Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Affiliation country
Publication year range
1.
Front Cell Neurosci ; 17: 1276506, 2023.
Article in English | MEDLINE | ID: mdl-38188669

ABSTRACT

Accaumulating studies focus on the effects of C3-positive A1-like phenotypes and S100A10-positive A2-like phenotypes of reactive astrocytes on spinal cord injury (SCI), however the origins and dynamic changes of C3- and S100A10-positive reactive astrocytes after SCI remain poorly understood. Through transgenic mice and lineage tracing, we aimed to determine the origins of C3- and S100A10-positive reactive astrocytes. Meanwhile, the distribution and dynamic changes in C3- and S100A10-positive reactive astrocytes were also detected in juvenile and adult SCI mice models and cultured astrocytes. Combing with bulk RNA sequencing (RNA-seq), single-cell RNA sequencing (scRNA-seq) and bioinformatic analysis, we further explored the dynamic transcripts changes of C3- and S100A10-positive reactive astrocytes after SCI. We confirmed that resident astrocytes produced both C3- and S100A10-positive reactive astrocytes, whereas ependymal cells regenerated only S100A10-positive reactive astrocytes in lesion area. Importantly, C3-positive reactive astrocytes were predominantly activated in adult SCI mice, while S100A10-positive reactive astrocytes were hyperactivated in juvenile mice. Furthermore, we observed that C3- and S100A10-positive reactive astrocytes had a dynamic transformation process at different time in vitro and vivo, and a majority of intermediate states of C3- and S100A10-positive reactive astrocytes were found during transformation. RNA-seq and scRNA-seq results further confirmed that the transcripts of C3-positive reactive astrocytes and their lipid toxicity were gradually increased with time and age. In contrast, S100A10-positive reactive astrocytes transcripts increased at early time and then gradually decreased after SCI. Our results provide insight into the origins and dynamic changes of C3- and S100A10-positive reactive astrocytes after SCI, which would be valuable resources to further target C3- and S100A10-positive reactive astrocytes after SCI.

2.
PLoS One ; 9(1): e85298, 2014.
Article in English | MEDLINE | ID: mdl-24454839

ABSTRACT

PURPOSE: There is still some controversy regarding the optimal biomechanical concept for spinopelvic stabilization following total sacrectomy for malignancy. Strains at specific anatomical sites at pelvis/sacrum and implants interfaces have been poorly investigated. Herein, we compared and analyzed the strains applied at key points at the bone-implant interface in four different spinopelvic constructs following total sacrectomy; consequently, we defined a balanced architecture for spinopelvic fusion in that situation. METHODS: Six human cadaveric specimens, from second lumbar vertebra to proximal femur, were used to compare the partial strains at specific sites in a total sacrectomy model. Test constructs included: (1) intact pelvis (control), (2) sacral-rod reconstruction (SRR), (3) bilateral fibular flap reconstruction (BFFR), (4) four-rods reconstruction (FRR), and (5) improved compound reconstruction (ICR). Strains were measured by bonded strain gauges onto the surface of three specific sites (pubic rami, arcuate lines, and posterior spinal rods) under a 500 N axial load. RESULTS: ICR caused lower strains at specific sites and, moreover, on stress distribution and symmetry, compared to the other three constructs. Strains at pubic rami and arcuate lines following BFFR were lower than those following SRR, but higher at the posterior spinal rod construct. The different modes of strain distribution reflected different patient's parameter-related conditions. FRR model showed the highest strains at all sites because of the lack of an anterior bracing frame. CONCLUSIONS: The findings of this investigation suggest that both anterior bracing frame and the four-rods load dispersion provide significant load sharing. Additionally, these two constructs decrease the peak strains at bone-implant interface, thus determining the theoretical surgical technique to achieve optimal stress dispersion and balance for spinopelvic reconstruction in early postoperative period following total sacrectomy.


Subject(s)
Pelvic Bones/surgery , Plastic Surgery Procedures/adverse effects , Prostheses and Implants , Sacrum/surgery , Spinal Fusion/adverse effects , Stress, Mechanical , Adult , Aged , Female , Humans , Male , Materials Testing , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL