ABSTRACT
BACKGROUND: This study aimed to describe the perinatal outcome and central nervous system (CNS) anomalies in fetuses undergoing red blood cell (RBC) intrauterine transfusion (IUT). METHODS AND MATERIALS: This was an observational single-cohort study carried out at Vall d'Hebron University Hospital in Barcelona, Spain, between 2002 and 2018 in women undergoing RBC IUT for suspected fetal anemia. Primary outcomes were adverse perinatal outcome (intrauterine or neonatal death and termination of pregnancy [TOP]), prenatal or postnatal CNS anomalies, and significant neurological impairment. RESULTS: A total of 145 RBC transfusions were performed in 68 pregnancies of 60 women. The median gestational age for the first transfusion was 26 weeks (range, 18-32). Twenty-two (32%) fetuses were hydropic at the first transfusion. Fifty-eight pregnancies (85.3%) resulted in live births and 10 (14.7%) in adverse perinatal outcomes. Adverse perinatal outcomes were associated with hydrops (odds ratio [OR], 6.69; 95% confidence interval [CI], 1.53-29.23; P = .012) and gestational age at first transfusion (OR, 0.69; 95% CI, 0.54-0.89; P = .04). Four (5.9%) cases of cerebellar hemorrhage were diagnosed prenatally. In 14 (35%) of the 41 neonates undergoing brain ultrasound and/or magnetic resonance imaging (MRI) abnormalities were reported. The median follow-up was 6.5 years (range, 3 months to 19 years). Significant neurological impairment was reported in two cases (4.2%). CONCLUSION: In fetuses undergoing intrauterine RBC transfusion, the survival rate is high, particularly in the absence of hydrops and if the gestational age at first transfusion is above 22 weeks. Significant neurological impairment is uncommon, despite the fact that postnatal CNS anomalies at ultrasound or MRI are frequent.
Subject(s)
Anemia , Blood Transfusion, Intrauterine/adverse effects , Erythrocyte Transfusion/adverse effects , Fetal Diseases , Nervous System Malformations , Transfusion Reaction/mortality , Adolescent , Adult , Anemia/mortality , Anemia/therapy , Female , Fetal Diseases/mortality , Fetal Diseases/therapy , Gestational Age , Humans , Nervous System Malformations/etiology , Nervous System Malformations/mortality , Pregnancy , Retrospective Studies , Tertiary Care CentersSubject(s)
Anemia, Aplastic/blood , Blood Specimen Collection , Hemolysis , Plasma/metabolism , Adult , Female , HumansABSTRACT
BACKGROUND: Prematurity is a significant health issue due to its incidence and associated complications. Anemia is common in extremely preterm infants (EPI) and often requires transfusions. Red blood cells (RBC) from adult blood (AB) donors have been linked to oxygen-related complications in EPI, leading to the exploration of cord blood (CB) as an alternative source. However, standardization of CB-RBC manufacturing and comparison with AB-RBC characteristics are necessary before clinical studies can be conducted. MATERIALS AND METHODS: This study investigated the quality and characteristics of leukoreduced, gamma-irradiated CB-RBC obtained using a commercial closed system from CB donations not meeting hematopoietic transplantation criteria. CB-RBC units were compared with AB-RBC units, both stored in saline-adenine-glucose-mannitol (SAGM). Various parameters, including hematological and biochemical characteristics, pH, 2,3-DPG levels, blood gases and potential toxicants, were evaluated during storage. RESULTS: CB-RBC units had acceptable initial quality parameters and a hematocrit (55±2%) comparable to AB-RBC. The main finding during storage was a faster rise in hemolysis compared to AB-RBC. Potassium (K+) significantly increased during storage in both sources. As expected, glucose levels decreased, and conversely, lactate levels increased, indicating similar patterns of anaerobic glycolysis during storage. pH decreased, affecting the oxygen dissociation curve due to reduced 2,3-DPG levels. After irradiation at 14 days of storage, CB-RBC were less stable as hemolysis and K+ significantly increased compared to AB-RBC at 24 hours. Phthalate concentrations, indicative of plasticizers, increased during storage, but significantly less in CB compared to AB-RBC. Most metals measured were within acceptable ranges. DISCUSSION: The quality of CB-RBC during storage is primarily influenced by levels of hemolysis and extracellular K+ content. Based on the analyzed parameters, we suggest that the expiration date for CB-RBC stored with SAGM should be set at 14 days, with transfusion occurring within <24 hours after irradiation.