Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
1.
MAGMA ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38822992

ABSTRACT

OBJECTIVES: To assess the feasibility of sodium-23 MRI for performing quantitative and non-invasive measurements of total sodium concentration (TSC) and relaxation in a variety of abdominal organs. MATERIALS AND METHODS: Proton and sodium imaging of the abdomen was performed in 19 healthy volunteers using a 3D cones sequence and a sodium-tuned 4-rung transmit/receive body coil on a clinical 3 T system. The effects of B1 non-uniformity on TSC measurements were corrected using the double-angle method. The long-component of 23Na T2* relaxation time was measured using a series of variable echo-times. RESULTS: The mean and standard deviation of TSC and long-component 23Na T2* values were calculated across the healthy volunteer group in the kidneys, cerebrospinal fluid (CSF), liver, gallbladder, spleen, aorta, and inferior vena cava. DISCUSSION: Mean TSC values in the kidneys, liver, and spleen were similar to those reported using 23Na-MRI previously in the literature. Measurements in the CSF and gallbladder were lower, potentially due to the reduced spatial resolution achievable in a clinically acceptable scan time. Mean long-component 23Na T2* values were consistent with previous reports from the kidneys and CSF. Intra-population standard error was larger in smaller, fluid-filled structures due to fluid motion and partial volume effects.

2.
BMC Psychiatry ; 23(1): 791, 2023 10 30.
Article in English | MEDLINE | ID: mdl-37904091

ABSTRACT

BACKGROUND: Noninvasive neurostimulation treatments are increasingly being used to treat major depression, which is a common cause of disability worldwide. While electroconvulsive therapy (ECT) and transcranial magnetic stimulation (TMS) are both effective in treating depressive episodes, their mechanisms of action are, however, not completely understood. ECT is given under general anesthesia, where an electrical pulse is administered through electrodes placed on the patient's head to trigger a seizure. ECT is used for the most severe cases of depression and is usually not prescribed before other options have failed. With TMS, brain stimulation is achieved through rapidly changing magnetic fields that induce electric currents underneath a ferromagnetic coil. Its efficacy in depressive episodes has been well documented. This project aims to identify the neurobiological underpinnings of both the effects and side effects of the neurostimulation techniques ECT and TMS. METHODS: The study will utilize a pre-post case control longitudinal design. The sample will consist of 150 subjects: 100 patients (bipolar and major depressive disorder) who are treated with either ECT (N = 50) or TMS (N = 50) and matched healthy controls (N = 50) not receiving any treatment. All participants will undergo multimodal magnetic resonance imaging (MRI) as well as neuropsychological and clinical assessments at multiple time points before, during and after treatment. Arterial spin labeling MRI at baseline will be used to test whether brain perfusion can predict outcomes. Signs of brain disruption, potentiation and rewiring will be explored with resting-state functional MRI, magnetic resonance spectroscopy and multishell diffusion weighted imaging (DWI). Clinical outcome will be measured by clinician assessed and patient reported outcome measures. Memory-related side effects will be investigated, and specific tests of spatial navigation to test hippocampal function will be administered both before and after treatment. Blood samples will be stored in a biobank for future analyses. The observation time is 6 months. Data will be explored in light of the recently proposed disrupt, potentiate and rewire (DPR) hypothesis. DISCUSSION: The study will contribute data and novel analyses important for our understanding of neurostimulation as well as for the development of enhanced and more personalized treatment. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05135897.


Subject(s)
Bipolar Disorder , Depressive Disorder, Major , Electroconvulsive Therapy , Transcranial Magnetic Stimulation , Humans , Depressive Disorder, Major/diagnostic imaging , Depressive Disorder, Major/therapy , Electroconvulsive Therapy/adverse effects , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy , Transcranial Magnetic Stimulation/adverse effects , Treatment Outcome , Bipolar Disorder/diagnostic imaging , Bipolar Disorder/therapy
3.
Proc Natl Acad Sci U S A ; 117(4): 2092-2098, 2020 01 28.
Article in English | MEDLINE | ID: mdl-31964840

ABSTRACT

Our purpose is to investigate the feasibility of imaging tumor metabolism in breast cancer patients using 13C magnetic resonance spectroscopic imaging (MRSI) of hyperpolarized 13C label exchange between injected [1-13C]pyruvate and the endogenous tumor lactate pool. Treatment-naïve breast cancer patients were recruited: four triple-negative grade 3 cancers; two invasive ductal carcinomas that were estrogen and progesterone receptor-positive (ER/PR+) and HER2/neu-negative (HER2-), one grade 2 and one grade 3; and one grade 2 ER/PR+ HER2- invasive lobular carcinoma (ILC). Dynamic 13C MRSI was performed following injection of hyperpolarized [1-13C]pyruvate. Expression of lactate dehydrogenase A (LDHA), which catalyzes 13C label exchange between pyruvate and lactate, hypoxia-inducible factor-1 (HIF1α), and the monocarboxylate transporters MCT1 and MCT4 were quantified using immunohistochemistry and RNA sequencing. We have demonstrated the feasibility and safety of hyperpolarized 13C MRI in early breast cancer. Both intertumoral and intratumoral heterogeneity of the hyperpolarized pyruvate and lactate signals were observed. The lactate-to-pyruvate signal ratio (LAC/PYR) ranged from 0.021 to 0.473 across the tumor subtypes (mean ± SD: 0.145 ± 0.164), and a lactate signal was observed in all of the grade 3 tumors. The LAC/PYR was significantly correlated with tumor volume (R = 0.903, P = 0.005) and MCT 1 (R = 0.85, P = 0.032) and HIF1α expression (R = 0.83, P = 0.043). Imaging of hyperpolarized [1-13C]pyruvate metabolism in breast cancer is feasible and demonstrated significant intertumoral and intratumoral metabolic heterogeneity, where lactate labeling correlated with MCT1 expression and hypoxia.


Subject(s)
Breast Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Breast Neoplasms/genetics , Breast Neoplasms/metabolism , Breast Neoplasms/pathology , Carbon Isotopes/chemistry , Carbon Isotopes/metabolism , Female , Humans , Hypoxia-Inducible Factor 1, alpha Subunit/genetics , Hypoxia-Inducible Factor 1, alpha Subunit/metabolism , L-Lactate Dehydrogenase/genetics , L-Lactate Dehydrogenase/metabolism , Magnetic Resonance Imaging/instrumentation , Monocarboxylic Acid Transporters/genetics , Monocarboxylic Acid Transporters/metabolism , Muscle Proteins/genetics , Muscle Proteins/metabolism , Pyruvic Acid/chemistry , Pyruvic Acid/metabolism , Symporters/genetics , Symporters/metabolism
4.
Br J Cancer ; 127(2): 337-349, 2022 07.
Article in English | MEDLINE | ID: mdl-35462561

ABSTRACT

BACKGROUND: Breast cancer remains a leading cause of death in women and novel imaging biomarkers are urgently required. Here, we demonstrate the diagnostic and treatment-monitoring potential of non-invasive sodium (23Na) MRI in preclinical models of breast cancer. METHODS: Female Rag2-/- Il2rg-/- and Balb/c mice bearing orthotopic breast tumours (MDA-MB-231, EMT6 and 4T1) underwent MRI as part of a randomised, controlled, interventional study. Tumour biology was probed using ex vivo fluorescence microscopy and electrophysiology. RESULTS: 23Na MRI revealed elevated sodium concentration ([Na+]) in tumours vs non-tumour regions. Complementary proton-based diffusion-weighted imaging (DWI) linked elevated tumour [Na+] to increased cellularity. Combining 23Na MRI and DWI measurements enabled superior classification accuracy of tumour vs non-tumour regions compared with either parameter alone. Ex vivo assessment of isolated tumour slices confirmed elevated intracellular [Na+] ([Na+]i); extracellular [Na+] ([Na+]e) remained unchanged. Treatment with specific inward Na+ conductance inhibitors (cariporide, eslicarbazepine acetate) did not affect tumour [Na+]. Nonetheless, effective treatment with docetaxel reduced tumour [Na+], whereas DWI measures were unchanged. CONCLUSIONS: Orthotopic breast cancer models exhibit elevated tumour [Na+] that is driven by aberrantly elevated [Na+]i. Moreover, 23Na MRI enhances the diagnostic capability of DWI and represents a novel, non-invasive biomarker of treatment response with superior sensitivity compared to DWI alone.


Subject(s)
Breast Neoplasms , Sodium , Animals , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Contrast Media , Diffusion Magnetic Resonance Imaging/methods , Female , Humans , Magnetic Resonance Imaging/methods , Mice
5.
Magn Reson Med ; 86(3): 1734-1745, 2021 09.
Article in English | MEDLINE | ID: mdl-33934383

ABSTRACT

PURPOSE: An unmet need in carbon-13 (13 C)-MRI is a transmit system that provides uniform excitation across a large FOV and can accommodate patients of wide-ranging body habitus. Due to the small difference between the resonant frequencies, sodium-23 (23 Na) coil developments can inform 13 C coil design while being simpler to assess due to the higher naturally abundant 23 Na signal. Here we present a removable 23 Na birdcage, which also allows operation as a 13 C abdominal coil. METHODS: We demonstrate a quadrature-driven 4-rung 23 Na birdcage coil of 50 cm in length for both 23 Na and 13 C abdominal imaging. The coil transmit efficiencies and B1+ maps were compared to a linearly driven 13 C Helmholtz-based (clamshell) coil. SNR was investigated with 23 Na and 13 C data using an 8-channel 13 C receive array within the 23 Na birdcage. RESULTS: The 23 Na birdcage longitudinal FOV was > 40 cm, whereas the 13 C clamshell was < 32 cm. The transmit efficiency of the birdcage at the 23 Na frequency was 0.65 µT/sqrt(W), similar to the clamshell for 13 C. However, the coefficient of variation of 23 Na- B1+ was 16%, nearly half that with the 13 C clamshell. The 8-channel 13 C receive array combined with the 23 Na birdcage coil generated a greater than twofold increase in 23 Na-SNR from the central abdomen compared with the birdcage alone. DISCUSSION: This 23 Na birdcage coil has a larger FOV and improved B1+ uniformity when compared to the widely used clamshell coil design while also providing similar transmit efficiency. The coil has the potential to be used for both 23 Na and 13 C imaging.


Subject(s)
Magnetic Resonance Imaging , Sodium , Abdomen , Equipment Design , Humans , Phantoms, Imaging
6.
Magn Reson Med ; 85(5): 2370-2376, 2021 05.
Article in English | MEDLINE | ID: mdl-33274790

ABSTRACT

PURPOSE: The aim of the study was to investigate whether incorrectly compensated eddy currents are the source of persistent X-nuclear spectroscopy and imaging artifacts, as well as methods to correct this. METHODS: Pulse-acquire spectra were collected for 1 H and X-nuclei (23 Na or 31 P) using the minimum TR permitted on a 3T clinical MRI system. Data were collected in 3 orientations (axial, sagittal, and coronal) with the spoiler gradient at the end of the TR applied along the slice direction for each. Modifications to system calibration files to tailor eddy current compensation for each X-nucleus were developed and applied, and data were compared with and without these corrections for: slice-selective MRS (for 23 Na and 31 P), 2D spiral trajectories (for 13 C), and 3D cones trajectories (for 23 Na). RESULTS: Line-shape distortions characteristic of eddy currents were demonstrated for X-nuclei, which were not seen for 1 H. The severity of these correlated with the amplitude of the eddy current frequency compensation term applied by the system along the axis of the applied spoiler gradient. A proposed correction to eddy current compensation, taking account of the gyromagnetic ratio, was shown to dramatically reduce these distortions. The same correction was also shown to improve data quality of non-Cartesian imaging (2D spiral and 3D cones trajectories). CONCLUSION: A simple adaptation of the default compensation for eddy currents was shown to eliminate a range of artifacts detected on X-nuclear spectroscopy and imaging.


Subject(s)
Artifacts , Magnetic Resonance Imaging , Algorithms , Brain , Calibration , Phantoms, Imaging
7.
Kidney Int ; 98(5): 1174-1178, 2020 11.
Article in English | MEDLINE | ID: mdl-32585166

ABSTRACT

Sodium magnetic resonance imaging (MRI) is a powerful, non-invasive technique to assess sodium distribution within the kidney. Here we undertook pre-clinical and clinical studies to quantify the corticomedullary sodium gradient in healthy individuals and in a porcine model of diuresis. The results demonstrated that sodium MRI could detect spatial differences in sodium biodistribution across the kidney. The sodium gradient of the kidney changed significantly after diuresis in the pig model and was independent of blood electrolyte measurements. Thus, rapid sodium MRI can be used to dynamically quantify sodium biodistribution in the porcine and human kidney.


Subject(s)
Kidney , Sodium , Animals , Diuresis , Kidney/diagnostic imaging , Kidney/metabolism , Magnetic Resonance Imaging , Sodium/metabolism , Swine , Tissue Distribution
8.
Magn Reson Med ; 84(4): 1817-1827, 2020 10.
Article in English | MEDLINE | ID: mdl-32167199

ABSTRACT

PURPOSE: Calibration of hyperpolarized 13 C-MRI is limited by the low signal from endogenous carbon-containing molecules and consequently requires 13 C-enriched external phantoms. This study investigated the feasibility of using either 23 Na-MRI or 1 H-MRI to calibrate the 13 C excitation. METHODS: Commercial 13 C-coils were used to estimate the transmit gain and center frequency for 13 C and 23 Na resonances. Simulations of the transmit B1 profile of a Helmholtz loop were performed. Noise correlation was measured for both nuclei. A retrospective analysis of human data assessing the use of the 1 H resonance to predict [1-13 C]pyruvate center frequency was also performed. In vivo experiments were undertaken in the lower limbs of 6 pigs following injection of hyperpolarized 13 C-pyruvate. RESULTS: The difference in center frequencies and transmit gain between tissue 23 Na and [1-13 C]pyruvate was reproducible, with a mean scale factor of 1.05179 ± 0.00001 and 10.4 ± 0.2 dB, respectively. Utilizing the 1 H water peak, it was possible to retrospectively predict the 13 C-pyruvate center frequency with a standard deviation of only 11 Hz sufficient for spectral-spatial excitation-based studies. CONCLUSION: We demonstrate the feasibility of using the 23 Na and 1 H resonances to calibrate the 13 C transmit B1 using commercially available 13 C-coils. The method provides a simple approach for in vivo calibration and could improve clinical workflow.


Subject(s)
Protons , Sodium , Animals , Carbon Isotopes , Magnetic Resonance Imaging , Phantoms, Imaging , Pyruvic Acid , Retrospective Studies , Swine
9.
J Magn Reson Imaging ; 51(1): 90-97, 2020 01.
Article in English | MEDLINE | ID: mdl-31081564

ABSTRACT

BACKGROUND: There has been recent interest in nonproton MRI including hyperpolarized carbon-13 (13 C) imaging. Prostate cancer has been shown to have a higher tissue sodium concentration (TSC) than normal tissue. Sodium (23 Na) and 13 C nuclei have a frequency difference of only 1.66 MHz at 3T, potentially enabling 23 Na imaging with a 13 C-tuned coil and maximizing the metabolic information obtained from a single study. PURPOSE: To compare TSC measurements from a 13 C-tuned endorectal coil to those quantified with a dedicated 23 Na-tuned coil. STUDY TYPE: Prospective. POPULATION: Eight patients with biopsy-proven, intermediate/high risk prostate cancer imaged prior to prostatectomy. SEQUENCE: 3T MRI with separate dual-tuned 1 H/23 Na and 1 H/13 C endorectal receive coils to quantify TSC. ASSESSMENT: Regions-of-interest for TSC quantification were defined for normal peripheral zone (PZ), normal transition zone (TZ), and tumor, with reference to histopathology maps. STATISTICAL TESTS: Two-sided Wilcoxon rank sum with additional measures of correlation, coefficient of variation, and Bland-Altman plots to assess for between-test differences. RESULTS: Mean TSC for normal PZ and TZ were 39.2 and 33.9 mM, respectively, with the 23 Na coil and 40.1 and 36.3 mM, respectively, with the 13 C coil (P = 0.22 and P = 0.11 for the intercoil comparison, respectively). For tumor tissue, there was no statistical difference between the overall mean tumor TSC measured with the 23 Na coil (41.8 mM) and with the 13 C coil (46.6 mM; P = 0.38). Bland-Altman plots showed good repeatability for tumor TSC measurements between coils, with a reproducibility coefficient of 9 mM; the coefficient of variation between the coils was 12%. The Pearson correlation coefficient for TSC between coils for all measurements was r = 0.71 (r2 = 0.51), indicating a strong positive linear relationship. The mean TSC within PZ tumors was significantly higher compared with normal PZ for both the 23 Na coil (45.4 mM; P = 0.02) and the 13 C coil (49.4 mM; P = 0.002). DATA CONCLUSION: We demonstrated the feasibility of using a carbon-tuned coil to quantify TSC, enabling dual metabolic information from a single coil. This approach could make the acquisition of both 23 Na-MRI and 13 C-MRI feasible in a single clinical imaging session. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:90-97.


Subject(s)
Carbon Isotopes , Magnetic Resonance Imaging/methods , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/metabolism , Sodium Isotopes , Sodium/metabolism , Aged , Feasibility Studies , Humans , Male , Middle Aged , Prospective Studies , Prostate/diagnostic imaging , Prostate/metabolism , Reproducibility of Results
10.
Neuroimage ; 195: 362-372, 2019 07 15.
Article in English | MEDLINE | ID: mdl-30923028

ABSTRACT

Fully-quantitative MR imaging methods are useful for longitudinal characterization of disease and assessment of treatment efficacy. However, current quantitative MRI protocols have not been widely adopted in the clinic, mostly due to lengthy scan times. Magnetic Resonance Fingerprinting (MRF) is a new technique that can reconstruct multiple parametric maps from a single fast acquisition in the transient state of the MR signal. Due to the relative novelty of this technique, the repeatability and reproducibility of quantitative measurements obtained using MRF has not been extensively studied. Our study acquired test/retest data from the brains of nine healthy volunteers, each scanned on five MRI systems (two at 3.0 T and three at 1.5 T, all from a single vendor) located at two different centers. The pulse sequence and reconstruction algorithm were the same for all acquisitions. After registration of the MRF-derived M0, T1 and T2 maps to an anatomical atlas, coefficients-of-variation (CVs) were computed to assess test/retest repeatability and inter-site reproducibility in each voxel, while a General Linear Model (GLM) was used to determine the voxel-wise variability between all confounders, which included test/retest, subject, field strength and site. Our analysis demonstrated an excellent repeatability (CVs of 2-3% for T1, 5-8% for T2, 3% for normalized-M0) and a good reproducibility (CVs of 3-8% for T1, 8-14% for T2, 5% for normalized-M0) in grey and white matter.


Subject(s)
Brain Mapping/methods , Brain/physiology , Magnetic Resonance Imaging/methods , Adolescent , Adult , Female , Humans , Male , Middle Aged , Reproducibility of Results , Young Adult
11.
Neuroimage ; 189: 171-179, 2019 04 01.
Article in English | MEDLINE | ID: mdl-30639333

ABSTRACT

Hyperpolarized 13C Magnetic Resonance Imaging (13C-MRI) provides a highly sensitive tool to probe tissue metabolism in vivo and has recently been translated into clinical studies. We report the cerebral metabolism of intravenously injected hyperpolarized [1-13C]pyruvate in the brain of healthy human volunteers for the first time. Dynamic acquisition of 13C images demonstrated 13C-labeling of both lactate and bicarbonate, catalyzed by cytosolic lactate dehydrogenase and mitochondrial pyruvate dehydrogenase respectively. This demonstrates that both enzymes can be probed in vivo in the presence of an intact blood-brain barrier: the measured apparent exchange rate constant (kPL) for exchange of the hyperpolarized 13C label between [1-13C]pyruvate and the endogenous lactate pool was 0.012 ±â€¯0.006 s-1 and the apparent rate constant (kPB) for the irreversible flux of [1-13C]pyruvate to [13C]bicarbonate was 0.002 ±â€¯0.002 s-1. Imaging also revealed that [1-13C]pyruvate, [1-13C]lactate and [13C]bicarbonate were significantly higher in gray matter compared to white matter. Imaging normal brain metabolism with hyperpolarized [1-13C]pyruvate and subsequent quantification, have important implications for interpreting pathological cerebral metabolism in future studies.


Subject(s)
Brain/diagnostic imaging , Brain/metabolism , Carbon Isotopes , Magnetic Resonance Imaging/methods , Neuroimaging/methods , Pyruvic Acid , Adult , Female , Humans , Male
12.
J Neurol Neurosurg Psychiatry ; 90(7): 755-760, 2019 07.
Article in English | MEDLINE | ID: mdl-30948625

ABSTRACT

OBJECTIVE: Sodium (23Na)-MRI is an emerging imaging technique to investigate in vivo changes in tissue viability, reflecting neuroaxonal integrity and metabolism. Using an optimised 23Na-MRI protocol with smaller voxel sizes and improved tissue contrast, we wanted to investigate whether brain total sodium concentration (TSC) is a biomarker for long-term disease outcomes in a cohort of patients with relapse-onset multiple sclerosis (MS), followed from disease onset. METHODS: We performed a cross-sectional study in 96 patients followed up ~ 15 years after a clinically isolated syndrome (CIS) and 34 healthy controls. Disease course was classified as CIS, relapsing-remitting MS or secondary progressive MS (SPMS). We acquired 1H-MRI and 23Na-MRI and calculated the TSC in cortical grey matter (CGM), deep grey matter, normal-appearing white matter (WM) and WM lesions. Multivariable linear regression was used to identify independent associations of tissue-specific TSC with physical disability and cognition, with adjustment for tissue volumes. RESULTS: TSC in all tissues was higher in patients with MS compared with healthy controls and patients who remained CIS, with differences driven by patients with SPMS. Higher CGM TSC was independently associated with Expanded Disability Status Scale (R2=0.26), timed 25-foot walk test (R2=0.23), 9-hole peg test (R2=0.23), Paced Auditory Serial Addition Test (R2=0.29), Symbol Digit Modalities Test (R2=0.31) and executive function (R2=0.36) test scores, independent of grey matter atrophy. CONCLUSIONS: Sodium accumulation in CGM reflects underlying neuroaxonal metabolic abnormalities relevant to disease course heterogeneity and disability in relapse-onset MS. TSC and should be considered as an outcome measure in future neuroprotection trials.


Subject(s)
Brain/diagnostic imaging , Gray Matter/pathology , Multiple Sclerosis/pathology , Sodium/metabolism , Adult , Brain/metabolism , Brain Chemistry , Case-Control Studies , Cross-Sectional Studies , Female , Gray Matter/chemistry , Gray Matter/metabolism , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Multiple Sclerosis/metabolism , Multiple Sclerosis, Chronic Progressive/metabolism , Multiple Sclerosis, Chronic Progressive/pathology , Multiple Sclerosis, Relapsing-Remitting/metabolism , Multiple Sclerosis, Relapsing-Remitting/pathology , Neuroimaging , Sodium/analysis
13.
J Magn Reson Imaging ; 50(4): 1278-1284, 2019 10.
Article in English | MEDLINE | ID: mdl-30859655

ABSTRACT

BACKGROUND: Sodium MRI (23 Na-MRI)-derived biomarkers such as total sodium concentration (TSC) have the potential to provide information on tumor cellularity and the changes in tumor microstructure that occur following therapy. PURPOSE: To evaluate the repeatability and reproducibility of TSC measurements in the brains of healthy volunteers, providing evidence for the technical validation of 23 Na-MRI-derived biomarkers. STUDY TYPE: Prospective multicenter study. SUBJECTS: Eleven volunteers (32 ± 6 years; eight males, three females) were scanned twice at each of two sites. FIELD STRENGTH/SEQUENCE: Comparable 3D-cones 23 Na-MRI ultrashort echo time acquisitions at 3T. ASSESSMENT: TSC values, quantified from calibration phantoms placed in the field of view, were obtained from white matter (WM), gray matter (GM), and cerebrospinal fluid (CSF), based on automated segmentation of coregistered 1 H T1 -weighted images and hand-drawn regions of interest by two readers. STATISTICAL TESTS: Coefficients of variation (CoVs) from mean TSC values were used to assess intrasite repeatability and intersite reproducibility. RESULTS: Mean GM TSC concentrations (52.1 ± 7.1 mM) were ∼20% higher than for WM (41.8 ± 6.7 mM). Measurements were highly repeatable at both sites with mean scan-rescan CoVs between volunteers and regions of 2% and 4%, respectively. Mean intersite reproducibility CoVs were 3%, 3%, and 6% for WM, GM, and CSF, respectively. DATA CONCLUSION: These results demonstrate technical validation of sodium MRI-derived biomarkers in healthy volunteers. We also show that comparable 23 Na imaging of the brain can be implemented across different sites and scanners with excellent repeatability and reproducibility. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1278-1284.


Subject(s)
Gray Matter/metabolism , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Sodium Isotopes , Sodium/metabolism , White Matter/metabolism , Adult , Biomarkers/cerebrospinal fluid , Biomarkers/metabolism , Female , Humans , Male , Prospective Studies , Reference Values , Reproducibility of Results , Sodium/cerebrospinal fluid
14.
Eur Radiol ; 29(10): 5559-5566, 2019 Oct.
Article in English | MEDLINE | ID: mdl-30888488

ABSTRACT

PURPOSE: This prospective study evaluated the use of vascular, extracellular and restricted diffusion for cytometry in tumours (VERDICT) MRI to investigate the tissue microstructure in glioma. VERDICT-derived parameters were correlated with both histological features and tumour subtype and were also used to explore the peritumoural region. METHODS: Fourteen consecutive treatment-naïve patients (43.5 years ± 15.1 years, six males, eight females) with suspected glioma underwent diffusion-weighted imaging including VERDICT modelling. Tumour cell radius and intracellular and combined extracellular/vascular volumes were estimated using a framework based on linearisation and convex optimisation. An experienced neuroradiologist outlined the peritumoural oedema, enhancing tumour and necrosis on T2-weighted imaging and contrast-enhanced T1-weighted imaging. The same regions of interest were applied to the co-registered VERDICT maps to calculate the microstructure parameters. Pathology sections were analysed with semi-automated software to measure cellularity and cell size. RESULTS: VERDICT parameters were successfully calculated in all patients. The imaging-derived results showed a larger intracellular volume fraction in high-grade glioma compared to low-grade glioma (0.13 ± 0.07 vs. 0.08 ± 0.02, respectively; p = 0.05) and a trend towards a smaller extracellular/vascular volume fraction (0.88 ± 0.07 vs. 0.92 ± 0.04, respectively; p = 0.10). The conventional apparent diffusion coefficient was higher in low-grade gliomas compared to high-grade gliomas, but this difference was not statistically significant (1.22 ± 0.13 × 10-3 mm2/s vs. 0.98 ± 0.38 × 10-3 mm2/s, respectively; p = 0.18). CONCLUSION: This feasibility study demonstrated that VERDICT MRI can be used to explore the tissue microstructure of glioma using an abbreviated protocol. The VERDICT parameters of tissue structure correlated with those derived on histology. The method shows promise as a potential test for diagnostic stratification and treatment response monitoring in the future. KEY POINTS: • VERDICT MRI is an advanced diffusion technique which has been correlated with histopathological findings obtained at surgery from patients with glioma in this study. • The intracellular volume fraction measured with VERDICT was larger in high-grade tumours compared to that in low-grade tumours. • The results were complementary to measurements from conventional diffusion-weighted imaging, and the technique could be performed in a clinically feasible timescale.


Subject(s)
Brain Neoplasms/diagnostic imaging , Glioma/diagnostic imaging , Adult , Aged , Brain Neoplasms/pathology , Diffusion Magnetic Resonance Imaging/methods , Feasibility Studies , Female , Glioma/pathology , Humans , Magnetic Resonance Angiography/methods , Male , Middle Aged , Neoplasm Grading , Prospective Studies , Reproducibility of Results , Young Adult
15.
Acta Radiol ; 60(1): 35-44, 2019 Jan.
Article in English | MEDLINE | ID: mdl-29742918

ABSTRACT

BACKGROUND: The goals of neoadjuvant chemotherapy (NAC) are to reduce tumor volume and to offer a prognostic indicator in assessing treatment response. Contrast-enhanced magnetic resonance imaging (CE-MRI) is an established method for evaluating response to NAC in patients with breast cancer. PURPOSE: To validate the role of unenhanced MRI (ue-MRI) compared to CE-MRI for assessing response to NAC in women with breast cancer. MATERIAL AND METHODS: Seventy-one patients with ongoing NAC for breast cancer underwent MRI before, during, and at the end of NAC. Ue-MRI was performed with T2-weighted sequences with iterative decomposition of water and fat and diffusion-weighted sequences. CE-MRI was performed using three-dimensional T1-weighted sequences before and after administration of gadobenate dimeglumine. Two blinded observers rated ue-MRI and CE-MRI for the evaluation of tumor response. Statistical analysis was performed to compare lesion size and ADC values changes during therapy, as well as inter-observer agreement. RESULTS: There were no statistically significant differences between ue-MRI and CE-MRI sequences for evaluation of lesion size at baseline and after every cycle of treatment ( P > 0.05). The mean tumor ADC values at baseline and across the cycles of NAC were significantly different for the responder group. CONCLUSION: Ue-MRI can achieve similar results to CE-MRI for the assessment of tumor response to NAC. ADC values can differentiate responders from non-responders.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/drug therapy , Contrast Media , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Neoadjuvant Therapy/methods , Adult , Aged , Breast/diagnostic imaging , Chemotherapy, Adjuvant , Female , Humans , Meglumine/analogs & derivatives , Middle Aged , Organometallic Compounds , Reproducibility of Results , Treatment Outcome
16.
NMR Biomed ; 31(5): e3899, 2018 05.
Article in English | MEDLINE | ID: mdl-29480533

ABSTRACT

The purpose of this study was to measure the sodium transverse relaxation time T2 * in the healthy human brain. Five healthy subjects were scanned with 18 echo times (TEs) as short as 0.17 ms. T2 * values were fitted on a voxel-by-voxel basis using a bi-exponential model. Data were also analysed using a continuous distribution fit with a region of interest-based inverse Laplace transform. Average T2 * values were 3.4 ± 0.2 ms and 23.5 ± 1.8 ms in white matter (WM) for the short and long components, respectively, and 3.9 ± 0.5 ms and 26.3 ± 2.6 ms in grey matter (GM) for the short and long components, respectively, using the bi-exponential model. Continuous distribution fits yielded results of 3.1 ± 0.3 ms and 18.8 ± 3.2 ms in WM for the short and long components, respectively, and 2.9 ± 0.4 ms and 17.2 ± 2 ms in GM for the short and long components, respectively. 23 Na T2 * values of the brain for the short and long components for various anatomical locations using ultra-short TEs are presented for the first time.


Subject(s)
Brain/diagnostic imaging , Magnetic Resonance Imaging , Sodium/chemistry , Adult , Female , Gray Matter/diagnostic imaging , Humans , Male , Phantoms, Imaging , Signal Processing, Computer-Assisted , White Matter/diagnostic imaging
17.
Brain ; 136(Pt 7): 2305-17, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23801742

ABSTRACT

Neuroaxonal loss is a major substrate of irreversible disability in multiple sclerosis, however, its cause is not understood. In multiple sclerosis there may be intracellular sodium accumulation due to neuroaxonal metabolic dysfunction, and increased extracellular sodium due to expansion of the extracellular space secondary to neuroaxonal loss. Sodium magnetic resonance imaging measures total sodium concentration in the brain, and could investigate this neuroaxonal dysfunction and loss in vivo. Sodium magnetic resonance imaging has been examined in small cohorts with relapsing-remitting multiple sclerosis, but has not been investigated in patients with a progressive course and high levels of disability. We performed sodium magnetic resonance imaging in 27 healthy control subjects, 27 patients with relapsing-remitting, 23 with secondary-progressive and 20 with primary-progressive multiple sclerosis. Cortical sodium concentrations were significantly higher in all subgroups of multiple sclerosis compared with controls, and deep grey and normal appearing white matter sodium concentrations were higher in primary and secondary-progressive multiple sclerosis. Sodium concentrations were higher in secondary-progressive compared with relapsing-remitting multiple sclerosis in cortical grey matter (41.3 ± 4.2 mM versus 38.5 ± 2.8 mM, P = 0.008), normal appearing white matter (36.1 ± 3.5 mM versus 33.6 ± 2.5 mM, P = 0.018) and deep grey matter (38.1 ± 3.1 mM versus 35.7 ± 2.4 mM, P = 0.02). Higher sodium concentrations were seen in T1 isointense (44.6 ± 7.2 mM) and T1 hypointense lesions (46.8 ± 8.3 mM) compared with normal appearing white matter (34.9 ± 3.3 mM, P < 0.001 for both comparisons). Higher sodium concentration was observed in T1 hypointense lesions in secondary-progressive (49.0 ± 7.0 mM) and primary-progressive (49.3 ± 8.0 mM) compared with relapsing-remitting multiple sclerosis (43.0 ± 8.5 mM, P = 0.029 for both comparisons). Independent association was seen of deep grey matter sodium concentration with expanded disability status score (coefficient = 0.24, P = 0.003) and timed 25 ft walk speed (coefficient = -0.24, P = 0.01), and of T1 lesion sodium concentration with the z-scores of the nine hole peg test (coefficient = -0.12, P < 0.001) and paced auditory serial addition test (coefficient = -0.081, P < 0.001). Sodium concentration is increased within lesions, normal appearing white matter and cortical and deep grey matter in multiple sclerosis, with higher concentrations seen in secondary-progressive multiple sclerosis and in patients with greater disability. Increased total sodium concentration is likely to reflect neuroaxonal pathophysiology leading to clinical progression and increased disability.


Subject(s)
Disabled Persons , Disease Progression , Multiple Sclerosis/metabolism , Multiple Sclerosis/physiopathology , Sodium/metabolism , Adolescent , Adult , Aged , Analysis of Variance , Brain/metabolism , Brain/pathology , Disability Evaluation , Female , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging , Male , Middle Aged , Multiple Sclerosis/cerebrospinal fluid , Multiple Sclerosis/pathology , Sodium Isotopes , Statistics as Topic , Young Adult
18.
MAGMA ; 27(1): 35-46, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23900703

ABSTRACT

OBJECT: Sodium magnetic resonance imaging ((23)Na-MRI) of the brain has shown changes in (23)Na signal as a hallmark of various neurological diseases such as stroke, Alzheimer's disease, Multiple Sclerosis and Huntington's disease. To improve scan times and image quality, we have implemented the 3D-Cones (CN) sequence for in vivo (23)Na brain MRI. MATERIALS AND METHODS: Using signal-to-noise (SNR) as a measurement of sequence performance, CN is compared against more established 3D-radial k-space sampling schemes featuring cylindrical stack-of-stars (SOS) and 3D-spokes kooshball (KB) trajectories, on five healthy volunteers in a clinical setting. Resolution was evaluated by simulating the point-spread-functions (PSFs) and experimental measures on a phantom. RESULTS: All sequences were shown to have a similar SNR arbitrary units (AU) of 6-6.5 in brain white matter, 7-9 in gray matter and 17-18 AU in cerebrospinal fluid. SNR between white and gray matter were significantly different for KB and CN (p = 0.046 and <0.001 respectively), but not for SOS (p = 0.1). Group mean standard deviations were significantly smaller for CN (p = 0.016). Theoretical full-width at half-maximum linewidth of the PSF for CN is broadened by only 0.1, compared to 0.3 and 0.8 pixels for SOS and KB respectively. Actual image resolution is estimated as 8, 9 and 6.3 mm for SOS, KB and CN respectively. CONCLUSION: The CN sequence provides stronger tissue contrast than both SOS and KB, with more reproducible SNR measurements compared to KB. For CN, a higher true resolution in the same amount of time with no significant trade-off in SNR is achieved. CN is therefore more suitable for (23)Na-MRI in the brain.


Subject(s)
Brain/pathology , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Sodium/chemistry , Adult , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Phantoms, Imaging , Reproducibility of Results , Signal-To-Noise Ratio
19.
Eur Radiol Exp ; 8(1): 75, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38853182

ABSTRACT

BACKGROUND: To study the reproducibility of 23Na magnetic resonance imaging (MRI) measurements from breast tissue in healthy volunteers. METHODS: Using a dual-tuned bilateral 23Na/1H breast coil at 3-T MRI, high-resolution 23Na MRI three-dimensional cones sequences were used to quantify total sodium concentration (TSC) and fluid-attenuated sodium concentration (FASC). B1-corrected TSC and FASC maps were created. Two readers manually measured mean, minimum and maximum TSC and mean FASC values using two sampling methods: large regions of interest (LROIs) and small regions of interest (SROIs) encompassing fibroglandular tissue (FGT) and the highest signal area at the level of the nipple, respectively. The reproducibility of the measurements and correlations between density, age and FGT apparent diffusion coefficient (ADC) values were evaluatedss. RESULTS: Nine healthy volunteers were included. The inter-reader reproducibility of TSC and FASC using SROIs and LROIs was excellent (intraclass coefficient range 0.945-0.979, p < 0.001), except for the minimum TSC LROI measurements (p = 0.369). The mean/minimum LROI TSC and mean LROI FASC values were lower than the respective SROI values (p < 0.001); the maximum LROI TSC values were higher than the SROI TSC values (p = 0.009). TSC correlated inversely with age but not with FGT ADCs. The mean and maximum FGT TSC and FASC values were higher in dense breasts in comparison to non-dense breasts (p < 0.020). CONCLUSIONS: The chosen sampling method and the selected descriptive value affect the measured TSC and FASC values, although the inter-reader reproducibility of the measurements is in general excellent. RELEVANCE STATEMENT: 23Na MRI at 3 T allows the quantification of TSC and FASC sodium concentrations. The sodium measurements should be obtained consistently in a uniform manner. KEY POINTS: • 23Na MRI allows the quantification of total and fluid-attenuated sodium concentrations (TSC/FASC). • Sampling method (large/small region of interest) affects the TSC and FASC values. • Dense breasts have higher TSC and FASC values than non-dense breasts. • The inter-reader reproducibility of TSC and FASC measurements was, in general, excellent. • The results suggest the importance of stratifying the sodium measurements protocol.


Subject(s)
Breast , Magnetic Resonance Imaging , Sodium , Humans , Female , Reproducibility of Results , Adult , Magnetic Resonance Imaging/methods , Breast/diagnostic imaging , Middle Aged , Sodium Isotopes , Healthy Volunteers , Observer Variation , Young Adult
20.
Prog Neurobiol ; 236: 102603, 2024 May.
Article in English | MEDLINE | ID: mdl-38604582

ABSTRACT

The STRAT-PARK initiative aims to provide a platform for stratifying Parkinson's disease (PD) into biological subtypes, using a bottom-up, multidisciplinary biomarker-based and data-driven approach. PD is a heterogeneous entity, exhibiting high interindividual clinicopathological variability. This diversity suggests that PD may encompass multiple distinct biological entities, each driven by different molecular mechanisms. Molecular stratification and identification of disease subtypes is therefore a key priority for understanding and treating PD. STRAT-PARK is a multi-center longitudinal cohort aiming to recruit a total of 2000 individuals with PD and neurologically healthy controls from Norway and Canada, for the purpose of identifying molecular disease subtypes. Clinical assessment is performed annually, whereas biosampling, imaging, and digital and neurophysiological phenotyping occur every second year. The unique feature of STRAT-PARK is the diversity of collected biological material, including muscle biopsies and platelets, tissues particularly useful for mitochondrial biomarker research. Recruitment rate is ∼150 participants per year. By March 2023, 252 participants were included, comprising 204 cases and 48 controls. STRAT-PARK is a powerful stratification initiative anticipated to become a global research resource, contributing to personalized care in PD.


Subject(s)
Parkinson Disease , Aged , Female , Humans , Male , Middle Aged , Biomarkers , Canada , Cohort Studies , Longitudinal Studies , Norway , Parkinson Disease/diagnosis , Parkinson Disease/physiopathology , Precision Medicine/methods
SELECTION OF CITATIONS
SEARCH DETAIL