Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Eur Radiol ; 34(2): 842-851, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37606664

ABSTRACT

OBJECTIVES: To explore the use of deep learning-constrained compressed sensing (DLCS) in improving image quality and acquisition time for 3D MRI of the brachial plexus. METHODS: Fifty-four participants who underwent contrast-enhanced imaging and forty-one participants who underwent unenhanced imaging were included. Sensitivity encoding with an acceleration of 2 × 2 (SENSE4x), CS with an acceleration of 4 (CS4x), and DLCS with acceleration of 4 (DLCS4x) and 8 (DLCS8x) were used for MRI of the brachial plexus. Apparent signal-to-noise ratios (aSNRs), apparent contrast-to-noise ratios (aCNRs), and qualitative scores on a 4-point scale were evaluated and compared by ANOVA and the Friedman test. Interobserver agreement was evaluated by calculating the intraclass correlation coefficients. RESULTS: DLCS4x achieved higher aSNR and aCNR than SENSE4x, CS4x, and DLCS8x (all p < 0.05). For the root segment of the brachial plexus, no statistically significant differences in the qualitative scores were found among the four sequences. For the trunk segment, DLCS4x had higher scores than SENSE4x (p = 0.04) in the contrast-enhanced group and had higher scores than SENSE4x and DLCS8x in the unenhanced group (all p < 0.05). For the divisions, cords, and branches, DLCS4x had higher scores than SENSE4x, CS4x, and DLCS8x (all p ≤ 0.01). No overt difference was found among SENSE4x, CS4x, and DLCS8x in any segment of the brachial plexus (all p > 0.05). CONCLUSIONS: In three-dimensional MRI for the brachial plexus, DLCS4x can improve image quality compared with SENSE4x and CS4x, and DLCS8x can maintain the image quality compared to SENSE4x and CS4x. CLINICAL RELEVANCE STATEMENT: Deep learning-constrained compressed sensing can improve the image quality or accelerate acquisition of 3D MRI of the brachial plexus, which should be benefit in evaluating the brachial plexus and its branches in clinical practice. KEY POINTS: •Deep learning-constrained compressed sensing showed higher aSNR, aCNR, and qualitative scores for the brachial plexus than SENSE and CS at the same acceleration factor with similar scanning time. •Deep learning-constrained compressed sensing at acceleration factor of 8 had comparable aSNR, aCNR, and qualitative scores to SENSE4x and CS4x with approximately half the examination time. •Deep learning-constrained compressed sensing may be helpful in clinical practice for improving image quality and acquisition time in three-dimensional MRI of the brachial plexus.


Subject(s)
Brachial Plexus , Deep Learning , Humans , Imaging, Three-Dimensional/methods , Brachial Plexus/diagnostic imaging , Magnetic Resonance Imaging/methods , Signal-To-Noise Ratio
2.
Eur Radiol ; 32(2): 1044-1053, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34477909

ABSTRACT

OBJECTIVES: To investigate the feasibility of automatic machine learning (autoML) based on native T1 mapping to predict late gadolinium enhancement (LGE) status in hypertrophic cardiomyopathy (HCM). METHODS: Ninety-one HCM patients and 44 healthy controls who underwent cardiovascular MRI were enrolled. The native T1 maps of HCM patients were classified as LGE ( +) or LGE (-) based on location-matched LGE images. An autoML pipeline was implemented using the tree-based pipeline optimization tool (TPOT) for 3 binary classifications: LGE ( +) and LGE (-), LGE (-) and control, and HCM and control. TPOT modeling was repeated 10 times to obtain the optimal model for each classification. The diagnostic performance of the best models by slice and by case was evaluated using sensitivity, specificity, accuracy, and microaveraged area under the curve (AUC). RESULTS: Ten prediction models were generated by TPOT for each of the 3 binary classifications. The diagnostic accuracy obtained with the best pipeline in detecting LGE status in the testing cohort of HCM patients was 0.80 by slice and 0.79 by case. In addition, the TPOT model also showed discriminability between LGE (-) patients and control (accuracy: 0.77 by slice; 0.78 by case) and for all HCM patients and controls (accuracy: 0.88 for both). CONCLUSIONS: Native T1 map analysis based on autoML correlates with LGE ( +) or (-) status. The TPOT machine learning algorithm could be a promising method for predicting myocardial fibrosis, as reflected by the presence of LGE in HCM patients without the need for late contrast-enhanced MRI sequences. KEY POINTS: • The tree-based pipeline optimization tool (TPOT) is a machine learning algorithm that could help predict late gadolinium enhancement (LGE) status in patients with hypertrophic cardiomyopathy. • The TPOT could serve as an adjuvant method to detect LGE by using information from native T1 maps, thus avoiding the need for contrast agent. • The TPOT also detects native T1 map alterations in LGE-negative patients with hypertrophic cardiomyopathy.


Subject(s)
Cardiomyopathy, Hypertrophic , Contrast Media , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/diagnostic imaging , Fibrosis , Gadolinium , Humans , Machine Learning , Magnetic Resonance Imaging, Cine , Myocardium/pathology
3.
Eur Radiol ; 32(11): 7647-7656, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35567605

ABSTRACT

OBJECTIVES: We aimed to evaluate myocardial fibrosis using cardiac magnetic resonance (CMR) T1 mapping in type 2 diabetes mellitus (T2DM) patients and investigate the association between left ventricular (LV) subclinical myocardial dysfunction and myocardial fibrosis. METHODS: The study included 37 short-term (≤ 5 years) and 44 longer-term (> 5 years) T2DM patients and 41 healthy controls. The LV global strain parameters and T1 mapping parameters were compared between the abovementioned three groups. The association of T1 mapping parameters with diabetes duration, in addition to other risk factors, was determined using multivariate linear regression analysis. The correlation between LV strain parameters and T1 mapping parameters was evaluated using Pearson's correlation. RESULTS: The peak diastolic strain rates (PDSRs) were significantly lower in longer-term T2DM patients compared to those in healthy subjects and short-term T2DM patients (p < 0.05). The longitudinal peak systolic strain rate and peak strain were significantly lower in the longer-term T2DM compared with the short-term T2DM group (p < 0.05). The extracellular volumes (ECVs) were higher in both subgroups of T2DM patients compared with control subjects (all p < 0.05). Multivariate linear regression analysis showed that diabetes duration was independently associated with ECV (ß = 0.413, p < 0.001) by taking covariates into account. Pearson's analysis showed that ECV was associated with longitudinal PDSR (r = - 0.441, p < 0.001). CONCLUSION: T1 mapping could detect abnormal myocardial fibrosis early in patients with T2DM, which can cause a decline in the LV diastolic function. KEY POINTS: • CMR T1 mapping could detect abnormal myocardial fibrosis early in patients with T2DM. • The diabetes duration was independently associated with ECV. • Myocardial fibrosis can cause a decline in the LV diastolic function in T2DM patients.


Subject(s)
Cardiomyopathies , Diabetes Mellitus, Type 2 , Ventricular Dysfunction, Left , Humans , Diabetes Mellitus, Type 2/pathology , Magnetic Resonance Imaging, Cine/adverse effects , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left , Myocardium/pathology , Fibrosis , Magnetic Resonance Spectroscopy , Predictive Value of Tests
4.
J Magn Reson Imaging ; 54(1): 284-289, 2021 07.
Article in English | MEDLINE | ID: mdl-33433045

ABSTRACT

The safety profiles when performing stress oxygenation-sensitive magnetic resonance imaging (OS-MRI) have raised concerns in clinical practice. Adenosine infusion can cause side effects such as chest pain, dyspnea, arrhythmia, and even cardiac death. The aim of this study was to investigate the feasibility of breathing maneuvers-induced OS-MRI in acute myocardial infarction (MI). This was a prospective study, which included 14 healthy rabbits and nine MI rabbit models. This study used 3 T MRI/modified Look-Locker inversion recovery sequence for native T1 mapping, balanced steady-state free precession sequence for OS imaging, and phase-sensitive inversion recovery sequence for late gadolinium enhancement. The changes in myocardial oxygenation (ΔSI) were assessed under two breathing maneuvers protocols in healthy rabbits: a series of extended breath-holding (BH), and a combined maneuver of hyperventilation followed by the extended BH (HVBH). Subsequently, OS-MRI with HVBH in acute MI rabbits was performed, and the ΔSI was compared with that of adenosine stress protocol. Student's t-test, Wilcoxon rank test, and Friedman test were used to compare ΔSI in different subgroups. Pearson and Spearman correlation was used to obtain the association of ΔSI between breathing maneuvers and adenosine stress. Bland-Altman analysis was used to assess the bias of ΔSI between HVBH and adenosine stress. In healthy rabbits, BH maneuvers from 30 to 50 s induced significant increase in SI compared with the baseline (all p < 0.05). By contrast, hyperventilation for 60 s followed by 10 s-BH (HVBH 10 s) exhibited a comparable ΔSI to that of stress test (p = 0.07). In acute MI rabbits, HVBH 10 s-induced ΔSIs among infarcted, salvaged, and the remote myocardial area were no less effectiveness than adenosine stress when performing OS-MRI (r = 0.84; p < 0.05). Combined breathing maneuvers with OS-MRI have the potential to be used as a nonpharmacological alternative for assessing myocardial oxygenation in patients with acute MI. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2.


Subject(s)
Magnetic Resonance Imaging, Cine , Myocardial Infarction , Animals , Contrast Media , Gadolinium , Humans , Magnetic Resonance Imaging , Myocardial Infarction/diagnostic imaging , Myocardium , Prospective Studies , Rabbits
5.
Eur Radiol ; 31(12): 8956-8966, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34003352

ABSTRACT

OBJECTIVES: To explore the relationships between oxygenation signal intensity (SI) with myocardial inflammation and regional left ventricular (LV) remodeling in reperfused acute ST-segment elevation myocardial infarction (STEMI) using oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR). METHODS: Thirty-three STEMI patients and 22 age- and sex-matched healthy volunteers underwent CMR. The protocol included cine function, OS imaging, precontrast T1 mapping, T2 mapping, and late gadolinium enhancement (LGE) imaging. A total of 880 LV segments were included for analysis based on the American Heart Association 16-segment model. For validation, 15 pigs (10 myocardial infarction (MI) model animals and 5 controls) received CMR and were sacrificed for immunohistochemical analysis. RESULTS: In the patient study, the acute oxygenation SI showed a stepwise rise among remote, salvaged, and infarcted segments compared with healthy myocardium. At convalescence, all oxygenation SI values besides those in infarcted segments with microvascular obstruction decreased to similar levels. Acute oxygenation SI was associated with early myocardial injury (T1: r = 0.38; T2: r = 0.41; all p < 0.05). Segments with higher acute oxygenation SI values exhibited thinner diastolic walls and decreased wall thickening during follow-up. Multivariable regression modeling indicated that acute oxygenation SI (ß = 2.66; p < 0.05) independently predicted convalescent segment adverse remodeling (LV wall thinning). In the animal study, alterations in oxygenation SI were correlated with histological inflammatory infiltrates (r = 0.59; p < 0.001). CONCLUSIONS: Myocardial oxygenation by OS-CMR could be used as a quantitative imaging biomarker to assess myocardial inflammation and predict convalescent segment adverse remodeling after STEMI. KEY POINTS: • Oxygenation signal intensity (SI) may be an imaging biomarker of inflammatory infiltration that could be used to assess the response to anti-inflammatory therapies in the future. • Oxygenation SI early after myocardial infarction (MI) was associated with left ventricular segment injury at acute phase and could predict regional functional recovery and adverse remodeling late after acute MI. • Oxygenation SI demonstrated a stepwise increase among remote, salvaged, and infarcted segments. Infarcted zones with microvascular obstruction demonstrated a higher oxygenation SI than those without. However, the former showed less pronounced changes over time.


Subject(s)
Myocardial Infarction , ST Elevation Myocardial Infarction , Animals , Contrast Media , Gadolinium , Humans , Inflammation/diagnostic imaging , Magnetic Resonance Imaging, Cine , Myocardial Infarction/diagnostic imaging , Myocardium , Predictive Value of Tests , ST Elevation Myocardial Infarction/diagnostic imaging , Swine , Ventricular Function, Left , Ventricular Remodeling
6.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(5): 819-824, 2021 Sep.
Article in Zh | MEDLINE | ID: mdl-34622599

ABSTRACT

OBJECTIVE: To explore the diagnostic performance of deep learning (DL) model in early detection of the interstitial myocardial fibrosis using native T1 maps of hypertrophic cardiomyopathy (HCM) without late gadolinium enhancement (LGE). METHODS: Sixty HCM patients and 44 healthy volunteers who underwent cardiac magnetic resonance were enrolled in this study. Each native T1 map was labeled according to its LGE status. Then, native T1 maps of LGE (-) and those of the controls were preprocessed and entered in the SE-ResNext-50 model as the matrix for the DL model for training, validation and testing. RESULTS: A total of 241 native T1 maps were entered in the SE-ResNext-50 model. The model achieved a specificity of 0.87, sensitivity of 0.79, and area under curve ( AUC) of 0.83 ( P<0.05) in distinguishing native T1 maps of LGE (-) from those of the controls in the testing set. CONCLUSION: The DL model based on SE-ResNext-50 could be used for identifying native T1 maps of LGE (-) with relatively high accuracy. It is a promising approach for early detection of myocardial fibrosis in HCM without the use of contrast agent.


Subject(s)
Cardiomyopathy, Hypertrophic , Deep Learning , Cardiomyopathy, Hypertrophic/diagnostic imaging , Contrast Media , Fibrosis , Gadolinium , Humans
7.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(1): 92-97, 2021 Jan.
Article in Zh | MEDLINE | ID: mdl-33474896

ABSTRACT

OBJECTIVE: To evaluate the diagnostic value of 3.0T time-of-flight MR angiography with sparse undersampling and iterative reconstruction (TOFu-MRA) for unruptured intracranial aneurysms (UIAs) on the basis of using digital subtraction angiography (DSA) as the reference standard. METHODS: A total of 65 patients with suspected UIAs were prospectively enrolled and all patients underwent TOFu-MRA and DSA. Relying on DSA as the reference standard, the sensitivity (SEN), specificity (SPE), positive predictive value (PPV) and negative predictive value (NPV) of using TOFu-MRA in UIA diagnosis were calculated, and the inter-observer agreement between two doctors was determined. Comparison of maximum intensity projection (MIP) and volume rendering (VR) image datasets was made to evaluate the agreement between DSA results and TOFu-MRA in the measurement of UIA morphological parameters, including the neck width (D neck), height (H) , and width (D width) of UIAs. RESULTS: The study covered 55 UIAs from 46 patients. The SEN, SPE, PPV and NPV of the two doctors using TOFu-MRA in UIA diagnosis were as follows: (95.7%, 95.7%), (94.7%, 94.7%), (97.8%, 97.8%) and (90.0%, 90.0%), respectively for patient-based assessment; (96.4%, 94.5%), (94.7%, 94.7%), (98.1%, 98.1%) and (90.0%, 85.7%), respectively, for aneurysm-based assessment. There is a strong inter-observer agreement (Kappa=0.93 for patient-based assessment and 0.96 for aneurysm-based assessment) between the two doctors. Moreover, Bland-Altman analysis showed that more than 95% points fell within the limits of agreement (LoA), suggesting strong agreement between the two examination methods for the measurement of UIAs morphological parameters. CONCLUSION: TOFu-MRA showed good diagnostic efficacy for UIAs and the results were in good agreement with those of DSA, the reference standard, for assessing UIA morphological parameter. TOFu-MRA can be used as a first choice for noninvasive diagnostic evaluation of UIAs.


Subject(s)
Intracranial Aneurysm , Magnetic Resonance Angiography , Angiography, Digital Subtraction , Humans , Intracranial Aneurysm/diagnostic imaging , Sensitivity and Specificity , Tomography, X-Ray Computed
8.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(2): 286-292, 2021 Mar.
Article in Zh | MEDLINE | ID: mdl-33829704

ABSTRACT

OBJECTIVE: To evaluate the noise reduction effect of deep learning-based reconstruction algorithms in thin-section chest CT images by analyzing images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and deep learning image reconstruction (DLIR) algorithms. METHODS: The chest CT scan raw data of 47 patients were included in this study. Images of 0.625 mm were reconstructed using six reconstruction methods, including FBP, ASIR hybrid reconstruction (ASIR50%, ASIR70%), and deep learning low, medium and high modes (DL-L, DL-M, and DL-H). After the regions of interest were outlined in the aorta, skeletal muscle and lung tissue of each group of images, the CT values, SD values and signal-to-noise ratio (SNR) of the regions of interest were measured, and two radiologists evaluated the image quality. RESULTS: CT values, SD values and SNR of the images obtained by the six reconstruction methods showed statistically significant difference ( P<0.001). There were statistically significant differences in the image quality scores of the six reconstruction methods ( P<0.001). Images reconstruced with DL-H have the lowest noise and the highest overall quality score. CONCLUSION: The model based on deep learning can effectively reduce the noise of thin-section chest CT images and improve the image quality. Among the three deep-learning models, DL-H showed the best noise reduction effect.


Subject(s)
Deep Learning , Algorithms , Humans , Image Processing, Computer-Assisted , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed
9.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(2): 293-299, 2021 Mar.
Article in Zh | MEDLINE | ID: mdl-33829705

ABSTRACT

OBJECTIVE: To compare the noise reduction performance of conventional filtering and artificial intelligence-based filtering and interpolation (AIFI) and to explore for optimal parameters of applying AIFI in the noise reduction of abdominal magnetic resonance imaging (MRI). METHODS: Sixty patients who underwent upper abdominal MRI examination in our hospital were retrospectively included. The raw data of T1-weighted image (T1WI), T2-weighted image (T2WI), and dualecho sequences were reconstructed with two image denoising techniques, conventional filtering and AIFI of different levels of intensity. The difference in objective image quality indicators, peak signal-to-noise ratio (pSNR) and image sharpness, of the different denoising techniques was compared. Two radiologists evaluated the image noise, contrast, sharpness, and overall image quality. Their scores were compared and the interobserver agreement was calculated. RESULTS: Compared with the original images, improvement of varying degrees were shown in the pSNR and the sharpness of the images of the three sequences, T1W1, T2W2, and dual echo sequence, after denoising filtering and AIFI were used (all P<0.05). In addition, compared with conventional filtering, the objective quality scores of the reconstructed images were improved when conventional filtering was combined with AIFI reconstruction methods in T1WI sequence, AIFI level≥3 was used in T2WI and echo1 sequence, and AIFI level≥4 was used in echo2 sequence (all P<0.05). The subjective scores given by the two radiologists for the image noise, contrast, sharpness, and overall image quality in each sequence of conventional filtering reconstruction, AIFI reconstruction (except for AIFI level=1), and two-method combination reconstruction were higher than those of the original images (all P<0.05). However, the image contrast scores were reduced for AIFI level=5. There was good interobserver agreement between the two radiologists (all r>0.75, P<0.05). After multidimensional comparison, the optimal parameters of using AIFI technique for noise reduction in abdominal MRI were conventional filtering+AIFI level=3 in the T1WI sequence and AIFI level=4 in the T2WI and dualecho sequences. CONCLUSION: AIFI is superior to filtering in imaging denoising at medium and high levels. It is a promising noise reduction technique. The optimal parameters of using AIFI for abdominal MRI are Filtering+AIFI level=3 in the T1WI sequence and AIFI level=4 in T2WI and dualecho sequences.


Subject(s)
Artificial Intelligence , Magnetic Resonance Imaging , Algorithms , Humans , Image Processing, Computer-Assisted , Retrospective Studies
10.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(2): 306-310, 2021 Mar.
Article in Zh | MEDLINE | ID: mdl-33829707

ABSTRACT

OBJECTIVE: To assess the clinical effectiveness of boundary recognition of upper abdomen organs on CT images based on neural network model and the combination of different slices. METHODS: A total of 2 000 patients who underwent upper abdomen enhanced CT scans from March 2018 to March 2019 were included in the study. The quality of the CT images met the requirements for clinical diagnosis. Eight boundary layers (the upper and lower edge of liver, the upper and lower edge of spleen, the lower edge of left kidney, the lower edge of right kidney, the lower edge of the stomach and the lower edge of the gallbladder) of the main organs in the upper abdomen were labeled. The model training (training set, verification set and test set) based on different neural network methods and combinations of different slices were then performed to assess the accuracy of boundary recognition. Furthermore, clinical data from 50 cases were used as test group for assessing the accuracy and clinical effectiveness of this model. RESULTS: The fusion model created by integrating the two models according to different weight ratios yielded the highest accuracy, and then followed the EfficientNet-b3 model, with the Xception model showing the lowest accuracy. In each model, the boundary recognition accuracy of 5-slice image is higher than that of 3-silce image, and that of 1-slice image is the lowest. The recognition accuracy of fusion model of the 5-continuous-slice image for upper edge of liver, lower edge of liver, upper edge of spleen, lower edge of spleen, lower edge of left kidney, lower edge of right kidney, lower edge of stomach and lower edge of gallbladder was 91%, 87%, 92%, 85%, 92%, 95%, 76% and 74%, respectively. The fusion model was checked with the effectiveness data of 50 cases, yielding 88%, 86%, 88%, 80%, 82%, 80%, 69%, and 65% accuracy for 8-slice image, respectively, and the accuracy of meeting clinical application requirement was as high as 98%, 98%, 95%, 98%, 99%, 98%, 80% and 77%, respectively. CONCLUSION: By increasing boundary change logics in the continuous slices, the fusion model integrating different weight proportions demonstrates the highest accuracy for identifying the boundary of upper abdominal organs on CT images, achieving high examination effectiveness in clinical practice.


Subject(s)
Neural Networks, Computer , Tomography, X-Ray Computed , Abdomen/diagnostic imaging , Humans , Spleen/diagnostic imaging , Treatment Outcome
11.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 52(5): 807-812, 2021 Sep.
Article in Zh | MEDLINE | ID: mdl-34622597

ABSTRACT

OBJECTIVE: To explore the clinical feasibility of applying deep learning (DL) reconstruction algorithm in low-dose thin-slice liver CT examination of healthy volunteers by comparing the reconstruction algorithm based on DL, filtered back projection (FBP) reconstruction algorithm and iterative reconstruction (IR) algorithm. METHODS: A standard water phantom with a diameter of 180 mm was scanned, using the 160 slice multi-detector CT scanning of United Imaging Healthcare, to compare the noise power spectrums of DL, FBP and IR algorithms. 100 healthy volunteers were prospectively enrolled, with 50 assigned to the normal dose group (ND) and 50 to the low dose group (LD). IR algorithm was used in the ND group to reconstruct images, while DL, FBP and IR algorithms were used in the LD group to reconstruct images. One-way analysis of variance was used to compare the liver CT values, the liver noise, liver signal-to-noise ratio (SNR), contrast noise ratio (CNR) and figure of merit (FOM) of the images of ND-IR, LD-FBP, LD-IR and LD-DL. The Kruskal-Wallis test was used to analyse subjective scores of anatomical structures. RESULTS: The DL algorithm had the lowest average peak value of noise power spectrum, and its shape was similar to that of medium-level IR algorithm. Liver CT values of ND-IR, LD-FBP, LD-IR and LD-DL did not show statistically significant difference. The noise of LD-DL was lower than that of LD-FBP, LD-IR and ND-IR ( P<0.05), and the SNR, CNR and FOM of LD-DL were higher than those of LD-FBP, LD-IR and ND-IR ( P<0.05). The subjective scores of anatomical structures of LD-DL did not show significant difference compared to those of ND-IR ( P >0.05), and were higher than those of LD-FBP and LD-IR. The radiation dose of the LD group was reduced by about 50.2% compared with that of the ND group. CONCLUSION: The DL algorithm with noise shape similar to the medium iterative grade IR commonly used in clinical practice showed higher noise reduction ability than IR did. Compared with FBP, the DL algorithm had smoother noise shape, but much better noise reduction ability. The application of DL algorithm in low-dose thin-slice liver CT of healthy volunteers can help achieve the standard image quality of liver CT.


Subject(s)
Deep Learning , Algorithms , Healthy Volunteers , Humans , Liver/diagnostic imaging , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed
13.
BMC Cardiovasc Disord ; 20(1): 12, 2020 01 10.
Article in English | MEDLINE | ID: mdl-31924159

ABSTRACT

BACKGROUND: End-stage renal disease (ESRD) patients are at high cardiovascular risk, and myocardial fibrosis (MF) accounts for most of their cardiac events. The purpose of this study is to investigate the prognostic value and risk stratification of MF as measured by extracellular volume (ECV) on cardiac magnetic resonance (CMR) for heart failure (HF) in patients with hemodialysis-dependent ESRD. METHODS: Sixty-six hemodialysis ESRD patients and 25 matched healthy volunteers were prospectively enrolled and underwent CMR to quantify multiple parameters of MF by T1 mapping and late gadolinium enhancement (LGE). All ESRD patients were followed up for 11-30 months, and the end-point met the 2016 ESC guidelines for the definition of HF. RESULTS: Over a median follow-up of 18 months (range 11-30 months), there were 26 (39.39%) guideline-diagnosed HF patients in the entire cohort of ESRD subjects. The native T1 value was elongated, and ECV was enlarged in the HF cohort relative to the non-HF cohort and normal controls (native T1, 1360.10 ± 50.14 ms, 1319.39 ± 55.44 ms and 1276.35 ± 56.56 ms; ECV, 35.42 ± 4.42%, 31.85 ± 3.01% and 26.97 ± 1.87%; all p<0.05). In the cardiac strain analysis, ECV was significantly correlated with global radial strain (GRS) (r = - 0.501, p = 0.009), global circumferential strain (GCS) (r = 0.553, p = 0.005) and global longitudinal strain (GLS) (r = 0.507, p = 0.008) in ESRD patients with HF. Cox proportional hazard regression models revealed that ECV (hazard ratio [HR] = 1.160, 95% confidence interval: 1.022 to 1.318, p = 0.022) was the only independent predictor of HF in ESRD patients. It also had a higher diagnostic accuracy for detecting MF (area under the curve [AUC] = 0.936; 95% confidence interval: 0.864 to 0.976) than native T1 and post T1 (all p ≤ 0.002). Kaplan-Meier analysis revealed that the high-ECV group had a shorter median overall survival time than the low-ECV group (18 months vs. 20 months, log-rank p = 0.046) and that ESRD patients with high ECV were more likely to have HF. CONCLUSIONS: Myocardial fibrosis quantification by ECV on CMR T1 mapping was shown to be an independent risk factor of heart failure, providing incremental prognostic value and risk stratification for cardiac events in ESRD patients. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR-DND-17012976, 13/12/2017, Retrospectively registered.


Subject(s)
Heart Failure/diagnostic imaging , Kidney Failure, Chronic/therapy , Magnetic Resonance Imaging, Cine , Myocardium/pathology , Renal Dialysis , Ventricular Remodeling , Adult , Aged , Case-Control Studies , Female , Fibrosis , Heart Failure/etiology , Heart Failure/pathology , Heart Failure/physiopathology , Humans , Kidney Failure, Chronic/complications , Kidney Failure, Chronic/diagnosis , Male , Middle Aged , Predictive Value of Tests , Prognosis , Prospective Studies , Renal Dialysis/adverse effects , Risk Assessment , Risk Factors
14.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 50(4): 571-576, 2019 Jul.
Article in Zh | MEDLINE | ID: mdl-31642238

ABSTRACT

OBJECTIVE: To determine the value of automated detection in computed tomography angiography (CTA) for cases with greater than 70% coronary stenosis. METHODS: Fifty-seven patients who had both coronary CTA and digital subtraction angiography (DSA) were retrospectively recruited in this study. The patients were categorized into two groups using a cutoff value of 70% stenosis in DSA. The AW4.6 software was used to estimate the diameter and square values from the data obtained from CTA. The sensitivity (SE), specificity (SPE), positive predictive value (PPV) and negative predictive value (NPV) of the automated CTA estimations were calculated. RESULTS: A total of 178 vessels from the 57 patients were analyzed. The automated CTA estimations had moderate to high levels of agreements (Kappa value: 0.716-0.804, P < 0.001) with the DSA diagnoses, compared with low to moderate levels of agreements (Kappa value: 0.385-0.533, P < 0.001) in manual interpretations. The square estimations generated high SE (100%) and NPV (100%) for patient diagnoses (P < 0.016 7 vs. manual interpretations). The diameter estimations generated high SPE (90.48%) and PPV (94.12%) for patient diagnoses (P < 0.016 7, vs. manual interpretations). Similarly, high SE (96.92%) and NPV (97.89%) were found for square estimations in vessel diagnoses, while high SPE (94.69%) and PPV (90.16%) were found for diameter estimations in vessel diagnoses. CONCLUSIONS: Both automated diameter and square algorithms have high accuracy for diagnosing patients with greater than 70% coronary artery stenosis. The AW4.6 can improve the detection of severe stenosis that needs stent interventions.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Coronary Stenosis/diagnostic imaging , Angiography, Digital Subtraction , Humans , Retrospective Studies , Sensitivity and Specificity
15.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 50(6): 878-883, 2019 Dec.
Article in Zh | MEDLINE | ID: mdl-31880121

ABSTRACT

ObstractPurpose "One-stop" CT myocardial perfusion imaging (CT-MPI) was compared with cardiac magnetic resonance(CMR) to investigate its application value in evaluating patients with severe coronary artery stenosis.MethodsFifty patients with coronary artery stenosis≥90% of at least one major coronary arteries comfirmed by coronary angiography (CAG) in the department of cardiology in our hospital, who referred for coronary artery stent implantation were prospectively enrolled. All the patients underwent "One-stop" CT-MPI within a week before surgery, among which 22 patients underwent CMR examination simultaneously. The postprocessing software Ziostation2 was used to obatin and compare the perfusion parameters of patients with normal and perfusion defect myocardium, including blood flow (BF), blood volume (BV), peak time (TTP), and mean transit time (MTT). Pearson correlation analysis was used to compare the correlation of relative perfusion parameters (defect/normal myocardium) between CT and CMR. Bland-Altman analysis was used to analyze the consistency between CT and CMR in left ventricular (LV) function parameters measurements.ResultsCompared with normal myocardium, BV and BF of perfusion defect myocardium were significantly decreased, while MTT and TTP were significantly prolonged (all P < 0.05). The rBV, rBF, rMTT and rTTP were medium to high positive correlated between CT and CMR (r=0.685, 0.641, 0.871, 0.733, respectively, all P < 0.05). Bland-Altman analysis showed that 95% (21/22) points were within the 95% limits of agreement (LoA), suggesting the LV function parameters measurements between two methods were highly consistent.Conclusion"One-stop" CT-MPI can simultaneously obtain the information about coronary anatomy, myocardial perfusion and LV function. It is of great value in the evaluation of patients with severe coronary artery stenosis, with shorter scan time and less contraindications compared with CMR.


Subject(s)
Coronary Artery Disease , Coronary Stenosis , Myocardial Perfusion Imaging , Coronary Angiography , Humans , Predictive Value of Tests , Tomography, X-Ray Computed
16.
J Magn Reson Imaging ; 47(5): 1406-1414, 2018 05.
Article in English | MEDLINE | ID: mdl-29044903

ABSTRACT

BACKGROUND: Both acute and chronic myocardial infarction (AMI and CMI, respectively) exhibit delayed enhancement; however, clinical decision-making processes frequently require the differentiation of these two types of myocardial injury. PURPOSE: To investigate the reliability of AMI and CMI characterization using native T1 mapping and its feasibility for discriminating AMI from CMI. STUDY TYPE: Case-control. ANIMAL MODEL: The study cohort comprised 12 AMI (mean post-MI, 3.75 ± 1.29 days) and 15 CMI (mean post-MI, 39.53 ± 6.10 days) Bama mini-pigs. FIELD STRENGTH/SEQUENCE: Balanced steady-state free precession (bSSFP), segmented-turbo-FLASH-PSIR, and modified Look-Locker inversion recovery (MOLLI) sequences at 3.0T. ASSESSMENT: The infarct sizes were compared on matching short-axis slices of late-gadolinium-enhanced (LGE) images and T1 maps by two experienced radiologists. STATISTICAL TESTS: The infarct sizes were compared on matching short-axis slices of LGE images and T1 maps, and agreement was determined using linear regression and Bland-Altman analyses. The native T1 values were compared between AMI and CMI models (independent sample t-test). The intraclass correlation coefficient was used to assess inter- and intraobserver variability. RESULTS: Measured infarct sizes did not differ between native T1 mapping and LGE images (AMI: P = 0.913; CMI: P = 0.233), and good agreement was observed between the two techniques (AMI: bias, -3.38 ± 19.38%; R2 = 0.96; CMI: bias, -10.55 ± 10.90%; R2 = 0.90). However, the native infarction myocardium T1 values and the T1 signal intensity ratio of infarct and remote myocardium (T1 SI ratio) did not differ significantly between AMI and CMI (P = 0.173). DATA CONCLUSION: Noncontrast native T1 mapping can accurately determine acute and chronic infarct areas as well as conventional LGE imaging; however, it cannot distinguish acute from chronic MI. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1406-1414.


Subject(s)
Magnetic Resonance Imaging , Myocardial Infarction/diagnostic imaging , Animals , Contrast Media , Decision Making , Decision Support Systems, Clinical , Disease Models, Animal , Gadolinium , Image Interpretation, Computer-Assisted/methods , Linear Models , Magnetic Resonance Imaging, Cine , Myocardium , Observer Variation , Radiology/methods , Regression Analysis , Reproducibility of Results , Swine , Swine, Miniature , Temperature
17.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 49(5): 749-753, 2018 Sep.
Article in Zh | MEDLINE | ID: mdl-30378338

ABSTRACT

OBJECTIVE: To determine consistencies between MR perfusion weighted imaging (PW-MRI) and CT perfusion imaging (CTP) in assessing hemodynamics of patients with moyamoya disease (MMD). METHODS: Images of PWI and CTP scan [including the map of cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), and mean transmit time (MTT)] of 24 MMD patients diagnosed by digital subtraction angiography(DSA) or time of flight-MR angiography (TOF-MRA) were obtained in the week before vascular reconstruction operations. Relative perfusion parameters (rCBF, rCBV, rMTT, rTTP) at the operative side within the middle cerebral artery territory and cerebellar hemisphere were compared with those of 17 patients without hypoperfusion and cerebrovascular disease using independent sample t test. Paired t test and Pearson correlation analyses were performed between the results of PWI-MRI and CTP. RESULTS: Different parameters were found in the MMD patients compared with the controls (P<0.05). The parameter results of PWI-MRI differed from those of CTP, but they were strongly correlated. CONCLUSION: Both PWI-MRI and CTP can detect the area and degree of hypoperfusion of MMD patients.


Subject(s)
Hemodynamics , Moyamoya Disease/diagnostic imaging , Perfusion Imaging , Case-Control Studies , Cerebrum/blood supply , Humans , Magnetic Resonance Angiography , Magnetic Resonance Imaging , Regional Blood Flow , Tomography, X-Ray Computed
18.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 49(2): 239-242, 2018 Mar.
Article in Zh | MEDLINE | ID: mdl-29737068

ABSTRACT

OBJECTIVE: To investigate the feasibility of low concentration contrast agent combined double low dose in CT pulmonary angiography. METHODS: 60 patients with clinically suspected pulmonary embolism examed by CT pulmonary angiography (CTPA) were divided into two groups (experimental group: n=30,80 kV, 15 mL,320 mg I/mL;control group: n=30,120 kV,50 mL,370 mg I/mL). The average CT value of main right and left pulmonary arteries,lobar arteries was calculated. Imaging post processing techniques included curved plannar reconstruction (CPR),volume rendering (VR) and maximal intensity projection (MIP). The artifact of the remaining contract in the superior vena cava and overall quality of the image were observed and analyzed by two senior doctors who were double blinded. RESULTS: All patients in two groups completed CTPA successfully. The image qualities of two groupssatisfy clinical diagnostic requirements and no difference of the image qualities was observed between two groups (P>0.05). The evaluation of venous pollution in experimental group was better than that of control group (P<0.01).No difference of CT values were observed between two groups [experimental group (423.2±89.4) HU,control group (465.7±85.6) HU](P>0.05). The SNR and CNR in experimental group were lower than those in control group (P<0.01 both).The CT dose index volume (CTDIvol),dose-length product (DLP) and size-specific dose estimates (SSDE) in experimental group were significantly lower than those incontrol group (P<0.01 all). CONCLUSION: The low concentration contrast agent combined double low dose in CT pulmonary angiography satisfies clinical diagnostic requirements. It has good clinical value for it could reduce venous pollution,iodine contrast agent and radiation exposure.


Subject(s)
Angiography , Contrast Media/administration & dosage , Pulmonary Embolism/diagnostic imaging , Humans , Radiographic Image Interpretation, Computer-Assisted , Tomography, X-Ray Computed
19.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 48(3): 471-475, 2017 May.
Article in Zh | MEDLINE | ID: mdl-28616928

ABSTRACT

OBJECTIVES: To explore the clinical value of readout-segmented echo planar imaging (Rs-EPI) sequence in the assessment of intracranial mass lesions compared to the standard single-shot EPI (Ss-EPI) sequence. METHODS: We included 21 patients with intracranial mass lesions who underwent both Ss-EPI diffusion weighted imaging (DWI) and Rs-EPI DWI at 3.0T MR scanner with a twenty-channel head-neck coil. The quality of images was assessed by two experienced radiologists independently. The differences in image quality between two sequences were analyzed using Wilcoxon signed-rank test. Inter-observer agreements were analyzed using interclass correlation coefficient (ICC) and Kappa test. RESULTS: All objectives were completed on 3.0T MR. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in Rs-EPI DWI were higher than those in Ss-EPI DWI (130.46±49.10 vs. 71.58±30.43, P=0.000; 33.22±18.86 vs. 17.92±18.72, P=0.003). The scores of overall image quality, ghost artifact where next to the paranasal sinuses, mastoid air cells and frontal sinus of Rs-EPI DWI were significantly higher than those of Ss-EPI DWI. Meanwhile, the geometric distortion of anatomical structures of Rs-EPI DWI were significantly lower compared to Ss-EPI DWI sequence (0.016±0.021 vs. 0.037±0.069, P=0.00). The inter-reader and intra-reader agreements for the assessment of qualitative parameters were good [0.74≤Kappa value or ICC≤0.92]. CONCLUSIONS: Rs-EPI DWI sequence is a potential technique to improve the imaging quality in the diagnosis of intracranial mass lesions.


Subject(s)
Brain/diagnostic imaging , Brain/pathology , Diffusion Magnetic Resonance Imaging , Echo-Planar Imaging , Artifacts , Humans , Reproducibility of Results , Signal-To-Noise Ratio
20.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 47(6): 945-948, 2016 Nov.
Article in Zh | MEDLINE | ID: mdl-28598130

ABSTRACT

OBJECTIVES: To investigate the radiation dose of body surface at sensitive organs using different protective precaution in head CT scanning. METHODS: The standard phantom received head routine sequence scanning with dual-source computed tomography.The phantoms were scanned with three different protective precaution:group A (without protective clothing),group B (wearing lead collar and cover lead clothes),group C (wearing lead collar and clothes without cuffs).The thermoluminescence dosimeters (TLD) was placed on the body surface corresponding to sensitive organs to measure radiation dose. RESULTS: The volume of CT dose index (CTDIvol) and dose length product (DLP) in group A,B and C were same,44.06 mGy and 634 mGy×cm,respectively.There was no statistic significant difference between group A,B and C of radiation dose in non-protective region (P=0.712).The radiation dose in the neck region under the cover of lead collar in group A,B and C were (2.57 ± 0.65) mGy,(2.30 ± 1.10) mGy and (2.48 ± 0.90) mGy,respectively,without statistic significant difference between groups (P=0.816).However,the radiation dose in abdominal region of group A was (0.66±0.37) mGy,which was significantly higher than that of group B [(0.18 ± 0.18) mGy] and group C [(0.18±0.16) mGy],The radiation dose in dorsal region of group A was (0.55±0.43) mGy,which was significantly higher than that of group B [(0.28±0.22) mGy],while that of group C [(0.14±0.12) mGy] was significantly lower than group B. CONCLUSIONS: Compared to traditional lead coverage,lead collar and cloth can decrease the radiation dose of body surface and sensitive organs in head scan with dual source CT.


Subject(s)
Head/radiation effects , Radiation Dosage , Tomography, X-Ray Computed , Humans , Phantoms, Imaging , Protective Clothing
SELECTION OF CITATIONS
SEARCH DETAIL