Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 84
Filter
Add more filters

Country/Region as subject
Publication year range
1.
Surg Endosc ; 36(5): 3169-3177, 2022 05.
Article in English | MEDLINE | ID: mdl-34231070

ABSTRACT

BACKGROUND: Colonoscopy is a technically challenging procedure. The colonoscope is prone to forming loops in the colon, which can lead patient discomfort and even perforation. We hypothesized that expert endoscopists use techniques to avoid loop formation, identify and straighten loops earlier, and thus exert less force. METHODS: Using a commercially available physical colon simulator model (Kyoto Kagaku), electromagnetic tracking markers (NDI Medical) were placed along the mobile segments of the colon (sigmoid, transverse) to measure the degree of displacement of the colon as the scope was advanced to the cecum. The colon model was set for each participant to simulate a redundant alpha loop in the sigmoid colon. Gastroenterology and surgical trainees and attendings were assessed. Demographic data were collected for each participant. RESULTS: Seventy-five participants were enrolled in the study. There were 17 (22.7%) attending physicians, and 58 (77.3%) trainees. Attending physicians advanced the scope to the cecum faster. The mean time required for procedure completion was 360.5 s compared to 178.4 s for the trainee and attending groups respectively (mean difference: 182.1 s, 95% CI: 93.0, 269.7; p = 0.0002). Attending physicians exerted significantly lower mean colonic displacement than trainees. The mean colonic displacement was 79.8 mm for the trainee group and 57.9 mm for the attending group (mean difference: 21.9 mm, 95% CI: 2.6, 41.2; p = 0.04). Those who used torque steering caused lower maximum colonic displacement than those who used knob steering. CONCLUSION: Attending physicians advance the scope during colonoscopy in a manner that results in significantly less colonic displacement than resident trainees. Although prior studies have shown a difference in force application between endoscopists and inexperienced students, ours is the first to differentiate across varying degrees of endoscopic skill. Future studies will define metrics for incorporation into endoscopic training curricula, focusing on techniques that encourage safety and comfort for patients.


Subject(s)
Clinical Competence , Colonoscopes , Colon , Colonoscopy/methods , Endoscopy, Gastrointestinal , Humans
2.
AAPS PharmSciTech ; 20(5): 206, 2019 May 30.
Article in English | MEDLINE | ID: mdl-31147791

ABSTRACT

The multi-stage cascade impactor (CI) is the mainstay method for the determination of the aerodynamic particle size distribution (APSD) of aerosols emitted from orally inhaled products (OIPs). CIs are designed to operate at a constant flow rate throughout the measurement process. However, it is necessary to mimic an inhalation maneuver to disperse the powder into an aerosol when testing passive dry powder inhalers (DPIs), which constitute a significant portion of available products in this inhaler class. Methods in the pharmacopeial compendia intended for product quality assurance initiate sampling by applying a vacuum to the measurement apparatus using a timer-operated solenoid valve located downstream of the CI, resulting in a period when the flow rate through the impactor rapidly increases from zero towards the target flow rate. This article provides recommendations for achieving consistent APSD measurements, including selection of the CI, pre-separator, and flow control equipment, as well as reviewing considerations that relate to the shape of the flow rate-sampling time profile. Evidence from comparisons of different DPIs delivering the same active pharmaceutical ingredients (APIs) is indicative that the compendial method for APSD measurement is insensitive as a predictor of pharmacokinetic outcomes. Although inappropriate for product quality testing, guidance is therefore provided towards adopting a more clinically realistic methodology, including the use of an anatomically appropriate inlet and mimicking patient inhalation at the DPI while operating the CI at constant flow rate. Many of these recommendations are applicable to the testing of other OIP classes.


Subject(s)
Aerosols/standards , Dry Powder Inhalers/methods , Equipment Design/methods , Particle Size , Quality Control , Administration, Inhalation , Aerosols/administration & dosage , Aerosols/chemistry , Dry Powder Inhalers/instrumentation , Equipment Design/instrumentation , Humans , Powders , Respiratory System Agents/administration & dosage , Respiratory System Agents/chemistry , Respiratory System Agents/standards , Technology, Pharmaceutical/methods
3.
Sensors (Basel) ; 17(8)2017 Aug 05.
Article in English | MEDLINE | ID: mdl-28783069

ABSTRACT

Minimally invasive skills assessment methods are essential in developing efficient surgical simulators and implementing consistent skills evaluation. Although numerous methods have been investigated in the literature, there is still a need to further improve the accuracy of surgical skills assessment. Energy expenditure can be an indication of motor skills proficiency. The goals of this study are to develop objective metrics based on energy expenditure, normalize these metrics, and investigate classifying trainees using these metrics. To this end, different forms of energy consisting of mechanical energy and work were considered and their values were divided by the related value of an ideal performance to develop normalized metrics. These metrics were used as inputs for various machine learning algorithms including support vector machines (SVM) and neural networks (NNs) for classification. The accuracy of the combination of the normalized energy-based metrics with these classifiers was evaluated through a leave-one-subject-out cross-validation. The proposed method was validated using 26 subjects at two experience levels (novices and experts) in three arthroscopic tasks. The results showed that there are statistically significant differences between novices and experts for almost all of the normalized energy-based metrics. The accuracy of classification using SVM and NN methods was between 70% and 95% for the various tasks. The results show that the normalized energy-based metrics and their combination with SVM and NN classifiers are capable of providing accurate classification of trainees. The assessment method proposed in this study can enhance surgical training by providing appropriate feedback to trainees about their level of expertise and can be used in the evaluation of proficiency.


Subject(s)
Motor Skills , Clinical Competence , Feedback
4.
AAPS PharmSciTech ; 18(8): 3296-3306, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28589305

ABSTRACT

This article reports on results from a two-lab, multiple impactor experiment evaluating the abbreviated impactor measurement (AIM) concept, conducted by the Cascade Impaction Working Group of the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS). The goal of this experiment was to expand understanding of the performance of an AIM-type apparatus based on the Andersen eight-stage non-viable cascade impactor (ACI) for the assessment of inhalation aerosols and sprays, compared with the full-resolution version of that impactor described in the pharmacopeial compendia. The experiment was conducted at two centers with a representative commercially available pressurized metered dose inhaler (pMDI) containing albuterol (salbutamol) as active pharmaceutical ingredient (API). Metrics of interest were total mass (TM) emitted from the inhaler, impactor-sized mass (ISM), as well as the ratio of large particle mass (LPM) to small particle mass (SPM). ISM and the LPM/SPM ratio together comprise the efficient data analysis (EDA) metrics. The results of the comparison demonstrated that in this study, the AIM approach had adequate discrimination to detect changes in the mass median aerodynamic diameter (MMAD) of the ACI-sampled aerodynamic particle size distribution (APSD), and therefore could be employed for routine product quality control (QC). As with any test method considered for inclusion in a regulatory filing, the transition from an ACI (used in development) to an appropriate AIM/EDA methodology (used in QC) should be evaluated and supported by data on a product-by-product basis.


Subject(s)
Albuterol/analysis , Metered Dose Inhalers/standards , Particle Size , Technology, Pharmaceutical/methods , Technology, Pharmaceutical/standards , Administration, Inhalation , Aerosols , Albuterol/chemistry , Bronchodilator Agents/analysis , Bronchodilator Agents/chemistry , Equipment Design/methods , Equipment Design/standards , Metered Dose Inhalers/trends , Nebulizers and Vaporizers/standards , Nebulizers and Vaporizers/trends , Quality Control
5.
J Neuroeng Rehabil ; 13: 15, 2016 Feb 18.
Article in English | MEDLINE | ID: mdl-26891751

ABSTRACT

BACKGROUND: The assessment and treatment of writer's cramp is complicated due to the variations in the forces and angles of involved joints. Additionally, in some cases compensatory movements for cramp relief further complicates assessment. Currently these variables are subjectively measured with clinical scales and visual assessments. This subjectivity makes it difficult to successfully administer interventions such as Botulinum toxin injection or orthotics resulting in poor efficacy and significant side effects. METHOD: A multi-sensor system was used to record finger and wrist forces along with deviation angles at the wrist, elbow and shoulder while 9 patients with writer's cramp performed a series of standardized tasks on surfaces inclined at different angles. Clinical, kinetic, and kinematic information regarding cramping was collected. RESULTS: First, four tasks appeared to best predict cramp occurrence. Second, unique biomechanical profiles emerged for patients regarding force, angles and cramp severity. Third, cluster analyses using these features showed a clear separation of patients into two severity classes. Finally, a relationship between severity and kinetic-kinematic information suggested that primary cramping versus compensatory movements could be potentially inferred. CONCLUSIONS: The results demonstrate that using a set of standardized tasks and objective measures, individual profiles for arm movements and applied forces associated with writer's cramp can be generated. The clinician can then accurately target the biomechanics specifically, whether it is with injection or other rehabilitative measures, fulfilling an important unmet need in the treatment of writer's cramp.


Subject(s)
Biomechanical Phenomena , Dystonic Disorders/physiopathology , Upper Extremity/physiopathology , Aged , Algorithms , Dystonia/physiopathology , Elbow/physiopathology , Female , Hand/physiopathology , Hand Strength , Humans , Male , Middle Aged , Movement , Predictive Value of Tests , Shoulder/physiopathology , Wrist/physiopathology
6.
Surg Endosc ; 29(12): 3655-65, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25740641

ABSTRACT

INTRODUCTION: Training surgeons in minimally invasive surgery (MIS) requires surgical residents to operate under the direction of a consultant. The inability of the instructing surgeon to point at the laparoscopic monitor without releasing the instruments remains a barrier to effective instruction. The wireless hands-free surgical pointer (WHaSP) has been developed to aid instruction during MIS. METHODS: The objective of this study was to evaluate the effectiveness and likeability of the WHaSP as an instructional tool compared with the conventional methods. Data were successfully collected during 103 laparoscopic cholecystectomy procedures, which had been randomized to use or not use the WHaSP as a teaching tool. Audio and video from the surgeries were recorded and analyzed. Instructing surgeons, operating surgeons, and camera assistants provided feedback through a post-operative questionnaire that used a five-level Likert scale. The questionnaire results were analyzed using a Mann-Whitney U test. RESULTS: There were no negative effects on surgery completion time or instruction practice due to the use of the WHaSP. The number of times an instructor surgeon pointed to the laparoscopic screen with their hand was significantly reduced when the WHaSP was utilized (p < 0.001). The questionnaires showed that WHaSP users found it to be comfortable, easy to use, and easy to control. Compared to when the WHaSP was not used, users found that communication was more effective (p = 0.002), locations were easier to communicate (p < 0.001), and instructions were easier to follow (p = 0.005). CONCLUSIONS: The WHaSP system was successfully used in surgery. It integrated seamlessly into existing equipment within the operating room and did not affect flow. The positive outcomes of utilizing the WHaSP were improved communication in the OR, improved efficiency and safety of the surgery, easy to use, and comfortable to wear. The surgeons showed a preference for utilizing the WHaSP if given a choice.


Subject(s)
Cholecystectomy, Laparoscopic/methods , Clinical Competence , Gallbladder Diseases/surgery , Practice Guidelines as Topic , Surgeons/standards , Female , Humans , Intraoperative Period
7.
Surg Endosc ; 28(7): 2106-19, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24519030

ABSTRACT

BACKGROUND: The loss of haptic information that results from the reduced-access conditions present in minimally invasive surgery (MIS) may compromise the safety of the procedures. This limitation must be overcome through training. However, current methods for determining the skill level of trainees do not measure critical elements of skill attainment. This study aimed to evaluate the usefulness of force information for the assessment of skill during MIS. METHODS: To achieve the study goal, experiments were performed using a set of sensorized instruments capable of measuring instrument position and tissue interaction forces. Several force-based metrics were developed as well as metrics that combine force and position information. RESULTS: The results show that experience level has a strong correlation with the new force-based metrics presented in this article. In particular, the integral and the derivative of the forces or the metrics that combine force and position provide the strongest correlations. CONCLUSIONS: This study showed that force-based metrics are better indications of performance than metrics based on task completion time or position information alone. The proposed metrics can be automatically computed, are completely objective, and measure important aspects of performance.


Subject(s)
Clinical Competence , Feedback , Laparoscopy/education , Software , Female , Humans , Male , Mechanical Phenomena , Models, Biological , Motor Skills , Time Factors
8.
Article in English | MEDLINE | ID: mdl-38236671

ABSTRACT

Parkinson's Disease (PD) has been found to cause force control deficits in upper and lower limbs. About 50% of patients with advanced PD develop a debilitating symptom called freezing of gait (FOG), which has been linked to force control problems in the lower limbs, and some may only have a limited response to the gold standard pharmaceutical therapy, levodopa, resulting in partially levodopa-responsive FOG (PLR-FOG). There has been limited research on investigating upper-limb force control in people with PD with PLR-FOG, and without FOG. In this pilot study, force control was explored using an upper-and-lower-limb haptics-enabled robot in a reaching task while people with PD with and without PLR-FOG were on their levodopa medication. A healthy control group was used for reference, and each cohort completed the task at three different levels of assistance provided by the robot. Similar significant proportional force control deficits were found in the upper and lower limbs in patients with PLR-FOG versus those without FOG. Some aspects of force control were found to be retained, including an ability to increase or decrease force in response to changes in resistance while completing a reaching task. Overall, these results suggest there are force control deficits in both the upper and lower limbs in people with PLR-FOG.


Subject(s)
Gait Disorders, Neurologic , Parkinson Disease , Humans , Parkinson Disease/diagnosis , Levodopa/therapeutic use , Gait Disorders, Neurologic/etiology , Gait Disorders, Neurologic/diagnosis , Pilot Projects , Gait/physiology
9.
Bioinformation ; 20(4): 378-385, 2024.
Article in English | MEDLINE | ID: mdl-38854770

ABSTRACT

The association between serum interleukin-6 (IL-6) and highly sensitive C - reactive protein (hsCRP) as predictors of the risk factors for Myocardial Infarction. The study included a total of 50 patients with Myocardial Infarction, aged between 25 to 74 years. The levels of hsCRP were measured using the immunoturbidimetry method, while Interleukin 6 was estimated using the sandwich ELISA method. Statistical analysis was conducted using SPSS version 21.0, with p values calculated using Quartile ratio, ANOVA unpaired t-test, and Kaplan-Meier Curve Method. A p-value of less than 0.05 was considered statistically significant. All participants underwent a questionnaire, physical examination, medical history assessment, and laboratory tests. The results of the study showed that there was a significant correlation between IL-6 and hsCRP levels in the Quartile groups, as well as with lipid profiles. The Kaplan-Meier method also demonstrated a significant association between IL-6 and hsCRP levels in participants. The comparison of biomarkers further supported these findings. Thus, data shows that elevated levels of hsCRP and IL-6 could serve as valuable diagnostic markers for predicting Acute Myocardial Infarction. Our study strongly suggests that IL-6 could be a powerful marker in evaluating the Myocardial Infarction.

10.
Article in English | MEDLINE | ID: mdl-37506007

ABSTRACT

Integration of multi-modal sensory inputs and modulation of motor outputs based on perceptual estimates is called Sensorimotor Integration (SMI). Optimal functioning of SMI is essential for perceiving the environment, modulating the motor outputs, and learning or modifying motor skills to suit the demands of the environment. Growing evidence suggests that patients diagnosed with Parkinson's Disease (PD) may suffer from an impairment in SMI that contributes to perceptual deficits, leading to motor abnormalities. However, the exact nature of the SMI impairment is still unclear. This study uses a robot-assisted assessment tool to quantitatively characterize SMI impairments in PD patients and how they affect voluntary movements. A set of assessment tasks was developed using a robotic manipulandum equipped with a virtual-reality system. The sensory conditions of the virtual environment were varied to facilitate the assessment of SMI. A hundred PD patients (before and after medication) and forty-three control subjects completed the tasks under varying sensory conditions. The kinematic measures obtained from the robotic device were used to evaluate SMI. The findings reveal that across all sensory conditions, PD patients had 36% higher endpoint error, 38% higher direction error in reaching tasks, and 43% higher number of violations in tracing tasks than control subjects due to impairment in integrating sensory inputs. However, they still retained motor learning ability and the ability to modulate motor outputs. The medication worsened the SMI deficits as PD patients, after medication, performed worse than before medication when encountering dynamic sensory environments and exhibited impaired motor learning ability.


Subject(s)
Parkinson Disease , Parkinson Disease/drug therapy , Humans , Male , Female , Middle Aged , Robotics , Machine Learning , Task Performance and Analysis
11.
Sci Rep ; 13(1): 4751, 2023 03 23.
Article in English | MEDLINE | ID: mdl-36959273

ABSTRACT

Sensorimotor control (SMC) is a complex function that involves sensory, cognitive, and motor systems working together to plan, update and execute voluntary movements. Any abnormality in these systems could lead to deficits in SMC, which would negatively impact an individual's ability to execute goal-directed motions. Recent studies have shown that patients diagnosed with Parkinson's disease (PD) have dysfunctions in sensory, motor, and cognitive systems, which could give rise to SMC deficits. However, SMC deficits in PD and how they affect a patient's upper-limb movements have not been well understood. The objective of the study was to investigate SMC deficits in PD and how they affect the planning and correction of upper-limb motions. This was accomplished using a robotic manipulandum equipped with a virtual-reality system. Twenty age-matched healthy controls and fifty-six PD patients (before and after medication) completed an obstacle avoidance task under dynamic conditions (target and obstacles in moving or stationary form, with and without mechanical perturbations). Kinematic information from the robot was used to extract eighteen features that evaluated the SMC functions of the participants. The findings show that the PD patients before medication were 32% slower, reached 16% fewer targets, hit 41% more obstacles, and were 26% less efficient than the control participants, and the difference in these features was statistically significant under dynamic conditions. In addition to the motor deficits, the PD patients also showed deficits in handling high cognitive loads and interpreting sensory cues. Further, the PD patients after medication exhibited worse sensory and cognitive performance than before medication under complex testing conditions. The PD patients also showed deficits in following the computational models leading to poor motor planning.


Subject(s)
Parkinson Disease , Robotics , Humans , Movement , Sensation , Cues , Psychomotor Performance
12.
Behav Brain Res ; 452: 114490, 2023 08 24.
Article in English | MEDLINE | ID: mdl-37172741

ABSTRACT

OBJECTIVE: Compared with motor deficits, sensory information processing in Parkinson's disease (PD) is relatively unexplored. While there is increasing interest in understanding the sensory manifestations of PD, the extent of sensory abnormality in PD has remained relatively unexplored. Furthermore, most investigations on the sensory aspects of PD involve motor aspects, causing confounding results. As sensory deficits often arise in early PD development stages, they present a potential technological target for diagnosis and disease monitoring that is affordable and accessible. Considering this, the current study's aim is to assess visual spatiotemporal perception independent of goal directed movements in PD by designing and using a scalable computational tool. METHODS: A flexible 2-D virtual reality environment was created to evaluate various cases of visual perception. Using the tool, an experimental task quantifying the visual perception of velocity was tested on 37 individuals with PD and 17 age-matched control participants. RESULTS: PD patients, both ON and OFF PD therapy, displayed perceptual impairments (p = 0.001 and p = 0.008, respectively) at slower tested velocity magnitudes. These impairments were even observed in early stages of PD (p = 0.015). CONCLUSION: Visual velocity perception is impaired in PD patients, which suggests impairments in visual spatiotemporal processing occur in PD and provides a promising modality to be used with disease monitoring software. SIGNIFICANCE: Visual velocity perception shows high sensitivity to PD at all stages of the disease. Dysfunction in visual velocity perception may contribute to observed motor dysfunction in PD.


Subject(s)
Parkinson Disease , Humans , Parkinson Disease/complications , Visual Perception , Vision, Ocular , Vision Disorders , Sensation
13.
Article in English | MEDLINE | ID: mdl-37882980

ABSTRACT

PURPOSE: We propose the utilization of patient-specific concentric-tube robots (CTRs) whose designs are optimized to enhance their volumetric reachability of the renal stone, thus reducing the morbidities associated with percutaneous nephrolithotomy procedures. By employing a nested optimization-driven scheme, this work aims to determine a single surgical tract through which the patient-tailored CTR is deployed. We carry out a sensitivity analysis on the combined percutaneous access and optimized CTR design with respect to breathing-induced excursion of the kidneys based on preoperative images. Further, an investigation is also performed of the appropriateness and effectiveness of the percutaneous access provided by the proposed algorithm compared to that of an expert urologist. METHODS: The method is based on an ellipsoidal approximation to the renal calculi and a grid search over candidate skin areas and available renal calyces using an anatomically constrained kinematic mapping of the CTR. Percutaneous access is selected for collision-free CTR deployment to the centroid of the stones with minimal positional error at the renal calyx. Further optimization of the CTR design results in a robot tailored to the therapeutic anatomical features of each clinical case. The study examined 14 sets of clinical data of PCNL patients, analyzing stone reachability using preoperative images and breathing-induced motions of the kidney. An experienced urologist qualitatively assessed the adequacy of percutaneous access generated by the algorithm. RESULTS: An assessment conducted by an expert urologist found that the percutaneous accesses produced by the proposed approach were found to be comparable to those chosen by the expert surgeon in most clinical cases. The simulated results demonstrated a mean volume coverage of [Formula: see text] for static anatomy and [Formula: see text] and [Formula: see text] when considering a 1 cm excursion of the kidney in the craniocaudal directions due to respiration or tool-tissue interaction. CONCLUSION: The optimization-driven scheme for determining a single tract surgical plan, coupled with the use of a patient-specific CTR, shows promising results for improving percutaneous access in PCNL procedures. This approach clearly shows the potential for enhancing the quality and suitability of percutaneous accesses, addressing the challenges posed by staghorn and non-staghorn stones during PCNL procedures. Further research involving clinical validation is necessary to confirm these findings and explore the potential clinical benefits of the approach.

14.
Med Phys ; 39(3): 1579-87, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22380390

ABSTRACT

PURPOSE: Although robot-assisted coronary artery bypass grafting (RA-CABG) has gained more acceptance worldwide, its success still depends on the surgeon's experience and expertise, and the conversion rate to full sternotomy is in the order of 15%-25%. One of the reasons for conversion is poor pre-operative planning, which is based solely on pre-operative computed tomography (CT) images. In this paper, the authors propose a technique to estimate the global peri-operative displacement of the heart and to predict the intra-operative target vessel location, validated via both an in vitro and a clinical study. METHODS: As the peri-operative heart migration during RA-CABG has never been reported in the literatures, a simple in vitro validation study was conducted using a heart phantom. To mimic the clinical workflow, a pre-operative CT as well as peri-operative ultrasound images at three different stages in the procedure (Stage(0)-following intubation; Stage(1)-following lung deflation; and Stage(2)-following thoracic insufflation) were acquired during the experiment. Following image acquisition, a rigid-body registration using iterative closest point algorithm with the robust estimator was employed to map the pre-operative stage to each of the peri-operative ones, to estimate the heart migration and predict the peri-operative target vessel location. Moreover, a clinical validation of this technique was conducted using offline patient data, where a Monte Carlo simulation was used to overcome the limitations arising due to the invisibility of the target vessel in the peri-operative ultrasound images. RESULTS: For the in vitro study, the computed target registration error (TRE) at Stage(0), Stage(1), and Stage(2) was 2.1, 3.3, and 2.6 mm, respectively. According to the offline clinical validation study, the maximum TRE at the left anterior descending (LAD) coronary artery was 4.1 mm at Stage(0), 5.1 mm at Stage(1), and 3.4 mm at Stage(2). CONCLUSIONS: The authors proposed a method to measure and validate peri-operative shifts of the heart during RA-CABG. In vitro and clinical validation studies were conducted and yielded a TRE in the order of 5 mm for all cases. As the desired clinical accuracy imposed by this procedure is on the order of one intercostal space (10-15 mm), our technique suits the clinical requirements. The authors therefore believe this technique has the potential to improve the pre-operative planning by updating peri-operative migration patterns of the heart and, consequently, will lead to reduced conversion to conventional open thoracic procedures.


Subject(s)
Coronary Angiography/methods , Coronary Artery Bypass/methods , Coronary Vessels/diagnostic imaging , Image Processing, Computer-Assisted/methods , Robotics/methods , Tomography, X-Ray Computed/methods , Algorithms , Humans , Preoperative Period , Ultrasonography
15.
Stud Health Technol Inform ; 173: 129-35, 2012.
Article in English | MEDLINE | ID: mdl-22356973

ABSTRACT

The complexity of knee arthroscopy makes it difficult to teach and assess skill level during real surgery. Simulator-based training is ideal for this complex procedure. To address the limitations of existing systems, a physical simulator, capable of providing skills assessment and feedback has been developed. The simulator measures the forces applied on the femur and acting on the tools. An experimental evaluation was conducted to assess the differences in task completion time and applied forces for fourteen tasks performed by trainees and expert surgeons. Initial results show that the simulator, together with well-chosen tasks, can potentially be used to assess user performance.


Subject(s)
Arthroscopy , Clinical Competence , Computer Simulation , Knee/surgery , Orthopedics , Touch Perception , Arthroscopy/standards , Humans , User-Computer Interface
16.
Med Image Comput Comput Assist Interv ; 13437: 626-635, 2022 Sep.
Article in English | MEDLINE | ID: mdl-37252091

ABSTRACT

Percutaneous nephrolithotomy (PCNL) is considered a first-choice minimally invasive procedure for treating kidney stones larger than 2 cm. It yields higher stone-free rates than other minimally invasive techniques and is employed when extracorporeal shock wave lithotripsy or uteroscopy are, for instance, infeasible. Using this technique, surgeons create a tract through which a scope is inserted for gaining access to the stones. Traditional PCNL tools, however, present limited maneuverability, may require multiple punctures and often lead to excessive torquing of the instruments which can damage the kidney parenchyma and thus increase the risk of hemorrhage. We approach this problem by proposing a nested optimization-driven scheme for determining a single tract surgical plan along which a patient-specific concentric-tube robot (CTR) is deployed so as to enhance manipulability along the most dominant directions of the stone presentations. The approach is illustrated with seven sets of clinical data from patients who underwent PCNL. The simulated results may set the stage for achieving higher stone-free rates through single tract PCNL interventions while decreasing blood loss.

17.
J Surg Educ ; 79(2): 492-499, 2022.
Article in English | MEDLINE | ID: mdl-34702691

ABSTRACT

BACKGROUND: Correct identification of the surgical tissue planes of dissection is paramount at the operating room, and the needed skills seem to be improved with realistic dynamic models rather than mere still images. The objective is to assess the role of adding video prequels to still images taken from operations on the precision and accuracy of tissue plane identification using a validated simulation model, considering various levels of surgeons' experience. METHODS: A prospective observational study was conducted involving 15 surgeons distributed to three equal groups, including a consultant group [C], a senior group [S], and a junior group [J]. Subjects were asked to identify and draw ideal tissue planes in 20 images selected at suitable operative moments of identification before and after showing a 10- second videoclip preceding the still image. A validated comparative metric (using a modified Hausdorff distance [%Hdu] for object matching) was used to measure the distance between lines. A precision analysis was carried out based on the difference in %Hdu between lines drawn before and after watching the videos, and between-group comparisons were analyzed using a one-way analysis of variance (ANOVA). The analysis of accuracy was done on the difference in %Hdu between lines drawn by the subjects and the ideal lines provided by an expert panel. The impact of videos on accuracy was assessed using a repeated-measures ANOVA. RESULTS: The C group showed the highest preciseness as compared to the S and J groups (mean Hdu 9.17±11.86 versus 12.1±15.5 and 20.0±18.32, respectively, p <0.001) and significant differences between groups were found in 14 images (70%). Considering the expert panel as a reference, the interaction between time and experience level was significant ( F (2, 597) = 4.52, p <0.001). Although the subjects of the J group were significantly less accurate than other surgeons, only this group showed significant improvements in mean %Hdu values after watching the lead-in videos ( F (1, 597) = 6.04, p = 0.014). CONCLUSIONS: Adding video context improved the ability of junior trainees to identify tissue planes of dissection. A realistic model is recommended considering experience-based differences in precision in training programs.


Subject(s)
Laparoscopy , Surgeons , Clinical Competence , Computer Simulation , Dissection , Humans , Laparoscopy/education , Prospective Studies , Video Recording
18.
Med Phys ; 38(2): 872-83, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21452724

ABSTRACT

PURPOSE: A novel technique is proposed to construct CT image of a totally deflated lung from a free-breathing 4D-CT image sequence acquired preoperatively. Such a constructed CT image is very useful in performing tumor ablative procedures such as lung brachytherapy. Tumor ablative procedures are frequently performed while the lung is totally deflated. Deflating the lung during such procedures renders preoperative images ineffective for targeting the tumor. Furthermore, the problem cannot be solved using intraoperative ultrasound (U.S.) images because U.S. images are very sensitive to small residual amount of air remaining in the deflated lung. One possible solution to address these issues is to register high quality preoperative CT images of the deflated lung with their corresponding low quality intraoperative U.S. images. However, given that such preoperative images correspond to an inflated lung, such CT images need to be processed to construct CT images pertaining to the lung's deflated state. METHODS: To obtain the CT images of deflated lung, we present a novel image construction technique using extrapolated deformable registration to predict the deformation the lung undergoes during full deflation. The proposed construction technique involves estimating the lung's air volume in each preoperative image automatically in order to track the respiration phase of each 4D-CT image throughout a respiratory cycle; i.e., the technique does not need any external marker to form a respiratory signal in the process of curve fitting and extrapolation. The extrapolated deformation field is then applied on a preoperative reference image in order to construct the totally deflated lung's CT image. The technique was evaluated experimentally using ex vivo porcine lung. RESULTS: The ex vivo lung experiments led to very encouraging results. In comparison with the CT image of the deflated lung we acquired for the purpose of validation, the constructed CT image was very similar. The intensity mean absolute difference between these two images was calculated to be at 1%. Tumor center as well as a number of anatomical fiducial markers were traced in different corresponding slices of the two images. The average misalignment obtained for the constructed CT image was (0.64, 0.39, 0.11) mm, which indicates a very desirable accuracy for lung brachytherapy applications. CONCLUSIONS: The image construction accuracy obtained in this research is suitable for intraoperative tasks; e.g., tumor localization and fusing with real time navigation data in lung brachytherapy. These applications involve image registration with intraoperative U.S. images in order to enhance their poor quality. The proposed technique is also useful for preoperative tasks such as planning of lung brachytherapy treatment.


Subject(s)
Image Processing, Computer-Assisted/methods , Lung/diagnostic imaging , Lung/physiology , Tomography, X-Ray Computed/methods , Animals , Four-Dimensional Computed Tomography , Lung/physiopathology , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/physiopathology , Lung Volume Measurements , Respiration
19.
Surg Endosc ; 25(1): 186-92, 2011 Jan.
Article in English | MEDLINE | ID: mdl-20559663

ABSTRACT

BACKGROUND: Natural orifice transluminal endoscopic surgery (NOTES) may represent the next frontier for therapeutic minimally invasive surgery; however, its feasibility is currently limited by the lack of suitable instruments. Identifying the forces required to manipulate tissue during NOTES is a necessary first step in the development of better instrumentation. METHODS: Sensorized instruments were used to measure the forces acting at the tip of the instruments during transgastric and transperineal NOTES procedures performed in two female pigs. The maximum and average forces when handling tissue were determined and compared. RESULTS: The results show that, for the transgastric approach, the average forces required are significantly less than in the transperineal approach (43% less), and that the maximum forces required are almost 8 and 16 N in the transgastric and transperineal approaches, respectively. The forces were higher than 5 N in 1.6% of the measurements in the transgastric approach and 2.9% in the transperineal approach. CONCLUSIONS: This study presents an experimental measurement of tissue manipulation forces in a NOTES procedure. This information may be valuable for research groups interested in developing NOTES instruments and devices. It is recommended that NOTES instruments be designed to easily handle forces as high as 16 N.


Subject(s)
Feedback, Sensory , Gastroscopes , Natural Orifice Endoscopic Surgery/instrumentation , Pressure , Surgical Instruments , Animals , Calibration , Equipment Design , Female , Humans , Perineum , Stomach , Stress, Mechanical , Sus scrofa , Swine , Touch
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 3526-3530, 2021 11.
Article in English | MEDLINE | ID: mdl-34892000

ABSTRACT

Intraoperative tumor localization in a deflated lung in minimally invasive surgery (MIS) is challenging as the lung cannot be manually palpated through small incisions. To do so remotely, an articulated multisensory imaging device combining tactile and ultrasound sensors was developed. It visualizes the surface tactile map and the depth of the tissue. However, with little maneuverability in MIS, localizing tumors using instrumented palpation is both tedious and inefficient. In this paper, a texture- based image guidance system that classifies tactile-guided ultrasound texture regions and provides beliefs on their types is proposed. The resulting interactive feedback allows directed palpation in MIS. A k-means classifier is used to first cluster gray-level co-occurrence matrix (GLCM)-based texture features of the ultrasound regions, followed by hidden Markov model-based belief propagation to establish confidence about the clustered features observing repeated patterns. When the beliefs converge, the system autonomously detects tumor and nontumor textures. The approach was tested on 20 ex vivo soft tissue specimens in a staged MIS. The results showed that with guidance, tumors in MIS could be localized with 98% accuracy, 99% sensitivity, and 97% specificity.Clinical Relevance- Texture-based image guidance adds efficiency and control to instrumented palpation in MIS. It renders fluidity and accuracy in image acquisition using a hand-held device where fatigue from prolonged handling affects imaging quality.


Subject(s)
Minimally Invasive Surgical Procedures , Neoplasms , Feedback , Humans , Palpation , Touch
SELECTION OF CITATIONS
SEARCH DETAIL