Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Sensors (Basel) ; 22(11)2022 May 26.
Article in English | MEDLINE | ID: mdl-35684656

ABSTRACT

This work presents an overview of the main strategies that have been proposed for non-invasive monitoring of heart rate (HR) in extramural and home settings. We discuss three categories of sensing according to what physiological effect is used to measure the pulsatile activity of the heart, and we focus on an illustrative sensing modality for each of them. Therefore, electrocardiography, photoplethysmography, and mechanocardiography are presented as illustrative modalities to sense electrical activity, mechanical activity, and the peripheral effect of heart activity. In this paper, we describe the physical principles underlying the three categories and the characteristics of the different types of sensors that belong to each class, and we touch upon the most used software strategies that are currently adopted to effectively and reliably extract HR. In addition, we investigate the strengths and weaknesses of each category linked to the different applications in order to provide the reader with guidelines for selecting the most suitable solution according to the requirements and constraints of the application.


Subject(s)
Electrocardiography , Photoplethysmography , Heart Rate/physiology , Monitoring, Physiologic
2.
Physiol Meas ; 45(3)2024 Mar 12.
Article in English | MEDLINE | ID: mdl-38387047

ABSTRACT

Objective.Wearable devices that measure vital signals using photoplethysmography are becoming more commonplace. To reduce battery consumption, computational complexity, memory footprint or transmission bandwidth, companies of commercial wearable technologies are often looking to minimize the sampling frequency of the measured vital signals. One such vital signal of interest is the pulse arrival time (PAT), which is an indicator of blood pressure. To leverage this non-invasive and non-intrusive measurement data for use in clinical decision making, the accuracy of obtained PAT-parameters needs to increase in lower sampling frequency recordings. The aim of this paper is to develop a new strategy to estimate PAT at sampling frequencies up to 25 Hertz.Approach.The method applies template matching to leverage the random nature of sampling time and expected change in the PAT.Main results.The algorithm was tested on a publicly available dataset from 22 healthy volunteers, under sitting, walking and running conditions. The method significantly reduces both the mean and the standard deviation of the error when going to lower sampling frequencies by an average of 16.6% and 20.2%, respectively. Looking only at the sitting position, this reduction is even larger, increasing to an average of 22.2% and 48.8%, respectively.Significance.This new method shows promise in allowing more accurate estimation of PAT even in lower frequency recordings.


Subject(s)
Blood Pressure Determination , Wearable Electronic Devices , Humans , Blood Pressure Determination/methods , Blood Pressure/physiology , Heart Rate , Photoplethysmography/methods
SELECTION OF CITATIONS
SEARCH DETAIL