Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
Add more filters

Country/Region as subject
Affiliation country
Publication year range
1.
Eur Radiol ; 28(9): 3929-3935, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29594401

ABSTRACT

OBJECTIVES: To examine radiation dose levels of CT-guided interventional procedures of chest, abdomen, spine and extremities on different CT-scanner generations at a large multicentre institute. MATERIALS AND METHODS: 1,219 CT-guided interventional biopsies of different organ regions ((A) abdomen (n=516), (B) chest (n=528), (C) spine (n=134) and (D) extremities (n=41)) on different CT-scanners ((I) SOMATOM-Definition-AS+, (II) Volume-Zoom, (III) Emotion6) were included from 2013-2016. Important CT-parameters and standard dose-descriptors were retrospectively examined. Additionally, effective dose and organ doses were calculated using Monte-Carlo simulation, following ICRP103. RESULTS: Overall, radiation doses for CT interventions are highly dependent on CT-scanner generation: the newer the CT scanner, the lower the radiation dose imparted to patients. Mean effective doses for each of four procedures on available scanners are: (A) (I) 9.3mSv versus (II) 13.9mSv (B) (I) 7.3mSv versus (III) 11.4mSv (C) (I) 6.3mSv versus (II) 7.4mSv (D) (I) 4.3mSv versus (II) 10.8mSv. Standard dose descriptors [standard deviation (SD); CT dose indexvol (CTDIvol); dose-length product (DLPbody); size-specific dose estimate (SSDE)] were also compared. CONCLUSION: Effective dose, organ doses and SSDE for various CT-guided interventional biopsies on different CT-scanner generations following recommendations of the ICRP103 are provided. New CT-scanner generations involve markedly lower radiation doses versus older devices. KEY POINTS: • Effective dose, organ dose and SSDE are provided for CT-guided interventional examinations. • These data allow identifying organs at risk of higher radiation dose. • Detailed knowledge of radiation dose may contribute to a better individual risk-stratification. • New CT-scanner generations involve markedly lower radiation doses compared to older devices.


Subject(s)
Image-Guided Biopsy/methods , Multidetector Computed Tomography/methods , Radiation Dosage , Radiation Exposure , Abdomen/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Extremities/diagnostic imaging , Female , Humans , Male , Middle Aged , Monte Carlo Method , Phantoms, Imaging , Retrospective Studies , Spine/diagnostic imaging , Thorax/diagnostic imaging , Young Adult
2.
Acta Radiol ; 59(3): 322-326, 2018 Mar.
Article in English | MEDLINE | ID: mdl-28618854

ABSTRACT

Background The importance of monitoring of the radiation dose received by the human body during computed tomography (CT) examinations is not negligible. Several dose-monitoring software tools emerged in order to monitor and control dose distribution during CT examinations. Some software tools incorporate Monte Carlo Simulation (MCS) and allow calculation of effective dose and organ dose apart from standard dose descriptors. Purpose To verify the results of a dose-monitoring software tool based on MCS in assessment of effective and organ doses in thoracic CT protocols. Material and Methods Phantom measurements were performed with thermoluminescent dosimeters (TLD LiF:Mg,Ti) using two different thoracic CT protocols of the clinical routine: (I) standard CT thorax (CTT); and (II) CTT with high-pitch mode, P = 3.2. Radiation doses estimated with MCS and measured with TLDs were compared. Results Inter-modality comparison showed an excellent correlation between MCS-simulated and TLD-measured doses ((I) after localizer correction r = 0.81; (II) r = 0.87). The following effective and organ doses were determined: (I) (a) effective dose = MCS 1.2 mSv, TLD 1.3 mSv; (b) thyroid gland = MCS 2.8 mGy, TLD 2.5 mGy; (c) thymus = MCS 3.1 mGy, TLD 2.5 mGy; (d) bone marrow = MCS 0.8 mGy, TLD 0.9 mGy; (e) breast = MCS 2.5 mGy, TLD 2.2 mGy; (f) lung = MCS 2.8 mGy, TLD 2.7 mGy; (II) (a) effective dose = MCS 0.6 mSv, TLD 0.7 mSv; (b) thyroid gland = MCS 1.4 mGy, TLD 1.8 mGy; (c) thymus = MCS 1.4 mGy, TLD 1.8 mGy; (d) bone marrow = MCS 0.4 mGy, TLD 0.5 mGy; (e) breast = MCS 1.1 mGy, TLD 1.1 mGy; (f) lung = MCS 1.2 mGy, TLD 1.3 mGy. Conclusion Overall, in thoracic CT protocols, organ doses simulated by the dose-monitoring software tool were coherent to those measured by TLDs. Despite some challenges, the dose-monitoring software was capable of an accurate dose calculation.


Subject(s)
Monte Carlo Method , Radiation Dosage , Radiography, Thoracic/methods , Tomography, X-Ray Computed/methods , Humans , Phantoms, Imaging , Reproducibility of Results , Software
3.
Laryngorhinootologie ; 96(9): 607-614, 2017 Sep.
Article in German | MEDLINE | ID: mdl-28683511

ABSTRACT

Background Schwannomas are rare benign tumors originating from the perineural cells forming the myelin layer in the peripheral nervous system (PNS). While well established therapeutic concepts exist for intracranial schwannomas, there is a lack of consistent clinical standards for extracranial schwannomas. Method This retrospective study describes the clinical pathway of 20 patients with histologically proven extracranial schwannomas of the head and neck. The diagnostic and therapeutic strategies for schwannomas are discussed with special emphasis on localization and functional outcome. Results Extracranial schwannomas of the head and neck region mostly originated from the facial nerve (n = 4), vagal nerve (n = 4) or sympathetic chain (n = 3). Most common symptoms were swelling (n = 12) and pain (n = 3). Preoperative imaging included MRI (n = 13), ultrasound (n = 12) and CT (n = 3). Surgical intervention was performed in 18 cases (n = 14 complete extirpation, n = 3 partial extirpation, n = 1 unknown). Regarding completely extirpated schwannomas of motor nerves (n = 10) severing the nerve of origin was more often required in patients with a preexisting functional deficit (3 out of 4 = 75 %) than in patients without preexisting deficits (2 out of 6 = 33 %). Conclusion Representing rare tumors of the head and neck region mostly originating from the facial nerve, sympathetic chain or caudal cranial nerves extracranial schwannomas require a systematic diagnostic and therapeutic approach. Postoperative functional deficits after complete extirpation must especially be anticipated in patients with a preexisting functional deficit.


Subject(s)
Neurilemmoma/surgery , Otorhinolaryngologic Neoplasms/surgery , Adult , Aged , Cranial Nerves/pathology , Cranial Nerves/surgery , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Neurilemmoma/diagnosis , Neurilemmoma/pathology , Neurologic Examination , Otorhinolaryngologic Neoplasms/diagnosis , Otorhinolaryngologic Neoplasms/pathology , Postoperative Complications/etiology , Tomography, X-Ray Computed , Ultrasonography
4.
Neuroradiology ; 58(10): 955-959, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27438801

ABSTRACT

INTRODUCTION: The aim of this study was to verify the results of a dose monitoring software tool based on Monte Carlo Simulation (MCS) in assessment of eye lens doses for cranial CT scans. METHODS: In cooperation with the Federal Office for Radiation Protection (Neuherberg, Germany), phantom measurements were performed with thermoluminescence dosimeters (TLD LiF:Mg,Ti) using cranial CT protocols: (I) CT angiography; (II) unenhanced, cranial CT scans with gantry angulation at a single and (III) without gantry angulation at a dual source CT scanner. Eye lens doses calculated by the dose monitoring tool based on MCS and assessed with TLDs were compared. RESULTS: Eye lens doses are summarized as follows: (I) CT angiography (a) MCS 7 mSv, (b) TLD 5 mSv; (II) unenhanced, cranial CT scan with gantry angulation, (c) MCS 45 mSv, (d) TLD 5 mSv; (III) unenhanced, cranial CT scan without gantry angulation (e) MCS 38 mSv, (f) TLD 35 mSv. Intermodality comparison shows an inaccurate calculation of eye lens doses in unenhanced cranial CT protocols at the single source CT scanner due to the disregard of gantry angulation. On the contrary, the dose monitoring tool showed an accurate calculation of eye lens doses at the dual source CT scanner without gantry angulation and for CT angiography examinations. CONCLUSION: The dose monitoring software tool based on MCS gave accurate estimates of eye lens doses in cranial CT protocols. However, knowledge of protocol and software specific influences is crucial for correct assessment of eye lens doses in routine clinical use.


Subject(s)
Brain/diagnostic imaging , Monte Carlo Method , Ocular Physiological Phenomena , Radiation Exposure/analysis , Radiometry/methods , Software , Tomography, X-Ray Computed/methods , Absorption, Radiation/physiology , Algorithms , Computer Simulation , Germany , Humans , Models, Statistical , Phantoms, Imaging , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/instrumentation
5.
Acta Radiol ; 57(4): 437-43, 2016 Apr.
Article in English | MEDLINE | ID: mdl-25907120

ABSTRACT

BACKGROUND: The contrast enhancement of pulmonary nodules is a differential diagnostic criterion which can be helpful in staging investigations. PURPOSE: To investigate the impact of dual-energy computed tomography (DECT) with regards to the evaluation of pulmonary nodules with emphasis on metastatic lesions. MATERIAL AND METHODS: DECT scans of the thorax were performed in 70 consecutive patients. Data of the lung were acquired in the arterial and in delayed venous phase. The virtual native and overlay image data based on arterial and delayed venous phase of these lesions were compared using CT density values (HU) within the nodule tested for statistical significance. RESULTS: A total of 156 pulmonary lesions ≥5 mm were identified on 70 DECT scans. There were no significant differences between the CT-value measurements in the virtual native images based on the arterial and delayed venous phase (27.9+/-3.9 HU vs.28.1+/-4.2 HU, P = 0.89) and between the CT-value measurements in the overlay images based on the arterial und delayed venous phase (35.5+/-6.8 HU vs. 36.6+/-5.0 HU, P = 0.75). Metastases of colorectal carcinoma (51.4+/-9.4 HU vs. 32.5+/-8.9 HU, P = 0.0001), malignant melanoma (56.1+/-6.4 HU vs. 34.2+/-1.6 HU, P = 0.0045), and thyroid cancer (53.5+/-15.5 HU vs. 15.7+/-4.2 HU, P = 0.001) showed a distinct wash-out, whereas metastases of lung cancer (23.1+/-6.3 HU vs. 58.6+/-4.8 HU, P = 0.001), salivary gland cancer (41.4+/-20.3 HU vs. 65.7+/-15.7 HU, P = 0.023), and sarcoma (56.2+/-7.4 HU vs. 90.2+/-3.4 HU, P = 0.001) had an increased enhancement in the delayed venous phase. CONCLUSION: The contrast enhancement behavior of pulmonary metastases can be evaluated with DECT and depends on the type of the primary malignant tumor.


Subject(s)
Contrast Media , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/secondary , Multiple Pulmonary Nodules/diagnostic imaging , Multiple Pulmonary Nodules/secondary , Radiographic Image Enhancement , Tomography, X-Ray Computed , Adolescent , Adult , Female , Humans , Lung/diagnostic imaging , Male , Middle Aged , Prospective Studies , Young Adult
6.
Childs Nerv Syst ; 31(7): 1139-48, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25894756

ABSTRACT

PURPOSE: Spinal injuries are rarely seen in pediatric patients and therapeutic options are still poorly defined. The present study is aimed to present our experience with a rather large series of children and young adults suffering from traumatic spinal injury. PATIENTS AND METHODS: Between 1990 and 2010, 75 consecutive pediatric patients with spinal injuries were treated in our institution. Mean age was 15 years, ranging from 3 months to 21 years. Radiological findings, treatment strategies, and clinical outcome were evaluated retrospectively and compared with literature. Forty (53.3%) patients were treated conservatively and 35 patients (47%) surgically using anterior or posterior approaches. Subgroup analysis was performed depending on age groups, severity of neurological symptoms, and localization. RESULTS: Main trauma mechanisms were fall in 24 patients (38%) and motor vehicle accidents in 21 patients (28%). Complete neurological deficits were present in 17 individuals (23%) and incomplete in 36 patients (48%). Fractures were most frequently localized at the cervical region (56%) with predilection of the C 5/6 segment. Odontoid fractures were seen in 10 (13%) patients. Fractures of the lumbar and thoracic region were rare. Level of injury or clinical course did not differ between the subgroups (≤15 years versus >15 years). CONCLUSION: Nearly three fourths of all radiologically detected spinal injuries are located at the cervical spine. Complete neurological deficits after trauma was associated with a poor outcome, in particular for patients with injuries of the upper cervical spine. The use of autologous bone graft was associated with favorable long-term results and should be considered as the material of first choice for vertebral body and disc replacement.


Subject(s)
Disease Management , Spinal Injuries/diagnosis , Spinal Injuries/surgery , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Magnetic Resonance Imaging , Male , Neurologic Examination , Retrospective Studies , Tomography, X-Ray Computed , Young Adult
7.
Acta Radiol ; 56(5): 622-7, 2015 May.
Article in English | MEDLINE | ID: mdl-24867222

ABSTRACT

BACKGROUND: Magnetic resonance imaging (MRI) is an indispensable tool in the diagnostic work-up of multiple sclerosis (MS). To date, guidelines suggest MRI protocols containing axial dual-echo, unenhanced and post-contrast T1-weighted sequences. Especially the usage of dual-echo sequences has markedly improved the ability of MRI to detect cortical and infratentorial lesions. Newer 3D FLAIR sequences are supposed to provide even more positive imaging features such as improved detection of white matter lesions and a better resolution due to smaller slice thickness. PURPOSE: To evaluate the diagnostic impact of 3D FLAIR sequences in comparison to conventional T2 and PD sequences. MATERIAL AND METHODS: Examinations of 20 MS patients (10 women, 10 men) were reviewed retrospectively. All patients received MRI standard protocol containing PD and T2 sequences and a mid-sagittal T2 sequence. Additionally an isotropic 3D FLAIR sequence was performed. Whole-brain lesion load and number of lesions in juxtacortical, infratentorial, and midcallosal localizations were assessed by two observers independently and compared. RESULTS: Whole lesion load and the count of detectable lesions at the 3D FLAIR sequence were significantly higher in the juxtacortical and infratentorial regions compared to the PD/T2 sequence. Detection rate of midcallosal lesions did not differ significantly in sagittal T2 and 3D FLAIR sequence. CONCLUSION: 3D FLAIR sequences can improve the detection of brain lesions in patients with MS and are even more sensitive in depicting lesions in cortical and infratentorial locations than current dual-echo sequences. The sequence can replace both PD/T2 sequences and mid-sagittal T2 sequences of the corpus callosum.


Subject(s)
Brain/pathology , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Multiple Sclerosis/diagnosis , Adolescent , Adult , Female , Humans , Male , Middle Aged , Observer Variation , Retrospective Studies , Young Adult
8.
Acta Radiol ; 56(11): 1293-9, 2015 Nov.
Article in English | MEDLINE | ID: mdl-25398776

ABSTRACT

BACKGROUND: Depiction of the exact arterial liver anatomy as well as identifying potential extrahepatic non-target vessels is crucial for a successful preparation of radioembolization (RE). PURPOSE: To compare the diagnostic impact of dual-energy computed tomography (DECT) to digital subtraction angiography prior to RE. MATERIAL AND METHODS: DECT was applied in 46 patients with hepatocellular carcinoma (HCC) prior to RE. Eighty kV DE as well as reconstructed 120 kV equivalent DE datasets were evaluated in comparison to correlating digital subtraction angiography (DSA) datasets. Two radiologists evaluated in consensus the delineation of liver arteries and extrahepatic non-target vessels utilizing a 4-point scale (4 = excellent delineation; 1 = non-diagnostic). In addition, the arterial vascularization of liver segment IV was evaluated and classified: signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR; liver arteries to adjacent liver tissue) were obtained via ROI analysis. RESULTS: Both imaging techniques (DECT, DSA) enabled high-quality assessment of all analyzed liver arteries. Out of the two CT datasets, 80 kVp-DE datasets offered superior delineation of the right gastric artery (3.5 ± 0.7 vs. 2.5 ± 0.5), the vascularization of segment IV (3.9 ± 0.2 vs. 3.3 ± 0.5) as well as potential extrahepatic non-target vessels (3.9 ± 0.1 vs. 3.3 ± 0.5). In accordance to the results of the qualitative analysis, 80 kVp-DE datasets also yielded higher SNR (34.84 vs. 29.31) and CNR (28.29 vs. 21.8) values in comparison to the 120 kVp datasets. CONCLUSION: Eighty kVp DECT enables a significantly better assessment of the arteries of the upper abdomen for therapy planning in comparison to correlating 120 kVp datasets. This may allow for identification of potential extrahepatic non-target vessels and assessment of target volume for therapy planning prior to DSA.


Subject(s)
Angiography, Digital Subtraction , Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Liver/blood supply , Tomography, X-Ray Computed/methods , Aged , Angiography , Contrast Media , Embolization, Therapeutic/methods , Female , Humans , Iohexol/analogs & derivatives , Male , Middle Aged , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted/methods , Radiopharmaceuticals/therapeutic use , Signal-To-Noise Ratio
9.
J Comput Assist Tomogr ; 38(1): 25-8, 2014.
Article in English | MEDLINE | ID: mdl-24378887

ABSTRACT

OBJECTIVE: This study aimed to show the simulation of the radiation exposure of the brain during perfusion measurements multi-detector-CT. MATERIAL AND METHODS: The effective dose and different organ doses were measured with thermoluminescent dosimeters in an Alderson-Rando phantom and compared with the data of a simulation program (CT-Expo V1.6) for varying scan protocols with different tube voltages (in kilovolts) and constant parameters for tube current (270 mAs), scan length (28.8 mm), scan time (40 seconds), slice thickness (24 × 1.2 mm), and number of scans (40) for multi-detector-CT perfusion measurements of the brain. RESULTS: The thermoluminescent dosimeter measurements yielded effective doses of 3.8 mSv (80 kV), 8.6 mSv (100 kV), 14.1 mSv (120 kV), and 22.2 mSv (140 kV). These values were in line with the data from the simulation program CT-Expo V1.6. The organ doses varied between 97 and 556 mGy (brain), 10.7 and 80.9 mGy (eye lens), 9.6 and 46 mGy (bone marrow), 1.2 and 6.7 mGy (thyroid gland), and 4.1 to 22.3 mGy (skin). The maximum local skin dose ranged from 355 mGy (80 kV) to 1855 mGy (140 kV) in the directly exposed part of the skin. CONCLUSIONS: The radiation exposure during perfusion measurements of the brain is strongly dependent on the tube voltage and can vary widely even if the other exposure parameters remain constant. Maximum organ doses up to 556 mGy (brain) can be measured. Even if we never reached local organ doses that can cause a direct radiation injury, the review of the tube voltages implemented by the vendor is mandatory beside the limitation of the scanned area by clinical examination and the reduction of the number of scans. Simulation programs are a valuable tool for dose measurements.


Subject(s)
Brain/diagnostic imaging , Brain/radiation effects , Radiation Dosage , Tomography, X-Ray Computed/methods , Bone Marrow/radiation effects , Computer Simulation , Humans , Lens, Crystalline/radiation effects , Phantoms, Imaging , Skin/radiation effects , Thermoluminescent Dosimetry , Thyroid Gland/radiation effects
10.
World J Surg Oncol ; 11: 152, 2013 Jul 11.
Article in English | MEDLINE | ID: mdl-23845137

ABSTRACT

BACKGROUND: We are the first to report one-staged resection of a spinal metastasis from malignant cranial hemangiopericytoma after preoperative Onyx™-20 embolization by direct percutaneous puncture.Spinal metastases from cranial hemangiopericytoma are extremely rare. Surgical morbidity of these highly vascularized tumours results mainly from excessive blood loss. Preoperative embolization of hyper vascular tumours has been used to reduce intraoperative blood loss for a long time. To avoid complications from arterial catheter intervention, direct percutaneous puncture has been advocated as a safe and effective alternative. METHODS: A 46-year-old man with a history of malignant cranial hemangiopericytoma deriving from the left frontal skull base presented with a short history of lower back pain. A magnetic resonance imaging scan revealed an intra- and extra spinal mass lesion of the thoracic spine at Th 12. Indication for tumour resection was made and the patient's written consent was obtained. Preoperatively, arterial catheter angiography was performed to reveal the tumour's angioarchitecture, revealing high-flow arteriovenous shunts. In order to impede the expected perioperative blood loss, tumour embolization by direct percutaneous puncture and application of Onyx™-20 was performed prior to surgery. RESULTS: After percutaneous Onyx™-20 embolization, complete and safe resection of the lesion could be achieved. There was only minimal blood loss perioperatively. A pathohistological report confirmed malignant, anaplastic hemangiopericytoma. CONCLUSIONS: In our case Onyx™-20 embolization via direct percutaneous puncture of a highly vascularized tumour was shown to be a safe and efficient tool prior to surgery. Despite high-flow arteriovenous shunts, direct percutaneous administration of non-adhesive ethanol liquid was an efficient alternative to transarterial catheter embolization. The perioperative blood loss could be substantially diminished.


Subject(s)
Contrast Media/administration & dosage , Embolization, Therapeutic/methods , Hemangiopericytoma/pathology , Meningeal Neoplasms/pathology , Polyvinyls/administration & dosage , Spinal Neoplasms/secondary , Tantalum/administration & dosage , Drug Combinations , Hemangiopericytoma/surgery , Hemangiopericytoma/therapy , Humans , Magnetic Resonance Imaging , Male , Meningeal Neoplasms/surgery , Meningeal Neoplasms/therapy , Middle Aged , Preoperative Care , Prognosis , Spinal Neoplasms/surgery , Spinal Neoplasms/therapy
11.
Invest Radiol ; 58(10): 754-765, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37222527

ABSTRACT

OBJECTIVES: In multiple myeloma and its precursor stages, plasma cell infiltration (PCI) and cytogenetic aberrations are important for staging, risk stratification, and response assessment. However, invasive bone marrow (BM) biopsies cannot be performed frequently and multifocally to assess the spatially heterogenous tumor tissue. Therefore, the goal of this study was to establish an automated framework to predict local BM biopsy results from magnetic resonance imaging (MRI). MATERIALS AND METHODS: This retrospective multicentric study used data from center 1 for algorithm training and internal testing, and data from center 2 to 8 for external testing. An nnU-Net was trained for automated segmentation of pelvic BM from T1-weighted whole-body MRI. Radiomics features were extracted from these segmentations, and random forest models were trained to predict PCI and the presence or absence of cytogenetic aberrations. Pearson correlation coefficient and the area under the receiver operating characteristic were used to evaluate the prediction performance for PCI and cytogenetic aberrations, respectively. RESULTS: A total of 672 MRIs from 512 patients (median age, 61 years; interquartile range, 53-67 years; 307 men) from 8 centers and 370 corresponding BM biopsies were included. The predicted PCI from the best model was significantly correlated ( P ≤ 0.01) to the actual PCI from biopsy in all internal and external test sets (internal test set: r = 0.71 [0.51, 0.83]; center 2, high-quality test set: r = 0.45 [0.12, 0.69]; center 2, other test set: r = 0.30 [0.07, 0.49]; multicenter test set: r = 0.57 [0.30, 0.76]). The areas under the receiver operating characteristic of the prediction models for the different cytogenetic aberrations ranged from 0.57 to 0.76 for the internal test set, but no model generalized well to all 3 external test sets. CONCLUSIONS: The automated image analysis framework established in this study allows for noninvasive prediction of a surrogate parameter for PCI, which is significantly correlated to the actual PCI from BM biopsy.


Subject(s)
Deep Learning , Multiple Myeloma , Male , Humans , Middle Aged , Multiple Myeloma/diagnostic imaging , Multiple Myeloma/genetics , Bone Marrow/diagnostic imaging , Retrospective Studies , Magnetic Resonance Imaging/methods , Biopsy , Chromosome Aberrations
12.
Clin Neuroradiol ; 32(4): 961-969, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35294573

ABSTRACT

PURPOSE: Despite improved techniques and sophisticated postinterventional care, symptomatic intracranial hemorrhage (sICH) remains the most feared complication of mechanical thrombectomy (MT). Based on peri-interventional parameters, we aimed to discover which patients have a higher risk of sICH. METHODS: From March 2017 until March 2020 consecutive patients with acute ischemic stroke (AIS) and confirmed large-vessel occlusion who underwent MT were analyzed retrospectively. Demographic, clinical, and radiological variables and parameters specific to thrombectomy were reviewed. A univariate analysis was performed and statistically significant variables were included in a logistic regression model to identify independent factors predictive of sICH. RESULTS: A total of 236 patients with confirmed large-vessel occlusion were included and 22 (9.3%) had sICH. Univariate predictors of sICH included diabetes mellitus, glucose > 11.1 mmol/L, creatinine clearance (CrCl) ≤ 30 ml/min/1.73, ASPECTS indicating pretreatment infarct size, acute internal carotid artery (ICA) occlusion, stent implantation, tirofiban use, time from symptom onset to groin puncture > 4.5 h and high contrast medium consumption. In the adjusted analysis, ASPECTS < 6 (OR 3.673, p = 0.041), and amount of contrast injected ≥ 140 ml (OR 5.412, p = 0.003) were independent predictors of sICH, but not any more baseline glucose > 11.1 mmol/L (OR 1.467, p = 0.584), CrCl ≤ 30 ml/min/1.73 (OR 4.177, p = 0.069), acute ICA occlusion (OR 2.079, p = 0.181), stent implantation (OR 0.465, p = 0.512), tirofiban use (OR 5.164, p = 0.167), and time from onset-to-groin puncture (OR 1.453, p = 0.514). CONCLUSION: The amount of contrast medium used is a modifiable factor associated with sICH. This association is novel and may be related to the neurotoxicity of the contrast medium disrupting the blood-brain barrier.


Subject(s)
Arterial Occlusive Diseases , Brain Ischemia , Ischemic Stroke , Stroke , Humans , Brain Ischemia/etiology , Stroke/etiology , Retrospective Studies , Ischemic Stroke/complications , Treatment Outcome , Intracranial Hemorrhages/diagnostic imaging , Intracranial Hemorrhages/etiology , Thrombectomy/adverse effects , Thrombectomy/methods , Arterial Occlusive Diseases/complications , Glucose
13.
J Neurointerv Surg ; 14(9): 858-862, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35292572

ABSTRACT

BACKGROUND: Data on the frequency and outcome of mechanical thrombectomy (MT) for large vessel occlusion (LVO) in patients with COVID-19 is limited. Addressing this subject, we report our multicenter experience. METHODS: A retrospective cohort study was performed of consecutive acute stroke patients with COVID-19 infection treated with MT at 26 tertiary care centers between January 2020 and November 2021. Baseline demographics, angiographic outcome and clinical outcome evaluated by the modified Rankin Scale (mRS) at discharge and 90 days were noted. RESULTS: We identified 111 out of 11 365 (1%) patients with acute or subsided COVID-19 infection who underwent MT due to LVO. Cardioembolic events were the most common etiology for LVO (38.7%). Median baseline National Institutes of Health Stroke Scale score and Alberta Stroke Program Early CT Score were 16 (IQR 11.5-20) and 9 (IQR 7-10), respectively. Successful reperfusion (mTICI ≥2b) was achieved in 97/111 (87.4%) patients and 46/111 (41.4%) patients were reperfused completely. The procedure-related complication rate was 12.6% (14/111). Functional independence was achieved in 20/108 (18.5%) patients at discharge and 14/66 (21.2%) at 90 days follow-up. The in-hospital mortality rate was 30.6% (33/108). In the subgroup analysis, patients with severe acute COVID-19 infection requiring intubation had a mortality rate twice as high as patients with mild or moderate acute COVID-19 infection. Acute respiratory failure requiring ventilation and time interval from symptom onset to groin puncture were independent predictors for an unfavorable outcome in a logistic regression analysis. CONCLUSION: Our study showed a poor clinical outcome and high mortality, especially in patients with severe acute COVID-19 infection undergoing MT due to LVO.


Subject(s)
Brain Ischemia , COVID-19 , Ischemic Stroke , Stroke , Brain Ischemia/complications , Brain Ischemia/diagnostic imaging , Brain Ischemia/therapy , COVID-19/complications , Humans , Ischemic Stroke/diagnostic imaging , Ischemic Stroke/surgery , Retrospective Studies , Stroke/diagnostic imaging , Stroke/etiology , Stroke/surgery , Thrombectomy/adverse effects , Treatment Outcome
14.
Eur Radiol ; 21(4): 738-43, 2011 Apr.
Article in English | MEDLINE | ID: mdl-20936520

ABSTRACT

OBJECTIVE: To investigate dual-energy CT of hypervascular liver lesions in patients with HCC. METHODS: Forty patients with hepatocellular carcinomas were investigated with abdominal dual-energy CT. In each patient unenhanced and contrast-enhanced imaging with arterial und portovenous delay were performed. Hypervascular lesions were documented on arterial phase 80-kVp images, 140-kVp images, and the averaged arterial images by two radiologists. Subjective image quality (5-point scale, from 5 [excellent] to 1 [not interpretable]) was rated on all images. RESULTS: The mean number of hypervascular HCC lesions detected was 3.37 ± 1.28 on 80-kVp images (p < 0.05), 1.43 ± 1.13 on 140-kVp images (p < 0.05), and 2.57 ± 1.2 on averaged images. The image quality was 0.3 ± 0.5 for 80-kVp (p < 0.05), 1.6 ± 0.5 for 140-kVp (p < 0.05) and 3.2 ± 0.4 for the averaged images. CONCLUSION: Low-kVp images of dual-energy datasets are more sensitive in detecting hypervascular liver lesions. However, this increase in sensitivity goes along with a decrease in the subjective image quality of low-kVp images.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Image Processing, Computer-Assisted/methods , Liver Neoplasms/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Radiology/methods , Tomography, X-Ray Computed/methods , Aged , Contrast Media/pharmacology , Female , Humans , Liver/diagnostic imaging , Liver/pathology , Male , Middle Aged , Radiography, Abdominal/methods , Sensitivity and Specificity
15.
Cerebrovasc Dis ; 31(6): 580-7, 2011.
Article in English | MEDLINE | ID: mdl-21487223

ABSTRACT

BACKGROUND: The clinical response to systemic thrombolysis with recombinant tissue plasminogen activator (rtPA) is thought to depend on an early recanalization. We sought to investigate the effect of early recanalization on stroke lesion development as assessed with magnetic resonance imaging (MRI). METHODS: Thirty-seven consecutive stroke patients (66 ± 13 years) treated with systemic thrombolysis with rtPA and tirofiban were grouped according to successful or failed recanalization as assessed on angiographic imaging. Infarct lesions were determined volumetrically in MRI prior to treatment and after 4 days. RESULTS: Patients were severely affected (median National Institutes of Health Stroke Scale 14) and had significantly larger perfusion (PWI) than diffusion weighted imaging (DWI) lesion volumes. Ten patients with failed recanalization of the internal carotid or the middle cerebral artery did not improve. Their PWI and DWI lesion volumes were larger and the apparent diffusion coefficient more depressed than in the 27 patients with significant improvement and successful recanalization (p < 0.001). The DWI lesion volumes increased profoundly in the patients with failed recanalization (p < 0.001) but only little in the patients with successful recanalization. Multivariate regression analysis showed a relation of the initial DWI lesion volumes to the DWI lesion volumes at follow-up and the neurological recovery. CONCLUSIONS: The ischemic brain damage was particularly severe in patients with no recanalization already before systemic thrombolysis and predicted further lesion growth and failed recovery.


Subject(s)
Diffusion Magnetic Resonance Imaging , Stroke/drug therapy , Stroke/pathology , Thrombolytic Therapy/methods , Tissue Plasminogen Activator/administration & dosage , Tyrosine/analogs & derivatives , Aged , Brain Ischemia/drug therapy , Brain Ischemia/pathology , Female , Fibrinolytic Agents/administration & dosage , Follow-Up Studies , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Recovery of Function/drug effects , Severity of Illness Index , Tirofiban , Treatment Failure , Tyrosine/administration & dosage
16.
J Med Case Rep ; 15(1): 83, 2021 Feb 23.
Article in English | MEDLINE | ID: mdl-33618738

ABSTRACT

BACKGROUND: The risk of stroke after carotid sinus massage is greater if there is preexisting carotid stenosis or carotid plaques. We present the case of a patient with underlying 40% carotid stenosis, who developed a watershed stroke after a self-neck massage in our stroke unit. We show a well-documented case with magnetic resonance images before and after the neck massage. We report a case of a watershed brain infarct after a self-massage of the carotid sinus, with preexisting carotid artery stenosis. Neck massage continues to be a significant cause of stroke and should therefore not be performed by patients. Clinicians must be aware of the implications of a carotid sinus massage in both the outpatient and inpatient settings. CASE PRESENTATION: We admitted a 58-year-old white male patient, with no relevant medical history, to our department with a brain stem infarct. During his stay at our stroke unit, the patient performed a self-neck massage with consecutive bradycardia and asystole, resulting in left-side hemiparesis. The underlying cause of the hemodynamic stroke is believed to be secondary to this intensive neck massage performed by the patient. The patient also suffered from unknown right internal carotid artery stenosis. CONCLUSION: Clinicians and patients must be aware that neck massage can lead to ischemic stroke. We postulate that repetitive impaired cardiac output can lead to a hemodynamic (watershed-type) stroke.


Subject(s)
Brain Ischemia/etiology , Carotid Sinus , Ischemic Stroke/etiology , Massage/adverse effects , Brain Stem Infarctions/etiology , Carotid Stenosis/diagnostic imaging , Electrocardiography , Humans , Magnetic Resonance Imaging , Male , Middle Aged
17.
AJR Am J Roentgenol ; 194(3): 794-8, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20173162

ABSTRACT

OBJECTIVE: The purpose of our study was to compare the image quality of free-breathing ECG-gated nonenhanced steady-state free precession (SSFP) MR angiography of renal arteries at 1.5 T and 3 T. SUBJECTS AND METHODS: Twenty volunteers (11 men, nine women; mean age, 23.2 +/- 2.3 years) without a history of renovascular disease participated in the study. Nonenhanced SSFP MR angiography was performed on all subjects at both 1.5 T and 3 T with a maximum interval of 2 weeks between the imaging sessions. The subjective image quality of axial and coronal maximum-intensity-projection reconstructions of four segments (1, abdominal aorta and ostium of renal artery; 2, main renal artery; 3, segmental branches outside renal parenchyma; 4, segmental branches inside renal parenchyma) was evaluated independently by two radiologists using a 4-point scale (4, excellent; 1, nondiagnostic). Relative signal-to-noise ratio, contrast-to-noise ratio, and maximum visible vessel length of the right and left renal arteries also were determined. RESULTS: No significant difference in image quality at 1.5 T and 3 T was found for segments 1 and 2. The mean image quality for segments 3 and 4 was significantly greater at 3 T (3.88 +/- 0.32, 3.17 +/- 0.70) than at 1.5 T (3.32 +/- 0.73, 2.09 +/- 0.81) (p < 0.001). At 3 T, the maximal vessel length of the right (9.85 +/- 0.82 cm) and left (8.3 +/- 0.79 cm) renal arteries was significantly greater than at 1.5 T (8.94 +/- 1.38 cm and 7.58 +/- 1.18 cm, respectively). CONCLUSION: Performing nonenhanced SSFP MR angiography at 3 T significantly improves visualization of peripheral renal arterial segments in healthy subjects as compared to 1.5 T.


Subject(s)
Imaging, Three-Dimensional , Magnetic Resonance Angiography/methods , Renal Artery/anatomy & histology , Electrocardiography , Humans , Male , Statistics, Nonparametric , Young Adult
18.
Biomed Res Int ; 2020: 2721381, 2020.
Article in English | MEDLINE | ID: mdl-32884938

ABSTRACT

INTRODUCTION: Emergency department (ED) triage regarding infection with severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is challenging. During the coronavirus disease 2019 (COVID-19) outbreak in Germany, the diagnostic outcomes of critically ill patients admitted to the resuscitation room in the ED of our academic 754-bed hospital should be analyzed. METHODS: All resuscitation room patients between March 1st and April 15th 2020 were included in this retrospective study. Every patient with suspicion of SARS-CoV-2 infection received a pharyngeal swab for real-time polymerase chain reaction (rt-PCR), divided in the clinical subgroups of "highly suspicious for COVID-19" and "COVID-19 as differential diagnosis." All respiratory and infectious symptoms were included as at least "differential diagnosis" as an expanded suspicion strategy. RESULTS: Ninety-five patients were included (trauma n = 14, critically ill n = 81). Of 3 highly suspicious patients, 2 had rt-PCR positive pharyngeal swabs. In 39 patients, COVID-19 was defined as differential diagnosis, and 3 were positive for SARS-CoV-2. Of them, pharyngeal swabs were positive in 1 case, while in 2 cases, only tracheal fluid was rt-PCR positive while the pharyngeal swabs were negative. In one of these 2 cases, chest computed tomography (CT) was also negative for ground-glass opacities but showed a pulmonary abscess and pulmonary embolism. CONCLUSION: We recommend an expanded suspicion strategy for COVID-19 due to unexpected diagnostic outcomes. Personal protective equipment should be used in every resuscitation room operation due to unexpected cases and initial knowledge gaps. Furthermore, tracheal fluid should be tested for SARS-CoV-2 in every intubated patient due to cases with negative pharyngeal swabs and negative chest CT.


Subject(s)
Betacoronavirus , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Aged , Aged, 80 and over , COVID-19 , COVID-19 Testing , COVID-19 Vaccines , Coronavirus Infections/diagnostic imaging , Coronavirus Infections/epidemiology , Critical Illness , Diagnosis, Differential , Disease Outbreaks , Emergency Service, Hospital , False Negative Reactions , Female , Germany/epidemiology , Humans , Male , Middle Aged , Pandemics , Pneumonia, Viral/diagnostic imaging , Pneumonia, Viral/epidemiology , RNA, Viral/genetics , RNA, Viral/isolation & purification , Real-Time Polymerase Chain Reaction , Resuscitation , Retrospective Studies , SARS-CoV-2 , Tomography, X-Ray Computed , Triage
19.
Ther Adv Neurol Disord ; 13: 1756286420911295, 2020.
Article in English | MEDLINE | ID: mdl-32313555

ABSTRACT

BACKGROUND: The present study evaluates the possible prognostic benefits of 7 T susceptibility weighted imaging (SWI) of traumatic cerebral microbleeds (TMBs) over 3 T SWI to predict the acute clinical state and subjective impairments, including health-related quality of life (HRQOL), after closed head injury (CHI). METHODS: The study group comprised 10 participants with known TMBs All subjects underwent 3 T magnetic resonance imaging (MRI) and 7 T MRI, respectively. Location and count of TMBs were independently evaluated by two neuroradiologists. The initial Glasgow Coma Scale (GCS), the duration of coma and further clinical data were taken from the patients records. HRQOL was assessed by means of a questionnaire. Memory complaints and neurological symptoms were inquired at the time of the MRI examinations. RESULTS: SWI revealed a total of 485 TMBs at 3 T, 584 TMBs at 7 T with similar spatial resolution, and 684 TMBs at 7 T with a factor of 10 higher spatial resolution. The TMBs depicted by 7 T high-resolution SWI were correlated with the duration of coma (Spearman's rho of 0.77). The corresponding association with TMBs in 3 T MRI SWI showed a Spearman's rho of 0.71. The initial GCS score and TMBs correlated with a Spearman's rho of -0.35 at 3 T SWI MRI and a rho of -0.33 at 7 T high-resolution SWI, respectively. The physical aspect of HRQOL correlated substantially with the count of TMBs (rho = 0.44 for 3 T SWI and rho = 0.35 for both 7 T SWI sequences, respectively). CONCLUSIONS: The number of TMBs showed a substantial association with indicators of the acute clinical state and chronic neurobehavioral parameters after CHI, but there was no additional advantage of 7 T MRI. These preliminary findings warrant a larger prospective study for the future.

20.
Radiology ; 252(3): 914-21, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19635833

ABSTRACT

PURPOSE: To evaluate noncontrast material-enhanced steady-state free precession (SSFP) magnetic resonance (MR) angiography in the assessment of transplant renal arteries (RAs) by using digital subtraction angiography (DSA) as the reference standard. MATERIALS AND METHODS: This prospective study was approved by the institutional review board; written informed consent was obtained from all participants. In 20 renal allograft recipients scheduled for DSA, the transplant RAs were assessed with electrocardiographically gated nonenhanced SSFP MR angiography performed at 1.5 T; the degree of stenosis was compared with that of DSA. Subjective image quality for SSFP MR angiography was assessed independently by two radiologists on a four-point scale (from 1, nondiagnostic to 4, excellent) in four predefined segments (I, the iliac artery; II, the main transplant artery; III, segmental branches; and IV, parenchymal branches). Sensitivity, specificity, and accuracy of SSFP MR angiography for the detection of relevant (> or =50%) transplant RA stenosis (TRAS) were calculated on a per-artery basis. RESULTS: One patient was excluded because SSFP MR angiography failed to adequately visualize the allograft vasculature owing to low cardiac output. The mean image quality assessed by both readers was 3.98 +/- 0.16 (standard deviation), 3.5 +/- 0.68, 2.71 +/- 1.12 and 2.03 +/- 1.09 for segments I, II, III, and IV, respectively (kappa = 0.80). DSA helped identify eight relevant (> or =50%) stenoses in six transplant RAs. Kinking of the transplant artery without relevant stenosis was found in seven patients. The degree of stenosis was overestimated in three patients by using SSFP MR angiography. As compared with DSA, the sensitivity, specificity, and accuracy of SSFP MR angiography to help detect relevant TRAS were 100% (six of six), 88% (14 of 16), and 91% (20 of 22), respectively. CONCLUSION: Nonenhanced SSFP MR angiography is a reliable alternative imaging technique for the assessment of transplant RAs in patients for whom contrast-enhanced MR angiography is contraindicated.


Subject(s)
Electrocardiography , Imaging, Three-Dimensional , Kidney Transplantation , Kidney/blood supply , Magnetic Resonance Angiography/methods , Renal Artery Obstruction/diagnosis , Adult , Angiography, Digital Subtraction , Female , Humans , Image Interpretation, Computer-Assisted , Kidney/diagnostic imaging , Male , Middle Aged , Prospective Studies , Renal Artery , Renal Artery Obstruction/diagnostic imaging , Sensitivity and Specificity , Transplantation, Homologous , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL