Water Sci Technol ; 69(2): 335-42, 2014.
Article in English | MEDLINE | ID: mdl-24473303

ABSTRACT

This paper describes the results of the first full-scale implementation of a two-stage vertical flow constructed wetland (CW) system developed to increase nitrogen removal. The full-scale system was constructed for the Bärenkogelhaus, which is located in Styria at the top of a mountain, 1,168 m above sea level. The Bärenkogelhaus has a restaurant with 70 seats, 16 rooms for overnight guests and is a popular site for day visits, especially during weekends and public holidays. The CW treatment system was designed for a hydraulic load of 2,500 L.d(-1) with a specific surface area requirement of 2.7 m(2) per person equivalent (PE). It was built in fall 2009 and started operation in April 2010 when the restaurant was re-opened. Samples were taken between July 2010 and June 2013 and were analysed in the laboratory of the Institute of Sanitary Engineering at BOKU University using standard methods. During 2010 the restaurant at Bärenkogelhaus was open 5 days a week whereas from 2011 the Bärenkogelhaus was open only on demand for events. This resulted in decreased organic loads of the system in the later period. In general, the measured effluent concentrations were low and the removal efficiencies high. During the whole period the ammonia nitrogen effluent concentration was below 1 mg/L even at effluent water temperatures below 3 °C. Investigations during high-load periods, i.e. events like weddings and festivals at weekends, with more than 100 visitors, showed a very robust treatment performance of the two-stage CW system. Effluent concentrations of chemical oxygen demand and NH4-N were not affected by these events with high hydraulic loads.


Subject(s)
Waste Disposal, Fluid/methods , Wetlands
2.
Water Sci Technol ; 64(5): 1122-9, 2011.
Article in English | MEDLINE | ID: mdl-22214060

ABSTRACT

In this paper the nitrogen elimination rates of different constructed wetland (CW) designs reported in literature are compared with those obtained for outdoor and indoor 2-stage vertical flow (VF) systems. The outdoor system is located about 150 km west of Vienna. Both stages are planted with Phragmites australis and the system has been operated for 4 years continuously. During this period the average value of the nitrogen elimination rate was 3.30 g N m(-2) d(-1). The indoor system comprises three parallel operated 2-stage VF systems and is located in the technical lab hall at BOKU University. The design of the indoor system resembles the outdoor system. However, there are a few differences: (1) the indoor systems are not planted, and (2) different filter media have been used for the main layer of the first stages. With the indoor system the highest nitrogen elimination rate achieved was 2.24 g N m(-2) d(-1) for the system with zeolite and impounded drainage layer. Similar results have been found in France for treating raw wastewater with VF and horizontal flow (HF) beds in series with nitrogen elimination rates of 1.89 and 2.82 g N m(-2) d(-1) for differently designed HF beds. The highest nitrogen elimination rates of 15.9 g N m(-2) d(-1) reported were for pilot-scale VF CWs treating high-strength synthetic wastewater (total nitrogen of 305 mg L(-1) in the influent) in Thailand. It has been shown that the outdoor two-stage VF CW system has one of the highest nitrogen elimination rates of CWs treating domestic wastewater.


Subject(s)
Nitrogen/isolation & purification , Wetlands , Waste Disposal, Fluid/methods , Water Purification/methods
3.
Water Sci Technol ; 64(5): 1137-41, 2011.
Article in English | MEDLINE | ID: mdl-22214062

ABSTRACT

In the first two years of operation a nitrogen removal efficiency of 53% and a high average elimination rate of 1,000 g N m(-2) yr(-1) could be observed for a two-stage vertical flow (VF) constructed wetland (CW) system. The two-stage system consists of two VF beds with intermittent loading operated in series, each stage having a surface area of 10 m2. The first stage uses sand with a grain size of 2-3.2 mm for the 50 cm main layer and has a drainage layer that is impounded; the second stage sand with a grain size of 0.06-4 mm and a conventional drainage layer (with free drainage). The two-stage VF system was designed for and operated with an organic load of 40 g COD m(-2) d(-1) (i.e. 2 m2 per person equivalent). Data from the following years of operation showed that from the third year nitrogen elimination increased and stabilized. The median values of the nitrogen elimination rate in the first five years of operation have been 3.51, 2.76, 4.20, 3.84 and 4.07 g N m(-2) d(-1), the median value of the last three years being 3.8 g N m(-2) d(-1) and 1,380 g N m(-2) yr(-1), respectively, and the nitrogen removal > 60%. It can be assumed that the vegetation as well as the biofilm development in the two-stage VF CW system plays the major role for the enhancement of the nitrogen elimination rate.


Subject(s)
Nitrogen/isolation & purification , Waste Disposal, Fluid/methods
4.
Water Sci Technol ; 61(5): 1341-8, 2010.
Article in English | MEDLINE | ID: mdl-20220255

ABSTRACT

Constructed wetlands (CWs) are known to be robust wastewater treatment systems and are therefore very suitable for small villages and single households. When nitrification is required, vertical flow (VF) CWs are widely used. This contribution compares the behaviour and treatment efficiencies of a single-stage VF CW and a two-stage VF CW system under varying operating and loading conditions according to standardized testing procedures for small wastewater treatment plants as described in the European standard EN 12566-3. The single-stage VF CW is designed and operated according to the Austrian design standards with an organic load of 20 g COD m(-2) d(-1) (i.e. 4 m(2) per person equivalent (PE)) The two-stage VF CW system is operated with 40 g COD m(-2) d(-1) (i.e. 2 m(2) per PE). During the 48 week testing period the Austrian threshold effluent concentrations have not been exceeded in either system. The two-stage VF CW system showed to be more robust as compared to the single-stage VF CW especially during highly fluctuating loads at low temperatures.


Subject(s)
Waste Disposal, Fluid/methods , Water Purification/methods , Wetlands , Biodegradation, Environmental , Electric Power Supplies , Equipment Design , Nitrogen/chemistry , Seasons , Temperature , Time Factors , Water Movements , Water Pollutants, Chemical/chemistry
5.
Water Sci Technol ; 59(6): 1111-6, 2009.
Article in English | MEDLINE | ID: mdl-19342806

ABSTRACT

In a first phase of this study it was shown that the Austrian effluent standards for organic matter could not be met in winter for vertical flow (VF) beds designed for and loaded with 27 g COD.m(-2).d(-1) (3 m2 per person equivalent). The aim of this second phase of the study was to investigate, if the performance of a constructed wetland can be enhanced, i.e. if the effluent requirements can be met, when an additional gravel layer (15 cm, 4-8 mm) is added on top of the main layer of the VF bed. The hypothesis was that this top layer would increase the thermal insulation and consequently the temperatures in the filter bed during cold periods, thus resulting in higher removal efficiencies during winter. Two VF beds were operated in parallel; one bed with such a 15 cm top layer, one without. Otherwise the construction of both beds was identical: surface area of about 20 m2, 50 cm main layer (grain size 0.06-4 mm, d10=0.2 mm; d60=0.8 mm), planted with common reed (Phragmites australis). The beds were intermittently loaded 4 times per day with mechanically pre-treated wastewater (hydraulic loading: 47 mm.d(-1); median value of the influent concentration: 505 mg COD.L(-1)). Despite a better performance during the first winter, the bed with additional top layer showed in general a very unstable performance. It is assumed that the main reason for this was that the oxygen transfer was reduced by the additional top layer so far that suspended organic matter could not any longer be degraded in between loadings. Therefore clogging of the filter occurred.


Subject(s)
Cold Temperature , Wetlands
6.
Water Sci Technol ; 57(12): 1881-7, 2008.
Article in English | MEDLINE | ID: mdl-18587174

ABSTRACT

By using a two-stage constructed wetland (CW) system operated with an organic load of 40 gCOD.m(-2).d(-1) (2 m2 per person equivalent) average nitrogen removal efficiencies of about 50% and average nitrogen elimination rates of 980 g N.m(-2).yr(-1) could be achieved. Two vertical flow beds with intermittent loading have been operated in series. The first stage uses sand with a grain size of 2-3.2 mm for the main layer and has a drainage layer that is impounded; the second stage sand with a grain size of 0.06-4 mm and a drainage layer with free drainage. The high nitrogen removal can be achieved without recirculation thus it is possible to operate the two-stage CW system without energy input. The paper shows performance data for the two-stage CW system regarding removal of organic matter and nitrogen for the two year operating period of the system. Additionally, its efficiency is compared with the efficiency of a single-stage vertical flow CW system designed and operated according to the Austrian design standards with 4 m2 per person equivalent. The comparison shows that a higher effluent quality could be reached with the two-stage system although the two-stage CW system is operated with the double organic load or half the specific surface area requirement, respectively. Another advantage is that the specific investment costs of the two-stage CW system amount to 1,200 EUR per person (without mechanical pre-treatment) and are only about 60% of the specific investment costs of the singe-stage CW system.


Subject(s)
Nitrogen/isolation & purification , Water Purification/methods , Wetlands
7.
Water Air Soil Pollut ; 228(2): 82, 2017.
Article in English | MEDLINE | ID: mdl-28955108

ABSTRACT

The cost effective maintenance of underwater pressure pipes for sewage disposal in Austria requires the detection and localization of leakages. Extrusion of wastewater in lakes can heavily influence the water and bathing quality of surrounding waters. The Distributed Temperature Sensing (DTS) technology is a widely used technique for oil and gas pipeline leakage detection. While in pipeline leakage detection, fiber optic cables are installed permanently at the outside or within the protective sheathing of the pipe; this paper aims at testing the feasibility of detecting leakages with temporary introduced fiber optic cable inside the pipe. The detection and localization were tested in a laboratory experiment. The intrusion of water from leakages into the pipe, producing a local temperature drop, served as indicator for leakages. Measurements were taken under varying measurement conditions, including the number of leakages as well as the positioning of the fiber optic cable. Experiments showed that leakages could be detected accurately with the proposed methodology, when measuring resolution, temperature gradient and measurement time were properly selected. Despite the successful application of DTS for leakage detection in this lab environment, challenges in real system applications may arise from temperature gradients within the pipe system over longer distances and the placement of the cable into the real pipe system.