Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Clin Oral Investig ; 28(7): 370, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38869624

ABSTRACT

OBJECTIVES: To investigate the effect of multiple firings on color, translucency, and biaxial flexure strength of Virgilite-containing (Li0.5Al0.5Si2.5O6) lithium disilicate glass ceramics of varying thickness. MATERIALS AND METHODS: Sixty discs were prepared from Virgilite-containing lithium disilicate blocks. Discs were divided according to thickness (n = 30) into T0.5 (0.5 mm) and T1.0 (1.0 mm). Each thickness was divided according to the number of firing cycles (n = 10); F1 (Control group): 1 firing cycle; F3: 3 firing cycles, and F5: 5 firing cycles. The discs were tested for color change (ΔE00) and translucency (TP00) using a spectrophotometer. Then, all samples were subjected to biaxial flexure strength testing using a universal testing machine. Data were collected and statistically analyzed (α = 0.5). For chemical analysis, six additional T0.5 discs (2 for each firing cycle) were prepared; for each firing cycle one disc was subjected to X-ray diffraction analysis (XRD) and another disc was subjected to Energy dispersive X-ray spectroscopy (EDX) and Scanning electron microscope (SEM). RESULTS: Repeated firing significantly reduced the translucency of F3 and F5 compared to F1 in T0.5 (p < 0.001), while for T1.0 only F5 showed a significant decrease in TP00 (p < 0.001). For ΔE00, a significant increase was recorded with repeated firings (p < 0.05) while a significant decrease resulted in the biaxial flexure strength regardless of thickness. CONCLUSIONS: Repeated firings had a negative effect on both the optical and mechanical properties of the Virgilite-containing lithium disilicate glass ceramics. CLINICAL RELEVANCE: Repeated firings should be avoided with Virgilite-containing lithium disilicate ceramics to decrease fracture liability and preserve restoration esthetics.


Subject(s)
Ceramics , Dental Porcelain , Flexural Strength , Materials Testing , Surface Properties , X-Ray Diffraction , Ceramics/chemistry , Dental Porcelain/chemistry , Color , Dental Stress Analysis , Spectrophotometry , Microscopy, Electron, Scanning , Hot Temperature
2.
BMC Oral Health ; 24(1): 307, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38443910

ABSTRACT

STATEMENT OF PROBLEM: CAD/CAM occlusal veneers have been developed for minimally invasive prosthetic restoration of eroded teeth. Marginal adaptation and fracture resistance are crucial for the long-term survivability and clinical success of such restorations. Virgilite-based lithium disilicate glass-ceramic is a newly introduced material with claims of high strength. However, constructing occlusal veneers from this material of varying thickness has not been investigated. PURPOSE: The current study aimed to assess the impact of CAD/CAM occlusal veneer thickness and materials on marginal adaptation and fracture resistance. MATERIALS AND METHODS: Thirty-two occlusal veneers were constructed and divided into two groups (n = 16) based on the CAD/CAM material into Brilliant Crios and CEREC Tessera. Each group was further subdivided into two subgroups (n = 8) according to the thickness: 0.6 and 0.9 mm. Occlusal veneers were bonded to epoxy resin dies. The marginal gap was evaluated before and after thermodynamic aging. Fracture resistance and failure mode were evaluated for the same samples after aging. Marginal adaptation was analyzed using the Mann-Whitney U test. Fracture resistance was analyzed using Weibull analysis (α = 0.05). RESULTS: The marginal gap was significantly increased following thermodynamic aging for tested groups (P < 0.001). CEREC Tessera showed a significantly higher marginal gap than Brilliant Crios before and after aging for both thicknesses (P < 0.05). CEREC Tessera recorded lower significant fracture load values compared to Brilliant Crios (P < 0.05). CONCLUSIONS: Both CEREC Tessera and Brilliant Crios demonstrated clinically accepted marginal gap values. All groups showed fracture resistance values higher than the average masticatory forces in the premolar region except for 0.6 mm CEREC Tessera. CLINICAL IMPLICATIONS: Reinforced composite occlusal veneers demonstrated more favorable outcomes in terms of marginal gap and fracture resistance at both tested thicknesses compared to virgilite-based lithium disilicate glass-ceramic. Additionally, caution should be exercised during the construction of occlusal veneers from virgilite-based lithium disilicate glass-ceramic with reduced thickness.


Subject(s)
Aging , Bite Force , Humans , Computer-Aided Design , Epoxy Resins , Statistics, Nonparametric
3.
Dent Med Probl ; 2024 Aug 08.
Article in English | MEDLINE | ID: mdl-39115543

ABSTRACT

BACKGROUND: The durability of indirect restorations is significantly influenced by marginal adaptation and internal fit. The use of computer-aided design/computer-aided manufacturing (CAD/CAM) with digital impressions has reduced dental prosthesis fabrication errors, improving the long-term survivability of the restorations. OBJECTIVES: The present study assessed the impact of intraoral and extraoral scanning methods on the marginal adaptation and internal fit of 2 different types of monolithic crowns manufactured using CAD/CAM. MATERIAL AND METHODS: A total of 40 three-dimensional (3D) resin-printed dies were randomly assigned to 2 groups based on the type of crown material (n = 20 per group). Each group was divided into 2 subgroups (n = 10 per group) according to the die-scanning technique: subgroup A, scanned using the intraoral scanner (IOS) Primescan; and subgroup B, scanned using the extraoral scanner (EOS) inEos X5. The digitized photos were converted into a 3D virtual crown design using CAD software. The internal discrepancy values, and the marginal gap between the 3D resin-printed die and the crown were assessed using a ×50 digital microscope. The data was checked for normality with the Kolmogorov-Smirnov test, and the Mann-Whitney U test was used to compare the tested groups. The collected data was analyzed at a significance level set at p < 0.05. RESULTS: The different scanning techniques used had a statistically significant effect on the vertical marginal gap and the internal fit [µm] (p < 0.05). As far as the crown materials are concerned, BRILLIANT Crios showed a significantly higher marginal gap as compared to Tetric CAD when scanned with inEos X5 (p = 0.004), whereas the differences were insignificant with regard to the internal fit (p > 0.05).The crown parameters tested with both scanning systems were within the clinically acceptable ranges. CONCLUSIONS: Scanning methods and crown materials had an impact on the internal fit and vertical marginal gap of monolithic crowns.

4.
Eur J Surg Oncol ; 50(3): 108019, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38359725

ABSTRACT

BACKGROUND: Mediastinal Yolk sac tumors (YST) are rare and highly malignant extragonadal germ cell tumors with rapid growth and early metastases. We sought to conduct a meta-analysis of published case reports/case series to compare differences in survival, demographics, and treatment modalities between adult and pediatric patients with YST. METHODS: Ovid Embase, Cochrane, and Ovid Medline databases were searched for primary mediastinal pure YST cases. The primary outcome was overall survival (OS). Log-rank and Cox regression were used. This study is registered on PROSPERO (CRD42022367586). RESULTS: Among 846 studies, 87 met our inclusion criteria including 130 patients (Adults: 90 and Pediatrics: 40). About 41.5% of the patients were from the United States. The median age was 23.0 (Q1-Q3: 17.0-30.0), 88.5% were males, and (32.3%) were Asian. Stage II represented almost 40%. AFP was elevated in 96.9%. Respiratory distress was the presenting symptom in 65.4%. Chemotherapy, radiotherapy, and surgery were utilized in 84.6, 23.1, and 64.7% respectively. Median OS was 24 months (Adults: 23 months, Pediatrics: 25 months, P = 0.89). 3- and 5-year OS were 34.4% and 22.9% in adults and 41.5% and 41.5% in pediatrics, respectively. On multivariate analysis, anterior location of tumors, receipt of chemotherapy, and undergoing surgery were associated with better OS. CONCLUSION: Primary mediastinal YSTs are rare, but lethal neoplasms. Our meta-analysis showed that mediastinal YSTs mimic other non-seminomatous mediastinal GCTs in terms of clinical characteristics and available treatment options. Early diagnosis, neoadjuvant chemotherapy, and surgical resection are the key points for effective management and improved outcomes.


Subject(s)
Endodermal Sinus Tumor , Mediastinal Neoplasms , Neoplasms, Germ Cell and Embryonal , Male , Adult , Humans , Child , Young Adult , Female , Endodermal Sinus Tumor/drug therapy , Endodermal Sinus Tumor/pathology , Mediastinal Neoplasms/therapy , Mediastinal Neoplasms/pathology , Mediastinum/pathology , Neoadjuvant Therapy
SELECTION OF CITATIONS
SEARCH DETAIL