ABSTRACT
OBJECTIVE: This systematic review of literature aimed to evaluate the safety and efficacy of dual-chamber ICDs for LBBAP in patients with left bundle branch block (LBBB). METHODS: Digital databases were searched systematically to identify studies reporting the left bundle branch area pacing (LBBAP) with implantable cardioverter defibrillator (ICD) placement in patients with LBBB. Detailed study and patient-level baseline characteristics including the type of study, sample size, follow-up, number of cases, age, gender, and baseline characteristics were abstracted. RESULTS: In a total of three studies, 34 patients were included in this review. There was a significant improvement reported in QRS duration in all studies. The mean QRS duration at baseline was 170 ± 17.4 ms, whereas the follow-up QRS duration at follow-up was 121 ± 17.3 ms. Two studies reported a significant improvement of 50% in LVEF from baseline. No lead-related complications or arrhythmic events were recorded in any study. The findings of the systematic review suggest that dual-chamber ICD for LBBAP is a promising intervention for patients with heart conditions. CONCLUSION: The procedure offers significant improvements in QRS duration and LVEF, and there were no lead-related complications or arrhythmic events recorded in any of the studies.