Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 162
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Article in English | MEDLINE | ID: mdl-39077791

ABSTRACT

AIMS: We aimed to evaluate transcatheter mitral valve implantation (TMVI) using predominantly balloon-expandable transcatheter heart valves (THV) in patients with a landing zone for a percutaneously delivered prosthesis. BACKGROUND: Patients with a degenerated mitral valve bioprosthesis, annuloplasty ring, and mitral annulus calcification (MAC) considered at high surgical risk currently represent a treatment challenge. TMVI is an alternative treatment option. METHODS: Retrospective analysis of patients with symptomatic degenerated mitral valve bioprosthesis, or annuloplasty ring, and MAC treated with TMVI between November 2011 and April 2021. Endpoints were defined according to Mitral Valve Academic Research Consortium (MVARC) criteria and included device and procedure success at 30 days as well as mortality at 30 days and 1 year after the procedure. RESULTS: A total of 77 patients underwent TMVI (valve in valve [ViV = 56], valve in ring [ViR = 11], and valve in MAC [ViMAC = 10]). There was a trend toward higher technical success (all = 93.5%, ViV = 96.4%, ViR = 90.9%, ViMAC = 80%, p = 0.06) and lower 30-day (all = 11.7%, ViV = 10.7%, ViR = 9.1%, ViMAC = 20%, p = 0.49) and 1-year mortality (all = 26%, ViV = 23.2%, ViR = 27.3%, ViMAC= 40%, p = 0.36) after ViV and ViR compared to ViMAC. CONCLUSION: TMVI represents a reasonable treatment option in selected patients with MAC or who are poor candidates for redo mitral valve surgery. Technical success and survival up to 1 year were not significantly dependent on the subgroup in which TMVI was performed.

2.
Am Heart J ; 264: 114-122, 2023 10.
Article in English | MEDLINE | ID: mdl-37315878

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as a standard treatment for high-operative risk patients with severe aortic stenosis (AS). Although coronary artery disease (CAD) often coexists with AS, clinical and angiographic evaluations of stenosis severity are unreliable in this specific setting. To provide precise risk stratification of coronary lesions, combined near-infrared spectroscopy and intravascular ultrasound (NIRS-IVUS) was developed to integrate morphological and molecular information on plaque composition. However, there is a lack of evidence on the association between NIRS-IVUS derived findings such as maximum 4mm lipid core burden index (maxLCBI4mm) and clinical outcomes in AS patients undergoing TAVI. This registry aims to assess feasibility and safety of NIRS-IVUS imaging in the setting of routine pre-TAVI coronary angiography to improve assessment of CAD severity. METHODS: The registry is designed as a non-randomized, prospective, observational, multicenter cohort registry. Patients referred for TAVI with angiographic evidence of CAD receive NIRS-IVUS imaging and are followed up to 24 months. Enrolled patients are classified as NIRS-IVUS positive and NIRS-IVUS negative, respectively, based on their maxLCBI4mm to compare their clinical outcomes. The primary endpoint of the registry is major adverse cardiovascular events over a 24-month follow-up period. CONCLUSIONS: Identification of patients likely or unlikely to benefit from revascularization prior to TAVI represents an important unmet clinical need. This registry is designed to investigate whether NIRS-IVUS-derived atherosclerotic plaque characteristics can identify patients and lesions at risk for future adverse cardiovascular events after TAVI, in order to refine interventional decision-making in this challenging patient population.


Subject(s)
Coronary Artery Disease , Plaque, Atherosclerotic , Transcatheter Aortic Valve Replacement , Humans , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Spectroscopy, Near-Infrared/methods , Prospective Studies , Ultrasonography, Interventional/methods , Coronary Angiography , Registries
3.
Catheter Cardiovasc Interv ; 102(7): 1301-1310, 2023 12.
Article in English | MEDLINE | ID: mdl-37877190

ABSTRACT

BACKGROUND: Permanent pacemaker implantation (PPI) remains a relevant complication after transcatheter aortic valve implantation (TAVI) and its impact on outcome remains controversial. AIMS: This study aimed to analyze the effects of implantation depth on PPI at 30 days and assess its impact on outcome with the balloon-expandable Sapien 3 (S3) prosthesis. METHODS: Between 2014 and 2018, 849 patients without previous pacemaker undergoing transfemoral TAVI with the S3 were included. Prosthesis implantation depth was measured and divided into Quintiles. An ordinal logistic regression was used to assess its association with PPI, while a multivariate logistic regression was performed to identify predictors of PPI. Survival analyses were performed with the Kaplan-Meier method and a multivariable Cox regression was performed to ascertain the impact of PPI on mortality. RESULTS: Overall, incidence of PPI at 30 days was 9.7%. Implantation depth decreased consistently from a median of 6.7 mm [5.55-8.00] in 2014 to 2.7 mm [2.30-3.50] in 2018 (p < 0.001). When considering Quintiles of implantation depth, incidence of PPI was significantly higher in upper Quintiles and risk for PPI was significantly lower for the 1. Quintile compared to the 5. Quintile (OR: 0.34, 95% CI: [0.16-0.73]; p = 0.003). In the adjusted multivariable logistic regression implantation depth persisted ad independent predictor of PPI at 30 days. Patients requiring PPI at 30 days displayed significantly higher mortality at 4 years compared to patients without PPI (49.5% vs. 40.0%; log-rank = 0.022). In a multivariate analysis, increased logistic EuroScore, diabetes mellitus, and history of atrial fibrillation, were independent predictors of all-cause mortality at 2 years. CONCLUSIONS: Higher prosthesis implantation relative to the virtual aortic annulus was significantly associated with reduced risk for PPI at 30 days. Patients with PPI at 30 days exhibited higher mortality during follow-up, however, only logistic EuroScore, diabetes mellitus, and history of atrial fibrillation were identified as independent predictors of mortality at 2 years.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Diabetes Mellitus , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Atrial Fibrillation/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Heart Valve Prosthesis/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Risk Factors
4.
Catheter Cardiovasc Interv ; 101(3): 628-638, 2023 02.
Article in English | MEDLINE | ID: mdl-36709496

ABSTRACT

OBJECTIVES: To investigate the feasibility and safety of percutaneous transluminal angioplasty (PTA) of the iliofemoral arteries (IFA) before transfemoral transcatheter aortic valve implantation (Tf-TAVI) in patients with advanced peripheral artery disease (PAD). BACKGROUND: Although Tf-TAVI represents the access of choice, alternative vascular access routes are preferred for patients displaying advanced PAD. PTA of the IFA represents a less invasive option, broadening the spectrum of patients eligible for Tf-TAVI. METHODS: All patients requiring PTA of the IFA before Tf-TAVI, between 2012 and 2021, were included. Primary efficacy endpoint was the rate of successful transcatheter heart valve (THV) delivery and implantation. Primary safety endpoint was the rate of PTA and access-site-related vascular complications, procedural- and in-hospital complications. RESULTS: Among 2726 Tf-TAVI procedures, 59 patients required IFA predilation. Successful THV delivery and implantation was achieved in 57 (96.6%) patients, respectively. Sheath placement was achieved in 59 (100%) patients with only one minor dissection and no major vascular complications following iliofemoral PTA. Regarding access site complications, two (3.4%) vessel perforations and one (1.7%) vessel rupture were observed, with eight (13.5%) patients requiring unplanned endovascular interventions. There was one intraprocedural death due to THV-induced vessel laceration, while in-hospital all-cause mortality was 8.5% in the present high-risk patient cohort. CONCLUSIONS: Predilation of IFA is safe and effective in patients with advanced PAD. Careful preprocedural planning is paramount in improving procedural safety and efficacy. This strategy has the potential to broaden the spectrum of patients eligible for Tf-TAVI.


Subject(s)
Aortic Valve Stenosis , Peripheral Arterial Disease , Transcatheter Aortic Valve Replacement , Humans , Treatment Outcome , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Peripheral Arterial Disease/complications
5.
J Card Surg ; 36(4): 1241-1248, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33484180

ABSTRACT

PURPOSE: The Sentinel Cerebral Protection System (Sentinel-CPS) is increasingly used in transcatheter aortic valve replacement (TAVR). However, the impact of inserting the Sentinel-CPS inside the brain-supplying arteries on cerebral perfusion and oxygenation is unknown. METHODS: Twenty patients undergoing transfemoral TAVR with (n = 10) and without (n = 10) cerebral embolic protection using the Sentinel-CPS were prospectively observed. All patients received conscious sedation and cerebral oxygen saturation (rSO2 ) was continuously measured with near-infrared spectroscopy (NIRS). The cumulative perioperative cerebral desaturation was calculated for each patient by multiplying rSO2 below an individualized desaturation threshold by time. In addition, rSO2 values at the time of Sentinel-CPS insertion, filter positioning, and device retraction were analyzed. RESULTS: There was no significant difference in cumulative cerebral desaturation in patients with Sentinel-CPS (median [IQR]) (0 [0/81] s%) and without (median [IQR]) (0 [0/23] s%), p = .762. A total of 6 patients (33.3%) experienced a perioperative decrease in rSO2 below the individualized desaturation threshold (n = 3 with Sentinel-CPS, n = 3 without Sentinel-CPS; p = 1.000). Cerebral desaturation was detected during valve deployment (n = 5) and after postdilatation (n = 1). No desaturation events occurred during Sentinel-CPS insertion, filter positioning, or retraction. CONCLUSION: Our pilot study revealed no difference in cumulative perioperative cerebral desaturation between TAVR with and without Sentinel-CPS. Catheter- and filter-based manipulations in the brain-supplying arteries for Sentinel-CPS application were not associated with a decrease of cerebral perfusion and oxygenation.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Oxygen , Pilot Projects , Prospective Studies , Treatment Outcome
6.
Heart Lung Circ ; 29(6): 904-913, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31182269

ABSTRACT

AIM: Psoas muscle cross-sectional area (CSA) is a proposed marker of frailty associated with mortality after transcatheter aortic valve implantation (TAVI). We assessed the impact of psoas CSA on medium-term mortality over 5 years in a large cohort, adjusted for pre-procedural variables. METHOD: This single-centre registry-derived analysis assessed 1,731 consecutive TAVI patients between 2007 and 31 April 2015 with available abdominal computed tomography scans. Sex-stratified, height-adjusted psoas CSA was measured mid-body of the fourth lumbar vertebra. Kaplan-Meier survival distributions across psoas CSA quartiles were compared. Cox and logistic regression models were used to assess baseline variables associated with the primary outcome, which was mortality within 5 years. RESULTS: Median age was 81 years (interquartile range, 77 - 85); 52.5% were women. The primary endpoint occurred in 555 patients over a mean follow-up of 775 days. Lower psoas CSA quartile patients were older, had a lower body mass index, lower creatinine clearance, and lower rates of previous cardiac surgery, with higher rates of diabetes, coronary artery disease, pacemaker, anaemia, hypoalbuminaemia, and higher European System for Cardiac Operative Risk Evaluation (EuroSCORE). Unadjusted survival by psoas CSA quartile was significantly different in men (log rank p=0.041) but not women (p=0.099). In Bonferroni-adjusted multivariate analysis, psoas CSA quartiles were not significantly associated with mortality. Hypoalbuminaemia (hazard ratio [HR], 2.10; 95% confidence interval [CI], 1.53 - 2.87 [p<0.001]) and increasing age (HR, 1.03 per year; 95% CI, 1.01 - 1.05 [p=0.002]) were associated with increased risk; female sex (HR, 0.63; 95% CI 0.51 - 0.78 [p<0.001]), and hypercholesterolaemia (HR, 0.67; 95%, CI 0.54 0.83 [p<0.001]) with reduced risk. CONCLUSIONS: Psoas CSA was not significantly associated with mortality after adjusting for pre-procedural variables. Hypoalbuminaemia, sex, hypercholesterolaemia, and age were significantly associated with mortality after TAVI.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Psoas Muscles/diagnostic imaging , Registries , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Female , Follow-Up Studies , Germany/epidemiology , Humans , Male , Psoas Muscles/surgery , Retrospective Studies , Risk Factors , Survival Rate/trends , Time Factors , Tomography, X-Ray Computed , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
7.
Anaesthesist ; 69(10): 712-716, 2020 10.
Article in German | MEDLINE | ID: mdl-32780181

ABSTRACT

The intensive medical care of COVID-19 patients presents the deployed personnel with as yet unknown challenges. For example, protective equipment is now being extensively used, which was otherwise only used in selected situations. Working in such an environment is to be evaluated differently under the aspect of occupational safety than other patient care, especially as more than 1900 suspected cases of a SARS-CoV-19 occupational disease were reported among healthcare workers in Germany. Even in a pandemic, the legal requirements remain valid and personal protective equipment (PPE) has to comply with given standards. The use of FFP3 masks is required in aerosol-forming situations, such as endotracheal intubation or bronchoscopy. In contrast to surgical face masks, there is a maximum wearing time for FFPs masks. Furthermore, in a pandemic there is a basic danger of PPE shortage and recycling of face masks is under discussion. Therefore, usage of non-EU certified PPE may come into effect but this has to follow the requirements defined by European regulations. The aim of this article is to provide an overview of the currently relevant rules and regulations in Germany.


Subject(s)
Coronavirus Infections/prevention & control , Infection Control/legislation & jurisprudence , Infectious Disease Transmission, Patient-to-Professional/prevention & control , Pandemics/prevention & control , Personal Protective Equipment/standards , Pneumonia, Viral/prevention & control , Betacoronavirus/isolation & purification , COVID-19 , Coronavirus Infections/transmission , Germany , Health Personnel , Humans , Infection Control/standards , Occupational Health , Patient Care , Pneumonia, Viral/transmission , SARS-CoV-2
8.
Catheter Cardiovasc Interv ; 94(6): 783-792, 2019 Nov 15.
Article in English | MEDLINE | ID: mdl-30801906

ABSTRACT

OBJECTIVES: To evaluate 1-year outcome using the ACURATE neo (Symetis S.A., a Boston Scientific Company, Ecublens, Switzerland) according to the updated Valve Academic Research Consortium (VARC-2) with emphasis on the composite endpoints "clinical efficacy after 30 days" and "time-related valve safety". BACKGROUND: Initial reports on the clinical performance of patients treated with the ACURATE neo are promising; however, information regarding one-year outcome is scarce, especially with regard to the composite endpoints proposed by the VARC-2. METHODS: One hundred and fifty one consecutive patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) with the ACURATE neo for severe aortic valve stenosis were enrolled. Data were prospectively collected and event rates during follow-up were calculated as the Kaplan-Meier estimates. RESULTS: Mean age was 81.1 ± 5.9 years and 49.7% (75/151) were female with a median logistic EuroScore of 13.8% [8.2-20.5]. Device success was achieved in 88.1% (133/151) and procedure related mortality was 0.7% (1/151). At one-year, all-cause mortality was 3.3% (5/151), while permanent pacemaker implantation occurred in 12.7% (19/151) of patients. The "clinical efficacy after 30 days" was observed in 24.8% (37/151), where the main contributor was symptom worsening in 14.8% (22/151) of cases. "Time-related valve safety" occurred in 22.0% (33/151) with structural valve deterioration as main contributor in 10.7% (16/151) of cases. CONCLUSIONS: Using the ACURATE neo, we found a favorable safety profile with low all-cause mortality at 1 year. The reported VARC-2 defined composite endpoints at 1 year reveal low rates of "clinical efficacy after 30 days" and "time-related valve safety".


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Male , Prospective Studies , Prosthesis Design , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 92(1): 141-148, 2018 07.
Article in English | MEDLINE | ID: mdl-29130582

ABSTRACT

OBJECTIVES: The aim of this investigation was to identify patient's characteristics and periprocedural variables related to periprocedural transfusion in transfemoral Transcatheter Aortic Valve Implantation (tf-TAVI). BACKGROUND: Transfusion of allogenic red-blood cells (RBC) in tf-TAVI and the number of transfused units has been linked to an increased 30-day mortality. In line with the trend of minimization and cost-effectiveness, transfusion should be avoided, wherever possible. METHODS: Between 2007 and 2015, 1,734 procedures were analyzed from our prospective registry for RBC-transfusion. Multiple logistic regression analysis was used to identify the dependent variables. RESULTS: Transfusion was considered necessary in 14% (n = 243) of the patients. Female gender (OR [95% CI]) (1.680 [1.014-2.783]) and preprocedural moderate (7.594 [4.404-13.095]) and severe anemia (8.202 [0.900-74.752]) according to WHO were the most important preprocedural variables. Periprocedural, pericardial effusion (12.109 [3.753-39.063]), emergency extracorporeal circulation (54.5288 [6.178-481.259]) and major vascular injury (2.647 [1.412-4.962]) were related to transfusion. The same applies to moderate (4.255 [1.859-9.740]) and severe anemia (31.567 [8.560-116.416]) as well as periprocedural experience (0.072 [0.035-0.149] - 0.141[0.079-0.251], P < 0.001) CONCLUSION: Procedural experience, serious adverse events, low pre- and periprocedural Hb levels and female gender were the main variables relating to transfusion. Even in experienced high-volume centers, transfusion is still necessary in a considerable number of patients.


Subject(s)
Anemia/therapy , Aortic Valve/surgery , Catheterization, Peripheral/methods , Erythrocyte Transfusion , Femoral Artery , Heart Valve Diseases/surgery , Perioperative Care/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Anemia/blood , Anemia/complications , Anemia/diagnosis , Biomarkers/blood , Catheterization, Peripheral/adverse effects , Erythrocyte Transfusion/adverse effects , Female , Heart Valve Diseases/complications , Heart Valve Diseases/diagnosis , Hemoglobins/metabolism , Humans , Male , Perioperative Care/adverse effects , Punctures , Registries , Risk Factors , Sex Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 92(1): 149-156, 2018 07.
Article in English | MEDLINE | ID: mdl-29130616

ABSTRACT

BACKGROUND: Although the incidence of periprocedural complications has decreased in transcatheter aortic valve implantation (TAVI), life-threatening complications occur and emergency veno-arterial extracorporeal membrane oxygenation (vaECMO) can provide immediate circulatory stabilization. We report our two-center experience of vaECMO during life-threatening complications in TAVI. METHODS: From January 2010 to December 2015, 1,810 consecutive patients underwent TAVI at two centers. Clinical characteristics, type of complication, outcome and temporal trends in the requirement of emergency vaECMO were evaluated. RESULTS: Life-threatening complications requiring vaECMO occurred in 1.8% of cases (33 patients; 22 transfemoral, 11 transapical). Indications for vaECMO were ventricular rupture (30%, 10/33), low output (15%, 5/33), bleeding (12%, 4/33), coronary artery impairment (9%, 3/33), ventricular arrhythmias (6%, 2/33), severe aortic regurgitation (6%, 2/33), aortic annular rupture (6%, 2/33), and aortic dissection (3%, 1/33). In 4 cases, no definite cause for hemodynamic instability was identified. Conversion to open heart surgery was necessary in 42% of patients (14/33). Percutaneous coronary intervention was performed in all cases with coronary artery impairment (9%, 3/33). Patients with severe aortic regurgitation (6%, 2/33) underwent emergency valve-in-valve implantation. Other patients received, in addition to vaECMO support conservative treatment (42%, 14/33). In-hospital mortality and 30-day mortality were 46% (15/33). Of patients discharged, 67% (12/18) had no neurological impairment, whereas mild and severe neurological impairment was found in 11% (2/18) and 22% (4/18), respectively. From 2010 to 2015, with increasing procedures (from n = 43 to n = 553) requirement of vaECMO decreased from 9.3% to 0.9% (P for the trend <0.001). CONCLUSION: Over a 6-year period, need for emergency vaECMO during TAVI significantly decreased over time. Despite high in-hospital mortality, vaECMO represents a feasible strategy for hemodynamic support in case of life-threatening complications.


Subject(s)
Aortic Valve/surgery , Extracorporeal Membrane Oxygenation , Heart Valve Diseases/surgery , Postoperative Complications/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Emergencies , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/mortality , Female , Germany , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/mortality , Heart Valve Diseases/physiopathology , Hospital Mortality , Humans , Incidence , Male , Postoperative Complications/diagnosis , Postoperative Complications/mortality , Retrospective Studies , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
11.
Biomarkers ; 23(3): 299-304, 2018 May.
Article in English | MEDLINE | ID: mdl-29297708

ABSTRACT

PURPOSE: Elevated carbohydrate antigen 125 (CA125) predicts adverse outcome after transcatheter aortic valve implantation (TAVI). While known underlying pathophysiological mechanisms of elevated CA125 include serosal effusions and inflammatory stimuli, clinical determinants associated with elevated CA125 in patients referred for TAVI remain unknown. Therefore, we investigated clinical, laboratory and echocardiographic determinants of elevated CA125 in patients with severe aortic valve stenosis referred for TAVI. METHODS: This study includes 650 patients with severe aortic stenosis referred for TAVI. Baseline CA125 was determined by an immunoassay and dichotomized (elevated versus normal) based on the manufacturer cutoff value (>35 U/mL). RESULTS: CA125 elevation was present in 28% (181/650). Patients with elevated CA125 had an overall worse clinical profile and were more symptomatic with a higher rate of NYHA class III/IV (80% versus 58%; p < 0.001). In a multivariate analysis, independent predictors of elevated CA125 were New York Heart Association (NYHA) class, baseline hemoglobin, C-reactive protein (CRP), left ventricular ejection fraction and severe tricuspid regurgitation. CONCLUSION: Elevated CA125 levels in patients referred for TAVI summarize a subset of patients with an overall worse clinical profile who are more symptomatic.


Subject(s)
Aortic Valve Stenosis/blood , CA-125 Antigen/blood , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve Stenosis/surgery , C-Reactive Protein , Hemoglobins , Humans , Risk Assessment , Risk Factors , Tricuspid Valve Insufficiency , Ventricular Function, Left
12.
Can J Anaesth ; 65(6): 647-657, 2018 06.
Article in English | MEDLINE | ID: mdl-29464420

ABSTRACT

PURPOSE: Different sedation regimens have been described for use during transfemoral transcatheter aortic valve implantation (tf-TAVI) for treatment in patients with severe aortic stenosis. The purpose of this study was to compare dexmedetomidine (DEX) with a combination of propofol-opioid (PO) with respect to periprocedural gas exchange and hemodynamic support. METHODS: Data from a cohort of patients sedated with either DEX or PO for tf-TAVI were retrospectively analyzed from a prospectively maintained TAVI registry. Operative risk was determined from comorbidities and risk scores. Periprocedural partial pressure of carbon dioxide (PaCO2) was chosen as the primary endpoint. Other differences in gas exchange, need for catecholamine therapy, the frequency of conversion to general anesthesia, and need for sedative "rescue therapy" (in DEX patients) were secondary endpoints. Inverse probability of treatment weighting (IPTW) was used for analysis to minimize any selection bias. RESULTS: Of the 297 patients (140 PO, 157 DEX) included, the median [interquartile range] periprocedural PaCO2 values of DEX patients were significantly lower than in PO patients (40 [36-45] mmHg vs 44 [40-49] mmHg, respectively; median difference -4 mmHg; 95% confidence interval, -5 to -3 mmHg; P < 0.001). Hypercapnia (PaCO2 > 45 mmHg) was significantly less frequent in DEX patients compared with the PO group (25% vs 42%, respectively; P = 0.005). Vasopressor support was more frequent in the PO group compared with DEX (68% vs 25%, respectively; P < 0.001). Conversion to general anesthesia was not different between groups (9%, PO vs 3%, DEX; P = 0.051). Additional sedatives/opioids were required in 25 (16%) of the DEX patients. CONCLUSIONS: In sedated TAVI patients, DEX was associated with lower PaCO2 values and reduced requirements for vasopressor support, making it a promising alternative to PO for sedation during TAVI. TRIAL REGISTRATION: www.ClinicalTrials.gov (NCT01390675). Registered 11 July 2011.


Subject(s)
Analgesics, Opioid , Conscious Sedation/methods , Dexmedetomidine , Hypnotics and Sedatives , Propofol , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Anesthesia, General , Aortic Valve Stenosis/surgery , Carbon Dioxide/blood , Cohort Studies , Endpoint Determination , Female , Hemodynamics , Humans , Male , Pulmonary Gas Exchange , Retrospective Studies , Risk Assessment
13.
Br J Anaesth ; 116(1): 90-9, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26424178

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a treatment strategy for patients with severe aortic stenosis. Although general anaesthesia (TAVI-GA) and sedation (TAVI-S) have previously been described for TAVI, the difference in safety and efficacy of both methods has not been studied in a randomized trial. METHODS: The INSERT trial was a single centre, controlled parallel-group trial with balanced randomization. Sixty-six patients (68-94 yr) with acquired aortic stenosis undergoing transfemoral CoreValve™ were assigned to TAVI-GA or TAVI-S. Comparable operative risk was determined from risk-scores (EUROscore, STS-Score). Monitoring and anaesthetic drugs were standardized. Near-Infrared-Spectroscopy was used to monitor cerebral-oxymetry blinded. Primary outcome was the perioperative cumulative cerebral desaturation. As secondary outcomes, changes in neurocognitive function and respiratory and haemodynamic adverse events were evaluated. RESULTS: Of 66 included patients, 62 (TAVI-GA: n=31, TAVI-S: n=31) were finally analysed. Baseline characteristics were comparable. In 24 patients (39%) cerebral desaturation was observed. Cumulative cerebral desaturation was comparable (TAVI-GA:(median [IQR]) (0[0/1308] s%) vs. TAVI-S:(0[0/276] s%); P=0.505) between the groups. Neurocognitive function did not change within and between groups. Adverse events were more frequently observed in TAVI-S patients (P<0.001). Bradypnoea (n=16, 52%) and the need for airway manoeuvres (n=11, 36%) or bag-mask-ventilation (n=6, 19%) were the most common respiratory adverse events. CONCLUSIONS: Cerebral desaturation occurred in both patient groups, but there was no significant difference between the two groups. Based on primary outcome, both methods were shown to be comparable. Neurocognitive outcome was similar. The higher incidence of adverse events in the sedation group suggests a potential advantage of general anaesthesia. CLINICAL TRIAL REGISTRATION: NCT 01251328.


Subject(s)
Anesthesia, General/adverse effects , Brain/drug effects , Cognition Disorders/chemically induced , Deep Sedation/adverse effects , Oxygen/blood , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Brain/physiopathology , Female , Humans , Male , Neuropsychological Tests/statistics & numerical data , Oximetry/statistics & numerical data , Risk Factors , Spectrophotometry, Infrared , Treatment Outcome
14.
Ultraschall Med ; 37(3): 271-6, 2016 Jun.
Article in English | MEDLINE | ID: mdl-25876222

ABSTRACT

PURPOSE: To evaluate different sonographic signs of strangulating closed-loop obstruction retrospectively. MATERIALS AND METHODS: Over a period of approximately 10 years all documents, US scans and video clips of patients with strangulating intestinal obstruction were reviewed. The following sonographic signs were evaluated: akinetic bowel loops; echo-free luminal content; hyperechoic congestion of the mesentery; free peritoneal fluid; bowel wall thickening; signs of ischemia on color Doppler or contrast-enhanced US. Moreover, we looked for signs of bowel obstruction proximal to the closed loop and for the width of the strangulated segment. RESULTS: The most often documented features of strangulating closed-loop obstruction were an akinetic bowel loop (94 %), a hyperechoic and thickened mesentery (82 %) and free peritoneal fluid (100 %). In 54 % of cases the luminal content was almost anechoic. In 76 % of patients bowel wall thickening and in 50 % signs of ischemia on color Doppler or contrast-enhanced US were documented. In 67 % small bowel dilatation proximal to the strangulated bowel segment was present. The width of the strangulated bowel loops was 2.86 cm on average. CONCLUSION: The akinetic bowel loops, hyperechoic thickening of the attached mesentery and free peritoneal fluid are typical for strangulating closed-loop obstruction. An anechoic luminal content is only visible in about half of the patients, but this eye-catcher can lead the investigator to the correct diagnosis. In about one third of patients no signs of bowel obstruction proximal to the strangulated loops are present. Dilatation of the strangulated loop may be absent or mild.


Subject(s)
Intestinal Obstruction/diagnostic imaging , Ultrasonography , Female , Gastrointestinal Motility/physiology , Humans , Intestine, Small/blood supply , Intestine, Small/diagnostic imaging , Ischemia/diagnostic imaging , Male , Mesentery/diagnostic imaging , Multimodal Imaging , Tomography, X-Ray Computed , Ultrasonography, Doppler, Color
16.
Clin Res Cardiol ; 113(2): 276-287, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37870627

ABSTRACT

OBJECTIVES: Systemic inflammatory response syndrome (SIRS) is a common finding after cardiovascular interventions. Data on the incidence of SIRS and its impact on outcome in patients undergoing transcatheter edge-to-edge mitral valve repair (MV-TEER) for mitral regurgitation (MR) is lacking. METHODS: From January 2013 to December 2020, 373 patients with moderate or severe MR undergoing MV-TEER were included. SIRS was defined as at least two of the following criteria within 48 h after the procedure: leucocyte count > 12.0 or < 4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 bpm and temperature > 38.0 °C or < 36.0 °C. The primary endpoint was 3-years all-cause mortality. RESULTS: SIRS was observed in 49.6% (185/373) of patients. Patients who developed SIRS presented more frequently with NYHA III/IV at baseline [SIRS: 82.4% (149/185) vs. no SIRS: 79.0% (147/188); p = 0.029]. Patients who developed SIRS spent more days on ICU (p < 0.001) and overall length of stay was longer (p < 0.001). Relevant residual MR, defined as MR ≥ III in-hospital, was present more often in patients who developed SIRS [SIRS: 11.3% (20/177) vs. no SIRS: 3.93% (7/178), p = 0.036]. At 3 years, all-cause mortality in the entire population was 33.5% (125/373) with an increased all-cause mortality in patients with SIRS compared to patients without SIRS (HR 1.49, [CI 95% 1.04, 2.13]; p = 0.0264). In the multivariate analysis development of SIRS (HR 1.479 [CI 95% 1.016, 2.154]; p = 0.041) was identified as predictor for 3-years all-cause mortality. CONCLUSIONS: SIRS is a common finding after MV-TEER occurring in approximately half of patients. SIRS after MV-TEER was associated with a longer in-hospital stay. In addition, we observed an increased 3-years all-cause mortality in patients with SIRS.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Incidence , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Systemic Inflammatory Response Syndrome/diagnosis , Systemic Inflammatory Response Syndrome/epidemiology , Systemic Inflammatory Response Syndrome/etiology , Heart Rate , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/epidemiology , Mitral Valve Insufficiency/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects
17.
Br J Anaesth ; 110(4): 615-21, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23213034

ABSTRACT

BACKGROUND: Once aprotinin was no longer available for clinical use, ε-aminocaproic acid (EACA) and tranexamic acid became the only two options for antifibrinolytic therapy. We compared aprotinin and EACA with respect to their blood-sparing efficacy and other major clinical outcome criteria in infants undergoing cardiac surgery. METHODS: We retrospectively analysed data from a large consecutive cohort of infants (n=227) aged 31-365 days undergoing primary cardiac surgery requiring cardiopulmonary bypass encompassing the transition from aprotinin to EACA (aprotinin n=88, EACA n=139); all other aspects including the medical team and departmental protocols remained unchanged. The primary outcome was postoperative blood loss measured as chest tube output (CTO). Secondary outcome parameters were transfusion requirements, reoperation due to bleeding, renal, vascular, and neurological complications, and in-hospital mortality. RESULTS: CTO was significantly higher in the EACA patients {aprotinin 18 (13-27) ml kg(-1) 24 h(-1), EACA 23 (15-37) ml kg(-1) 24 h(-1) [mean (inter-quartile range)], P=0.001}, but transfusion requirements and donor exposures were not significantly different. A sensitivity analysis strengthened our finding that the increased blood loss in the EACA group was attributable to lower efficacy of EACA. There were no significant differences in the other clinical outcome measures. CONCLUSIONS: CTO was lower in aprotinin-treated patients. Nonetheless, EACA remains a suitable substitute without measurable differences in other clinical outcome criteria.


Subject(s)
Aminocaproic Acid/therapeutic use , Aprotinin/therapeutic use , Blood Loss, Surgical/prevention & control , Cardiac Surgical Procedures/methods , Hemostatics/therapeutic use , Blood Transfusion/statistics & numerical data , Chest Tubes , Coronary Artery Bypass , Female , Hospital Mortality , Humans , Infant , Male , Patient Safety , Postoperative Complications/epidemiology , Risk Adjustment , Treatment Outcome
18.
Article in English | MEDLINE | ID: mdl-38065713

ABSTRACT

BACKGROUND: Data on systemic inflammatory response syndrome (SIRS) after transcatheter aortic valve implantation (TAVI) are scarce and limited to small cohorts. We aimed to investigate its incidence and mid-term impact in a large cohort of TAVI patients. METHODS: From January 2018 to December 2020, 717 patients with severe aortic valve stenosis undergoing TAVI were included. SIRS was defined as fulfilling at least two of the following criteria within 48 h from the procedure: leucocyte count >12.0 or <4.0 × 109/l, respiratory rate > 20 breaths per minute or PaCO2 ≤ 4.3 kPa/32 mmHg, heart rate > 90 beats per minute and temperature > 38.0 °C or <36.0 °C. Clinical endpoints were 1-year rehospitalization for chronic heart failure (CHF) and 2-years all-cause mortality. Event rates during follow-up were calculated as Kaplan-Meier estimates. RESULTS: SIRS developed in 56.3 % (404/717) of patients after TAVI. SIRS occurred more frequently in patients with post-dilatation (SIRS 34.7 % (140/404) vs. no SIRS 23.3 % (73/313); p < 0.001) and major vascular complications (SIRS 16.1 % (65/404) vs. no SIRS 8.6 % (27/313); p = 0.004). Further, ICU days were more in patients who developed SIRS (SIRS 1.56 ± 1.50 days vs. no SIRS 1.22 ± 1.02 days; p = 0.001). At 2-years, all-cause mortality in the entire population was 23.9 %. However, there was no difference in CHF at 1-year (5.9 % vs. 4.1 %; log-rank = 0.347) nor in all-cause mortality at 2-years (22.0 % vs. 26.2 %; log-rank = 0.690) between the groups. CONCLUSIONS: SIRS is a common finding after TAVI, which may prolong hospital stay but is without effect on mortality during 2-years follow-up.

19.
Int J Cardiol Heart Vasc ; 49: 101312, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38076344

ABSTRACT

Objectives: Data on anesthetic proceedings during cardiac implantable electronic device (CIED) implant procedures are scarce and it remains unclear whether anesthetic care is still required in selected patients. Methods: In this retrospective, single center study we assessed the prevalence of intraoperative anesthetic management comprising anesthetic standby, sedation or general anesthesia as well as anesthetic and procedural complications. We analyzed pre-existing and perioperative risk factors related to procedure-related adverse outcome such as perioperative cardiopulmonary resuscitation (CPR) and 30-day mortality in a uni- and multivariable analysis. Results: In total, PM and ICD insertion were performed in up to 85% and 58% under anesthetic standby, with an increasing tendency over time.Overall, Cardiopulmonary resuscitation (CPR) was required in 59 patients. Acute heart failure (AHF) was the only independent pre-existing risk factor for CPR and for 30-day mortality. Sedation and general anesthesia had a significantly increased odds ratio for CPR compared to anesthetic standby. The risk for CPR significantly decreased during the study period. Conclusions: Over the years anesthetic practice during CIED implant procedures shifted from mixed anesthetic proceedings to mainly standby duties. The prevalence of complications and emergency measures is low, however not uncommon. Accordingly, the presence of an anesthesiologist should be further guaranteed when sedatives were titrated and in AHF patients. However, in patients receiving local anesthetic infiltration only, it seems safe to perform CIED implant procedures without anesthetic standby.

20.
Eur Heart J Cardiovasc Imaging ; 24(5): 574-587, 2023 04 24.
Article in English | MEDLINE | ID: mdl-36735333

ABSTRACT

AIMS: Patients with mitral regurgitation (MR) present with considerable heterogeneity in cardiac damage depending on underlying aetiology, disease progression, and comorbidities. This study aims to capture their cardiopulmonary complexity by employing a machine-learning (ML)-based phenotyping approach. METHODS AND RESULTS: Data were obtained from 1426 patients undergoing mitral valve transcatheter edge-to-edge repair (MV TEER) for MR. The ML model was developed using 609 patients (derivation cohort) and validated on 817 patients from two external institutions. Phenotyping was based on echocardiographic data, and ML-derived phenotypes were correlated with 5-year outcomes. Unsupervised agglomerative clustering revealed four phenotypes among the derivation cohort: Cluster 1 showed preserved left ventricular ejection fraction (LVEF; 56.5 ± 7.79%) and regular left ventricular end-systolic diameter (LVESD; 35.2 ± 7.52 mm); 5-year survival in Cluster 1, hereinafter serving as a reference, was 60.9%. Cluster 2 presented with preserved LVEF (55.7 ± 7.82%) but showed the largest mitral valve effective regurgitant orifice area (0.623 ± 0.360 cm2) and highest systolic pulmonary artery pressures (68.4 ± 16.2 mmHg); 5-year survival ranged at 43.7% (P-value: 0.032). Cluster 3 was characterized by impaired LVEF (31.0 ± 10.4%) and enlarged LVESD (53.2 ± 10.9 mm); 5-year survival was reduced to 38.3% (P-value: <0.001). The poorest 5-year survival (23.8%; P-value: <0.001) was observed in Cluster 4 with biatrial dilatation (left atrial volume: 312 ± 113 mL; right atrial area: 46.0 ± 8.83 cm2) although LVEF was only slightly reduced (51.5 ± 11.0%). Importantly, the prognostic significance of ML-derived phenotypes was externally confirmed. CONCLUSION: ML-enabled phenotyping captures the complexity of extra-mitral valve cardiac damage, which does not necessarily occur in a sequential fashion. This novel phenotyping approach can refine risk stratification in patients undergoing MV TEER in the future.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/surgery , Ventricular Function, Left , Stroke Volume , Treatment Outcome , Retrospective Studies , Phenotype , Heart Valve Prosthesis Implantation/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL