Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
J Bacteriol ; 201(16)2019 08 15.
Article in English | MEDLINE | ID: mdl-31209076

ABSTRACT

Previous work from our group indicated an association between the gastrointestinal microbiota of infants with cystic fibrosis (CF) and airway disease in this population. Here we report that stool microbiota of infants with CF demonstrates an altered but largely unchanging within-individual bacterial diversity (alpha diversity) over the first year of life, in contrast to the infants without CF (control cohort), which showed the expected increase in alpha diversity over the first year. The beta diversity, or between-sample diversity, of these two cohorts was significantly different over the first year of life and was statistically significantly associated with airway exacerbations, confirming our earlier findings. Compared with control infants, infants with CF had reduced levels of Bacteroides, a bacterial genus associated with immune modulation, as early as 6 weeks of life, and this significant reduction of Bacteroides spp. in the cohort with CF persisted over the entire first year of life. Only two other genera were significantly different across the first year of life: Roseburia was significantly reduced and Veillonella was significantly increased. Other genera showed differences between the two cohorts but only at selected time points. In vitro studies demonstrated that exposure of the apical face of polarized intestinal cell lines to Bacteroides species supernatants significantly reduced production of interleukin 8 (IL-8), suggesting a mechanism whereby changes in the intestinal microbiota could impact inflammation in CF. This work further establishes an association between gastrointestinal microbiota, inflammation, and airway disease in infants with CF and presents a potential opportunity for therapeutic interventions beginning in early life.IMPORTANCE There is growing evidence for a link between gastrointestinal bacterial communities and airway disease progression in CF. We demonstrate that infants with CF ≤1 year of age show a distinct stool microbiota versus that of control infants of a comparable age. We detected associations between the gut microbiome and airway exacerbation events in the cohort of infants with CF, and in vitro studies provided one possible mechanism for this observation. These data clarify that current therapeutics do not establish in infants with CF a gastrointestinal microbiota like that in healthy infants, and we suggest that interventions that direct the gastrointestinal microbiota closer to a healthy state may provide systemic benefits to these patients during a critical window of immune programming that might have implications for lifelong health.


Subject(s)
Bacteria/isolation & purification , Cystic Fibrosis/microbiology , Feces/microbiology , Gastrointestinal Microbiome , Bacteria/classification , Bacteria/genetics , Bacteria/growth & development , Bacteroides/genetics , Bacteroides/growth & development , Bacteroides/isolation & purification , Cohort Studies , Cystic Fibrosis/immunology , Female , Humans , Infant , Male , Respiratory System/immunology
2.
Anesth Analg ; 120(4): 819-26, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25790209

ABSTRACT

BACKGROUND: Gram-negative organisms are a major health care concern with increasing prevalence of infection and community spread. Our primary aim was to characterize the transmission dynamics of frequently encountered gram-negative bacteria in the anesthesia work area environment (AWE). Our secondary aim was to examine links between these transmission events and 30-day postoperative health care-associated infections (HCAIs). METHODS: Gram-negative isolates obtained from the AWE (patient nasopharynx and axilla, anesthesia provider hands, and the adjustable pressure-limiting valve and agent dial of the anesthesia machine) at 3 major academic medical centers were identified as possible intraoperative bacterial transmission events by class of pathogen, temporal association, and phenotypic analysis (analytical profile indexing). The top 5 frequently encountered genera were subjected to antibiotic disk diffusion sensitivity to identify epidemiologically related transmission events. Complete multivariable logistic regression analysis and binomial tests of proportion were then used to examine the relative contributions of reservoirs of origin and within- and between-case modes of transmission, respectively, to epidemiologically related transmission events. Analyses were conducted with and without the inclusion of duplicate transmission events of the same genera occurring in a given study unit (first and second case of the day in each operating room observed) to examine the potential effect of statistical dependency. Transmitted isolates were compared by pulsed-field gel electrophoresis to disease-causing bacteria for 30-day postoperative HCAIs. RESULTS: The top 5 frequently encountered gram-negative genera included Acinetobacter, Pseudomonas, Brevundimonas, Enterobacter, and Moraxella that together accounted for 81% (767/945) of possible transmission events. For all isolates, 22% (167/767) of possible transmission events were identified by antibiotic susceptibility patterns as epidemiologically related and underwent further study of transmission dynamics. There were 20 duplicates involving within- and between-case transmission events. Thus, approximately 19% (147/767) of isolates excluding duplicates were considered epidemiologically related. Contaminated provider hand reservoirs were less likely (all isolates, odds ratio 0.12, 95% confidence interval 0.03-0.50, P = 0.004; without duplicate events, odds ratio 0.05, 95% confidence interval 0.01-0.49, P = 0.010) than contaminated patient or environmental sites to serve as the reservoir of origin for epidemiologically related transmission events. Within- and between-case modes of gram-negative bacilli transmission occurred at similar rates (all isolates, 7% between-case, 5.2% within-case, binomial P value 0.176; without duplicates, 6.3% between-case, 3.7% within-case, binomial P value 0.036). Overall, 4.0% (23/548) of patients suffered from HCAIs and had an intraoperative exposure to gram-negative isolates. In 8.0% (2/23) of those patients, gram-negative bacteria were linked by pulsed-field gel electrophoresis to the causative organism of infection. Patient and provider hands were identified as the reservoirs of origin and the environment confirmed as a vehicle for between-case transmission events linked to HCAIs. CONCLUSIONS: Between- and within-case AWE gram-negative bacterial transmission occurs frequently and is linked by pulsed-field gel electrophoresis to 30-day postoperative infections. Provider hands are less likely than contaminated environmental or patient skin surfaces to serve as the reservoir of origin for transmission events.


Subject(s)
Anesthesia/adverse effects , Anesthesiology/instrumentation , Anesthesiology/methods , Gram-Negative Bacterial Infections/transmission , Acinetobacter , Adult , Aged , Cross Infection/prevention & control , Cross Infection/transmission , Enterobacter , Equipment Contamination , Female , Gram-Negative Bacteria , Hand/microbiology , Humans , Male , Middle Aged , Moraxella , Multivariate Analysis , Odds Ratio , Operating Rooms , Postoperative Period , Prospective Studies , Pseudomonas , Reproducibility of Results
3.
Anesth Analg ; 120(4): 807-18, 2015 Apr.
Article in English | MEDLINE | ID: mdl-24937345

ABSTRACT

BACKGROUND: Little is known regarding the epidemiology of intraoperative Staphylococcus aureus transmission. The primary aim of this study was to examine the mode of transmission, reservoir of origin, transmission locations, and antibiotic susceptibility for frequently encountered S aureus strains (phenotypes) in the anesthesia work area. Our secondary aims were to examine phenotypic associations with 30-day postoperative patient cultures, phenotypic growth rates, and risk factors for phenotypic isolation. METHODS: S aureus isolates previously identified as possible intraoperative bacterial transmission events by class of pathogen, temporal association, and analytical profile indexing were subjected to antibiotic disk diffusion sensitivity. The combination of these techniques was then used to confirm S aureus transmission events and to classify them as occurring within or between operative cases (mode). The origin of S aureus transmission events was determined via use of a previously validated experimental model and links to 30-day postoperative patient cultures confirmed via pulsed-field gel electrophoresis. Growth rates were assessed via time-to-positivity analysis, and risk factors for isolation were characterized via logistic regression. RESULTS: One hundred seventy S aureus isolates previously implicated as possible intraoperative transmission events were further subdivided by analytical profile indexing phenotype. Two phenotypes, phenotype P (patients) and phenotype H (hands), accounted for 65% of isolates. Phenotype P and phenotype H contributed to at least 1 confirmed transmission event in 39% and 28% of cases, respectively. Patient skin surfaces (odds ratio [OR], 8.40; 95% confidence interval [CI], 2.30-30.73) and environmental (OR, 10.89; 95% CI, 1.29-92.13) samples were more likely than provider hands (referent) to have phenotype P positivity. Phenotype P was more likely than phenotype H to be resistant to methicillin (OR, 4.38; 95% CI, 1.59-12.06; P = 0.004) and to be linked to 30-day postoperative patient cultures (risk ratio, 36.63 [risk difference, 0.174; 95% CI, 0.019-0.328]; P < 0.001). Phenotype P exhibited a faster growth rate for methicillin resistant and for methicillin susceptible than phenotype H (phenotype P: median, 10.32H; interquartile range, 10.08-10.56; phenotype H: median, 10.56H; interquartile range, 10.32-10.8; P = 0.012). Risk factors for isolation of phenotype P included age (OR, 14.11; 95% CI, 3.12-63.5; P = 0.001) and patient exposure to the hospital ward (OR, 41.11; 95% CI, 5.30-318.78; P < 0.001). CONCLUSIONS: Two S aureus phenotypes are frequently transmitted in the anesthesia work area. A patient and environmentally derived phenotype is associated with increased risk of antibiotic resistance and links to 30-day postoperative patient cultures as compared with a provider hand-derived phenotype. Future work should be directed toward improved screening and decolonization of patients entering the perioperative arena and improved intraoperative environmental cleaning to attenuate postoperative health care-associated infections.


Subject(s)
Anesthesiology/instrumentation , Cross Infection/prevention & control , Cross Infection/transmission , Staphylococcal Infections/epidemiology , Staphylococcal Infections/transmission , Adult , Aged , Anesthesia/adverse effects , Anesthesiology/methods , Anti-Bacterial Agents/therapeutic use , Cross Infection/epidemiology , Drug Resistance, Bacterial , Electrophoresis, Gel, Pulsed-Field , Equipment Contamination , Female , Humans , Male , Microbial Sensitivity Tests , Middle Aged , Operating Rooms , Phenotype , Postoperative Period , Prospective Studies , Risk Factors , Skin/drug effects , Staphylococcus aureus , Time Factors
4.
Anesth Analg ; 120(4): 827-36, 2015 Apr.
Article in English | MEDLINE | ID: mdl-24937346

ABSTRACT

BACKGROUND: Enterococci, the second leading cause of health care-associated infections, have evolved from commensal and harmless organisms to multidrug-resistant bacteria associated with a significant increase in patient morbidity and mortality. Prevention of ongoing spread of this organism within and between hospitals is important. In this study, we characterized Enterococcus transmission dynamics for bacterial reservoirs commonly encountered by anesthesia providers during the routine administration of general anesthesia. METHODS: Enterococcus isolates previously obtained from bacterial reservoirs frequently encountered by anesthesiologists (patient nasopharynx and axilla, anesthesia provider hands, and the adjustable pressure-limiting valve and agent dial of the anesthesia machine) at 3 major academic medical centers were identified as possible intraoperative bacterial transmission events by class of pathogen, temporal association, and phenotypic analysis (analytical profile indexing). They were then subjected to antibiotic disk diffusion sensitivity for transmission event confirmation. Isolates involved in confirmed transmission events were further analyzed to characterize the frequency, mode, origin, location of transmission events, and antibiotic susceptibility of transmitted pathogens. RESULTS: Three hundred eighty-nine anesthesia reservoir isolates were previously identified by gross morphology and simple rapid tests as Enterococcus. The combination of further analytical profile indexing analysis and temporal association implicated 43% (166/389) of those isolates in possible intraoperative bacterial transmission events. Approximately, 30% (49/166) of possible transmission events were confirmed by additional antibiotic disk diffusion analysis. Two phenotypes, E5 and E7, explained 80% (39/49) of confirmed transmission events. For both phenotypes, provider hands were a common reservoir of origin proximal to the transmission event (96% [72/75] hand origin for E7 and 89% [50/56] hand origin for E5) and site of transmission (94% [16/17] hand transmission location for E7 and 86% [19/22] hand transmission location for E5). CONCLUSIONS: Anesthesia provider hand contamination is a common proximal source and transmission location for Enterococcus transmission events in the anesthesia work area. Future work should evaluate the impact of intraoperative hand hygiene improvement strategies on the dynamics of intraoperative Enterococcus transmission.


Subject(s)
Anesthesia/adverse effects , Anesthesiology/instrumentation , Enterococcus faecalis , Gram-Positive Bacterial Infections/microbiology , Gram-Positive Bacterial Infections/transmission , Adult , Aged , Anesthesiology/methods , Anti-Bacterial Agents/therapeutic use , Cross Infection/epidemiology , Cross Infection/microbiology , Cross Infection/prevention & control , Cross Infection/transmission , Electrophoresis, Gel, Pulsed-Field , Equipment Contamination/prevention & control , Equipment Design , Female , Gram-Positive Bacterial Infections/epidemiology , Hand/microbiology , Hand Disinfection , Humans , Male , Microbial Sensitivity Tests , Middle Aged , Operating Rooms , Phenotype , Postoperative Period , Prospective Studies , Time Factors
5.
Anesth Analg ; 115(6): 1315-23, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23144441

ABSTRACT

BACKGROUND: Bacterial contamination of intravascular devices has been associated with increased morbidity and mortality in various hospital settings, including the perioperative environment. Catheter hub disinfection has been shown in an ex vivo model to attenuate intraoperative injection of bacterial organisms originating from the anesthesia provider's hands, providing the impetus for improvement in intraoperative disinfection techniques and compliance. In the current study, we investigated the clinical effectiveness of a new, passive catheter care station in reducing the incidence of bacterial contamination of open lumen patient IV stopcock sets. The secondary aim was to evaluate the impact of this novel intervention on the combined incidence of 30-day postoperative infections and IV catheter-associated phlebitis. METHODS: Five hundred ninety-four operating room environments were randomized by a computer-generated list to receive either a novel catheter care bundle (HubScrub and DOCit) or standard caps in conjunction with a sterile, conventional open lumen 3-way stopcock set (24 inch with 3-gang 4-way and T-Connector). Patients underwent general anesthesia according to usual practice and were followed prospectively for 30 postoperative days to identify the development of health care-associated infections (HCAIs) and/or phlebitis. The primary outcome was intraoperative bacterial contamination of the primary stopcock set used by the anesthesia provider(s). The secondary outcome was the combined incidence of 30-day postoperative infections and phlebitis. RESULTS: Five hundred seventy-two operating rooms were included in the final analysis. Study groups were comparable with no significant differences in patient, provider, anesthetic, or procedural characteristics. The catheter care station reduced the incidence of primary stopcock lumen contamination compared with standard caps (odds ratio [OR] 0.79, 95% confidence interval [CI] 0.63-0.98, P = 0.034) and was associated with a reduction in the combined incidence of HCAIs and IV catheter-associated phlebitis with and without adjustment for patient and procedural covariates (OR(adjusted) 0.589, 95% CI 0.353-0.984, P = 0.040). The risk-adjusted number needed to treat to eliminate 1 case of lumen contamination was 9 (95% CI 3.4-13.5) patients, whereas the risk-adjusted number needed to treat to eliminate 1 case of HCAI/catheter-associated phlebitis was 17 (95% CI 11.8-17.9) patients. CONCLUSION: Intraoperative use of a passive catheter care station significantly reduced open lumen bacterial contamination and the combined incidence of 30-day postoperative infections and phlebitis.


Subject(s)
Bacterial Infections/prevention & control , Catheter-Related Infections/prevention & control , Infection Control/methods , Injections, Intravenous/adverse effects , Injections, Intravenous/instrumentation , Intraoperative Care/methods , Adult , Aged , Anesthesia, General , Anesthesia, Intravenous , Bacterial Infections/epidemiology , Bacterial Infections/microbiology , Catheter-Related Infections/epidemiology , Cross Infection/epidemiology , Demography , Disinfection/methods , Double-Blind Method , Equipment Contamination , Female , Humans , Injections, Intravenous/methods , Male , Middle Aged , Operating Rooms/organization & administration , Phlebitis/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Prospective Studies , Surgical Wound Infection/prevention & control , Trauma Centers , Treatment Outcome
6.
Anesth Analg ; 114(6): 1236-48, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22467892

ABSTRACT

BACKGROUND: Intraoperative stopcock contamination is a frequent event associated with increased patient mortality. In the current study we examined the relative contributions of anesthesia provider hands, the patient, and the patient environment to stopcock contamination. Our secondary aims were to identify risk factors for stopcock contamination and to examine the prior association of stopcock contamination with 30-day postoperative infection and mortality. Additional microbiological analyses were completed to determine the prevalence of bacterial pathogens within intraoperative bacterial reservoirs. Pulsed-field gel electrophoresis was used to assess the contribution of reservoir bacterial pathogens to 30-day postoperative infections. METHODS: In a multicenter study, stopcock transmission events were observed in 274 operating rooms, with the first and second cases of the day in each operating room studied in series to identify within- and between-case transmission events. Reservoir bacterial cultures were obtained and compared with stopcock set isolates to determine the origin of stopcock contamination. Between-case transmission was defined by the isolation of 1 or more bacterial isolates from the stopcock set of a subsequent case (case 2) that were identical to reservoir isolates from the preceding case (case 1). Within-case transmission was defined by the isolation of 1 or more bacterial isolates from a stopcock set that were identical to bacterial reservoirs from the same case. Bacterial pathogens within these reservoirs were identified, and their potential contribution to postoperative infections was evaluated. All patients were followed for 30 days postoperatively for the development of infection and all-cause mortality. RESULTS: Stopcock contamination was detected in 23% (126 out of 548) of cases with 14 between-case and 30 within-case transmission events confirmed. All 3 reservoirs contributed to between-case (64% environment, 14% patient, and 21% provider) and within-case (47% environment, 23% patient, and 30% provider) stopcock transmission. The environment was a more likely source of stopcock contamination than provider hands (relative risk [RR] 1.91, confidence interval [CI] 1.09 to 3.35, P = 0.029) or patients (RR 2.56, CI 1.34 to 4.89, P = 0.002). Hospital site (odds ratio [OR] 5.09, CI 2.02 to 12.86, P = 0.001) and case 2 (OR 6.82, CI 4.03 to 11.5, P < 0.001) were significant predictors of stopcock contamination. Stopcock contamination was associated with increased mortality (OR 58.5, CI 2.32 to 1477, P = 0.014). Intraoperative bacterial contamination of patients and provider hands was linked to 30-day postoperative infections. CONCLUSIONS: Bacterial contamination of patients, provider hands, and the environment contributes to stopcock transmission events, but the surrounding patient environment is the most likely source. Stopcock contamination is associated with increased patient mortality. Patient and provider bacterial reservoirs contribute to 30-day postoperative infections. Multimodal programs designed to target each of these reservoirs in parallel should be studied intensely as a comprehensive approach to reducing intraoperative bacterial transmission.


Subject(s)
Anesthesiology/instrumentation , Bacterial Infections/transmission , Cross Infection/transmission , Disease Reservoirs , Environment, Controlled , Equipment Contamination , Operating Rooms , Surgical Wound Infection/etiology , Adult , Aged , Axilla/microbiology , Bacterial Infections/microbiology , Bacterial Infections/mortality , Bacterial Infections/prevention & control , Bacteriological Techniques , Cross Infection/microbiology , Cross Infection/mortality , Cross Infection/prevention & control , Electrophoresis, Gel, Pulsed-Field , Female , Gloves, Surgical/microbiology , Hand Disinfection , Humans , Infection Control , Intraoperative Period , Male , Middle Aged , Nasopharynx/microbiology , Odds Ratio , Prospective Studies , Risk Assessment , Risk Factors , Surgical Wound Infection/microbiology , Surgical Wound Infection/mortality , Surgical Wound Infection/prevention & control , Time Factors , United States
7.
Anesth Analg ; 115(5): 1109-19, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23051883

ABSTRACT

BACKGROUND: Device-related bloodstream infections are associated with a significant increase in patient morbidity and mortality in multiple health care settings. Recently, intraoperative bacterial contamination of conventional open-lumen 3-way stopcock sets has been shown to be associated with increased patient mortality. Intraoperative use of disinfectable, needleless closed catheter devices (DNCCs) may reduce the risk of bacterial injection as compared to conventional open-lumen devices due to an intrinsic barrier to bacterial entry associated with valve design and/or the capacity for surface disinfection. However, the relative benefit of DNCC valve design (intrinsic barrier capacity) as compared to surface disinfection in attenuation of bacterial injection in the clinical environment is untested and entirely unknown. The primary aim of the current study was to investigate the relative efficacy of a novel disinfectable stopcock, the Ultraport zero, with and without disinfection in attenuating intraoperative injection of potential bacterial pathogens as compared to a conventional open-lumen stopcock intravascular device. The secondary aims were to identify risk factors for bacterial injection and to estimate the quantity of bacterial organisms injected during catheter handling. METHODS: Four hundred sixty-eight operating room environments were randomized by a computer generated list to 1 of 3 device-injection schemes: (1) injection of the Ultraport zero stopcock with hub disinfection before injection, (2) injection of the Ultraport zero stopcock without prior hub disinfection, and (3) injection of the conventional open-lumen stopcock closed with sterile caps according to usual practice. After induction of general anesthesia, the primary anesthesia provider caring for patients in each operating room environment was asked to perform a series of 5 injections of sterile saline through the assigned device into an ex vivo catheter system. The primary outcome was the incidence of bacterial contamination of the injected fluid column (effluent). Risk factors for effluent contamination were identified in univariate analysis, and a controlled laboratory experiment was used to generate an estimate of the bacterial load injected for contaminated effluent samples. RESULTS: The incidence of effluent bacterial contamination was 0% (0/152) for the Ultraport zero stopcock with hub disinfection before injection, 4% (7/162) for the Ultraport zero stopcock without hub disinfection before injection, and 3.2% (5/154) for the conventional open-lumen stopcock. The Ultraport zero stopcock with hub disinfection before injection was associated with a significant reduction in the risk of bacterial injection as compared to the conventional open-lumen stopcock (RR = 8.15 × 10(-8), 95% CI, 3.39 × 10(-8) to 1.96 × 10(-7), P = <0.001), with an absolute risk reduction of 3.2% (95% CI, 0.5% to 7.4%). Provider glove use was a risk factor for effluent contamination (RR = 10.48, 95% CI, 3.16 to 34.80, P < 0.001). The estimated quantity of bacteria injected reached a clinically significant threshold of 50,000 colony-forming units per each injection series. CONCLUSIONS: The Ultraport zero stopcock with hub disinfection before injection was associated with a significant reduction in the risk of inadvertent bacterial injection as compared to the conventional open-lumen stopcock. Future studies should examine strategies designed to facilitate health care provider DNCC hub disinfection and proper device handling.


Subject(s)
Catheters/microbiology , Equipment Contamination/prevention & control , Equipment Design/standards , Hand/microbiology , Health Personnel/standards , Infectious Disease Transmission, Professional-to-Patient/prevention & control , Adult , Aged , Female , Humans , Infection Control , Injections, Intravenous , Male , Middle Aged , Single-Blind Method , Stem Cells/microbiology
8.
Otol Neurotol ; 42(7): e887-e893, 2021 08 01.
Article in English | MEDLINE | ID: mdl-33710149

ABSTRACT

HYPOTHESIS: Ciprofloxacin-resistant pathogens are inhibited by high concentrations of ciprofloxacin found in commercially-available ototopical solutions. BACKGROUND: Ciprofloxacin-resistant pathogens in otitis media are currently treated with ototopical ciprofloxacin suspensions. This is done irrespective of laboratory-reported ciprofloxacin susceptibility, under the assumption that the high concentration of ciprofloxacin applied topically is sufficient to overcome antimicrobial resistance. METHODS: We evaluated 34 ciprofloxacin-resistant isolates consisting of Staphylococcus aureus, Pseudomonas aeruginosa, Corynebacterium spp., and Turicella otitidis. Ciprofloxacin minimum inhibitory concentration (MIC) assays and clinical ototopical solution minimum bactericidal concentration (CMBC) assays were performed. RESULTS: Amongst the ciprofloxacin-resistant isolates, ciprofloxacin MICs ranged from 8 to 256 mcg/ml (mean: 87.1 mcg/ml) and CMBCs ranged from 23.4 to 1500 mcg/ml (mean: 237.0 mcg/ml). There were no significant differences with respect to MIC in comparing P. aeruginosa versus Corynebacterium spp. (mean: 53.3 versus 55.2, p = 0.86), S. aureus versus P. aeruginosa (mean: 128.0 versus 53.3, p = 0.34), and S. aureus versus Corynebacterium spp. (mean: 128.0 versus 55.2, p = 0.09). The correlation between ciprofloxacin MIC and CMBC was poor (Pearson's r = -0.08, p = 0.75). CONCLUSIONS: Ciprofloxacin-resistant pathogens commonly recovered from otitis media exhibit highly variable ciprofloxacin MIC and CMBC levels. Ciprofloxacin was able to inhibit growth in all isolates tested at MIC levels less than or equal to 256 mcg/ml; however, CMBC's up to 1500 mcg/ml were observed within that same group. The clinical relevance of these in vitro MICs is unclear due in part to higher bactericidal concentrations (CMBC) in several strains. Our results suggest that treatment failures may be due to a combination of factors rather than high-level resistance alone.


Subject(s)
Ciprofloxacin , Staphylococcus aureus , Ciprofloxacin/pharmacology , Corynebacterium , Humans , Microbial Sensitivity Tests , Pseudomonas aeruginosa
9.
Pediatr Pulmonol ; 55(7): 1661-1670, 2020 07.
Article in English | MEDLINE | ID: mdl-32275127

ABSTRACT

BACKGROUND: Mechanisms that facilitate early infection and inflammation in cystic fibrosis (CF) are unclear. We previously showed that young CF children with secondhand smoke exposure (SHSe) have increased susceptibility to respiratory infections. We aimed to define the impact of SHSe and other external factors upon the fecal bacteriome in early CF. METHODS: Twenty CF infants and children were enrolled, clinical data recorded, and hair nicotine measured as an objective surrogate of SHSe. Fecal samples were collected at clinic visits and bacteriome 16S rRNA gene sequencing performed. RESULTS: SHSe was associated with increased alpha diversity and increased relative abundance of Acinetobacter and Akkermansia, along with decreased Bifidobacterium and Lactobacillus. Recent antibiotic exposure predicted bacterial population structure in children less than 2 years of age and was associated with decreased Bacteroides relative abundance. Age was the strongest predictor of overall fecal bacterial composition and positively associated with Blautia and Parabacteroides. Weight for length was negatively associated with Staphylococcus relative abundance. CONCLUSIONS: SHSe and other external factors such as antibiotics appear to alter fecal bacterial composition in young CF children, but the strongest predictor of overall composition was age. These findings have implications for understanding the intestinal microbiome in young CF children.


Subject(s)
Aging , Cystic Fibrosis/microbiology , Feces/microbiology , Gastrointestinal Microbiome , Anti-Bacterial Agents/therapeutic use , Bacteria/genetics , Child, Preschool , Environmental Exposure , Female , Hair/chemistry , Humans , Infant , Male , Nicotine/analysis , RNA, Ribosomal, 16S/genetics , Tobacco Smoke Pollution
10.
mBio ; 10(4)2019 07 30.
Article in English | MEDLINE | ID: mdl-31363032

ABSTRACT

Pseudomonas aeruginosa and Staphylococcus aureus often cause chronic, recalcitrant infections in large part due to their ability to form biofilms. The biofilm mode of growth enables these organisms to withstand antibacterial insults that would effectively eliminate their planktonic counterparts. We found that P. aeruginosa supernatant increased the sensitivity of S. aureus biofilms to multiple antimicrobial compounds, including fluoroquinolones and membrane-targeting antibacterial agents, including the antiseptic chloroxylenol. Treatment of S. aureus with the antiseptic chloroxylenol alone did not decrease biofilm cell viability; however, the combination of chloroxylenol and P. aeruginosa supernatant led to a 4-log reduction in S. aureus biofilm viability compared to exposure to chloroxylenol alone. We found that the P. aeruginosa-produced small molecule 2-n-heptyl-4-hydroxyquinoline N-oxide (HQNO) is responsible for the observed heightened sensitivity of S. aureus to chloroxylenol. Similarly, HQNO increased the susceptibility of S. aureus biofilms to other compounds, including both traditional and nontraditional antibiotics, which permeabilize bacterial membranes. Genetic and phenotypic studies support a model whereby HQNO causes an increase in S. aureus membrane fluidity, thereby improving the efficacy of membrane-targeting antiseptics and antibiotics. Importantly, our data show that P. aeruginosa exoproducts can enhance the ability of various antimicrobial agents to kill biofilm populations of S. aureus that are typically difficult to eradicate. Finally, our discovery that altering membrane fluidity shifts antimicrobial sensitivity profiles of bacterial biofilms may guide new approaches to target persistent infections, such as those commonly found in respiratory tract infections and in chronic wounds.IMPORTANCE The thick mucus in the airways of cystic fibrosis (CF) patients predisposes them to frequent, polymicrobial respiratory infections. Pseudomonas aeruginosa and Staphylococcus aureus are frequently coisolated from the airways of individuals with CF, as well as from diabetic foot ulcers and other wounds. Both organisms form biofilms, which are notoriously difficult to eradicate and promote chronic infection. In this study, we have shown that P. aeruginosa-secreted factors can increase the efficacy of compounds that alone have little or no bactericidal activity against S. aureus biofilms. In particular, we discovered that P. aeruginosa exoproducts can potentiate the antistaphylococcal activity of phenol-based antiseptics and other membrane-active drugs. Our findings illustrate that polymicrobial interactions can dramatically increase antibacterial efficacy in vitro and suggest that altering membrane physiology promotes the ability of certain drugs to kill bacterial biofilms-knowledge that may provide a path for the discovery of new biofilm-targeting antimicrobial strategies.


Subject(s)
Anti-Bacterial Agents/pharmacology , Anti-Infective Agents, Local/pharmacology , Biofilms/drug effects , Pseudomonas aeruginosa/drug effects , Staphylococcus aureus/drug effects , Microbial Sensitivity Tests
11.
PLoS One ; 10(10): e0141192, 2015.
Article in English | MEDLINE | ID: mdl-26506004

ABSTRACT

Cystic Fibrosis (CF) is a human genetic disease that results in the accumulation of thick, sticky mucus in the airways, which results in chronic, life-long bacterial biofilm infections that are difficult to clear with antibiotics. Pseudomonas aeruginosa lung infection is correlated with worsening lung disease and P. aeruginosa transitions to an antibiotic tolerant state during chronic infections. Tobramycin is an aminoglycoside currently used to combat lung infections in individuals with CF. While tobramycin is effective at eradicating P. aeruginosa in the airways of young patients, it is unable to completely clear the chronic P. aeruginosa infections in older patients. A recent report showed that co-addition of tobramycin and mannitol enhanced killing of P. aeruginosa grown in vitro as a biofilm on an abiotic surface. Here we employed a model system of bacterial biofilms formed on the surface of CF-derived airway cells to determine if mannitol would enhance the antibacterial activity of tobramycin against P. aeruginosa grown on a more clinically relevant surface. Using this model system, which allows the growth of robust biofilms with high-level antibiotic tolerance analogous to in vivo biofilms, we were unable to find evidence for enhanced antibacterial activity of tobramycin with the addition of mannitol, supporting the observation that this type of co-treatment failed to reduce the P. aeruginosa bacterial load in a clinical setting.


Subject(s)
Biofilms/drug effects , Cystic Fibrosis/drug therapy , Pseudomonas Infections/drug therapy , Pseudomonas aeruginosa/drug effects , Biofilms/growth & development , Cystic Fibrosis/microbiology , Cystic Fibrosis/pathology , Humans , Lung/drug effects , Lung/microbiology , Lung/pathology , Mannitol/administration & dosage , Pseudomonas Infections/microbiology , Pseudomonas Infections/pathology , Pseudomonas aeruginosa/growth & development , Pseudomonas aeruginosa/pathogenicity , Tobramycin/administration & dosage
12.
Infect Dis Rep ; 2(1)2010 Feb 17.
Article in English | MEDLINE | ID: mdl-21709740

ABSTRACT

We report the isolation of Corynebacterium macginleyi from the corneal ulcer culture of a patient, later enrolled in the Steroids for Corneal Ulcer Trial (SCUT). To our knowledge this is the first published report from North America of the recovery of C. macginleyi from a serious ocular infection.

14.
J Cyst Fibros ; 8(3): 186-92, 2009 May.
Article in English | MEDLINE | ID: mdl-19250885

ABSTRACT

BACKGROUND: Respiratory pathogens from CF patients can contaminate inpatient settings, which may be associated with increased risk of patient-to-patient transmission. Few data are available that assess the rate of bacterial contamination of outpatient settings. We determined the frequency of contamination of CF clinics and the effectiveness of alcohol-based disinfectants in reducing hand carriage of bacterial pathogens. METHODS: We conducted a point prevalence survey and before-after trial in outpatient clinics at 7 CF centers. The study examined CF patients with positive respiratory cultures for Pseudomonas, Staphylococcus, Stenotrophomonas or Burkholderia species. Hand carriage and environmental contamination with respiratory pathogens were assessed during clinic visits (Part I) and the effectiveness of hand hygiene performed by CF patients (Part II) was determined using molecular typing of recovered isolates. RESULTS: In Part I (n=97), the contamination rate was 13.6%. Pseudomonas and S. aureus, including methicillin-resistant strains, were cultured from patients' hands (7%), the exam room air (8%), and less commonly, environmental surfaces (1%). In Part II (n=100), the hand carriage rate of pathogens was 13.5% and 4 participants without initial detection of pathogens had hand contamination when recultured at the end of the clinic visit. CONCLUSIONS: Respiratory pathogens from CF patients can contaminate their hands and the clinic environment, but the actual risk of patient-to-patient transmission in the outpatient setting remains difficult to quantify. These findings support several recommendations CF infection control recommendations including hand hygiene for staff and patients, contact precautions for certain pathogens, and disinfecting equipment and surfaces touched by patients and staff.


Subject(s)
Ambulatory Care Facilities/statistics & numerical data , Carrier State/epidemiology , Carrier State/microbiology , Cross Infection/epidemiology , Cystic Fibrosis/microbiology , Equipment Contamination/statistics & numerical data , Infectious Disease Transmission, Professional-to-Patient/statistics & numerical data , Air Microbiology , Alcohols/therapeutic use , Burkholderia/isolation & purification , Carrier State/prevention & control , Colony Count, Microbial , Cross Infection/prevention & control , Cross Infection/transmission , Cross-Sectional Studies , Equipment Contamination/prevention & control , Hand/microbiology , Hand Disinfection/methods , Humans , Infectious Disease Transmission, Professional-to-Patient/prevention & control , New England/epidemiology , Pseudomonas/isolation & purification , Staphylococcus aureus/isolation & purification , Stenotrophomonas/isolation & purification
15.
J Clin Microbiol ; 40(8): 2913-8, 2002 Aug.
Article in English | MEDLINE | ID: mdl-12149351

ABSTRACT

Streptococcus bovis causes 24% of all streptococcal infective endocarditis cases. There are many reports linking both S. bovis bacteremia and endocarditis with various forms of gastrointestinal disease (primarily colonic cancers). S. bovis is divided into two biotypes: I and II. The biotype I strain is much more frequently isolated from patients with endocarditis, gastrointestinal disease, or both. We describe here the isolation of biotype I-specific DNA sequences and the development of a PCR test which can identify S. bovis biotype I strains among S. bovis clinical isolates.


Subject(s)
Bacterial Typing Techniques , Streptococcus bovis/classification , Animals , Bacterial Proteins/genetics , Base Sequence , Cattle , Cloning, Molecular , DNA, Bacterial/analysis , Humans , Polymerase Chain Reaction/methods , Species Specificity , Streptococcal Infections/microbiology , Streptococcus bovis/genetics , Streptococcus bovis/isolation & purification
16.
Retina ; 22(5): 622-32, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12441729

ABSTRACT

PURPOSE: To determine the contribution of pneumolysin and autolysin, two putative pneumococcal virulence proteins, to the pathogenesis of Streptococcus pneumoniae endophthalmitis. METHODS: Endophthalmitis was established in Lewis rats by intravitreal injection of pneumococcal strains at an inoculum of 10 organisms. The virulence of three closely related type 2 S. pneumoniae strains were compared: a pneumolysin-deficient derivative (PLN-A), an autolysin-deficient derivative (AL-6), and their isogenic wild-type parent (D 39). Clinical and histologic inflammation scores were compared 24 hours and 48 hours after inoculation. RESULTS: Eyes infected with PLN-A and AL-6 strains showed less anterior segment inflammation clinically at 24 hours than did eyes infected with the wild-type strain. Histologic examination at 24 hours showed significantly less corneal infiltration and vitritis and more relative preservation of retinal tissue in eyes infected with PLN-A and AL-6 strains than in eyes infected with the wild-type strain. At 48 hours, no observable differences between PLN-A and wild-type strains were present clinically or histologically. Histologically, however, the AL-6 strain caused less retinal damage than did the wild-type strain. CONCLUSIONS: Intraocular infection with pneumolysin-deficient S. pneumoniae results in less severe tissue damage in the first 24 hours of disease compared with infection with pneumolysin-producing S. pneumoniae. Autolysin-deficient S. pneumoniae shows a similar degree of attenuated virulence. Pneumolysin and autolysin may contribute to the early pathogenesis of pneumococcal endophthalmitis.


Subject(s)
Cytotoxins/toxicity , Endophthalmitis/microbiology , Eye Infections, Bacterial/microbiology , N-Acetylmuramoyl-L-alanine Amidase/toxicity , Pneumococcal Infections/microbiology , Streptococcus pneumoniae/pathogenicity , Streptolysins/toxicity , Animals , Bacterial Proteins , Endophthalmitis/pathology , Eye Infections, Bacterial/pathology , Male , Pneumococcal Infections/pathology , Rats , Rats, Inbred Lew , Virulence
SELECTION OF CITATIONS
SEARCH DETAIL