1.
Am Heart J ; 272: 11-22, 2024 06.
Article in English | MEDLINE | ID: mdl-38458371

ABSTRACT

BACKGROUND: The optimal antiplatelet regimen after percutaneous coronary intervention (PCI) in patients with peripheral artery disease (PAD) is still debated. This analysis aimed to compare the effect of ticagrelor monotherapy versus ticagrelor plus aspirin in patients with PAD undergoing PCI. METHODS: In the TWILIGHT trial, patients at high ischemic or bleeding risk that underwent PCI were randomized after 3 months of dual antiplatelet therapy (DAPT) to aspirin or matching placebo in addition to open-label ticagrelor for 12 additional months. In this post-hoc analysis, patient cohorts were examined according to the presence or absence of PAD. The primary endpoint was Bleeding Academic Research Consortium (BARC) 2, 3, or 5 bleeding. The key secondary endpoint was a composite of all-cause death, myocardial infarction (MI), or stroke. Endpoints were assessed at 12 months after randomization. RESULTS: Among 7,119 patients, 489 (7%) had PAD and were older, more likely to have comorbidities, and multivessel disease. PAD patients had more bleeding or ischemic complications than no-PAD patients. Ticagrelor monotherapy compared to ticagrelor plus aspirin was associated with less BARC 2, 3, or 5 bleeding in PAD (4.6% vs 8.7%; HR 0.52; 95%CI 0.25-1.07) and no-PAD patients (4.0% vs 7.0%; HR 0.56; 95%CI 0.45-0.69; interaction P-value .830) and a similar risk of death, MI, or stroke in these 2 groups (interaction P-value .446). CONCLUSIONS: Despite their higher ischemic and bleeding risk, patients with PAD undergoing PCI derived a consistent benefit from ticagrelor monotherapy after 3 months of DAPT in terms of bleeding reduction without any relevant increase in ischemic events. CLINICAL TRIAL REGISTRY INFORMATION:: https://www. CLINICALTRIALS: gov/study/NCT02270242.


Subject(s)
Aspirin , Percutaneous Coronary Intervention , Peripheral Arterial Disease , Platelet Aggregation Inhibitors , Ticagrelor , Humans , Ticagrelor/therapeutic use , Aspirin/therapeutic use , Aspirin/administration & dosage , Peripheral Arterial Disease/complications , Percutaneous Coronary Intervention/methods , Male , Female , Aged , Platelet Aggregation Inhibitors/therapeutic use , Middle Aged , Drug Therapy, Combination , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Dual Anti-Platelet Therapy/methods , Myocardial Infarction/epidemiology , Stroke/prevention & control , Stroke/etiology , Stroke/epidemiology
2.
N Engl J Med ; 381(21): 2032-2042, 2019 11 21.
Article in English | MEDLINE | ID: mdl-31556978

ABSTRACT

BACKGROUND: Monotherapy with a P2Y12 inhibitor after a minimum period of dual antiplatelet therapy is an emerging approach to reduce the risk of bleeding after percutaneous coronary intervention (PCI). METHODS: In a double-blind trial, we examined the effect of ticagrelor alone as compared with ticagrelor plus aspirin with regard to clinically relevant bleeding among patients who were at high risk for bleeding or an ischemic event and had undergone PCI. After 3 months of treatment with ticagrelor plus aspirin, patients who had not had a major bleeding event or ischemic event continued to take ticagrelor and were randomly assigned to receive aspirin or placebo for 1 year. The primary end point was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 bleeding. We also evaluated the composite end point of death from any cause, nonfatal myocardial infarction, or nonfatal stroke, using a noninferiority hypothesis with an absolute margin of 1.6 percentage points. RESULTS: We enrolled 9006 patients, and 7119 underwent randomization after 3 months. Between randomization and 1 year, the incidence of the primary end point was 4.0% among patients randomly assigned to receive ticagrelor plus placebo and 7.1% among patients assigned to receive ticagrelor plus aspirin (hazard ratio, 0.56; 95% confidence interval [CI], 0.45 to 0.68; P<0.001). The difference in risk between the groups was similar for BARC type 3 or 5 bleeding (incidence, 1.0% among patients receiving ticagrelor plus placebo and 2.0% among patients receiving ticagrelor plus aspirin; hazard ratio, 0.49; 95% CI, 0.33 to 0.74). The incidence of death from any cause, nonfatal myocardial infarction, or nonfatal stroke was 3.9% in both groups (difference, -0.06 percentage points; 95% CI, -0.97 to 0.84; hazard ratio, 0.99; 95% CI, 0.78 to 1.25; P<0.001 for noninferiority). CONCLUSIONS: Among high-risk patients who underwent PCI and completed 3 months of dual antiplatelet therapy, ticagrelor monotherapy was associated with a lower incidence of clinically relevant bleeding than ticagrelor plus aspirin, with no higher risk of death, myocardial infarction, or stroke. (Funded by AstraZeneca; TWILIGHT ClinicalTrials.gov number, NCT02270242.).


Subject(s)
Aspirin/therapeutic use , Coronary Disease/therapy , Hemorrhage/chemically induced , Percutaneous Coronary Intervention , Platelet Aggregation Inhibitors/therapeutic use , Ticagrelor/therapeutic use , Aged , Aspirin/adverse effects , Coronary Disease/drug therapy , Double-Blind Method , Drug Therapy, Combination , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Mortality , Myocardial Infarction/epidemiology , Platelet Aggregation Inhibitors/adverse effects , Risk Factors , Stroke/epidemiology , Ticagrelor/adverse effects
3.
Catheter Cardiovasc Interv ; 99(3): 664-673, 2022 02.
Article in English | MEDLINE | ID: mdl-34582631

ABSTRACT

OBJECTIVES: to test the safety and efficacy of intravascular imaging and specifically optical coherence tomography (OCT) as a diagnostic tool for left main angioplasty and analyze the mid-term outcome accordingly. BACKGROUND: Clinical data and international guidelines recommend the use of intravascular imaging ultrasound (IVUS) to guide left main (LM) angioplasty. Despite early experience using OCT in this setting is encouraging, the evidence supporting its use is still limited. METHODS: ROCK II is a multicenter, investigator-driven, retrospective European study to compare the performance of IVUS and OCT versus angiography in patients undergoing distal-LM stenting. The primary study endpoint was target-lesion failure (TLF) including cardiac death, target-vessel myocardial infarction and target-lesion revascularization. We designed this study hypothesizing the superiority of intravascular imaging over angiographic guidance alone, and the non-inferiority of OCT versus IVUS. RESULTS: A total of 730 patients, 377 with intravascular-imaging guidance (162 OCT, 215 IVUS) and 353 with angiographic guidance, were analyzed. The one-year rate of TLF was 21.2% with angiography and 12.7% with intravascular-imaging (p = 0.039), with no difference between OCT and IVUS (p = 0.26). Intravascular-imaging was predictor of freedom from TLF (HR 0.46; 95% CI 0.23-0.93: p = 0.03). Propensity-score matching identified three groups of 100 patients each with no significant differences in baseline characteristics. The one-year rate of TLF was 16% in the angiographic, 7% in the OCT and 6% in the IVUS group, respectively (p = 0.03 for IVUS or OCT vs. angiography). No between-group significant differences in the rate of individual components of TLF were found. CONCLUSIONS: Intravascular imaging was superior to angiography for distal LM stenting, with no difference between OCT and IVUS.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Humans , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Retrospective Studies , Tomography, Optical Coherence/methods , Treatment Outcome , Ultrasonography, Interventional/methods
4.
Catheter Cardiovasc Interv ; 99(3): 889-895, 2022 02.
Article in English | MEDLINE | ID: mdl-34390296

ABSTRACT

OBJECTIVES: We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. BACKGROUND: The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. METHODS: Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. RESULTS: Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 ± 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 ± 0.8% and 2.2 ± 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 ± 0.2 vs. 2.1 ± 0.6 cm2 ) and mean aortic valve gradient (43.4 ± 11.1 vs. 9.0 ± 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. CONCLUSIONS: Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Female , Humans , Male , Prosthesis Design , Retrospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
5.
Eur Heart J ; 42(45): 4624-4634, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34662382

ABSTRACT

AIMS: Patients at high bleeding risk (HBR) represent a prevalent subgroup among those undergoing percutaneous coronary intervention (PCI). Early aspirin discontinuation after a short course of dual antiplatelet therapy (DAPT) has emerged as a bleeding avoidance strategy. The aim of this study was to assess the effects of ticagrelor monotherapy after 3-month DAPT in a contemporary HBR population. METHODS AND RESULTS: This prespecified analysis of the TWILIGHT trial evaluated the treatment effects of early aspirin withdrawal followed by ticagrelor monotherapy in HBR patients undergoing PCI with drug-eluting stents. After 3 months of ticagrelor plus aspirin, event-free patients were randomized to 12 months of aspirin or placebo in addition to ticagrelor. A total of 1064 (17.2%) met the Academic Research Consortium definition for HBR. Ticagrelor monotherapy reduced the incidence of the primary endpoint of Bleeding Academic Research Consortium (BARC) 2, 3, or 5 bleeding compared with ticagrelor plus aspirin in HBR (6.3% vs. 11.4%; hazard ratio (HR) 0.53, 95% confidence interval (CI) 0.35-0.82) and non-HBR patients (3.5% vs. 5.9%; HR 0.59, 95% CI 0.46-0.77) with similar relative (Pinteraction = 0.67) but a trend towards greater absolute risk reduction in the former [-5.1% vs. -2.3%; difference in absolute risk differences (ARDs) -2.8%, 95% CI -6.4% to 0.8%, P = 0.130]. A similar pattern was observed for more severe BARC 3 or 5 bleeding with a larger absolute risk reduction in HBR patients (-3.5% vs. -0.5%; difference in ARDs -3.0%, 95% CI -5.2% to -0.8%, P = 0.008). There was no significant difference in the key secondary endpoint of death, myocardial infarction, or stroke between treatment arms, irrespective of HBR status. CONCLUSIONS: Among HBR patients undergoing PCI who completed 3-month DAPT without experiencing major adverse events, aspirin discontinuation followed by ticagrelor monotherapy significantly reduced bleeding without increasing ischaemic events, compared with ticagrelor plus aspirin. The absolute risk reduction in major bleeding was larger in HBR than non-HBR patients.


Subject(s)
Percutaneous Coronary Intervention , Drug Therapy, Combination , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Humans , Percutaneous Coronary Intervention/adverse effects , Platelet Aggregation Inhibitors/adverse effects , Ticagrelor/adverse effects , Treatment Outcome
6.
Eur Heart J ; 42(45): 4683-4693, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34423374

ABSTRACT

AIMS: The aim of this study was to assess the impact of chronic kidney disease (CKD) on the safety and efficacy of ticagrelor monotherapy among patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS: In this prespecified subanalysis of the TWILIGHT trial, we evaluated the treatment effects of ticagrelor with or without aspirin according to renal function. The trial enrolled patients undergoing drug-eluting stent implantation who fulfilled at least one clinical and one angiographic high-risk criterion. Chronic kidney disease, defined as an estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2, was a clinical study entry criterion. Following a 3-month period of ticagrelor plus aspirin, event-free patients were randomly assigned to aspirin or placebo on top of ticagrelor for an additional 12 months. Of the 6835 patients randomized and with available eGFR at baseline, 1111 (16.3%) had CKD. Ticagrelor plus placebo reduced the primary endpoint of Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 bleeding as compared with ticagrelor plus aspirin in both patients with [4.6% vs. 9.0%; hazard ratio (HR) 0.50, 95% confidence interval (CI) 0.31-0.80] and without (4.0% vs. 6.7%; HR 0.59, 95% CI 0.47-0.75; Pinteraction = 0.508) CKD, but the absolute risk reduction was greater in the former group. Rates of death, myocardial infarction, or stroke were not significantly different between the two randomized groups irrespective of the presence (7.9% vs. 5.7%; HR 1.40, 95% CI 0.88-2.22) or absence of (3.2% vs. 3.6%; HR 0.90, 95% CI 0.68-1.20; Pinteraction = 0.111) CKD. CONCLUSION: Among CKD patients undergoing PCI, ticagrelor monotherapy reduced the risk of bleeding without a significant increase in ischaemic events as compared with ticagrelor plus aspirin.


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Renal Insufficiency, Chronic , Drug Therapy, Combination , Humans , Platelet Aggregation Inhibitors/therapeutic use , Renal Insufficiency, Chronic/complications , Renal Insufficiency, Chronic/drug therapy , Ticagrelor/therapeutic use , Treatment Outcome
7.
Catheter Cardiovasc Interv ; 97(3): 411-420, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32198845

ABSTRACT

OBJECTIVES: We aimed to evaluate the use of bare metal stent (BMS) implantation in current percutaneous coronary intervention (PCI) era, focusing on indications for use and clinical outcomes. BACKGROUND: Limited data on BMS usage in current clinical practice are available. METHODS: All patients who underwent PCI with at least one BMS implantation in 18 Italian centers from January 1, 2013 to December 31, 2017, were included in our registry. Rates of BMS use and reasons for BMS implantations were reported for the overall study period and for each year. Primary outcomes were mortality, bleeding (Bleeding Academic Research Consortium-BARC and Thrombolysis in Myocardial Infarction-TIMI non-CABG definitions), and major adverse cardiac events (MACE) defined as the composite of all-cause and cardiac death, any myocardial infarction, target vessel revascularization, or any stent thrombosis. RESULTS: Among 58,879 patients undergoing PCI in the study period, 2,117 (3.6%) patients (mean age 73 years, 69.7% males, 73.3% acute coronary syndrome) were treated with BMS implantation (2,353 treated lesions). The rate of BMS implantation progressively decreased from 10.1% (2013) to 0.3% (2017). Main reasons for BMS implantation were: ST-elevation myocardial infarction (STEMI) (23.1%), advanced age (24.4%), and physician's perception of high-bleeding risk (34.0%). At a mean follow-up of 2.2 ± 1.5 years, all-cause and cardiac mortality were 25.6 and 12.7%, respectively; MACE rate was 35.3%, any bleeding rate was 13.0% (BARC 3-5 bleeding 6.3%, TIMI non-CABG major bleeding 6.1%). CONCLUSION: In a large, contemporary, real-world, multicenter registry, BMS use progressively reduced over the last 5 years. Main reasons for BMS implantation were STEMI, advanced age, and physician's perception of high-bleeding risk. High rates of mortality and MACE were observed in this real-world high-risk population.


Subject(s)
Drug-Eluting Stents , Percutaneous Coronary Intervention , Female , Humans , Italy , Male , Percutaneous Coronary Intervention/adverse effects , Registries , Stents , Treatment Outcome
8.
Catheter Cardiovasc Interv ; 97(3): 516-526, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32865860

ABSTRACT

OBJECTIVE: To evaluate the incidence, predictors and outcomes of female patients with patient-prosthesis mismatch (PPM) following transcatheter aortic valve intervention (TAVI) for severe aortic stenosis (AS). BACKGROUND: Female AS TAVI recipients have a significantly lower mortality than surgical aortic valve replacement (SAVR) recipients, which could be attributed to the potentially lower PPM rates. TAVI has been associated with lower rates of PPM compared to SAVR. PPM in females post TAVI has not been investigated to date. METHODS: The WIN-TAVI (Women's INternational Transcatheter Aortic Valve Implantation) registry is a multicenter registry of women undergoing TAVR for severe symptomatic AS. Two hundred and fifty patients with detailed periprocedural and follow-up echocardiographic investigations were included in the WIN-TAVI echocardiographic sub-study. PPM was defined as per European guidelines stratified by the presence of obesity. RESULTS: The incidence of PPM in our population was 32.8%. Patients with PPM had significantly higher BMI (27.4 ± 6.1 vs. 25.2 ± 5.0, p = .002), smaller sized valves implanted (percentage of TAVI ≤23 mm 61% vs. 29.2%, PPM vs. no PPM, p < .001) and were more often treated with balloon expandable valves (48.3 vs. 32.5%, p < .001) rather than self expanding ones (26.3 vs. 52.8%, <.001). BMI (OR = 1.08; 95%CI 1.02-1.14, p = .011) and valve size ≤23 mm (OR = 3.00 95%CI 1.14-7.94, p = .027) were the only independent predictors of PPM. There was no significant interaction between valve size and valve type (p = .203). No significant differences were observed in 1-year mortality or major adverse cardiovascular events. CONCLUSIONS: PPM in females undergoing TAVI occurs in one third of patients. BMI and valve size ≤23 mm are independent predictors. Larger registries are required to determine the impact of PPM on future clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery , Female , Humans , Postoperative Complications , Prevalence , Registries , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 98(6): E908-E917, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34117817

ABSTRACT

OBJECTIVES: To describe the incidence, predictors, and clinical impact of permanent pacemaker insertion (PPI) following transcatheter aortic valve replacement (TAVR) in women. BACKGROUND: Data on pacemaker insertion complicating TAVR in women are scarce. METHODS: The Women's International Transcatheter Aortic Valve implantation (WIN-TAVI) is a prospective registry evaluating the safety and efficacy of TAVR in women. We included patients without preprocedural pacemakers and divided them into two groups: (1) PPI and (2) no-PPI. We identified PPI predictors using logistic regression and studied its clinical impact on the Valve Academic Research Consortium (VARC)-2 efficacy and safety endpoints. RESULTS: Out of 1019 patients, 922 were included in the analysis. Post-TAVR PPI occurred in 132 (14.3%) patients. Clinical and procedural characteristics were similar in both groups. Pre-existing right bundle branch block (RBBB) was associated with a high risk of post-TAVR PPI (OR 3.62, 95% CI 1.85-7.06, p < 0.001), while implantation of balloon-expandable prosthesis was associated with a lower risk (OR 0.47, 95% CI 0.30-0.74, p < 0.001). Post-TAVR PPI prolonged in-hospital stay by a median of 2 days (11 [9-16] days in PPI vs. 9 [7-14] days in no-PPI, p = 0.005), yet risks of VARC-2 efficacy and safety endpoints at 1 year were similar in both groups (adj HR 0.95, 95% CI 0.60-1.52, p = 0.84 and adj HR 1.22, 95% CI 0.83-1.79, p = 0.31, respectively). CONCLUSION: Pacemaker implantation following TAVR is frequent among women and is associated with pre-existing RBBB and valve type. PPI prolongs hospital stay, albeit without any significant impact on 1-year outcomes.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Incidence , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 97(5): E704-E715, 2021 04 01.
Article in English | MEDLINE | ID: mdl-33002302

ABSTRACT

OBJECTIVES: To assess the impact of anemia on clinical outcomes in female patients enrolled in the Women's InterNational transcatheter aortic valve implantation (WIN-TAVI) registry. BACKGROUND: Anemia is highly prevalent among females who constitute half of TAVI candidates, yet, its clinical significance remains poorly investigated. METHODS: Patients were divided into three groups according to preprocedural hemoglobin (Hb) level: (1) no anemia (Hb ≥12 g/dl), (2) mild-to-moderate anemia (10 ≤ Hb <12 g/dl), and (3) severe anemia (Hb <10 g/dl). The primary outcome was the occurrence of Valve Academic Research Consortium (VARC)-2 efficacy endpoint, a composite of mortality, stroke, myocardial infarction (MI), hospitalization for valve-related symptoms or heart failure or valve-related dysfunction at 1-year follow-up. RESULTS: Hemoglobin level was available in 877 (86.1%) patients: 412 (47.0%) had no anemia, 363 (41.4%) had mild-to-moderate anemia, and 102 (11.6%) had severe anemia. The latter group had a higher prevalence of cardiovascular risk factors. Compared with patients without anemia, severe anemia was associated with a greater risk of VARC-2 efficacy endpoint (adj HR 1.71, 95% CI: 1.02-2.87, p = .04), all-cause death (adj HR 2.36, 95% CI: 1.31-4.26, p = .004) and a composite of death, MI or stroke (adj HR 1.88, 95% CI: 1.10-3.22, p = .02) at 1 year. Moreover, an increased risk of late mortality (adj HR 1.15, 95% CI: 1.02-1.30, p = .03) was observed with every 1 g/dl decrease in hemoglobin level. CONCLUSION: Severe anemia in females undergoing TAVI was independently associated with increased rates of VARC-2 efficacy endpoint and mortality at 1 year.


Subject(s)
Anemia , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Anemia/epidemiology , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Female , Humans , Registries , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
11.
Eur Heart J ; 41(37): 3533-3545, 2020 10 01.
Article in English | MEDLINE | ID: mdl-33085967

ABSTRACT

AIMS: The aim of this study was to determine the effect of ticagrelor monotherapy on clinically relevant bleeding and major ischaemic events in relation to clinical presentation with and without non-ST elevation acute coronary syndromes (NSTE-ACS) among patients undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES). METHODS AND RESULTS: We conducted a pre-specified subgroup analysis of The Ticagrelor With Aspirin or Alone in High Risk Patients After Coronary Intervention (TWILIGHT) trial, which enrolled 9006 patients with high-risk features undergoing PCI with DES. After 3 months of dual antiplatelet therapy (DAPT) with ticagrelor plus aspirin, 7119 adherent and event-free patients were randomized in a double-blind manner to ticagrelor plus placebo versus ticagrelor plus aspirin for 12 months. The primary outcome was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 bleeding while the composite of all-cause death, myocardial infarction (MI), or stroke was the key secondary outcome. Among patients with NSTE-ACS (n = 4614), ticagrelor monotherapy reduced BARC 2, 3, or 5 bleeding by 53% [3.6% vs. 7.6%; hazard ratio (HR) 0.47; 95% confidence interval (CI) 0.36-0.61; P < 0.001) and in stable patients (n = 2503) by 24% (4.8% vs. 6.2%; HR 0.76; 95% CI 0.54-1.06; P = 0.11; nominal Pint = 0.03). Rates of all-cause death, MI, or stroke among those with (4.3% vs. 4.4%; HR 0.97; 95% CI 0.74-1.28; P = 0.84) and without (3.1% vs. 3.2%; HR 0.96; 95% CI 0.61-1.49; P = 0.85) NSTE-ACS were similar between treatment arms irrespective of clinical presentation (Pint = 0.96). CONCLUSION: Among patients with or without NSTE-ACS who have completed an initial 3-month course of DAPT following PCI with DES, ticagrelor monotherapy reduced clinically meaningful bleeding events without increasing ischaemic risk as compared with ticagrelor plus aspirin. The benefits of ticagrelor monotherapy with respect to bleeding events were more pronounced in patients with NSTE-ACS. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT02270242.


Subject(s)
Acute Coronary Syndrome , Percutaneous Coronary Intervention , Acute Coronary Syndrome/drug therapy , Aspirin/therapeutic use , Drug Therapy, Combination , Humans , Platelet Aggregation Inhibitors/therapeutic use , Ticagrelor/therapeutic use , Treatment Outcome
12.
Catheter Cardiovasc Interv ; 96(6): 1156-1171, 2020 11.
Article in English | MEDLINE | ID: mdl-31883294

ABSTRACT

BACKGROUND: Residual stent strut thrombosis after primary percutaneous coronary intervention (PCI), negatively affects myocardial perfusion, may increase stent thrombosis risk, and it is associated with neointima hyperplasia at follow-up. OBJECTIVES: To study the effectiveness of any bivalirudin infusion versus unfractionated heparin (UFH) infusion in reducing residual stent strut thrombosis in patients with ST-elevation myocardial infarction (STEMI). METHODS: Multi-vessel STEMI patients undergoing primary PCI and requiring staged intervention were selected among those randomly allocated to two different bivalirudin infusion regimens in the MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and angioX) Treatment-Duration study. Those receiving heparin only were enrolled into a registry arm. Optical coherence tomography (OCT) of the infarct-related artery was performed at the end of primary PCI and 3-5 days thereafter during a staged intervention. The primary endpoint was the change in minimum flow area (ΔMinFA) defined as (stent area + incomplete stent apposition [ISA] area) - (intraluminal defect + tissue prolapsed area) between the index and staged PCI. RESULTS: 123 patients in bivalirudin arm and 28 patients in the UFH arm were included. Mean stent area, percentage of malapposed struts, and mean percent thrombotic area were comparable after index or staged PCI. The ΔMinFA in the bivalirudin group was 0.25 versus 0.05 mm2 in the UFH group, which resulted in a between-group significant difference of 0.36 [95% CI: (0.05, 0.71); p = .02]. This was mostly related to a decrease in tissue protrusion in the bivalirudin group (p = .03). There was a trend towards more patients in the bivalirudin group who achieved a 5% difference in the percentage of OCT frames with the area >5% (p = .057). CONCLUSIONS: The administration of bivalirudin after primary PCI significantly reduces residual stent strut thrombosis when compared to UFH. This observation should be considered hypothesis-generating since the heparin-treated patients were not randomly allocated.


Subject(s)
Anticoagulants/administration & dosage , Antithrombins/administration & dosage , Coronary Thrombosis/therapy , Heparin/administration & dosage , Hirudins/administration & dosage , Peptide Fragments/administration & dosage , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction/therapy , Tomography, Optical Coherence , Aged , Anticoagulants/adverse effects , Antithrombins/adverse effects , Coronary Thrombosis/diagnostic imaging , Female , Hemorrhage/chemically induced , Heparin/adverse effects , Hirudins/adverse effects , Humans , Infusions, Parenteral , Italy , Male , Middle Aged , Neointima , Peptide Fragments/adverse effects , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Predictive Value of Tests , Prospective Studies , Recombinant Proteins/administration & dosage , Recombinant Proteins/adverse effects , ST Elevation Myocardial Infarction/diagnostic imaging , Stents , Time Factors , Treatment Outcome
13.
Catheter Cardiovasc Interv ; 96(1): 198-207, 2020 07.
Article in English | MEDLINE | ID: mdl-31977142

ABSTRACT

BACKGROUND: The prevalence of both chronic kidney disease (CKD) and aortic stenosis (AS) increase with age. Although baseline CKD is frequent in patients undergoing transcatheter aortic valve replacement (TAVR), its significance among women is largely unknown. METHODS: Women's INternational Transcatheter Aortic Valve Implantation (WIN-TAVI) is a multinational, prospective registry of women undergoing TAVR for severe AS. We included patients with available baseline estimated glomerular filtration rate (eGFR) and completed 1-year follow-up. Patients were categorized into three groups based on their eGFR: No CKD (normal kidney function to stage 2 CKD: eGFR ≥60 ml/min/1.73 m2 ); (b) mild CKD (stage 3a CKD: eGFR = 45-59 ml/min/1.73 m2 ); and (c) moderate/severe CKD (stage ≥3b CKD: eGFR <45 ml/min/1.73 m2 ). All events were adjudicated according to the Valve Academic Research Consortium (VARC)-2 criteria. RESULT: Out of 852 women undergoing TAVR, 326 (38.3%) had no CKD, 225 (26.4%) had mild CKD, and 301 (35.3%) had moderate/severe CKD. Women with higher stage of CKD at baseline were more likely to have a history of hypertension, diabetes, atrial fibrillation, anemia, chronic lung disease, hemodialysis, prior percutaneous coronary intervention, and pacemaker implantation. After multivariate adjustment, moderate/severe CKD was associated with a greater risk of 1-year VARC-2 safety endpoints [hazard ratio (HR) 1.68, 95% confidence interval (CI): 1.10-2.60], all-cause death (HR 2.00, 95% CI: 1.03-3.90), and composite of death, myocardial infarction, stroke or life-threatening bleeding (HR 1.70, 95% CI: 1.04-2.76). There were no differences in 30-day and 1-year VARC-2 efficacy and 30-day VARC-2 safety outcomes. CONCLUSION: CKD is associated with substantial and independent risk for mortality and morbidity at 1-year follow-up in women undergoing TAVR.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Glomerular Filtration Rate , Humans , Kidney/physiopathology , Registries , Renal Insufficiency, Chronic/diagnosis , Renal Insufficiency, Chronic/mortality , Renal Insufficiency, Chronic/physiopathology , Retrospective Studies , Risk Assessment , Risk Factors , Severity of Illness Index , Sex Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
14.
Lancet ; 392(10150): 835-848, 2018 09 08.
Article in English | MEDLINE | ID: mdl-30153988

ABSTRACT

BACKGROUND: The Minimizing Adverse Haemorrhagic Events by Transradial Access Site and Systemic Implementation of Angiox (MATRIX) programme was designed to assess the comparative safety and effectiveness of radial versus femoral access and of bivalirudin versus unfractionated heparin with optional glycoprotein IIb/IIIa inhibitors in patients with the whole spectrum of acute coronary syndrome undergoing invasive management. Here we describe the prespecified final 1-year outcomes of the entire programme. METHODS: MATRIX was a programme of three nested, randomised, multicentre, open-label, superiority trials in patients with acute coronary syndrome in 78 hospitals in Italy, the Netherlands, Spain, and Sweden. Patients with ST-elevation myocardial infarction were simultaneously randomly assigned (1:1) before coronary angiography to radial or femoral access and to bivalirudin, with or without post-percutaneous coronary intervention infusion or unfractionated heparin (one-step inclusion). Patients with non-ST-elevation acute coronary syndrome were randomly assigned (1:1) before coronary angiography to radial or femoral access and, only if deemed eligible to percutaneous coronary intervention after angiography (two-step inclusion), entered the antithrombin type and treatment duration programmes. Randomisation sequences were computer generated, blocked, and stratified by intended new or current use of P2Y12 inhibitor (clopidogrel vs ticagrelor or prasugrel), and acute coronary syndrome type (ST-elevation myocardial infarction, troponin-positive, or troponin-negative non-ST-elevation acute coronary syndrome). Bivalirudin was given as a bolus of 0·75 mg/kg, followed immediately by an infusion of 1·75 mg/kg per h until completion of percutaneous coronary intervention. Heparin was given at 70-100 units per kg in patients not receiving glycoprotein IIb/IIIa inhibitors, and at 50-70 units per kg in patients receiving glycoprotein IIb/IIIa inhibitors. Clinical follow-up was done at 30 days and 1 year. Co-primary outcomes for MATRIX access and MATRIX antithrombin type were major adverse cardiovascular events, defined as the composite of all-cause mortality, myocardial infarction, or stroke up to 30 days; and net adverse clinical events, defined as the composite of non-coronary artery bypass graft-related major bleeding, or major adverse cardiovascular events up to 30 days. The primary outcome for MATRIX treatment duration was the composite of urgent target vessel revascularisation, definite stent thrombosis, or net adverse clinical events up to 30 days. Analyses were done according to the intention-to-treat principle. This trial is registered with ClinicalTrials.gov, number NCT01433627. FINDINGS: Between Oct 11, 2011, and Nov 7, 2014, we randomly assigned 8404 patients to receive radial (4197 patients) or femoral (4207 patients) access. Of these 8404 patients, 7213 were included in the MATRIX antithrombin type study and were randomly assigned to bivalirudin (3610 patients) or heparin (3603 patients). Patients assigned to bivalirudin were included in the MATRIX treatment duration study, and were randomly assigned to post-procedure infusion (1799 patients) or no post-procedure infusion (1811 patients). At 1 year, major adverse cardiovascular events did not differ between patients assigned to radial access compared with those assigned to femoral access (14·2% vs 15·7%; rate ratio 0·89, 95% CI 0·80-1·00; p=0·0526), but net adverse clinical events were fewer with radial than with femoral access (15·2% vs 17·2%; 0·87, 0·78-0·97; p=0·0128). Compared with heparin, bivalirudin was not associated with fewer major adverse cardiovascular (15·8% vs 16·8%; 0·94, 0·83-1·05; p=0·28) or net adverse clinical events (17·0% vs 18·4%; 0·91, 0·81-1·02; p=0·10). The composite of urgent target vessel revascularisation, stent thrombosis, or net adverse clinical events did not differ with or without post-procedure bivalirudin infusion (17·4% vs 17·4%; 0·99, 0·84-1·16; p=0·90). INTERPRETATION: In patients with acute coronary syndrome, radial access was associated with lower rates of net adverse clinical events compared with femoral access, but not major adverse cardiovascular events at 1 year. Bivalirudin with or without post-procedure infusion was not associated with lower rates of major adverse cardiovascular events or net adverse clinical events. Radial access should become the default approach in acute coronary syndrome patients undergoing invasive management. FUNDING: Italian Society of Invasive Cardiology, The Medicines Company, Terumo, amd Canada Research Chairs Programme.


Subject(s)
Acute Coronary Syndrome/surgery , Anticoagulants/administration & dosage , Antithrombins/administration & dosage , Femoral Artery , Heparin/administration & dosage , Hirudins/administration & dosage , Peptide Fragments/administration & dosage , Percutaneous Coronary Intervention/methods , Radial Artery , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/diagnostic imaging , Aged , Anticoagulants/adverse effects , Antithrombins/adverse effects , Coronary Angiography , Female , Hemorrhage/chemically induced , Heparin/adverse effects , Hirudins/adverse effects , Humans , Male , Middle Aged , Mortality , Myocardial Infarction/etiology , Peptide Fragments/adverse effects , Percutaneous Coronary Intervention/adverse effects , Perioperative Care , Platelet Glycoprotein GPIIb-IIIa Complex/antagonists & inhibitors , Prosthesis Failure/etiology , Recombinant Proteins/administration & dosage , Recombinant Proteins/adverse effects , Stents/adverse effects , Stroke/etiology
15.
Catheter Cardiovasc Interv ; 93(6): E346-E348, 2019 05 01.
Article in English | MEDLINE | ID: mdl-30286525

ABSTRACT

Cerebral ischemic lesions occurring during transcatheter valve interventions are common feared complications and the use of filter device seems to reduce their incidence. We report the case of an 84-year old female patient with severe mitral regurgitation undergoing MitraClip. During the trans-esophageal echocardiography (TEE)-guided procedure was detected the presence of a little fibrin strand adherent to the steerable guide catheter for which we decided to implant the Claret CE Pro (Claret Medical, Inc. Santa Rosa, CA, USA) cerebral protection device and to continue the procedure during which the thrombus disappeared. At the end of the procedure a big thrombus was detected in the distal filter. The histologic analysis of the debris captured by the filters showed the presence of a thrombus, compatible with the image identified by TEE.


Subject(s)
Cardiac Catheterization/instrumentation , Embolic Protection Devices , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Intracranial Embolism/prevention & control , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Thromboembolism/prevention & control , Aged, 80 and over , Cardiac Catheterization/adverse effects , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Intracranial Embolism/etiology , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/physiopathology , Prosthesis Design , Recovery of Function , Severity of Illness Index , Thromboembolism/etiology , Treatment Outcome
16.
Catheter Cardiovasc Interv ; 93(2): 208-215, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30298593

ABSTRACT

OBJECTIVES: To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM). BACKGROUND: SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed. METHODS: Patients from the multicenter SPARTA (clinicaltrials.gov: NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points. RESULTS: Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation. CONCLUSION: SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.


Subject(s)
Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Self Expandable Metallic Stents , Sirolimus/administration & dosage , Aged , Aged, 80 and over , Alloys , Cardiovascular Agents/adverse effects , Comparative Effectiveness Research , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Registries , Retrospective Studies , Risk Assessment , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
17.
Catheter Cardiovasc Interv ; 93(6): 1124-1131, 2019 05 01.
Article in English | MEDLINE | ID: mdl-30511802

ABSTRACT

OBJECTIVES: To evaluate the impact of coronary artery disease (CAD) with or without recent (≤ 30 days) percutaneous coronary intervention (PCI) in women undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Although women display a specific risk-profile for both PCI and TAVR, the impact of CAD and PCI in the setting of TAVR in women is unclear. METHODS: The multinational Women's International Transcatheter Aortic Valve implantation registry enrolled consecutive female patients undergoing contemporary TAVR in 19 centers between 2013 and 2015. Patients with available coronary angiography or CT scan in the pre-operative assessment of TAVR were categorized as without CAD, with CAD but no recent PCI and CAD and recent PCI (≤30 days). All events were adjudicated according to the VARC-2 criteria. RESULTS: A total of 787 patients were included in this analysis, among whom 459 (58.3%) had no CAD, 247 (31.4%) had CAD without recent PCI and 81 (10.3%) underwent recent PCI (≤ 30 days before TAVR). After multivariable adjustment, both groups of CAD patients, without and with recent PCI, presented with higher risk of death, myocardial infarction or stroke, compared with patients without CAD (adj HR 1.56, 95%CI 1.03-2.39, P = 0.038 and adj HR 1.96, 95% CI 1.1-3.5, P = .021, respectively). Patients with recent PCI had increased risk of all-cause death (adj HR 1.89, 95% CI 1.0-3.5, P = 0.04) and stroke (adj HR 3.7, 95% CI 1.0-13.5, P = 0.046) compared with patients without CAD. CONCLUSION: The presence of CAD in women undergoing TAVR, with or without recent PCI, was associated with long-term poorer outcomes.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/pathology , Aortic Valve/surgery , Calcinosis/surgery , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Calcinosis/diagnostic imaging , Calcinosis/mortality , Calcinosis/physiopathology , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Female , Hemodynamics , Humans , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Registries , Risk Assessment , Risk Factors , Sex Factors , Stroke/mortality , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome
18.
Catheter Cardiovasc Interv ; 93(7): 1374-1381, 2019 Jun 01.
Article in English | MEDLINE | ID: mdl-31116908

ABSTRACT

BACKGROUND/OBJECTIVE: Prostar XL (PS) and ProGlide (PG) are common vascular closure devices (VCD) used in TAVR via transfemoral vascular approach. The impact of these VCD on vascular and bleeding complications remains unclear. METHODS: The BRAVO-3 trial randomized 802 patients undergoing transfemoral TAVR. We stratified patients according to type of VCD used and examined the 30-day incidence of major or minor vascular complications, major bleeding (BARC ≥3b), AKI and major adverse cardiac and cerebrovascular events (MACCE; death, myocardial infarction or stroke). RESULTS: A total of 746 (93%) patients were treated with either PS (n = 352, 47%) or PG (n = 394, 53%) VCD, without significant differences in successful deployment rate (PS 322 [91.2%] vs. PG 373 [94.2%] respectively, p = .20). PG was associated with a significantly lower incidence of major or minor vascular complications, compared to PS (adjusted OR: 0.54; 95% CI: 0.37-0.80; p < .01). Rates of acute kidney injury were also lower with the PG device. There was no significant difference between bleeding, MACCE, and death. CONCLUSIONS: Compared to PS, the PG VCD was associated with a lower rate of major or minor vascular complications and lower rates of AKI after transfemoral TAVR.


Subject(s)
Aortic Valve Stenosis/surgery , Hemorrhage/prevention & control , Hemostatic Techniques/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Vascular Closure Devices , Vascular Diseases/prevention & control , Acute Kidney Injury/etiology , Acute Kidney Injury/prevention & control , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Canada , Equipment Design , Europe , Female , Hemorrhage/etiology , Hemorrhage/mortality , Hemostatic Techniques/adverse effects , Hemostatic Techniques/mortality , Humans , Male , Randomized Controlled Trials as Topic , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Vascular Diseases/etiology , Vascular Diseases/mortality
19.
N Engl J Med ; 373(11): 997-1009, 2015 Sep 10.
Article in English | MEDLINE | ID: mdl-26324049

ABSTRACT

BACKGROUND: Conflicting evidence exists on the efficacy and safety of bivalirudin administered as part of percutaneous coronary intervention (PCI) in patients with an acute coronary syndrome. METHODS: We randomly assigned 7213 patients with an acute coronary syndrome for whom PCI was anticipated to receive either bivalirudin or unfractionated heparin. Patients in the bivalirudin group were subsequently randomly assigned to receive or not to receive a post-PCI bivalirudin infusion. Primary outcomes for the comparison between bivalirudin and heparin were the occurrence of major adverse cardiovascular events (a composite of death, myocardial infarction, or stroke) and net adverse clinical events (a composite of major bleeding or a major adverse cardiovascular event). The primary outcome for the comparison of a post-PCI bivalirudin infusion with no post-PCI infusion was a composite of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events. RESULTS: The rate of major adverse cardiovascular events was not significantly lower with bivalirudin than with heparin (10.3% and 10.9%, respectively; relative risk, 0.94; 95% confidence interval [CI], 0.81 to 1.09; P=0.44), nor was the rate of net adverse clinical events (11.2% and 12.4%, respectively; relative risk, 0.89; 95% CI, 0.78 to 1.03; P=0.12). Post-PCI bivalirudin infusion, as compared with no infusion, did not significantly decrease the rate of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events (11.0% and 11.9%, respectively; relative risk, 0.91; 95% CI, 0.74 to 1.11; P=0.34). CONCLUSIONS: In patients with an acute coronary syndrome, the rates of major adverse cardiovascular events and net adverse clinical events were not significantly lower with bivalirudin than with unfractionated heparin. The rate of the composite of urgent target-vessel revascularization, definite stent thrombosis, or net adverse clinical events was not significantly lower with a post-PCI bivalirudin infusion than with no post-PCI infusion. (Funded by the Medicines Company and Terumo Medical; MATRIX ClinicalTrials.gov number, NCT01433627.).


Subject(s)
Acute Coronary Syndrome/drug therapy , Anticoagulants/therapeutic use , Heparin/therapeutic use , Peptide Fragments/therapeutic use , Acute Coronary Syndrome/mortality , Aged , Anticoagulants/adverse effects , Combined Modality Therapy , Coronary Thrombosis/prevention & control , Female , Heparin/adverse effects , Hirudins/adverse effects , Humans , Incidence , Infusions, Intravenous , Male , Middle Aged , Myocardial Infarction/epidemiology , Peptide Fragments/adverse effects , Percutaneous Coronary Intervention/statistics & numerical data , Recombinant Proteins/adverse effects , Recombinant Proteins/therapeutic use , Stents , Stroke/epidemiology
20.
N Engl J Med ; 383(1): 88-89, 2020 07 02.
Article in English | MEDLINE | ID: mdl-32343497
SELECTION OF CITATIONS