Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Clin Chem Lab Med ; 2024 May 17.
Article in English | MEDLINE | ID: mdl-38753471

ABSTRACT

OBJECTIVES: Even in the current era of hematology analyzer automation and peripheral equipment, quality control sample measurement remains a manual task, leading to variability in quality control data and increased workload. In this study, we evaluated the performance of quality control measurement using the BT-50 Transportation Unit (BT-50, Sysmex, Kobe, Japan), equipped with a scheduled automatic quality control function, to ensure measurement accuracy and streamline the workflow of hematology testing. METHODS: We evaluated the automatic measurement performance of quality control samples using the BT-50 for six representative blood test parameters: WBC (white blood cell), RBC (red blood cell), HGB (hemoglobin), HCT (hematocrit), PLT (platelet), and RET% (reticulocyte percent). We evaluated the equivalence and compared measurement accuracy between the BT-50 and the manual method. We then compared the variability to other laboratories and confirmed the stability of quality control samples. We also evaluated changes in workflow and staff resources before and after the introduction of the BT-50. RESULTS: The quality control measurement results for the BT-50 and the manual method were found to be equivalent for all six parameters. The variability measured by the BT-50 was lower for some parameters compared to the manual method. Furthermore, the workflow was streamlined by reducing manual processes, resulting in increased efficiency. CONCLUSIONS: We confirmed the performance of quality control measurements using the schedule function of the BT-50. Introducing the BT-50 reduced the operator's workload, improved operational efficiency, and promoted the standardization of quality control measurements.

2.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38489836

ABSTRACT

OBJECTIVES: After staged reconstruction for hypoplastic left heart syndrome, the neoaortic root tends to dilate, and the incidence of significant neoaortic valve insufficiency increases with time. This study aimed to evaluate the mid-term outcomes of the neoaortic root geometries and valve function after chimney reconstruction in the Norwood procedure. METHODS: Between 2013 and 2021, 20 consecutive patients who underwent chimney reconstruction during the Norwood procedure for hypoplastic left heart syndrome and its variants in our institution were enrolled. The actual diameters of the following points were measured, and Z-scores were calculated based on the normal aortic root geometries using the long axis view of echocardiography at the pre-Norwood stage and the lateral view of angiography at pre-Glenn, pre-Fontan, post-Fontan and follow-up (age 5-6 years) stages: neoaortic valve annulus; sinus of Valsalva; sinotubular junction; and ascending aorta just proximal to the anastomosis to the aortic arch. The degree of neoaortic valve regurgitation was evaluated by echocardiography at each stage. RESULTS: The median follow-up period was 3.9 years. Neoaortic roots after chimney reconstruction were spared from progressive dilation over time. With growth, the conical configuration of the neoaortic roots was preserved without geometrical distortion. The Z-scores of the annulus, sinus of Valsalva, sinotubular junction and ascending aorta ranged roughly from 4 to 6, 4 to 6, 2 to 4 and 0 to 2, respectively. All neoaortic valves at each stage had mild or no regurgitation. CONCLUSIONS: Chimney reconstruction prevented neoaortic root dilation and avoided significant neoaortic valve regurgitation in the mid-term. These neoaortic dimensions with smooth flow profiles in the neoaorta after chimney reconstruction may have contributed to the current results. Further studies are needed to clarify the long-term outcomes.


Subject(s)
Aortic Valve Insufficiency , Hypoplastic Left Heart Syndrome , Norwood Procedures , Humans , Child, Preschool , Child , Hypoplastic Left Heart Syndrome/surgery , Treatment Outcome , Norwood Procedures/adverse effects , Aorta/surgery , Echocardiography , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Follow-Up Studies , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL