Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Journal subject
Affiliation country
Publication year range
1.
J Magn Reson Imaging ; 52(3): 731-738, 2020 09.
Article in English | MEDLINE | ID: mdl-32144848

ABSTRACT

BACKGROUND: Patient head motion is a major concern in clinical brain MRI, as it reduces the diagnostic image quality and may increase examination time and cost. PURPOSE: To investigate the prevalence of MR images with significant motion artifacts on a given clinical scanner and to estimate the potential financial cost savings of applying motion correction to clinical brain MRI examinations. STUDY TYPE: Retrospective. SUBJECTS: In all, 173 patients undergoing a PET/MRI dementia protocol and 55 pediatric patients undergoing a PET/MRI brain tumor protocol. The total scan time of the two protocols were 17 and 40 minutes, respectively. FIELD STRENGTH/SEQUENCES: 3 T, Siemens mMR Biograph, MPRAGE, DWI, T1 and T2 -weighted FLAIR, T2 -weighted 2D-FLASH, T2 -weighted TSE. ASSESSMENT: A retrospective review of image sequences from a given clinical MRI scanner was conducted to investigate the prevalence of motion-corrupted images. The review was performed by three radiologists with different levels of experience using a three-step semiquantitative scale to classify the quality of the images. A total of 1013 sequences distributed on 228 MRI examinations were reviewed. The potential cost savings of motion correction were estimated by a cost estimation for our country with assumptions. STATISTICAL TEST: The cost estimation was conducted with a 20% lower and upper bound on the model assumptions to include the uncertainty of the assumptions. RESULTS: 7.9% of the sequences had motion artifacts that decreased the interpretability, while 2.0% of the sequences had motion artifacts causing the images to be nondiagnostic. The estimated annual cost to the clinic/hospital due to patient head motion per scanner was $45,066 without pediatric examinations and $364,242 with pediatric examinations. DATA CONCLUSION: The prevalence of a motion-corrupted image was found in 2.0% of the reviewed sequences. Based on the model, repayment periods are presented as a function of the price for applying motion correction and its performance. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 6 J. Magn. Reson. Imaging 2020;52:731-738.


Subject(s)
Magnetic Resonance Imaging , Neuroimaging , Artifacts , Brain/diagnostic imaging , Child , Humans , Motion , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL