1.
Pol J Radiol ; 89: e196-e203, 2024.
Article in English | MEDLINE | ID: mdl-38783912

ABSTRACT

Purpose: The primary objective of this study was to evaluate the discriminatory utility of magnetic resonance imaging (MRI), 18F-fluciclovine positron emission tomography (PET), maximum standardized uptake value (SUVmax), prostate-specific antigen (PSA), and combinations of these diagnostic modalities for detecting local prostate cancer recurrence in the setting of rising PSA after radical prostatectomy. Material and methods: Patients were characterised for clinical features such as Gleason score, PSA at surgery, PSA at follow-up, follow-up MRI result, follow-up PET result, follow-up SUVmax, and follow-up disease status. The utility of diagnostic parameters for detecting disease recurrence at the prostatectomy bed was assessed using receiver operating characteristics (ROC) analysis to determine the area under the curve (AUC) for each model. Sensitivity, specificity, and positive/negative predictive values were also calculated. Optimal cut-off points for continuous variables were determined based on maximum Youden's J statistics. Results: The study found that MRI had the highest concordance (96%), sensitivity (100%), specificity (91%), positive predictive value (93%), and negative predictive value (100%) among the diagnostic modalities. The AUC for MRI was 0.9545, indicating a high discriminatory ability for detecting prostate cancer local recurrence. When combined, PET and SUVmax (cut-off value of 2.85) showed an improved performance compared to using them individually, with an AUC of 0.8925. Conclusions: The analysis suggests that MRI is the most effective imaging modality for detecting local prostate cancer recurrence, with 18F-fluciclovine PET and SUVmax also showing promising combined results. PSA has moderate discriminatory utility at follow-up but can still provide valuable information in detecting prostate cancer recurrence. Further research and recent references are needed to support these findings.

2.
J Nucl Med ; 65(8): 1239-1243, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38871390

ABSTRACT

Interreader and intrareader reproducibility of 18F-flotufolastat PET/CT scans in newly diagnosed and recurrent prostate cancer patients was assessed from masked image evaluations from two phase 3 studies. Methods: 18F-flotufolastat PET/CT images of newly diagnosed (n = 352) or recurrent (n = 389) patients were evaluated by 3 masked readers. Cohen κ was used to assess pairwise patient- and region-level interreader agreement. Agreement among all readers was assessed using Fleiss κ. Intrareader agreement between the first and repeat read (20% of images, ≥4 wk later) was assessed using Cohen κ. Results: Pairwise interreader agreement was 95% or better (newly diagnosed) and 75% or better (recurrent). The κ coefficients were impacted by the high-agreement-low-κ paradox: Cohen κ ranged from not estimable to 0.55, whereas Fleiss κ was 0.50 (newly diagnosed) and 0.41 (recurrent). Agreement was highest in the prostate of newly diagnosed patients (≥95%) and in the pelvic lymph nodes in recurrent patients (≥87%). Intrareader agreement was 86% or better across both populations. Conclusion: 18F-flotufolastat PET/CT images can be reliably interpreted, with a high degree of inter- and intrareader agreement.


Subject(s)
Observer Variation , Positron Emission Tomography Computed Tomography , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Reproducibility of Results , Prospective Studies , Aged , Image Interpretation, Computer-Assisted/methods , Middle Aged , Neoplasm Recurrence, Local/diagnostic imaging , Recurrence