Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters

Database
Language
Publication year range
1.
J Infect Dis ; 214(12): 1897-1904, 2016 Dec 15.
Article in English | MEDLINE | ID: mdl-27923950

ABSTRACT

BACKGROUND: Usually, immunoglobulin M (IgM) serologic analysis is not sufficiently specific to confirm Zika virus (ZIKV) infection. However, since IgM does not cross the placenta, it may be a good marker of infection in neonates. METHODS: We tested blood from 42 mothers and neonates with microcephaly and collected cerebrospinal fluid (CSF) specimens from 30 neonates. Molecular assays were performed for detection of ZIKV, dengue virus, and chikungunya virus; IgM enzyme-linked immunosorbent assays and plaque-reduction neutralization tests (PRNTs) were performed to detect ZIKV and dengue virus. No control neonates without microcephaly were evaluated. RESULTS: Among neonates, all 42 tested positive for ZIKV IgM: 38 of 42 serum specimens (90.5%) were positive, whereas 30 of 30 CSF specimens (100%) were positive. ZIKV IgM-specific ELISA ratios, calculated as the mean optical density (OD) of the test sample when reacted on viral antigen divided by the mean OD of the negative control when reacted with viral antigen, were higher in CSF specimens (median, 14.9 [range, 9.3-16.4]) than in serum (median, 8.9 [range, 2.1-20.6]; P = .0003). All ZIKV IgM-positive results among the neonates were confirmed by the detection of neutralizing antibodies. Mother/neonate pairs with primary ZIKV infection had neutralizing antibodies to ZIKV only, and mother/neonate pairs with ZIKV virus infection secondary to infection with another flavivirus had high titers of neutralizing antibodies to ZIKV. Among secondary infections, median titers in serum were 2072 (range, 232-12 980) for mothers and 2730 (range, 398-12 980) for neonates (P < .0001), and the median titer in CSF was 93 (range, 40-578) among neonates (P < .0001). CONCLUSIONS: Among neonates, detection of ZIKV IgM in serum is confirmatory of congenital ZIKV infection, and detection of ZIKV IgM in CSF is confirmatory of neurologic infection. Therefore, we recommend testing for ZIKV IgM in neonates suspected of having congenital ZIKV infection and performance of PRNTs in equivocal cases.


Subject(s)
Antibodies, Neutralizing/blood , Antibodies, Neutralizing/cerebrospinal fluid , Antibodies, Viral/blood , Antibodies, Viral/cerebrospinal fluid , Immunoglobulin M/blood , Zika Virus Infection/diagnosis , Zika Virus/immunology , Adolescent , Adult , Blood/immunology , Cerebrospinal Fluid/immunology , Enzyme-Linked Immunosorbent Assay , Female , Humans , Infant, Newborn , Male , Neutralization Tests , Sensitivity and Specificity , Viral Plaque Assay , Young Adult , Zika Virus Infection/congenital
SELECTION OF CITATIONS
SEARCH DETAIL