Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
J Cardiovasc Magn Reson ; 26(1): 101001, 2024.
Article in English | MEDLINE | ID: mdl-38244931

ABSTRACT

BACKGROUND: Acute myocardial injury is a common diagnosis in the emergency department and differential diagnoses are numerous. Cardiac magnetic resonance (CMR) strain sequences, such as fast strain ENCoded (fSENC), are early predictors of myocardial function loss. This study assessed the potential diagnostic and prognostic benefits of a layer-specific approach. METHODS: For this prospective study, patients in the emergency department fulfilling rule-in criteria for non-ST-elevation myocardial infarction (NSTEMI) received an ultra-fast fSENC CMR. Volunteers without cardiac diseases (controls) were recruited for comparison. Measurements were performed in a single heartbeat acquisition to measure global longitudinal strain (GLS) and segmental longitudinal strain and dysfunctional segments. The GLS was measured in two layers and a difference (GLSdifference = GLSepicardial - GLSendocardial) was calculated. The performance of those strain features was compared to standard care (physical examination, cardiac biomarkers, electrocardiogram). According to the final diagnosis after discharge, patients were divided into groups and followed up for 2 years. RESULTS: A total of 114 participants, including 50 controls, were included. The 64 patients (51 male) were divided into a NSTEMI (25), myocarditis (16), and other myocardial injury group (23). GLS served as a potent predictor of myocardial injury (area under the curve (AUC) 91.8%). The GLSdifference provided an excellent diagnostic performance to identify a NSTEMI (AUC 83.2%), further improved by including dysfunctional segments (AUC 87.5%, p = 0.01). An optimal test was achieved by adding fSENC to standard care (AUC 95.5%, sensitivity 96.0%, specificity 86.5%, p = 0.03). No death occurred in 2 years for patients with normal GLS and ≤5 dysfunctional segments, while three patients died that showed abnormal GLS or >5 dysfunctional segments. CONCLUSIONS: Layer-specific strain is a potential new marker with high diagnostic performance in the identification and differentiation of acute myocardial injuries.


Subject(s)
Magnetic Resonance Imaging, Cine , Non-ST Elevated Myocardial Infarction , Predictive Value of Tests , Proof of Concept Study , Humans , Prospective Studies , Male , Female , Middle Aged , Aged , Case-Control Studies , Non-ST Elevated Myocardial Infarction/diagnostic imaging , Non-ST Elevated Myocardial Infarction/physiopathology , Ventricular Function, Left , Adult , Diagnosis, Differential , Reproducibility of Results , Myocardial Contraction , Prognosis , Time Factors , Image Interpretation, Computer-Assisted , Heart Rate , Biomechanical Phenomena
2.
Circ Cardiovasc Imaging ; 17(2): e016090, 2024 02.
Article in English | MEDLINE | ID: mdl-38377242

ABSTRACT

BACKGROUND: Cardiovascular magnetic resonance (CMR) reference values are relied upon to accurately diagnose left ventricular (LV) and right ventricular (RV) pathologies. To date, reference values have been derived from modest sample sizes with limited patient diversity and attention to 1 but not both commonly used tracing techniques for papillary muscles and trabeculations. We sought to overcome these limitations by meta-analyzing normal reference values for CMR parameters stemming from multiple countries, vendors, analysts, and patient populations. METHODS: We comprehensively extracted published and unpublished data from studies reporting CMR parameters in healthy adults. A steady-state free-precession short-axis stack at 1.5T or 3T was used to trace either counting the papillary muscles and trabeculations in the LV volume or mass. We used a novel Bayesian hierarchical meta-analysis model to derive the pooled lower and upper reference values for each CMR parameter. Our model accounted for the expected differences between tracing techniques by including informative prior distributions from a large external data set. RESULTS: A total of 254 studies from 25 different countries were systematically reviewed, representing 12 812 healthy adults, of which 52 were meta-analyzed. For LV parameters counting papillary muscles and trabeculations in the LV volume, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 52% to 73% and 54% to 75%, LV end-diastolic volume index of 60 to 109 and 56 to 96 mL/m2, LV end-systolic volume index of 18 to 45 and 16 to 38 mL/m2, and LV mass index of 41 to 76 and 33 to 57 g/m2. For LV parameters counting papillary muscles and trabeculations in the LV mass, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 57% to 74% and 57% to 75%, LV end-diastolic volume index of 60 to 97 and 55 to 88 mL/m2, LV end-systolic volume index of 18 to 37 and 15 to 34 mL/m2, and LV mass index of 50 to 83 and 38 to 65 g/m2. For RV parameters, pooled normative reference ranges in men and women, respectively, were as follows: RV ejection fraction of 47% to 68% and 49% to 71%, RV end-diastolic volume index of 64 to 115 and 57 to 99 mL/m2, RV end-systolic volume index of 23 to 52 and 18 to 42 mL/m2, and RV mass index of 14 to 29 and 13 to 25 g/m2. CONCLUSIONS: Our Bayesian hierarchical meta-analysis provides normative reference values for CMR parameters of LV and RV size, systolic function, and mass, encompassing both tracing techniques across a diverse multinational sample of healthy men and women.


Subject(s)
Heart Ventricles , Ventricular Function, Left , Adult , Male , Humans , Female , Reference Values , Bayes Theorem , Heart Ventricles/diagnostic imaging , Stroke Volume , Papillary Muscles , Magnetic Resonance Spectroscopy , Magnetic Resonance Imaging, Cine , Reproducibility of Results
3.
Diagnostics (Basel) ; 14(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38732294

ABSTRACT

Reduced iodine loads for computed tomography (CT)-based vascular assessment prior to transcatheter aortic valve implantation (TAVI) may be feasible in conjunction with a spectral detector CT scanner. This prospective single-center study considered 100 consecutive patients clinically referred for pre-TAVI CT. They were examined on a dual-layer detector CT scanner to obtain an ECG-gated cardiac scan and a non-ECG-gated aortoiliofemoral scan. Either a standard contrast media (SCM) protocol using 80 mL Iohexol 350 mgI/mL (iodine load: 28 gI) or a body-mass-index adjusted reduced contrast media (RCM) protocol using 40-70 mL Iohexol 350 mgI/mL (iodine load: 14-24.5 gI) were employed. Conventional images and virtual monoenergetic images at 40-80 keV were reconstructed. A threshold of 250 HU was set for sufficient attenuation along the arterial access pathway. A qualitative assessment used a five-point Likert scale. Sufficient attenuation in the thoracic aorta was observed for all patients in both groups using conventional images. In the abdominal, iliac, and femoral segments, sufficient attenuation was observed for the majority of patients when using virtual monoenergetic images (SCM: 96-100% of patients, RCM: 88-94%) without statistical difference between both groups. Segments with attenuation measurements below the threshold remained qualitatively assessable as well. Likert scores were 'excellent' for virtual monoenergetic images 50 keV and 55 keV in both groups (RCM: 1.2-1.4, SCM: 1.2-1.3). With diagnostic image quality maintained, it can be concluded that reduced iodine loads of 14-24.5 gI are feasible for pre-TAVI vascular assessment on a spectral detector CT scanner.

SELECTION OF CITATIONS
SEARCH DETAIL