those of a healthy child. However, the evolution and response to treatments can take on a torpid character due to the anatomical characteristics of the ears of these patients. CONCLUSIONS: Although the frequency of children with DS in the pediatric otolaryngologist's clinic is decreasing, these patients have a predisposition to ear diseases with auditory repercussions, with variable evolution depending on the disease and the child's intrinsic characteristics.


Subject(s)
Down Syndrome , Humans , Down Syndrome/complications , Female , Male , Child , Child, Preschool , Adolescent , Ear Diseases/etiology , Ear Diseases/epidemiology , Infant , Otitis Media with Effusion/complications , Otitis Media with Effusion/etiology , Spain/epidemiology
15.
Audiol Res ; 14(4): 721-735, 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-39194417

ABSTRACT

BACKGROUND: Middle ear active implants, such as the Vibrant Soundbridge (VSB), offer an alternative to reconstructive surgery and other implantable hearing aid systems for patients with conductive, mixed, or sensorineural hearing loss. The primary objective of this work is to describe the auditory results obtained with VSB in our patient cohort, measuring the auditory gain in terms of average tonal thresholds and spoken word discrimination at 65 dB. Secondly, auditory gain differences between different types of hearing loss, coupling to the ossicular chain compared to round and oval windows, and the impact of open versus more conservative surgical approaches, were analyzed. METHODS: A cross-sectional observational study, with retrospective data collection, was conducted at a tertiary care center. Clinical and audiometric data pre- and post-implantation were included, from patients who underwent VSB device placement surgery between 2001 and 2024. RESULTS: 55 patients with an average age of 62.58 ± 17.83 years and a slight preference in terms of the female gender (52.72%) were included in the study. The average gain in the PTA for all types of hearing loss was 41.56 ± 22.63 dB, while for sensorineural hearing loss (SNHL) the gain was 31.04 ± 8.80 dB. For mixed-conductive hearing loss (C-MHL) a gain of 42.96 ± 17.70 was achieved, notably, in terms of absolute values, at frequencies of 4000 and 6000 Hz, with gains reaching 49.25 ± 20.26 dB at 4 K and 51.16 ± 17.48 dB at 6 K. In terms of spoken word discrimination, for all types of hearing loss, an improvement of 75.20 ± 10.11% was achieved. However, patients with C-MHL exhibited an approximately 13% higher gain compared to those with SNHL (69.32 ± 24.58% vs. 57.79 ± 15.28%). No significant differences in auditory gain were found between open and closed surgical techniques, nor in the proportion of adverse effects, when comparing one technique with the other. CONCLUSIONS: The VSB is effective in improving hearing in patients with mixed, conductive, and sensorineural hearing loss, with significant gains at high frequencies, especially through the round window membrane approach. The choice of surgical technique should consider the patient's anatomical characteristics and specific needs in order to optimize auditory outcomes and minimize postoperative complications.

16.
Front Neurol ; 15: 1363481, 2024.
Article in English | MEDLINE | ID: mdl-38469594

ABSTRACT

Introduction: Cochlear implantation is currently regarded as a safe and minimally invasive procedure. However, cochlear implantation can have an impact on vestibular function, despite the lack of correlation between patient symptomatology and damage in vestibular tests. Thus, the present study aims to analyze the presence of hydrops and histological reactions at the level of the vestibule after cochlear implantation with dexamethasone pump delivery in Macaca fascicularis (Mf). Materials and methods: A detailed histological study was conducted on a total of 11 Mf. All 11 Mf were divided into three groups: 5 Mf were implanted with an electrode array HL-14 connected to a pump delivering FITC-dextran for 24 h (Group A); 4 Mf were implanted with a CI electrode array attached to a pump for FITC-dextran delivery for 7 days (Group B); and 2 Mf were considered the control group, without any kind of cochlear device implantation (Group C). After drug deliver, the selected macaques were euthanized to collect tissue samples for histological analysis. An experienced observer, focusing on the utricle and saccule areas, conducted a blinded inner ear histology analysis. Results: Surgical procedures were successfully performed in all cases. No signs of cochlear reaction to the device were observed, including neither collapse nor fibrosis. Endolymphatic sinus dilatation was observed in Mf4A and Mf3B, while cochlear hydrops was observed in Mf3A. The mean areas of the utricle and saccule exhibited some statistically significant differences, specifically, in the saccule between groups C and both groups A (p = 0.028) and B (p = 0.029); however, no significant differences were observed between groups A and B or among comparisons of the utricle. Discussion: A significant concern relates to the safety of cochlear implantation with regard to vestibular preservation and hearing. New advancements in electrode arrays, such as CI devices coupled with delivery pumps, pose a challenge in maintaining minimally traumatic surgical concept-based procedures without affecting the inner ear homeostasis. The implantation of this device may cause vestibular hydrops in the saccule, indicating that the longer the time of substance release, the greater the grade of hydrops evidenced at the saccular level. Apart from this finding, the risk of histological damage to the vestibule is low.

17.
Audiol Res ; 14(2): 372-385, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38666903

ABSTRACT

INTRODUCTION: We present a series of six cases whose clinical presentations exhibited audiovestibular manifestations of a third mobile window mechanism, bearing a reasonable resemblance to Ménière's disease and otosclerosis. The occurrence of these cases in such a short period has prompted a review of the underlying causes of its development. Understanding the pathophysiology of third mobile window syndrome and considering these entities in the differential diagnosis of conditions presenting with vertigo and hearing loss with slight air-bone gaps is essential for comprehending this group of pathologies. MATERIALS AND METHODS: A descriptive retrospective cohort study of six cases diagnosed at a tertiary center. All of them went through auditive and vestibular examinations before and after a therapeutic strategy was performed. RESULTS: Out of 84 cases of dehiscences described in our center during the period from 2014 to 2024, 78 belonged to superior semicircular canal dehiscence, while 6 were other otic capsule dehiscences. Among these six patients with a mean age of 47.17 years (range: 18-73), all had some form of otic capsule dehiscence with auditory and/or vestibular repercussions, measured through hearing and vestibular tests, with abnormalities in the results in five out of six patients. Two of them were diagnosed with Ménière's disease (MD). Another two had cochleo-vestibular hydrops without meeting the diagnostic criteria for MD. In two cases, the otic capsule dehiscence diagnosis resulted from an intraoperative complication due to a gusher phenomenon, while in one case, it was an accidental radiological finding. All responded well to the proposed treatment, whether medical or surgical, if needed. CONCLUSIONS: Otic capsule dehiscences are relatively new and unfamiliar entities that should be considered when faced with cases clinically suggestive of Ménière's disease, with discrepancies in complementary tests or a poor response to treatment. While high-sensitivity and specificity audiovestibular tests exist, completing the study with imaging, especially petrous bone CT scans, is necessary to locate and characterize the otic capsule defect responsible for the clinical presentation.

18.
Audiol Res ; 14(4): 701-713, 2024 Aug 14.
Article in English | MEDLINE | ID: mdl-39194415

ABSTRACT

BACKGROUND: Audiovestibular disorders in childhood occur with considerable frequency. However, the difficulty of obtaining medical history, the nonspecificity of symptoms, and the lack of cooperation during complementary tests often contribute significantly to diagnostic biases, attributing clinical presentations to psychosomatic disorders. The objectives of this work are, firstly, to characterize, from an auditory and vestibular perspective, the most frequent causes of vertigo in childhood and a possible relationship with emotional symptoms. On the other hand, to propose the usefulness of the MSSQ-Short questionnaire as a predictive variable in the evolution of children diagnosed with recurrent vertigo of childhood (RVC). METHODS: An observational cross-sectional study was designed with retrospective data collection at three tertiary hospitals. RESULTS: Among the 117 patients recruited between 2016 and 2024, 32 patients (27.35%) were diagnosed with an anxious-depressive syndrome prior to audiovestibular testing. The mean age was 11.19 ± 5.61 years and the most frequent final diagnoses were vestibular migraine (VM) with 41.03% and RVC with 23.93%. Patients with VM, compared with RVC, are approximately 1.12 times more likely to have psychosomatic pathology (CI 0.39 to 3.25). The most sensitive and frequently altered test was VEMPS (39.32%), with statistical significance in VM and otic capsule dehiscence, while regarding the MSSQ-Short questionnaire, the linear regression of 0.28 indicates an increase in clinical duration with high questionnaire scores. CONCLUSIONS: Vestibular disorders causing dizziness and vertigo are challenging to diagnose, often due to lack of cooperation and/or symptom nonspecificity. A thorough medical history and complementary tests, including audiovestibular and imaging studies, are advisable, thus avoiding systematically attributing children's complaints to other psychosomatic disorders.

19.
Life (Basel) ; 14(4)2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38672742

ABSTRACT

BACKGROUND: Age-related hearing loss (ARHL) is a complex communication disorder that affects the cochlea and central auditory pathway. The goal of this study is to characterize this type of hearing loss and to identify non-invasive, inexpensive, and quick tests to detect ARHL among elderly adults, seeking to preserve quality of life and reduce the burden on healthcare systems. METHODS: An observational, prospective study is conducted with >55-year-old subjects divided into the following groups: normal range (Group A), detected but not treated (Group B), and detected and treated (Group C). During follow-up, Speech Spatial Qualities (SSQ12), and Hearing Handicap Inventory in the Elderly Screening test (HHIE-S) questionnaires were assessed, along with hearing levels (hearing thresholds at 4 kHz were studied in more depth), and a series of tests and questionnaires to assess balance, cognitive level, level of dependence, and depression. RESULTS: A total of 710 patients were included in this study. The duration of hearing loss (11.8 yr. in Group B and 21.0 yr. in Group C) and average time-to-treatment for Group C (14.1 yr.) are both protracted. Both of the used questionnaires show statistically significant differences among the groups, revealing greater handicaps for Group C. Audiometry performed at 4 kHz shows how hearing loss progresses with age, finding differences between men and women. There is a correlation between time-to-treatment in Group C and the cognitive test DSST (-0.26; p = 0.003). CONCLUSIONS: HHIE-S, SSQ12, and 4 kHz audiometry are sensitive and feasible tests to implement in screening programs.

20.
J Clin Med ; 13(9)2024 Apr 28.
Article in English | MEDLINE | ID: mdl-38731116

ABSTRACT

Background: Cholesteatoma is a lesion capable of destroying surrounding tissues, which may result in significant complications. Surgical resection is the only effective treatment; however, the presence of cholesteatoma recidivism is common. This study evaluated the effectiveness of the Attic Exposure-Antrum Exclusion (AE-AE) surgical technique in treating cholesteatomas and identifying factors associated with recidivism. Additionally, the study aimed to assess the utility of non-echo-planar diffusion MRI (non-EPI-DWI MRI) in detecting cholesteatoma recidivism in patients undergoing AE-AE surgery. Methods: The study involved 63 patients who underwent AE-AE surgery for primary acquired cholesteatoma and were followed up clinically and radiologically for at least five years. The radiological follow-up included a non-EPI-DWI MRI. Results: Results showed that the AE-AE technique successfully treated cholesteatomas, with a recidivism rate of 5.2%. The study also found that non-EPI-DWI MRI was a useful diagnostic tool for detecting cholesteatoma recidivism, although false positives could occur due to the technique's high sensitivity. As Preoperative Pure-tone average (PTA) increases, there is a higher probability of cholesteatoma recidivism in imaging tests (p = 0.003). Conclusions: Overall, the study highlights the importance of the AE-AE surgical technique and non-EPI-DWI MRI in managing cholesteatoma recidivism in patients, providing valuable insights into associated risk factors and how to manage recidivism. Non-EPI-DWI MRI can assist in patient selection for revision surgery, reducing unnecessary interventions and associated risks while improving treatment outcomes and patient care.

SELECTION OF CITATIONS
SEARCH DETAIL