Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 120
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Pathol ; 262(3): 310-319, 2024 03.
Article in English | MEDLINE | ID: mdl-38098169

ABSTRACT

Deep learning applied to whole-slide histopathology images (WSIs) has the potential to enhance precision oncology and alleviate the workload of experts. However, developing these models necessitates large amounts of data with ground truth labels, which can be both time-consuming and expensive to obtain. Pathology reports are typically unstructured or poorly structured texts, and efforts to implement structured reporting templates have been unsuccessful, as these efforts lead to perceived extra workload. In this study, we hypothesised that large language models (LLMs), such as the generative pre-trained transformer 4 (GPT-4), can extract structured data from unstructured plain language reports using a zero-shot approach without requiring any re-training. We tested this hypothesis by utilising GPT-4 to extract information from histopathological reports, focusing on two extensive sets of pathology reports for colorectal cancer and glioblastoma. We found a high concordance between LLM-generated structured data and human-generated structured data. Consequently, LLMs could potentially be employed routinely to extract ground truth data for machine learning from unstructured pathology reports in the future. © 2023 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.


Subject(s)
Glioblastoma , Precision Medicine , Humans , Machine Learning , United Kingdom
2.
Eur Radiol ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627289

ABSTRACT

OBJECTIVES: Large language models (LLMs) have shown potential in radiology, but their ability to aid radiologists in interpreting imaging studies remains unexplored. We investigated the effects of a state-of-the-art LLM (GPT-4) on the radiologists' diagnostic workflow. MATERIALS AND METHODS: In this retrospective study, six radiologists of different experience levels read 40 selected radiographic [n = 10], CT [n = 10], MRI [n = 10], and angiographic [n = 10] studies unassisted (session one) and assisted by GPT-4 (session two). Each imaging study was presented with demographic data, the chief complaint, and associated symptoms, and diagnoses were registered using an online survey tool. The impact of Artificial Intelligence (AI) on diagnostic accuracy, confidence, user experience, input prompts, and generated responses was assessed. False information was registered. Linear mixed-effect models were used to quantify the factors (fixed: experience, modality, AI assistance; random: radiologist) influencing diagnostic accuracy and confidence. RESULTS: When assessing if the correct diagnosis was among the top-3 differential diagnoses, diagnostic accuracy improved slightly from 181/240 (75.4%, unassisted) to 188/240 (78.3%, AI-assisted). Similar improvements were found when only the top differential diagnosis was considered. AI assistance was used in 77.5% of the readings. Three hundred nine prompts were generated, primarily involving differential diagnoses (59.1%) and imaging features of specific conditions (27.5%). Diagnostic confidence was significantly higher when readings were AI-assisted (p > 0.001). Twenty-three responses (7.4%) were classified as hallucinations, while two (0.6%) were misinterpretations. CONCLUSION: Integrating GPT-4 in the diagnostic process improved diagnostic accuracy slightly and diagnostic confidence significantly. Potentially harmful hallucinations and misinterpretations call for caution and highlight the need for further safeguarding measures. CLINICAL RELEVANCE STATEMENT: Using GPT-4 as a virtual assistant when reading images made six radiologists of different experience levels feel more confident and provide more accurate diagnoses; yet, GPT-4 gave factually incorrect and potentially harmful information in 7.4% of its responses.

3.
Skeletal Radiol ; 53(4): 791-800, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37819279

ABSTRACT

OBJECTIVE: Clinical-standard MRI is the imaging modality of choice for the wrist, yet limited to static evaluation, thereby potentially missing dynamic instability patterns. We aimed to investigate the clinical benefit of (dynamic) real-time MRI, complemented by automatic analysis, in patients with complete or partial scapholunate ligament (SLL) tears. MATERIAL AND METHODS: Both wrists of ten patients with unilateral SLL tears (six partial, four complete tears) as diagnosed by clinical-standard MRI were imaged during continuous active radioulnar motion using a 1.5-T MRI scanner in combination with a custom-made motion device. Following automatic segmentation of the wrist, the scapholunate and lunotriquetral joint widths were analyzed across the entire range of motion (ROM). Mixed-effects model analysis of variance (ANOVA) followed by Tukey's posthoc test and two-way ANOVA were used for statistical analysis. RESULTS: With the increasing extent of SLL tear, the scapholunate joint widths in injured wrists were significantly larger over the entire ROM compared to those of the contralateral healthy wrists (p<0.001). Differences between partial and complete tears were most pronounced at 5°-15° ulnar abduction (p<0.001). Motion patterns and trajectories were altered. Complete SLL deficiency resulted in complex alterations of the lunotriquetral joint widths. CONCLUSION: Real-time MRI may improve the functional diagnosis of SLL insufficiency and aid therapeutic decision-making by revealing dynamic forms of dissociative instability within the proximal carpus. Static MRI best differentiates SLL-injured wrists at 5°-15° of ulnar abduction.


Subject(s)
Carpal Joints , Joint Instability , Wrist Injuries , Humans , Wrist Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Carpal Joints/diagnostic imaging , Ligaments, Articular/diagnostic imaging , Magnetic Resonance Spectroscopy , Joint Instability/diagnostic imaging , Wrist Injuries/diagnostic imaging
4.
Radiology ; 307(5): e222223, 2023 06.
Article in English | MEDLINE | ID: mdl-37278629

ABSTRACT

Background Deep learning (DL) models can potentially improve prognostication of rectal cancer but have not been systematically assessed. Purpose To develop and validate an MRI DL model for predicting survival in patients with rectal cancer based on segmented tumor volumes from pretreatment T2-weighted MRI scans. Materials and Methods DL models were trained and validated on retrospectively collected MRI scans of patients with rectal cancer diagnosed between August 2003 and April 2021 at two centers. Patients were excluded from the study if there were concurrent malignant neoplasms, prior anticancer treatment, incomplete course of neoadjuvant therapy, or no radical surgery performed. The Harrell C-index was used to determine the best model, which was applied to internal and external test sets. Patients were stratified into high- and low-risk groups based on a fixed cutoff calculated in the training set. A multimodal model was also assessed, which used DL model-computed risk score and pretreatment carcinoembryonic antigen level as input. Results The training set included 507 patients (median age, 56 years [IQR, 46-64 years]; 355 men). In the validation set (n = 218; median age, 55 years [IQR, 47-63 years]; 144 men), the best algorithm reached a C-index of 0.82 for overall survival. The best model reached hazard ratios of 3.0 (95% CI: 1.0, 9.0) in the high-risk group in the internal test set (n = 112; median age, 60 years [IQR, 52-70 years]; 76 men) and 2.3 (95% CI: 1.0, 5.4) in the external test set (n = 58; median age, 57 years [IQR, 50-67 years]; 38 men). The multimodal model further improved the performance, with a C-index of 0.86 and 0.67 for the validation and external test set, respectively. Conclusion A DL model based on preoperative MRI was able to predict survival of patients with rectal cancer. The model could be used as a preoperative risk stratification tool. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Langs in this issue.


Subject(s)
Deep Learning , Rectal Neoplasms , Male , Humans , Middle Aged , Retrospective Studies , Rectal Neoplasms/diagnostic imaging , Rectal Neoplasms/therapy , Magnetic Resonance Imaging , Risk Factors
5.
Radiology ; 307(3): e222211, 2023 05.
Article in English | MEDLINE | ID: mdl-36943080

ABSTRACT

Background Reducing the amount of contrast agent needed for contrast-enhanced breast MRI is desirable. Purpose To investigate if generative adversarial networks (GANs) can recover contrast-enhanced breast MRI scans from unenhanced images and virtual low-contrast-enhanced images. Materials and Methods In this retrospective study of breast MRI performed from January 2010 to December 2019, simulated low-contrast images were produced by adding virtual noise to the existing contrast-enhanced images. GANs were then trained to recover the contrast-enhanced images from the simulated low-contrast images (approach A) or from the unenhanced T1- and T2-weighted images (approach B). Two experienced radiologists were tasked with distinguishing between real and synthesized contrast-enhanced images using both approaches. Image appearance and conspicuity of enhancing lesions on the real versus synthesized contrast-enhanced images were independently compared and rated on a five-point Likert scale. P values were calculated by using bootstrapping. Results A total of 9751 breast MRI examinations from 5086 patients (mean age, 56 years ± 10 [SD]) were included. Readers who were blinded to the nature of the images could not distinguish real from synthetic contrast-enhanced images (average accuracy of differentiation: approach A, 52 of 100; approach B, 61 of 100). The test set included images with and without enhancing lesions (29 enhancing masses and 21 nonmass enhancement; 50 total). When readers who were not blinded compared the appearance of the real versus synthetic contrast-enhanced images side by side, approach A image ratings were significantly higher than those of approach B (mean rating, 4.6 ± 0.1 vs 3.0 ± 0.2; P < .001), with the noninferiority margin met by synthetic images from approach A (P < .001) but not B (P > .99). Conclusion Generative adversarial networks may be useful to enable breast MRI with reduced contrast agent dose. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bahl in this issue.


Subject(s)
Contrast Media , Magnetic Resonance Imaging , Humans , Middle Aged , Retrospective Studies , Magnetic Resonance Imaging/methods , Breast , Machine Learning
6.
Radiology ; 309(1): e230806, 2023 10.
Article in English | MEDLINE | ID: mdl-37787671

ABSTRACT

Background Clinicians consider both imaging and nonimaging data when diagnosing diseases; however, current machine learning approaches primarily consider data from a single modality. Purpose To develop a neural network architecture capable of integrating multimodal patient data and compare its performance to models incorporating a single modality for diagnosing up to 25 pathologic conditions. Materials and Methods In this retrospective study, imaging and nonimaging patient data were extracted from the Medical Information Mart for Intensive Care (MIMIC) database and an internal database comprised of chest radiographs and clinical parameters inpatients in the intensive care unit (ICU) (January 2008 to December 2020). The MIMIC and internal data sets were each split into training (n = 33 893, n = 28 809), validation (n = 740, n = 7203), and test (n = 1909, n = 9004) sets. A novel transformer-based neural network architecture was trained to diagnose up to 25 conditions using nonimaging data alone, imaging data alone, or multimodal data. Diagnostic performance was assessed using area under the receiver operating characteristic curve (AUC) analysis. Results The MIMIC and internal data sets included 36 542 patients (mean age, 63 years ± 17 [SD]; 20 567 male patients) and 45 016 patients (mean age, 66 years ± 16; 27 577 male patients), respectively. The multimodal model showed improved diagnostic performance for all pathologic conditions. For the MIMIC data set, the mean AUC was 0.77 (95% CI: 0.77, 0.78) when both chest radiographs and clinical parameters were used, compared with 0.70 (95% CI: 0.69, 0.71; P < .001) for only chest radiographs and 0.72 (95% CI: 0.72, 0.73; P < .001) for only clinical parameters. These findings were confirmed on the internal data set. Conclusion A model trained on imaging and nonimaging data outperformed models trained on only one type of data for diagnosing multiple diseases in patients in an ICU setting. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Kitamura and Topol in this issue.


Subject(s)
Deep Learning , Humans , Male , Middle Aged , Aged , Retrospective Studies , Radiography , Databases, Factual , Inpatients
7.
Radiology ; 307(1): e220510, 2023 04.
Article in English | MEDLINE | ID: mdl-36472534

ABSTRACT

Background Supine chest radiography for bedridden patients in intensive care units (ICUs) is one of the most frequently ordered imaging studies worldwide. Purpose To evaluate the diagnostic performance of a neural network-based model that is trained on structured semiquantitative radiologic reports of bedside chest radiographs. Materials and Methods For this retrospective single-center study, children and adults in the ICU of a university hospital who had been imaged using bedside chest radiography from January 2009 to December 2020 were reported by using a structured and itemized template. Ninety-eight radiologists rated the radiographs semiquantitatively for the severity of disease patterns. These data were used to train a neural network to identify cardiomegaly, pulmonary congestion, pleural effusion, pulmonary opacities, and atelectasis. A held-out internal test set (100 radiographs from 100 patients) that was assessed independently by an expert panel of six radiologists provided the ground truth. Individual assessments by each of these six radiologists, by two nonradiologist physicians in the ICU, and by the neural network were compared with the ground truth. Separately, the nonradiologist physicians assessed the images without and with preliminary readings provided by the neural network. The weighted Cohen κ coefficient was used to measure agreement between the readers and the ground truth. Results A total of 193 566 radiographs in 45 016 patients (mean age, 66 years ± 16 [SD]; 61% men) were included and divided into training (n = 122 294; 64%), validation (n = 31 243; 16%), and test (n = 40 029; 20%) sets. The neural network exhibited higher agreement with a majority vote of the expert panel (κ = 0.86) than each individual radiologist compared with the majority vote of the expert panel (κ = 0.81 to ≤0.84). When the neural network provided preliminary readings, the reports of the nonradiologist physicians improved considerably (aided vs unaided, κ = 0.87 vs 0.79, respectively; P < .001). Conclusion A neural network trained with structured semiquantitative bedside chest radiography reports allowed nonradiologist physicians improved interpretations compared with the consensus reading of expert radiologists. © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Wielpütz in this issue.


Subject(s)
Artificial Intelligence , Radiography, Thoracic , Male , Adult , Child , Humans , Aged , Female , Retrospective Studies , Radiography, Thoracic/methods , Lung , Radiography
8.
Arch Orthop Trauma Surg ; 143(8): 4983-4991, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36821049

ABSTRACT

BACKGROUND: Proximal humeral shaft fractures are surgically challenging and plate osteosynthesis with a long straight plate is one operative treatment option in these patients although endangering the radial nerve distally. Helical plates potentially avoid the radial nerve by twisting around the humeral shaft. Aim of the study was to investigate in a human cadaveric model the biomechanical competence of helical plates versus straight lateral plates used for fixation of proximal third comminuted humeral shaft fractures. METHODS: Eight pairs of humeral cadaveric humeri were instrumented using either a long 90°-helical plate (Group1) or a straight long PHILOS plate (Group2). An unstable proximal humeral shaft fracture was simulated by means of a 5 cm osteotomy gap. All specimens were tested under quasi-static loading in axial compression, internal and external rotation, and bending in four directions. Subsequently, progressively increasing cyclic loading in internal rotation until failure was applied and interfragmentary movements were monitored by motion tracking. RESULTS: During static testing flexion/extension deformation in Group1 was significantly higher, however, varus/valgus deformation as well as shear and torsional displacement under torsional load remained statistically indifferent between both groups. During cyclic testing shear and torsional displacements were both significantly higher in Group1 compared to Group 2. However, cycles to catastrophic failure remained statistically indifferent between the groups. CONCLUSIONS: From a biomechanical perspective, although 90°-helical plating is associated with higher initial stability against varus/valgus collapse and comparable endurance under dynamic loading, it demonstrates lower resistance to flexion/extension and internal rotation with bigger shear interfragmentary displacements versus straight lateral plating and, therefore, cannot be considered as its real alternative. Alternative helical plate designs should be investigated in the future.


Subject(s)
Humeral Fractures , Shoulder Fractures , Humans , Biomechanical Phenomena , Fracture Fixation, Internal , Bone Plates , Humeral Fractures/surgery , Humerus , Shoulder Fractures/surgery , Cadaver
9.
Int J Mol Sci ; 23(13)2022 Jun 22.
Article in English | MEDLINE | ID: mdl-35805925

ABSTRACT

Based on in silico, in situ, and in vivo studies, this study aims to develop a new method for the quantitative chemical exchange saturation transfer (qCEST) technique considering multi-pool systems. To this end, we extended the state-of-the-art apparent exchange-dependent relaxation (AREX) method with a Lorentzian correction (LAREX). We then validated this new method with in situ and in vivo experiments on human intervertebral discs (IVDs) using the Kendall-Tau correlation coefficient. In the in silico experiments, we observed significant deviations of the AREX method as a function of the underlying exchange rate (kba) and fractional concentration (fb) compared to the ground truth due to the influence of other exchange pools. In comparison to AREX, the LAREX-based Ω-plot approach yielded a substantial improvement. In the subsequent in situ and in vivo experiments on human IVDs, no correlation to the histological reference standard or Pfirrmann classification could be found for the fb (in situ: τ = −0.17 p = 0.51; in vivo: τ = 0.13 p = 0.30) and kba (in situ: τ = 0.042 p = 0.87; in vivo: τ = −0.26 p = 0.04) of Glycosaminoglycan (GAG) with AREX. In contrast, the influence of interfering pools could be corrected by LAREX, and a moderate to strong correlation was observed for the fractional concentration of GAG for both in situ (τ = −0.71 p = 0.005) and in vivo (τ = −0.49 p < 0.001) experiments. The study presented here is the first to introduce a new qCEST method that enables qCEST imaging in systems with multiple proton pools.


Subject(s)
Intervertebral Disc , Magnetic Resonance Imaging , Glycosaminoglycans , Humans , Magnetic Resonance Imaging/methods , Protons
10.
MAGMA ; 34(2): 241-248, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32500389

ABSTRACT

OBJECTIVE: To measure sodium relaxation times and concentrations in human wrists on a clinical magnetic resonance imaging (MRI) scanner with a density-adapted radial sequence. MATERIALS AND METHODS: Sodium MRI of human wrists was conducted on a 3T MR system using a dual-tuned 1H/23Na surface coil. We performed two studies with 10 volunteers each investigating either sodium T1 (study 1) or sodium T2* (study 2) relaxation times in the radiocarpal joint (RCJ) and midcarpal joint (MCJ). Sodium concentrations of both regions were determined. RESULTS: No differences for transversal of longitudinal relaxation times were found between RCJ and MCJ (T2,s*(RCJ) = (0.9 ± 0.4) ms; T2,s*(MCJ) = (0.9 ± 0.3) ms; T2,l*(RCJ) = (14.9 ± 0.9) ms; T2,l*(MCJ) = (13.9 ± 1.1) ms; T1(RCJ) = (19.0 ± 2.4) ms; T1(MCJ) = (18.5 ± 2.1) ms). Sodium concentrations were (157.7 ± 28.4) mmol/l for study 1 and (159.8 ± 29.1) mmol/l for study 2 in the RCJ, and (172.7 ± 35.6) mmol/l for study 1 and (163.4 ± 26.3) mmol/l for study 2 in the MCJ. CONCLUSION: We successfully determined sodium relaxation times and concentrations of the human wrist on a 3T MRI scanner.


Subject(s)
Cartilage, Articular , Wrist , Feasibility Studies , Humans , Magnetic Resonance Imaging , Sodium
11.
MAGMA ; 34(2): 249-260, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32725359

ABSTRACT

OBJECTIVE: To establish and optimize a stable 3 Tesla (T) glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging protocol for assessing the articular cartilage of the tibiotalar joint in healthy volunteers and patients after a sustained injury to the ankle. METHODS: Using Bloch-McConnell simulations, we optimized the sequence protocol for a 3 T MRI scanner for maximum gagCEST effect size within a clinically feasible time frame of less than 07:30 min. This protocol was then used to analyze the gagCEST effect of the articular cartilage of the tibiotalar joint of 17 healthy volunteers and five patients with osteochondral lesions of the talus following ankle trauma. Reproducibility was tested with the intraclass correlation coefficient. RESULTS: The mean magnetization transfer ratio asymmetry (MTRasym), i.e., the gagCEST effect size, was significantly lower in patients than in healthy volunteers (0.34 ± 1.9% vs. 1.49 ± 0.11%; p < 0.001 [linear mixed model]). Intra- and inter-rater reproducibility was excellent with an average measure intraclass correlation coefficient (ICC) of 0.97 and a single measure ICC of 0.91 (p < 0.01). DISCUSSION: In this feasibility study, pre-morphological tibiotalar joint cartilage damage was quantitatively assessable on the basis of the optimized 3 T gagCEST imaging protocol that allowed stable quantification gagCEST effect sizes across a wide range of health and disease in clinically feasible acquisition times.


Subject(s)
Cartilage, Articular , Feasibility Studies , Glycosaminoglycans , Humans , Magnetic Resonance Imaging , Reproducibility of Results
12.
Skeletal Radiol ; 50(3): 531-541, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32845377

ABSTRACT

BACKGROUND: Because of overlapping phenotypical presentations, the diagnostic differentiation of rheumatoid arthritis (RA) and psoriatic arthritis (PsA) remains challenging. Thus, this study aimed to examine the diagnostic value of distinct imaging features obtained by high-resolution 3-T MRI for the diagnostic differentiation. MATERIALS AND METHODS: Seventeen patients with PsA and 28 patients with RA were imaged at high resolution using 3-T MRI scanners and a dedicated 16-channel hand coil. All images were analyzed according to the outcome measures in rheumatology clinical trials' (OMERACT) RAMRIS (Rheumatoid Arthritis Magnetic Resonance Imaging Score) and PsAMRIS (Psoriatic Arthritis Magnetic Resonance Imaging Score) for the presence and intensity of synovitis, flexor tenosynovitis, bone edema, bone erosion, periarticular inflammation, bone proliferation, and joint space narrowing. Next, odds ratios (OR) were calculated to determine the strength of the associations between these imaging features, demographic characteristics, and the outcome RA vs. PsA. RESULTS: PsA could be differentiated from RA by extracapsular inflammatory changes (PsAMRIS sub-score "periarticular inflammation"), with low odds for the presence of RA (OR of 0.06, p < 0.01) at all metacarpophalangeal (MCP) joints. A prediction model informed by the items that were strongest associated with the presence of RA or PsA demonstrated excellent differentiating capability with an area under the curve of 98.1%. CONCLUSION: High-resolution imaging is beneficial for the identification of relevant imaging features that may assist the clinical differentiation of inflammatory conditions of the hand. At the MCP level, extracapsular inflammatory changes were strongly associated with PsA and may consequently allow the imaging differentiation of PsA and RA.


Subject(s)
Arthritis, Psoriatic , Arthritis, Rheumatoid , Synovitis , Arthritis, Psoriatic/diagnostic imaging , Arthritis, Rheumatoid/diagnostic imaging , Humans , Magnetic Resonance Imaging , Metacarpophalangeal Joint
13.
Int Orthop ; 45(9): 2355-2363, 2021 09.
Article in English | MEDLINE | ID: mdl-34357432

ABSTRACT

PURPOSE: To assess which pre-operative parameters correlate with wound revisions after an extended lateral approach to the calcaneus. METHODS: Pre-operative laser-Doppler spectrophotometry was applied in patients undergoing open reduction and internal fixation. The number of wound revisions was recorded during pos-toperative follow-up. Spearman rho analysis was used to identify factors associated with wound revision and receiver operator characteristics curves were calculated for the identified factors. RESULTS: Thirty-four patients (29 men, 5 women; 37 calcanei) with a mean patient age of 43 ± 14 years were analyzed. The minimal oxygen saturation value at the five measurement locations as well as the minimal value for flow correlated negatively with wound revisions (p value = 0.025 and 0.038, respectively). The area under the curve for the pre-operative minimal value of oxygen saturation was 0.841 (95%CI 0.64-1.00, p = 0.028), indicating a good accuracy as a test to predict wound revision. CONCLUSION: A pre-operative oxygen saturation of at least 20.5% across five measurement points along the anticipated incision identified all patients not needing a wound revision (negative predictive value 100%). On the other hand, patients with at least one measurement below 20.5% were at risk for wound revision surgery (sensitivity 100%, specificity 48.5%). ClinicalTrials.gov NCT01264146.


Subject(s)
Calcaneus , Fractures, Bone , Adult , Calcaneus/diagnostic imaging , Calcaneus/surgery , Female , Fracture Fixation, Internal/adverse effects , Fractures, Bone/surgery , Humans , Lasers , Male , Middle Aged , Oxygen , Reoperation , Retrospective Studies , Spectrophotometry
14.
Medicina (Kaunas) ; 57(9)2021 Aug 27.
Article in English | MEDLINE | ID: mdl-34577807

ABSTRACT

Background and Objectives: Wound infections provoked by alterations in microcirculation are major complications in the treatment of trochanteric femur fractures. Surgical fracture fixation on a traction table is the gold standard for treatment, but the effect on tissue microcirculation is unknown. Microcirculation could be impaired by the pull on the soft-tissue or by a release of vasoactive factors. We hypothesized that intraoperative traction impairs soft-tissue microcirculation. Materials and Methods: In 22 patients (14 women, eight men), average age 78 years (range 36-96 ± 14), with trochanteric femur fractures, non-invasive laser-Doppler spectrophotometry was used to assess oxygen saturation, hemoglobin content, and blood flow in the skin and subcutaneous tissue before and after application of traction. Measurements were recorded in nine locations around the greater trochanter at a depth of 2, 8, and 15 mm before and after fracture reduction by traction. Results: No differences were found in any depth with traction compared to without (oxygen saturation: p = 0.751, p = 0.308, and p = 0.955, haemoglobin content: p = 0.651, p = 0.928, and p = 0.926, blood flow: p = 0.829, p = 0.866, and p = 0.411). Conclusion: In this pilot study, the application of traction does not affect skin and subcutaneous microcirculation in the surgery of proximal femur fractures.


Subject(s)
Femoral Fractures , Traction , Adult , Female , Femoral Fractures/surgery , Femur/diagnostic imaging , Femur/surgery , Humans , Male , Microcirculation , Middle Aged , Pilot Projects , Young Adult
15.
MAGMA ; 33(6): 839-854, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32314105

ABSTRACT

OBJECTIVE: Beyond static assessment, functional techniques are increasingly applied in magnetic resonance imaging (MRI) studies. Stress MRI techniques bring together MRI and mechanical loading to study knee joint and tissue functionality, yet prototypical axial compressive loading devices are bulky and complex to operate. This study aimed to design and validate an MRI-compatible pressure-controlled varus-valgus loading device that applies loading along the joint line. METHODS: Following the device's thorough validation, we demonstrated proof of concept by subjecting a structurally intact human cadaveric knee joint to serial imaging in unloaded and loaded configurations, i.e. to varus and valgus loading at 7.5 kPa (= 73.5 N), 15 kPa (= 147.1 N), and 22.5 kPa (= 220.6 N). Following clinical standard (PDw fs) and high-resolution 3D water-selective cartilage (WATSc) sequences, we performed manual segmentations and computations of morphometric cartilage measures. We used CT and radiography (to quantify joint space widths) and histology and biomechanics (to assess tissue quality) as references. RESULTS: We found (sub)regional decreases in cartilage volume, thickness, and mean joint space widths reflective of areal pressurization of the medial and lateral femorotibial compartments. DISCUSSION: Once substantiated by larger sample sizes, varus-valgus loading may provide a powerful alternative stress MRI technique.


Subject(s)
Cartilage, Articular , Biomechanical Phenomena , Cartilage, Articular/diagnostic imaging , Humans , Knee Joint/diagnostic imaging , Magnetic Resonance Imaging , Weight-Bearing
16.
Eur Radiol ; 29(12): 6671-6681, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31187218

ABSTRACT

OBJECTIVE: To evaluate whether the response to loading of cartilage samples as assessed ex vivo by quantitative MRI (qMRI) mapping techniques can differentiate intact and early degenerative cartilage. METHODS: Upon IRB approval and written informed consent, 59 macroscopically intact osteochondral samples were obtained from the central lateral femoral condyles of patients undergoing total knee replacement. Spatially resolved T1, T2, T2*, and T1ρ maps were generated prior to and during displacement-controlled quasi-static indentation loading to 405 µm (Δ1/2) and 810 µm (Δ1). Upon manual segmentation, absolute qMRI parameters and loading-induced relative changes (δ1/2, δ1) were determined for the entire cartilage sample and distinct zones and regions. Based on their histologically determined degeneration as quantified according to Mankin (Mankin sum scores [MSS], range 0-14), samples were dichotomised into intact (int; MSS 0-4, n = 35) and early degenerative (ed, MSS 5-8, n = 24). RESULTS: For T1ρ, consistent loading-induced increases were found for δ1/2 and δ1. Throughout the entire sample, increases in T1ρ were significantly higher in early degenerative than in intact samples (Δ1/2(ed) = 23.8 [q25 = 18.1, q75 = 29.0] %; Δ1/2(int) = 12.7 [q25 = 5.9, q75 = 19.5] %; p < 0.0005), according to Wilcoxon's signed-rank test). Zonal and regional analysis revealed these changes to be most pronounced in the sub-pistonal area. No significant degeneration-dependent loading-induced changes were found for T1, T2, or T2*. CONCLUSION: Aberrant load-bearing of early degenerative cartilage may be detected using T1ρ mapping as a function of loading. Hence, the diagnostic differentiation of intact versus early degenerative cartilage may allow the reliable identification of early and potentially reversible cartilage degeneration, thereby opening new opportunities for diagnosis and treatment of cartilage pathologies. KEY POINTS: • T1ρ mapping of the cartilage response to loading allows the reliable identification of early degenerative changes ex vivo. • Distinct response-to-loading patterns of cartilage tissue as assessed by functional MRI techniques are associated with biomechanical and histological tissue properties. • Non-invasive functional MR imaging techniques may facilitate the more sensitive monitoring of therapeutic outcomes and treatment strategies.


Subject(s)
Cartilage Diseases/diagnosis , Cartilage, Articular/pathology , Knee Joint/pathology , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
17.
JAMA ; 331(15): 1320-1321, 2024 04 16.
Article in English | MEDLINE | ID: mdl-38497956

ABSTRACT

This study compares 2 large language models and their performance vs that of competing open-source models.


Subject(s)
Artificial Intelligence , Diagnostic Imaging , Medical History Taking , Language
18.
Int J Mol Sci ; 20(7)2019 Apr 06.
Article in English | MEDLINE | ID: mdl-30959909

ABSTRACT

Culturing articular chondrocytes under physiological oxygen tension exerts positive effects on their extracellular matrix synthesis. The underlying molecular mechanisms which enhance the chondrocytic phenotype are, however, still insufficiently elucidated. The TGF-ß superfamily of growth factors, and the prototypic TGF-ß isoforms in particular, are crucial in maintaining matrix homeostasis of these cells. We employed a feedback-controlled table-top bioreactor to investigate the role of TGF-ß in microtissues of human chondrocytes over a wider range of physiological oxygen tensions (i.e., physoxia). We compared 1%, 2.5%, and 5% of partial oxygen pressure (pO2) to the 'normoxic' 20%. We confirmed physoxic conditions through the induction of marker genes (PHD3, VEGF) and oxygen tension-dependent chondrocytic markers (SOX9, COL2A1). We identified 2.5% pO2 as an oxygen tension optimally improving chondrocytic marker expression (ACAN, COL2A1), while suppressing de-differentiation markers (COL1A1, COL3A1). Expression of TGF-ß isoform 2 (TGFB2) was, relatively, most responsive to 2.5% pO2, while all three isoforms were induced by physoxia. We found TGF-ß receptors ALK1 and ALK5 to be regulated by oxygen tension on the mRNA and protein level. In addition, expression of type III co-receptors betaglycan and endoglin appeared to be regulated by oxygen tension as well. R-Smad signaling confirmed that physoxia divergently regulated phosphorylation of Smad1/5/8 and Smad2/3. Pharmacological inhibition of canonical ALK5-mediated signaling abrogated physoxia-induced COL2A1 and PAI-1 expression. Physoxia altered expression of hypertrophy markers and that of matrix metalloproteases and their activity, as well as expression ratios of specific proteins (Sp)/Krüppel-like transcription factor family members SP1 and SP3, proving a molecular concept of ECM marker regulation. Keeping oxygen levels tightly balanced within a physiological range is important for optimal chondrocytic marker expression. Our study provides novel insights into transcriptional regulations in chondrocytes under physoxic in vitro conditions and may contribute to improving future cell-based articular cartilage repair strategies.


Subject(s)
Bioreactors/microbiology , Chondrocytes/metabolism , Extracellular Matrix/metabolism , Signal Transduction/physiology , Aggrecans/metabolism , Collagen Type II/metabolism , Collagen Type III/metabolism , Humans , Hypoxia-Inducible Factor-Proline Dioxygenases/metabolism , Protein Isoforms/metabolism , SOX9 Transcription Factor/metabolism , Signal Transduction/genetics , Smad1 Protein/metabolism , Smad2 Protein/metabolism , Smad3 Protein/metabolism , Smad5 Protein/metabolism , Smad8 Protein/metabolism , Transforming Growth Factor beta/metabolism , Transforming Growth Factor beta2/metabolism , Vascular Endothelial Growth Factor A/metabolism
19.
Int Orthop ; 42(2): 409-418, 2018 02.
Article in English | MEDLINE | ID: mdl-28780597

ABSTRACT

OBJECTIVES: To reduce mechanical complications after osteosynthesis of femoral neck fractures, improved fixation techniques have been developed including blade or screw-anchor devices. This biomechanical study compares different fixation systems used for treatment of unstable femoral neck fractures with evaluation of failure mode, load to failure, stiffness, femoral head rotation, femoral neck shortening and femoral head migration. METHODS: Standardized Pauwels type 3 fractures (AO/OTA 31-B2) with comminution were created in 18 biomechanical sawbones using a custom-made sawguide. Fractures were stabilized using either SHS-Screw, SHS-Blade or Rotationally Stable Screw-Anchor (RoSA). Femurs were positioned in 25 degrees adduction and ten degrees posterior flexion and were cyclically loaded with an axial sinusoidal loading pattern of 0.5 Hz, starting with 300 N, with an increase by 300 N every 2000 cycles until bone-implant failure occurred. RESULTS: Mean failure load for the Screw-Anchor fixation (RoSA) was 5100 N (IQR 750 N), 3900 N (IQR 75 N) for SHS-Blade and 3000 N (IQR 675 N; p = 0.002) for SHS-Screw. For SHS-Screw and SHS-Blade we observed fracture displacement with consecutive fracture collapse as the main reason for failure, whereas RoSA mainly showed a cut-out under high loadings. Mean stiffness at 1800 N was 826 (IQR 431) N/mm for SHS-Screw, 1328 (IQR 441) N/mm for SHS-Blade and 1953 (IQR 617) N/mm for RoSA (p = 0.003). With a load of 1800 N (SHS-Screw 12° vs. SHS-Blade 7° vs. RoSA 2°; p = 0.003) and with 2700 N (24° vs. 15° vs. 3°; p = 0.002) the RoSA implants demonstrated a higher rotational stability and had the lowest femoral neck shortening (p = 0.002), compared with the SHS groups. At the 2700 N load point, RoSA systems showed a lower axial (p = 0.019) and cranial (p = 0.031) femoral head migration compared to the SHS-Screw. CONCLUSIONS: In our study, the new Screw-Anchor fixation (RoSA) was superior to the comparable SHS implants regarding rotational stability and femoral neck shortening. Failure load, stiffness, femoral head migration, and resistance to fracture displacement were in RoSA implants higher than in SHS-Screws, but without significance in comparison to SHS-Blades.


Subject(s)
Bone Screws/adverse effects , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/instrumentation , Biomechanical Phenomena , Equipment Failure Analysis , Femur Neck/surgery , Fracture Dislocation/surgery , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Humans , Prosthesis Failure/adverse effects
20.
Int Orthop ; 42(11): 2705-2713, 2018 11.
Article in English | MEDLINE | ID: mdl-29931550

ABSTRACT

PURPOSE: Open reduction and internal fixation (ORIF) using an extended lateral approach combined with plate osteosynthesis represents the current gold standard in calcaneal fracture treatment, but it is associated with a wound complication rate of up to 30%. Literature suggests that micro-circulation is one of the key factors for sufficient wound healing. The aim of this study was to evaluate soft tissue micro-circulation of the hindfoot in healthy volunteers to determine influencing factors and to identify hypoxic or hypoperfused areas in non-trauma situations, with special attention to surgical approaches. METHODS: Micro-circulation of the lateral hindfoot of 125 participants was non-invasively measured at 2 and 8 mm depths, utilizing a Micro-Lightguide O2C® spectrophotometer. Blood flow (BF [AU]) and oxygen saturation (SO2 [%]) of ten measurement points (MPs) were documented. Demographic factors (age, gender, body mass index [BMI], systolic/diastolic blood pressure, smoking, and pack-years) and regional differences with special regard to surgical approaches (extended lateral approach, Palmer approach, Ollier approach, and a self-modified extended lateral approach) were analyzed. RESULTS: The SO2 assessments at 2- and 8-mm depths revealed higher values in males (p = 0.043; p = 0.025). There was a correlation between higher age and lower 2 mm BF (p = 0.044). Smoking history and number of pack-years did not predict micro-circulation. BF at the 2 mm depth was highest in the regions of Palmer and Ollier approach (p < 0.001). The MP at the distal calcaneal tuberosity showed significantly higher values regarding all parameters (SO2 (2 mm), p < 0.001; SO2 (8 mm), p = 0.001; BF (2 mm), p < 0.001; BF (8 mm), p < 0.001), compared to the surrounding area. CONCLUSIONS: In non-trauma situations, young males were associated with better micro-circulatory supply of the lateral hindfoot. There was a trend for higher blood flow in regions of the Palmer and Ollier approach. The distal calcaneal tuberosity was clearly superior in all micro-circulatory parameters when compared to the surrounding area.


Subject(s)
Calcaneus/injuries , Foot/blood supply , Fractures, Bone/surgery , Microcirculation/physiology , Adult , Aged , Bone Plates , Calcaneus/surgery , Cross-Sectional Studies , Female , Foot/surgery , Fracture Fixation, Internal , Healthy Volunteers , Humans , Male , Middle Aged , Oxygen/blood , Pilot Projects , Treatment Outcome , Wound Healing/physiology , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL