ABSTRACT
OBJECTIVE: To investigate the effectiveness of early versus delayed rehabilitation following total shoulder replacement. DESIGN: Intervention systematic review with narrative synthesis. LITERATURE SEARCH: MEDLINE, EMBASE, CINAHL, Scopus and the Cochrane Library were searched from inception to the 29th of July 2021. STUDY SELECTION CRITERIA: Randomised controlled trials comparing early versus delayed rehabilitation following primary anatomic, primary reverse, or revision total shoulder replacement. DATA SYNTHESIS: A revised Cochrane risk of bias assessment tool for randomised controlled trials was used, as well as the Grading of Recommendations Assessment, Development and Evaluation approach to evaluate the quality of evidence. A narrative synthesis was undertaken. RESULTS: Three eligible randomised controlled trials (n = 230) were included. There was very low-quality evidence of no statistically significant difference (P > 0.05) in pain, shoulder function, health-related quality of life or lesser tuberosity osteotomy healing at 12 months between early or delayed rehabilitation. There was conflicting and very low-quality evidence of a difference between the effect of early and delayed rehabilitation on shoulder range of movement. There was limited, very low-quality evidence of statistically significantly improved pain and function (P < 0.05) in the early post-operative period with early rehabilitation following anatomic total shoulder replacement. CONCLUSIONS: No differences were seen in patient-reported or clinician-reported outcomes at 12 months post-surgery between early and delayed rehabilitation following total shoulder replacement. There is very low-quality evidence that early rehabilitation may improve shoulder pain and function in the early post-operative phase following anatomic total shoulder replacement.
Subject(s)
Arthroplasty, Replacement, Shoulder , Humans , Quality of Life , Shoulder PainABSTRACT
BACKGROUND: Elbow arthroplasty (EA) is an established technique for the treatment of select distal humeral fractures, yet little data exists regarding the safety and outcome of EA in the presence of an open distal humeral fracture where the risk of periprosthetic infection is an even greater concern. We hypothesized that EA does not carry an increased risk of infection or other postoperative complications when performed for simple open distal humeral fractures. METHODS: Seventeen patients underwent total EA (n = 9) or hemiarthroplasty (n = 8) for an open distal humeral fracture. The open fracture component was classified according to the Orthopaedic Trauma Society system as "simple" or "complex." Outcome measures collected included the Mayo Elbow Performance Score (MEPS), range of motion, complications, and reoperations. Patients who underwent primary débridement and implantation were compared with those who underwent preliminary débridement procedures and subsequent staged arthroplasty. A systematic review of the existing literature was performed to analyze other reported cases and contextualize our findings. RESULTS: The mean follow-up was 46 months (range, 12-138 months). All fractures were multifragmentary and intra-articular. Sixteen patients had a "simple" open fracture and 1 had a "complex" fracture. The overall mean MEPS was 83 (range, 30-100; standard deviation ± 17), with a mean flexion-extension arc of 96°. Patients who underwent primary débridement and implantation demonstrated a higher mean flexion arc (116° vs. 79°, P = .02) than those who underwent staged arthroplasty. The mean MEPS was not significantly different between the groups (90 vs. 78, P = .12). Complications included asymptomatic ulna component loosening (n = 1), joint instability (n = 1), and symptomatic heterotopic ossification (n = 3). There were no deep or superficial infections recorded. CONCLUSION: EA is safe and effective when performed for simple open distal humeral fractures. Primary débridement and implantation may offer functional benefits over a staged approach.
Subject(s)
Arthroplasty, Replacement, Elbow , Elbow Joint , Fractures, Open , Humeral Fractures , Arthroplasty, Replacement, Elbow/methods , Elbow/surgery , Follow-Up Studies , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fractures, Open/surgery , Humans , Range of Motion, Articular , Retrospective Studies , Treatment OutcomeABSTRACT
BACKGROUND: Proximal humerus fractures are the third most common in the human body but their management remains controversial. Open reduction and internal fixation with plates is one of the leading modes of operative treatment for these fractures. The development of technologies and techniques for these plates, during the recent decades, promise a bright future for their clinical use. A comprehensive review of in vitro biomechanical studies is needed for the comparison of plates' mechanical performance and the testing methodologies. This will not only guide clinicians with plate selection but also with the design of future in vitro biomechanical studies. This review was aimed to systematically categorise and review the in vitro biomechanical studies of these plates based on their protocols and discuss their results. The technologies and techniques investigated in these studies were categorised and compared to reach a census where possible. METHODS AND RESULTS: Web of Science and Scopus database search yielded 62 studies. Out of these, 51 performed axial loading, torsion, bending and/or combined bending and axial loading while 11 simulated complex glenohumeral movements by using tendons. Loading conditions and set-up, failure criteria and performance parameters, as well as results for each study, were reviewed. Only two studies tested four-part fracture model while the rest investigated two- and three-part fractures. In ten studies, synthetic humeri were tested instead of cadaveric ones. In addition to load-displacement data, three-dimensional motion analysis systems, digital image correlation and acoustic emission testing have been used for measurement. CONCLUSIONS: Overall, PHILOS was the most tested plate and locking plates demonstrated better mechanical performance than non-locking ones. Conflicting results have been published for their comparison with non-locking blade plates and polyaxial locking screws. Augmentation with cement [calcium phosphate or poly(methyl methacrylate)] or allografts (fibular and femoral head) was found to improve bone-plate constructs' mechanical performance. Controversy still lies over the use of rigid and semi-rigid implants and the insertion of inferomedial screws for calcar region support. This review will guide the design of in vitro and in silico biomechanical tests and also supplement the study of clinical literature.
Subject(s)
Bone Plates , Mechanical Phenomena , Shoulder Fractures , Biomechanical Phenomena , HumansABSTRACT
BACKGROUND: Open reduction and internal fixation of proximal humerus fractures can be difficult to achieve adequate, complication free results due to osteopenia of the proximal humerus and unstable fracture patterns. This study aimed to compare the biomechanical properties of a novel hybrid fixed angle blade plate (Fx plate) with an established fixed angle locking plate (PHILOS plate). METHODS: A two-part fracture was simulated in synthetic composite humeri by creating a transverse osteotomy and 10 mm fracture gap at the surgical neck. After treating the fractures with either an Fx plate or a PHILOS plate, humeral head was fixed and the shaft was displaced in a cantilever fashion. For elastic tests, loading was along the frontal and sagittal plane to achieve varus/valgus and extension/flexion, respectively. In plastic tests, loading was in a varus direction to determine the constructs' resistance to varus collapse. RESULTS: In elastic tests, both construct types had higher peak load and stiffness in extension/flexion than varus/valgus. Fx plate constructs were significantly stiffer than PHILOS constructs in varus/valgus (mean: 7.590/6.900 vs. 6.609/6.091 N/mm; p < 0.001 for both) but significantly less stiff in extension/flexion (8.770/9.541 vs. 9.533/9.997 N/mm; p < 0.001 for extension, p < 0.05 for flexion). In varus plastic tests, significantly higher peak loads were reported for Fx plate than PHILOS (134.391 vs. 115.531 N; p < 0.001). CONCLUSIONS: In this fracture gap model, humeri implanted with a novel Fx plate provided higher varus/valgus stiffness but lower extension/flexion stiffness than a more traditional proximal humeral locking plate design (PHILOS).
Subject(s)
Bone Plates , Fracture Fixation, Internal , Mechanical Phenomena , Shoulder Fractures/surgery , Biomechanical Phenomena , Humans , Weight-BearingABSTRACT
BACKGROUND: Treatment of proximal humerus fractures with locking plates is associated with complications. We aimed to compare the biomechanical effects of removing screws and blade of a fixed angle locking plate and hybrid blade plate, on a two-part fracture model. METHODS: Forty-five synthetic humeri were divided into nine groups where four were implanted with a hybrid blade plate and the remaining with locking plate, to treat a two-part surgical neck fracture. Plates' head screws and blades were divided into zones based on their distance from fracture site. Two groups acted as a control for each plate and the remaining seven had either a vacant zone or blade swapped with screws. For elastic cantilever bending, humeral head was fixed and the shaft was displaced 5 mm in extension, flexion, valgus and varus direction. Specimens were further loaded in varus direction to investigate their plastic behaviour. RESULTS: In both plates, removal of inferomedial screws or blade led to a significantly larger drop in varus construct stiffness than other zones. In blade plate, insertion of screws in place of blade significantly increased the mean extension, flexion valgus and varus bending stiffness (24.458%/16.623%/19.493%/14.137%). In locking plate, removal of screw zones proximal to the inferomedial screws reduced extension and flexion bending stiffness by 26-33%. CONCLUSIONS: Although medial support improved varus stability, two inferomedial screws were more effective than blade. Proximal screws are important for extension and flexion. Mechanical consequences of screw removal should be considered when deciding the number and choice of screws and blade in clinic.
Subject(s)
Bone Plates/standards , Bone Screws/standards , Shoulder Fractures/pathology , Shoulder Fractures/surgery , Biomechanical Phenomena/physiology , Humans , Shoulder Fractures/physiopathologyABSTRACT
Aims: The primary aim of this study was to report the radiological outcomes of patients with a dorsally displaced distal radius fracture who were randomized to a moulded cast or surgical fixation with wires following manipulation and closed reduction of their fracture. The secondary aim was to correlate radiological outcomes with patient-reported outcome measures (PROMs) in the year following injury. Methods: Participants were recruited as part of DRAFFT2, a UK multicentre clinical trial. Participants were aged 16 years or over with a dorsally displaced distal radius fracture, and were eligible for the trial if they needed a manipulation of their fracture, as recommended by their treating surgeon. Participants were randomly allocated on a 1:1 ratio to moulded cast or Kirschner wires after manipulation of the fracture in the operating theatre. Standard posteroanterior and lateral radiographs were performed in the radiology department of participating centres at the time of the patient's initial assessment in the emergency department and six weeks postoperatively. Intraoperative fluoroscopic images taken at the time of fracture reduction were also assessed. Results: Patients treated with surgical fixation with wires had less dorsal angulation of the radius versus those treated in a moulded cast at six weeks after manipulation of the fracture; the mean difference of -4.13° was statistically significant (95% confidence interval 5.82 to -2.45). There was no evidence of a difference in radial shortening. However, there was no correlation between these radiological measurements and PROMs at any timepoint in the 12 months post-injury. Conclusion: For patients with a dorsally displaced distal radius fracture treated with a closed manipulation, surgical fixation with wires leads to less dorsal angulation on radiographs at six weeks compared with patients treated in a moulded plaster cast alone. However, the difference in dorsal angulation was small and did not correlate with patient-reported pain and function.
Subject(s)
Risk Adjustment , Shoulder/surgery , Arthroplasty, Replacement , Humans , Shoulder Joint/surgeryABSTRACT
AIMS: The aim of this study was to investigate the outcome of periprosthetic fractures of the humerus and to assess the uniformity of the classifications used for these fractures (including those around elbow and/or shoulder arthroplasties) by performing a systematic review of the literature. METHODS: A systematic search was conducted using the National Institute for Health and Care Excellence Healthcare Databases Advance Search. For inclusion, studies had to report clinical outcomes following the management of periprosthetic fractures of the humerus. The protocol was registered on the PROSPERO database. RESULTS: Overall, 40 studies were included, involving a total of 210 patients. The fractures were reported using very heterogeneous classification systems, as were the functional outcome scores. A total of 60 patients had nonoperative treatment with a 50% rate of nonunion. Fixation was undertaken in 99 patients; successful union was obtained in 93 (93%). Revision of either the humeral stem or the whole arthroplasty was reported in 79 patients with a high rate of union (n = 66; 84%), and a mean rate of complications of 29% (0% to 41%). CONCLUSION: This study highlighted a lack of uniformity in classifying these fractures and reporting the outcome of their treatment. The results may help to inform decision-making with patients, particularly about the rate of complications of nonoperative treatment. There is a need to improve the reporting of the pattern of these fractures using a uniform classification system, and the harmonization of the collection of data relating to the outcome of treatment. Based on this review, we propose a minimum dataset to be used in future studies. Cite this article: Bone Joint J 2022;104-B(4):416-423.
Subject(s)
Arthroplasty, Replacement , Elbow Joint , Periprosthetic Fractures , Arthroplasty, Replacement/adverse effects , Elbow Joint/surgery , Humans , Humerus/surgery , Periprosthetic Fractures/etiology , Periprosthetic Fractures/surgeryABSTRACT
OBJECTIVE: To undertake a UK-based James Lind Alliance (JLA) Priority Setting Partnership for elbow conditions and be representative of the views of patients, carers and healthcare professionals (HCPs). SETTING: This was a national collaborative study organised through the British Elbow and Shoulder Society. PARTICIPANTS: Adult patients, carers and HCPs who have managed or experienced elbow conditions, their carers and HCPs in the UK involved in managing of elbow conditions. METHODS: The rigorous JLA priority setting methodology was followed. Electronic and paper scoping surveys were distributed to identify potential research priority questions (RPQs). Initial responses were reviewed and a literature search was performed to cross-check categorised questions. Those questions already sufficiently answered were excluded and the remaining questions were ranked in a second survey according to priority for future elbow conditions research. Using the JLA methodology, responses from HCP and patients were combined to create a list of the top 18 questions. These were further reviewed in a dedicated multistakeholder workshop where the top 10 RPQs were agreed by consensus. RESULTS: The process was completed over 24 months. The initial survey resulted in 467 questions from 165 respondents (73% HCPs and 27% patients/carers). These questions were reviewed and combined into 46 summary topics comprising: tendinopathy, distal biceps pathology, arthritis, stiffness, trauma, arthroplasty and cubital tunnel syndrome. The second (interim prioritisation) survey had 250 respondents (72% HCP and 28% patients/carers). The top 18 ranked questions from this survey were taken to the final workshop where a consensus was reached on the top 10 RPQs. CONCLUSIONS: The top 10 RPQs highlight areas of importance that currently lack sufficient evidence to guide diagnosis, treatment and rehabilitation of elbow conditions. This collaborative process will guide researchers and funders regarding the topics that should receive most future attention and benefit patients and HCPs.
Subject(s)
Biomedical Research , Elbow Joint , Adult , Humans , Elbow , Caregivers , Health PersonnelABSTRACT
Arthroscopic long head of biceps tenotomy is an established technique for addressing shoulder pain associated with long head of biceps pathology. Arthroscopic techniques, compared with open surgery, have demonstrated improvements in outcomes for patients including rapid recovery, but either regional or general anesthesia is required, which is associated with complications. We describe a novel technique using a Nanoscope needle arthroscopy system that allows for long head of biceps tenotomy to be performed under local anesthetic in the outpatient or office setting.
ABSTRACT
The design of commercially available fixation plates and the materials used for their fabrication lead to the plates being stiffer than bone. Consequently, commercial plates are prone to induce bone stress shielding. In this study, three-dimensional fixation plates are designed using topology optimisation aiming to reduce the risk of bone stress shielding. Fixation plate designs were optimised by minimising the strain energy for three levels of volume reduction (i.e. 25%, 45% and 75%). To evaluate stress shielding, changes in bone stress due to the different fixation plate designs were determined on the fracture plane of an idealised shaft of a long bone under a four-point bending load considering the effect of a patient walking with crutches of a transverse fractured tibia. Topology optimisation is a viable approach to design less stiff plates with adequate mechanical strength considering high volume reductions, which consequently increased the stress transferred to the bone fracture plane minimising bone stress shielding.
Subject(s)
Bone Plates , Fractures, Bone/pathology , Fractures, Bone/surgery , Stress, Mechanical , Biomechanical PhenomenaABSTRACT
Partial articular supraspinatus tendon avulsion (PASTA) tears are common. However, there is no consensus on the optimal surgical technique for the management of grade 3 tears (>50%). The authors report a retrospective consecutive case series of 64 patients with grade 3 PASTA lesions. The patients were treated by 2 surgeons from 2 centers with the same transtendon repair technique and implant system. The preoperative Oxford Shoulder Score (OSS) was compared with the postoperative OSS at final follow-up (mean, 28 months). Significant improvement in mean OSS occurred from 19.2 (SD, 7.5) preoperatively to 39.8 (SD, 7.8) postoperatively (P=.0001), and patient satisfaction rates were high (88%). The authors believe that transtendon repair of PASTA lesions of 50% or more is beneficial. High-quality randomized controlled trials are required to compare the benefit of repair vs debridement alone. [Orthopedics. 2020;43(6):e533-e537.].
Subject(s)
Arthroscopy/methods , Rotator Cuff Injuries/physiopathology , Rotator Cuff Injuries/surgery , Shoulder Joint/physiopathology , Shoulder Joint/surgery , Adult , Aged , Female , Humans , Male , Middle Aged , Patient Satisfaction , Retrospective Studies , Treatment OutcomeABSTRACT
INTRODUCTION: The prevalence of shoulder arthroplasty (SA) is rising, but there is limited research evaluating rehabilitation following SA and whether there is an optimal approach remains unknown. The aim of this study was to understand current National Health Service (NHS) practice for rehabilitation following SA as a platform for conducting much needed further research. METHODS: Two reviewers independently undertook electronic searches for publicly available information sheets (PIS) from websites of NHS Trusts that included detail about rehabilitation following SA, for example, duration of immobilisation. One reviewer extracted data, and a second reviewer verified this. ETHICAL APPROVAL: Not required. RESULTS: Forty-three PIS from 40 Trusts were identified. Twenty-four referred to more than one type of arthroplasty (anatomic, reverse and hemiarthroplasty) but did not describe different approaches to rehabilitation based on prosthesis type. Twenty-five PIS provided some instruction regarding movement restrictions, which varied considerably. All PIS referred to postoperative immobilisation, typically with a sling, with median duration of 4 weeks (range 0 to 8). Thirty-four PIS reported commencing passive exercise immediately. Median time to commencing active exercise was 4 weeks (range 1 to 6) and 5 weeks (range 1 to 16) for resisted exercise. Median time expected to return to driving was 6 weeks (range 3 to 12) and general work 12 weeks (range 3 to 26). CONCLUSION: This study has highlighted significant heterogeneity between rehabilitation approaches following SA, not previously reported in the United Kingdom, with a lack of specific rehabilitation PIS for different prosthesis types. Our results will facilitate evaluation of rehabilitation strategies in future research.
Subject(s)
Arthroplasty, Replacement, Shoulder , State Medicine , Arthroplasty , Humans , Physical Therapy Modalities , United KingdomABSTRACT
Stabilisation of proximal humerus fractures remains a surgical challenge. Spatial subchondral support (S3) plate promises to overcome common complications associated with conventional proximal humerus plates. This study compared the biomechanical performance of S3 plate with a fixed-angle hybrid blade (Equinoxe Fx) plate and a conventional fixed-angle locking plate (PHILOS). The effects of removal of different S3 plate screws on the humeral stability were also investigated. A total of 20 synthetic left humeri were osteotomised transversely at the surgical neck to simulate a two-part fracture and were each treated with an S3 plate. Head screws were divided into three zones based on their distance from the fracture site. Specimens were divided into four equal groups where one group acted as a control with all screws and three groups had one of the screw zones missing. With humeral head fixed, humeral shaft was first displaced 5 mm in extension, flexion, valgus and varus direction (elastic testing) and then until 30 mm varus displacement (plastic testing). Load-displacement data were recorded to determine construct stiffness in elastic tests and assess specimens' varus stability under plastic testing. Removal of the screw nearest to the fracture site led to a 20.71% drop in mean elastic varus bending stiffness. Removal of the two inferomedial screw above it resulted in a larger drop. The proximal screw pair had the largest contribution to extension and flexion bending stiffness. Varus stiffness of S3 plate constructs was higher than PHILOS and Fx plate constructs. Stability of humeri treated with S3 plate depends on screws' number, orientation and location. Varus stiffness of S3 plate construct (10.54 N/mm) was higher than that of PHILOS (6.61 N/mm) and Fx (7.59 N/mm) plate constructs. We attribute this to S3 plates' thicker cross section, the 135° inclination of its screws with respect to the humeral shaft and the availability of pegs for subchondral support.
Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Internal/instrumentation , Materials Testing , Mechanical Phenomena , Shoulder Fractures/surgery , Biomechanical Phenomena , Elasticity , Weight-BearingABSTRACT
Optimal treatment of proximal humerus fractures remains controversial. Locking plates offer theoretical advantages but are associated with complications in the clinic. This study aimed to perform parametric design optimisation of proximal humerus plates to enhance their mechanical performance. A finite element (FE) model was developed that simulated a two-part proximal humerus fracture that had been treated with a Spatial Subchondral Support (S3) plate and subjected to varus bending. The FE model was validated against in vitro biomechanical test results. The predicted load required to apply 5 mm cantilever varus bending was only 0.728% lower. The FE model was then used to conduct a parametric optimisation study to determine the orientations of inferomedial plate screws that would yield minimum fracture gap change (i.e. optimal stability). The feasible design space was automatically identified by imposing clinically relevant constraints, and the creation process of each FE model for the design optimisation was automated. Consequently, 538 FE models were generated, from which the obtained optimal model had 4.686% lower fracture gap change (0.156 mm) than that of the manufacturer's standard plate. Whereas its screws were oriented towards the inferomedial region and within the range of neck-shaft angle of a healthy subject. The methodology presented in this study promises future applications in patient-specific design optimisation of implants for other regions of the human body.
Subject(s)
Bone Plates , Bone Screws , Humeral Fractures , Humerus , Models, Biological , Prosthesis Design , Biomechanical Phenomena , Finite Element Analysis , Humans , Humeral Fractures/pathology , Humeral Fractures/physiopathology , Humeral Fractures/surgery , Humerus/pathology , Humerus/physiopathology , Humerus/surgeryABSTRACT
Plate-based treatment of proximal humerus fractures is associated with a high risk of complications such as screw perforation into glenohumeral joint. Smooth and threaded pegs were developed with the hope of minimising these risks. No consensus exists onto which threading profile achieves stiffest bone-plate construct. This study investigated the biomechanical effect of five percentages of threading on individual humeral head screws on a bone-plate construct. A finite element model simulating a two-part proximal humerus fracture treated with a Spatial Subchondral Support plate was developed and validated against in vitro biomechanical tests. The proportion of the humeral head screw length that was threaded was varied between 0%-100% in 25% increments. A 5-mm cantilever varus displacement was applied and the required load (F5) was calculated. Full (100%) threading achieved the stiffest construct for all six screws. Fully threading all smooth pegs at once increased F5 by 18%. Threading did not increase F5 equally in all screws. Inferior three plate screws exhibited a larger increase in stiffness than superior three. Most of the mechanical benefits of threading in inferior three screws can be achieved by using threaded pegs (50% threading) while the superior three screws need to be fully threaded. In practice, the smooth surface profile may also offer additional mechanical benefits if implanted with longer lengths and larger diameters. Threading is an effective way of increasing the varus bending stiffness of proximal humerus plates constructs.
Subject(s)
Bone Screws , Finite Element Analysis , Humeral Head , Mechanical Phenomena , Shoulder Fractures/surgery , Stress, Mechanical , Weight-BearingABSTRACT
Triceps tendon ruptures are rare injuries and are frequently missed on initial presentation to the emergency department. In cases of complete rupture, surgical repair is recommended but no guidelines exist on the optimum reconstructive technique or rehabilitation. We present a surgical technique and rehabilitation programme for the management of these injuries. A midline posterior incision is performed, the ruptured triceps tendon is identified and mobilized, and the tendon footprint is prepared. The tendon is then repaired using bone suture anchors, with a parachute technique, and held in 40° of flexion. The rehabilitation programme is divided into five phases, over a period of 12 weeks. Range of movement is gradually increased in a brace for the first 6 weeks. Rehabilitation is gradually increase in intensity, progressing from isometric extension exercises to weight-resisted exercises, and finally plyometrics and throwing exercises. Our surgical technique provides a solid tendon repair without the need for further metalwork removal. The graduated rehabilitation programme also helps to protect the integrity of the repair at the same time as enabling patients to gradually increase the strength of the triceps tendon and ultimately return to sport activities.
ABSTRACT
INTRODUCTION: The complex anatomy and biomechanics of the elbow joint can lead to diagnostic uncertainty when a clinician is determining the cause of a patient's anterior elbow pain. We present a case of anterior elbow pain with an uncommon and often overlooked etiology. Elbow pain due to compression of the lateral antebrachial nerve (LACN) has an unknown incidence or prevalence. CASE REPORT: A 27-year-old left-hand dominant male presented to our orthopedic elbow clinic complaining of bilateral elbow clicking and discomfort which had been present for several years. His painful symptoms were localized to the anterior aspect of both elbows and had slowly become more painful despite simple analgesia and physiotherapy. Examination revealed the full range of movement of both elbows with no instability or weakness. Plain imaging and magnetic resonance imaging scans of both elbows did not reveal any pathology, and the decision was made to explore the right elbow, as this was the most symptomatic. Under general anesthesia with tourniquet an anterior curvilinear antecubital fossa incision was made. The lateral border of the distal biceps tendon showed evidence of compression of the LACN at the musculotendinous junction. The tendon was partially resected, and the nerve confirmed to move freely without further entrapment. At 4 weeks after surgery, he was completely asymptomatic. The patient was later listed to undergo a similar procedure to the left side; however, he could not go ahead with surgery so far due to work commitment. CONCLUSION: Entrapment or compression of the LACN is an uncommon and often misdiagnosed differential diagnosis with patients presenting with anterior elbow pain, which can lead to permanent neurological damage if left untreated. A high index of suspicion is required to enable prompt diagnosis and investigation as surgical treatment has a high success rate, often with complete resolution of symptoms.