Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
Add more filters

Publication year range
1.
Clin Transplant ; 38(7): e15404, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39023077

ABSTRACT

BACKGROUND: The axillary artery (AX) access for intra-aortic balloon pump (IABP) as a bridge to heart transplant (HT) allows mobility while awaiting a suitable donor. As end-stage heart failure patients often have an implantable cardioverter defibrillator (ICD) on the left side, the left AX approach may be avoided due to the perception of difficult access and proximity of two devices. We aimed to evaluate the outcomes of patients bridged to HT with a left-sided AX IABP with or without ipsilateral ICDs. METHODS: We retrospectively reviewed HT candidates at our institution supported by left-sided axillary IABP from November 2019 to February 2024, dividing them into two groups based on the presence (Group ICD, n = 48) or absence (Group No-ICD, N = 19) of an ipsilateral left-sided ICD. The exposure time was defined as the time from skin incision to the beginning of anastomoses of a Dacron graft. RESULTS: Technical success was achieved in 100% of the cohort, with median exposure times for AX access similar between groups (ICD, 12 [7.8, 18.2] vs. No ICD, 11 [7, 19] min; p = 0.75). The rate of procedural adverse events, such as significant access site bleeding and ipsilateral limb ischemia, did not significantly differ between both groups. Device malfunction rates were comparable (ICD, 29.2% vs. No ICD, 15.8%; p = 0.35). Posttransplant, in-hospital mortality, severe primary graft dysfunction, and stroke rates were comparable in both groups. CONCLUSION: The presence of an ipsilateral left-sided ICD does not adversely impact the procedural efficacy, complication rates, or posttransplant outcomes of left-sided AX IABP insertion in HT candidates.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart Transplantation , Intra-Aortic Balloon Pumping , Humans , Female , Male , Retrospective Studies , Middle Aged , Heart Failure/surgery , Heart Failure/therapy , Follow-Up Studies , Prognosis , Axillary Artery
2.
Clin Transplant ; 38(9): e15451, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39222289

ABSTRACT

BACKGROUND: Cardiac surgery is considered a contraindication in patients with advanced liver cirrhosis (LC) due to increased mortality and morbidity. There are limited data on the treatment strategy and management of this population. We aimed to present our strategy and evaluate the clinical outcome of cardiac surgery in patients with LC. METHODS: Our strategy was (i) to list patients for liver transplant (LT) at the time of cardiac surgery; (ii) to maintain high cardiopulmonary bypass (CPB) flow (index up to 3.0 L/min/m2) based on hyper-dynamic states due to LC; and (iii) to proceed to LT if patients' liver function deteriorated with an increasing model for end-stage liver disease Na (MELD-Na) score after cardiac surgery. Thirteen patients (12 male and 1 female [mean age, 63.0]) with LC who underwent cardiac surgery between 2017 and 2024 were retrospectively analyzed. RESULTS: Six patients were listed for LT. Indications for cardiac surgery included coronary artery disease (N = 7), endocarditis (N = 2), and tricuspid regurgitation (N = 1), tricuspid stenosis (N = 1), mitral regurgitation (N = 1), and hypertrophic obstructive cardiomyopathy (N = 1). The Child-Pugh score was A in five, B in six, and C in one patient. The procedure included coronary artery bypass grafting (N = 6), single valve surgery (mitral valve [N = 2] and tricuspid valve [N = 1]), concomitant aortic and tricuspid valve surgery (N = 2), and septal myectomy (N = 1). Two patients had a history of previous sternotomy. The perfusion index during CPB was 3.1 ± 0.5 L/min/m2. Postoperative complications include pleural effusion (N = 6), bleeding events (N = 3), acute kidney injury (N = 1), respiratory failure requiring tracheostomy (N = 2), tamponade (N = 1), and sternal infection (N = 1). There was no in-hospital death. There was one remote death due to COVID-19 complication. Preoperative and postoperative highest MELD-Na score among listed patients was 15.8 ± 5.1 and 19.3 ± 5.3, respectively. Five patients underwent LT (1, 5, 8, 16, and 24 months following cardiac surgery) and one patient remains on the list. Survival rates at 1 and 3 years are 100% and 75.0%, respectively. CONCLUSION: Cardiac surgery maintaining high CPB flow with LT backup is a feasible strategy in an otherwise inoperable patient population with an acceptable early and midterm survival when performed in a center with an experienced cardiac surgery and LT program.


Subject(s)
Cardiac Surgical Procedures , Liver Cirrhosis , Liver Transplantation , Humans , Male , Female , Middle Aged , Liver Cirrhosis/surgery , Liver Cirrhosis/complications , Retrospective Studies , Cardiac Surgical Procedures/methods , Prognosis , Aged , Postoperative Complications , Survival Rate , Follow-Up Studies , COVID-19/complications , Treatment Outcome , Heart Diseases/surgery , Heart Diseases/complications
3.
Article in English | MEDLINE | ID: mdl-39121906

ABSTRACT

OBJECTIVE: Percutaneous deep venous arterialisation (pDVA) is a state of the art technique for treating patients with chronic limb threatening ischaemia (CLTI) with no conventional option for revascularisation. There are limited large scale data examining the clinical effectiveness of pDVA for patients with end stage CLTI. DATA SOURCES: MEDLINE, Embase, Google Scholar, and Cochrane databases. REVIEW METHODS: Four databases were searched from January 2018 to June 2024 to identify studies investigating the feasibility and clinical outcomes of pDVA for patients with CLTI with no conventional revascularisation options. Meta-analysis of time to event outcomes (mean ± standard deviation) was performed for amputation free survival as the primary outcome, and freedom from amputation and overall survival as secondary outcomes. Other secondary outcomes (mean and 95% confidence interval [CI]) were procedural success rate, patency, re-intervention, and complete wound healing. RESULTS: Ten non-randomised studies were included with 351 patients. The mean patient age was 70.3 years, and 67.6% were male. Most procedures used the posterior tibial artery. The aggregated rate of amputation free survival at six and twelve months (five studies, 260 patients) was 72.6 ± 2.8% and 66.0 ± 3.1%, respectively, while the overall survival at six and twelve months (five studies, 260 patients) was 85.0 ± 2.3% and 77.7 ± 2.9%, respectively. The procedural success rate (nine studies, 330 patients) was 95.5% (95% CI 92.4 - 98.7%). Primary and secondary patency at six months (four studies, 241 patients) was 23.4% (95% CI 13.6 - 33.2%) and 54.9% (95% CI 34.3 - 75.5%), respectively. The rates of re-intervention (four studies, 190 patients) and complete wound healing (five studies, 190 patients) at twelve months were 41.7% (95% CI 25.7 - 57.7%) and 46.0% (95% CI 31.7 - 60.3%), respectively. CONCLUSION: This meta-analysis demonstrated acceptable feasibility for no option CLTI at highly specialised institutions for patients undergoing pDVA. Meta-analysis of time to event outcomes revealed that pDVA provides reasonable amputation free survival for up to twelve months, albeit with a overall low certainty of evidence. Wider adoption of pDVA may be considered in selected patients with CLTI, although its clinical impact and cost effectiveness require further evaluation.

4.
Artif Organs ; 2024 Sep 17.
Article in English | MEDLINE | ID: mdl-39286938

ABSTRACT

BACKGROUND: The Impella 5.5® is commonly inserted via the axillary artery (AX) in patients with cardiogenic shock. The right AX has traditionally been preferred to avoid crossing the aortic arch, and a minimum diameter of 7 mm has been recommended to accommodate the device (21 Fr). There is limited data on choice of laterality of access and AX size required, both in terms of technicality of the procedure as well as outcomes. METHODS: We performed a single-center retrospective cohort analysis of patients who underwent Impella 5.5® implantation between December 2020 and February 2024 (N = 75). Data including demographics and outcomes were stratified both by diameter (small, <7 mm vs. normal, ≥7 mm) and laterality of access (right vs. left). Adverse events included stroke, limb ischemia, procedural bleeding or infection, and unplanned explant due to complications. Delivery time was defined as time from advancing the first wire to activation of the device. RESULTS: AX approach was attempted in all (N = 74) but one requiring innominate access, with a technical success rate of 95.9% (N = 71/74). The mean age was 58.8 ± 13.3 years, with 81.1% males. The median delivery time was 7.0 (25th, 75th percentiles: 4.0, 11.5) min with a median support duration of 13 (7.7, 24) days. Ten patients (13.5%) had a small AX, with a mean diameter of 6.3 ± 0.5 mm and were more likely to be younger compared to the normal AX group. Fifty-nine patients (79.7%) had insertion via the right AX. Median delivery time was comparable across all groups (small, 5.4 [3.5, 10.9] vs. normal, 7 [4.0, 12.1] min, p = 0.59) and (right, 10.4 [5.3, 15.2] vs. left, 6 [3.7, 10.4] min, p = 0.35). There was no difference between the rates of stroke, ischemia, bleeding, or infection when comparing by size or laterality. Survival to discharge was 59.5%, with 21.1% mortality on support, all in patients with a normal AX diameter, but with no difference between right versus left. CONCLUSION: In our study, laterality and a small diameter of AX access did not affect outcomes of Impella 5.5®, with a similar safety profile.

5.
Artif Organs ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39239771

ABSTRACT

BACKGROUND: The Organ Care System (OCS) (Transmedics, Andover, MA) reduces cold ischemic time of donor hearts by producing a normothermic beating state during ex vivo perfusion, enabling extended ex situ intervals, which potentially increases donor pool. We aimed to compare outcomes in utilization of OCS and conventional cold storage technique. METHODS: Consecutive heart transplants following brain death at our institution between May 2022 and July 2023 were analyzed. Recipients were divided into those receiving hearts preserved with OCS [N = 15] and those with conventional cold storage (Control, N = 27), with OCS utilization when anticipated ischemic time was more than 4 h. Pre-transplant characteristics and transplant outcomes were compared. RESULTS: OCS utilization allowed a significant increase in distance traveled for heart retrieval (OCS, 624 ± 269 vs. Control, 153 ± 128 miles, p < 0.001), with longer mean total preservation times (6.2 ± 1.1 vs 2.6 ± 0.6 h, p < 0.001). All but one patient displayed a general decrease or plateau in lactate throughout perfusion time by OCS. Both groups experienced similar rates of severe primary graft dysfunction (OCS, 6.7% [N = 1] vs. Control, 11.1% [N = 3], p = 0.63), with 100% in-hospital survival in the OCS group compared to 96.3% in the Control group (p = 0.34). Kaplan-Meier survival analysis showed that estimated one-year survival were comparable (OCS, 93.3 ± 6.4% vs. Control, 88.9 ± 6.0%, p = 0.61). CONCLUSION: With a mean preservation time of around 6 h and distance covered of over 600 miles, our results using OCS indicate a potential to safely increase the quantity and viability of accessible organs, thus broadening the donor pool without negatively affecting outcomes.

6.
Catheter Cardiovasc Interv ; 102(7): 1291-1300, 2023 12.
Article in English | MEDLINE | ID: mdl-37890015

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is as an alternative treatment to surgical AVR, but the long-term outcomes of TAVR remain unclear. AIMS: This study aimed to analyze long-term outcomes following TAVR using meta-analysis. METHODS: A literature search was performed with MEDLINE, EMBASE, Cochrane Library, Web of Science, and Google Scholar through November 2022; studies reporting clinical outcomes of TAVR with follow-up periods of ≥8 years were included. The outcomes of interest were overall survival and/or freedom from structural valve deterioration (SVD). Surgical risk was assessed with the Society of Thoracic Surgeons (STS) predicted risk of mortality (PROM) score. A subgroup analysis was conducted for intermediate-/high-surgical risk patients only. RESULTS: Eleven studies including 5458 patients were identified and analyzed. The mean age was 82.0 ± 6.5 years, and mean STS PROM score ranged from 2.9 to 10.6%. Survival rate at 5 and 10 years was 47.7% ± 1.4% and 12.1 ± 2.0%. Five studies including 1509 patients were analyzed for SVD. Freedom from SVD at 5 and 8 years was 95.5 ± 0.7% and 85.1 ± 3.1%. Similar results for survival and SVD were noted in the subgroup analysis of intermediate-/high-risk patients. CONCLUSIONS: Following TAVR, approximately 88% of patients died within 10 years, whereas 85% were free from SVD at 8 years. These date suggest that baseline patient demographic have the greatest impact on survival, and SVD does not seem to have a prognostic impact in this population. Further investigations on longer-term outcomes of younger and lower-risk patients are warranted.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors
7.
J Card Surg ; 37(11): 3964-3966, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36116048

ABSTRACT

Surgical treatment of infective endocarditis remains a challenge, with concerns of optimal prosthesis selection and risks of recurrent infection remaining paramount. The pulmonary autograft has unique features which may make it the ideal aortic valve substitute, especially in infectious endocarditis. We describe strategic considerations and technical details in performing a Ross procedure in a young patient with acute aortic valve endocarditis.


Subject(s)
Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis Implantation , Pulmonary Valve , Aortic Valve/surgery , Autografts , Endocarditis/surgery , Endocarditis, Bacterial/surgery , Humans , Pulmonary Valve/transplantation , Transplantation, Autologous , Treatment Outcome
8.
Artif Organs ; 45(2): 124-134, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32813920

ABSTRACT

We have studied the cardiac beat synchronization (CBS) control for a rotary blood pump (RBP) and revealed that it can promote pulsatility and reduce cardiac load. Besides, patients with LVAD support sometimes suffer from aortic and mitral regurgitation (AR and MR). A control method for the RBP should be validated in wider range of conditions to clarify its benefits and pitfalls prior to clinical application. In this study, we evaluated pulsatility and cardiac load reduction obtained with the CBS control on valvular failure conditions with a mathematical model. Diastolic assist could reduce cardiac load on the left ventricle by decreasing external work of the ventricle even in MR cases while it was not so effective in AR cases. Systolic assist can still promote pulsatility in AR and MR cases; however, aortic valve function should be carefully confirmed since pulse pressure can be wider not due to systolic assist but to AR.


Subject(s)
Aortic Valve Insufficiency/prevention & control , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Mitral Valve Insufficiency/prevention & control , Models, Cardiovascular , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Blood Pressure/physiology , Diastole/physiology , Heart Failure/physiopathology , Heart Rate/physiology , Heart Ventricles/physiopathology , Humans , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/physiopathology , Pulsatile Flow , Systole/physiology , Ventricular Function, Left/physiology
9.
J Artif Organs ; 24(4): 419-424, 2021 Dec.
Article in English | MEDLINE | ID: mdl-33825101

ABSTRACT

Although the influence of continuous-flow left ventricular assist device (CF-LVAD) support on peripheral circulation has been widely discussed, its monitoring modalities are limited. The aim of this study was to assess the peripheral circulation using the laser speckle flowgraph (LSFG) which can quantitatively measure the ocular blood flow. We implanted a centrifugal CF-LVAD (EVAHEART®; Sun Medical Technology Research Corporation, Nagano, Japan) in five adult goats (body weight 44.5 ± 2.9 kg) under general anesthesia. The waveform of the central retinal artery using the mean blur rate (MBR) for ocular blood velocity and fluctuations as a parameter of pulsatility were obtained before LVAD implantation and after LVAD full-bypass support. The MBR waveform and LSFG fluctuation data were compared with the waveform and pulsatility index of the external carotid artery using an ultrasonic flow meter to evaluate circulatory patterns at different levels. The MBR waveform pattern of the central retinal artery was pulsatile before LVAD implantation and less pulsatile under LVAD full bypass. The fluctuation was 14.7 ± 1.86 before LVAD implantation and 3.85 ± 0.61 under LVAD full bypass (p < 0.01), respectively. The fluctuations of LSFG showed a strong correlation with the pulsatility index of the external carotid artery meaning that similar changes in circulatory pattern were observed at two different levels. Measuring the ocular blood flow using LSFG has potential utility for the assessment of the status of the peripheral circulation and its pulsatility during CF-LVAD.


Subject(s)
Eye/blood supply , Heart-Assist Devices , Regional Blood Flow , Animals , Blood Flow Velocity , Goats , Hemodynamics , Laser-Doppler Flowmetry , Lasers
10.
J Card Surg ; 36(11): 4369-4375, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34472140

ABSTRACT

OBJECTIVE: The optimal harvesting technique of saphenous vein (SVG) in coronary artery bypass grafting (CABG) is still to be elucidated. The present study aimed to compare the methods of SVG harvesting technique, which were open vein harvesting (OVH), endoscopic vein harvesting (EVH), and no-touch vein harvesting (NT), using a network meta-analysis of randomized controlled trials (RCTs), and propensity-score matched (PSM) studies. METHODS: MEDLINE and EMBASE were searched through April 2021 to identify RCTs and PSM studies that investigated the outcomes in patients who underwent CABG with the SVG using one of three methods; OVH, EVH, and NT. The outcomes of interest were all-cause mortality, the rates of revascularization, and graft failure. Risk ratios (RRs) were extracted for the rates of graft failure, and hazard ratios (HRs) were extracted for all-cause mortality and the rates of revascularization. RESULTS: Eligible seven RCT and five PSM studies were identified which enrolled a total of 8111 patients. All-cause mortality was significantly lower in patients with EVH compared with OVH (HR [95% confidence interval (CI)] =0.77 [0.65-0.92], p = .0032). The rates of revascularization were similar among the groups. The rate of graft failures was significantly lower in patients with NT compared with OVH (HR [95% CI] =0.54 [0.32-0.90], p = .019) and with EVH (HR [95% CI] =0.39 [0.17-0.86], p = .023). CONCLUSION: NT vein harvesting is favorable for graft patency, and OVH showed higher all-cause mortality than EVH. Further well-powered RCTs are needed to confirm our findings.


Subject(s)
Coronary Artery Bypass , Saphenous Vein , Endoscopy , Humans , Network Meta-Analysis , Tissue and Organ Harvesting
11.
Artif Organs ; 43(9): 821-827, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30891800

ABSTRACT

We developed a novel miniaturized extracorporeal centrifugal pump "BIOFLOAT NCVC (Nipro Corporation Osaka, Japan) as a ventricular assist device (VAD) and performed a preclinical study that is part of the process for its approval as a bridge to decision by the pharmaceutical and medical device agencies. The aim of this study was to assess the postoperative performance, hemocompatibility, and anticoagulative status during an extended period of its use. A VAD system, consisting of a hydrodynamically levitated pump, measuring 64 mm by 131 mm in size and weighing 635 g, was used. We installed this assist system in 9 adult calves (body weight, 90 ± 13 kg): as left ventricular assist device (LVAD) in 6 calves and right ventricular assist device (RVAD) in 3 calves, for over 30 days. Perioperative hemodynamic, hematologic, and blood chemistry measurements were obtained and end-organ effects on necropsy were investigated. All calves survived for over 30 days, with a good general condition. The blood pump was operated at a mean rotational speed and a mean pump flow of 3482 ± 192 rpm and 4.08 ± 0.15 L/min, respectively, for the LVAD and 3902 ± 210 rpm and 4.24 ± 0.3 L/min, respectively, for the RVAD. Major adverse events, including neurological or respiratory complications, bleeding events, and infection were not observed. This novel VAD enabled a long-term support with consistent and satisfactory hemodynamic performance and hemocompatibility in the calf model. The hemodynamic performance, hemocompatibility, and anticoagulative status of this VAD system were reviewed.


Subject(s)
Heart-Assist Devices , Hemodynamics , Animals , Anticoagulants/therapeutic use , Cattle , Disease Models, Animal , Equipment Design , Extracorporeal Circulation/instrumentation , Heart Failure/physiopathology , Heart Failure/surgery , Heart-Assist Devices/adverse effects , Hemorrhage/etiology , Humans , Hydrodynamics , Male , Thrombosis/etiology , Thrombosis/prevention & control
12.
J Artif Organs ; 22(4): 276-285, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31327062

ABSTRACT

We studied a control method of rotary blood pumps (RBPs), which is called as the cardiac beat synchronization (CBS) system. Usually, RBPs operate at constant target rotational speed, meanwhile, the CBS system modulates target speed synchronizing with cardiac beat. We built a computer simulation method to evaluate the CBS system. This simulator acquires a mathematical model of a circulatory system including a RBP and can provide us the theoretical hemodynamics when our control method is applied. We compared theoretical results with experimental ones with the model focusing on both pulsatility and aortic valve (AV) opening interval enhanced by the CBS system. Our simulator could reproduce behavior of the circulatory system whether the RBP is connected or not. Comparison among no RBP, constant assist, systolic assist, and diastolic assist modes indicated that pulsatility is enhanced with systolic assist theoretically. While systolic assist decreased AV opening interval, diastolic assist made it longer than the ones in other control strategies.


Subject(s)
Aortic Valve/physiopathology , Computer Simulation , Heart Rate/physiology , Heart-Assist Devices , Models, Cardiovascular , Diastole , Humans , Pulsatile Flow , Systole
13.
J Artif Organs ; 22(4): 269-275, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31203458

ABSTRACT

Under continuous-flow left ventricular assist device (CF-LVAD) support, the ventricular volume change and cardiac cycle between the left ventricle (LV) and right ventricle (RV) become dyssynchronous due to the shortening of the LV systole. The purpose of this study was to quantify interventricular dyssynchrony based on different CF-LVAD support conditions and assess its relationship with LV unloading. In this study, we evaluated seven goats (body weight 44.5 ± 6.5 kg) with normal hearts. A centrifugal LVAD was implanted under general anesthesia. We inserted the conductance catheters into the left ventricle (LV) and right ventricle (RV) to assess the volume signal simultaneously. We defined the interventricular dyssynchrony as a signal (increase or decrease) of LV volume (LVV) change opposite to that of RV volume (RVV) (i.e., (dLVV/dt) × (dRVV/dt) < 0). The duration of interventricular dyssynchrony (DYS) was reported as the percentage of time that a heart was in a dyssynchronous state within a cardiac cycle. The mean DYS of normal hearts, hearts with LVAD clamp and hearts supported by LVADs with a bypass rate of 50%, 75% and 100% were 5.6 ± 1.6%, 8.7 ± 2.4%, 8.6 ± 2.8%, 15.1 ± 5.1%, and 25.6 ± 8.0%, respectively. Furthermore, the DYS was found to be associated with the degree of LV stroke volume reduction caused by LV unloading. These findings may be useful for understanding interventricular interactions and physiology during CF-LVAD support. Influences on the right ventricular function and heart failure models warrant further study.


Subject(s)
Cardiac Volume/physiology , Heart Failure/physiopathology , Heart Rate/physiology , Heart Ventricles/physiopathology , Heart-Assist Devices , Ventricular Function, Left/physiology , Ventricular Function, Right/physiology , Animals , Cardiac Catheterization , Disease Models, Animal , Goats , Heart Failure/diagnosis , Heart Failure/therapy , Heart Ventricles/diagnostic imaging , Systole
14.
J Artif Organs ; 22(4): 348-352, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31267351

ABSTRACT

The purpose of this study was to observe and clarify the interventricular dysscynchrony caused by continuous-flow left ventricular assist device (CF-LVAD) support using the conductance method. During CF-LVAD support, the systolic phase of the left ventricle (LV) becomes shorter than that of the right ventricle (RV). Accordingly, timing of the systole and diastole during the cardiac cycle is not synchronous between the LV and RV. In this study, we evaluated this phenomenon in a normal heart model using the adult goat (n = 5, body weight 44.5 ± 2.9 kg). A centrifugal LVAD was implanted under general anesthesia. We inserted the conductance catheter into the RV and LV to obtain the pressure-volume relationship of the two ventricles simultaneously. We defined the dyssynchronous status as the sign (plus or minus) of the LV volume-change opposite to that of RV volume-change. Dyssynchronous phase of the cardiac cycle was observed in 5.6 ± 0.65% of hearts under LVAD pump-off and 25.3 ± 3.3% under LVAD full bypass, respectively (p < 0.05). To the best of our knowledge, this is the first experimental report clarifying interventricular dyssynchrony during CF-LVAD support using the conductance method. Quantification of this phenomenon under various support conditions and assessment of influences on the right ventricular function will be studied in future studies.


Subject(s)
Heart Failure/surgery , Heart-Assist Devices/adverse effects , Ventricular Function, Right/physiology , Animals , Diastole , Disease Models, Animal , Goats , Heart Failure/physiopathology , Heart Ventricles/physiopathology , Systole , Ventricular Dysfunction, Right/etiology , Ventricular Dysfunction, Right/physiopathology
15.
Article in English | MEDLINE | ID: mdl-38787287

ABSTRACT

Aortic root reconstruction during aortic root replacement for a patient with prosthetic valve endocarditis and aortic root abscess can be a difficult procedure with many possible complications. In this video case report, we describe our novel technique using a single bovine pericardial patch that avoids deep stitches or external sutures to support the friable annulus. Compared with more standard methods, this approach has shorter cross-clamp and cardiopulmonary bypass times and is less demanding technically.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Animals , Cattle , Humans , Male , Aortic Valve/surgery , Endocarditis/surgery , Endocarditis, Bacterial/surgery , Endocarditis, Bacterial/diagnosis , Heart Valve Prosthesis Implantation/methods , Pericardium/transplantation , Plastic Surgery Procedures/methods , Prosthesis-Related Infections/surgery , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/etiology , Aged
17.
Am J Cardiol ; 212: 13-22, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38008347

ABSTRACT

Hybrid coronary revascularization (HCR) is an alternative option to conventional coronary artery bypass grafting (CABG), but the long-term outcomes of HCR versus CABG remain unclear. We aimed to analyze the long-term outcomes after HCR and CABG for patients with multivessel coronary artery disease using meta-analysis. A systemic literature search of PubMed and EMBASE was performed from inception to March 2023. Studies reporting Kaplan-Meier curves with follow-up ≥1 year were included. The primary outcome was all-cause mortality, and the secondary outcomes were major adverse cardiac and cerebrovascular events (MACCEs) and repeat revascularization. In total, 13 studies (1 randomized controlled trial and 12 propensity-score matched observational studies) were analyzed. The mean follow-up period was 5.1 ± 3.1 years. HCR was associated with similar overall mortality (hazard ratio [HR] 1.09, 95% confidence interval [CI] 0.87 to 1.36), significantly higher incidence of MACCEs (HR 1.49, 95% CI 1.07 to 2.06), and repeat revascularization (HR 2.01, 95% CI 1.53 to 2.64) compared with CABG. In phase-specific analysis, the mortality rate was similar, and the incidence of repeat revascularization was higher in HCR regardless of phases. The incidence of MACCEs was higher in HCR during the mid-term phase (1 to 5 years), but it was similar during the long-term phase (long-term: ≥5 years). In conclusion, despite the higher incidence of MACCEs and repeat revascularization compared with CABG, HCR offered a similar long-term survival. Even longer-term follow-up and randomized controlled trials with a large population are warranted to investigate the role of HCR for multivessel coronary artery disease.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Coronary Artery Bypass/adverse effects , Incidence
18.
J Pers Med ; 14(3)2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38540978

ABSTRACT

The 2018 heart allocation system has significantly influenced heart transplantation and left ventricular assist device (LVAD) utilization. Our study aims to investigate age-related outcomes following LVAD implantation in the post-allocation era. Using the National Inpatient Sample, we analyzed data from 7375 patients who underwent LVAD implantation between 2019 and 2020. The primary endpoint was in-hospital mortality following LVAD implantation, stratified by age categories. The age groups were 18-49, 50-59, 60-69, and over 70. These represented 26%, 26%, 31%, and 17% of patients, respectively. Patients aged 60-69 and those over 70 exhibited higher in-hospital mortality rates of 12% and 17%, respectively, compared to younger age groups (7% for 18-49 and 6% for 50-59). The age groups 60-69 and over 70 were independent predictors of mortality, with adjusted odds ratios of 1.99 (p = 0.02; 95% confidence interval [CI], 1.12-3.57) and 2.88 (p = 0.002; 95% CI, 1.45-5.71), respectively. Additionally, a higher Charlson Comorbidity Index was associated with increased in-hospital mortality risk (adjusted odds ratio 1.39; p = 0.02; 95% CI, 1.05-1.84). Additionally, patients above 70 experienced a statistically shorter length of stay. Nonhome discharge was found to be significantly high across all age categories. However, the difference in hospitalization cost was not statistically significant across the age groups. Our study highlights that patients aged 60 and above face an increased risk of in-hospital mortality following LVAD implantation in the post-allocation era. This study sheds light on age-related outcomes and emphasizes the importance of considering age in LVAD patient selection and management strategies.

19.
J Am Heart Assoc ; 13(10): e033590, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38742529

ABSTRACT

BACKGROUND: The new heart allocation policy places veno-arterial extracorporeal membrane oxygenation (VA-ECMO)-supported heart transplant (HT) candidates at the highest priority status. Despite increasing evidence supporting left ventricular (LV) unloading during VA-ECMO, the effect of LV unloading on transplant outcomes following bridging to HT with VA-ECMO remains unknown. METHODS AND RESULTS: From October 18, 2018 to March 21, 2023, 624 patients on VA-ECMO at the time of HT were identified in the United Network for Organ Sharing database and were divided into 2 groups: VA-ECMO alone (N=384) versus VA-ECMO with LV unloading (N=240). Subanalysis was performed in the LV unloading group: Impella (N=106) versus intra-aortic balloon pump (N=134). Recipient age was younger in the VA-ECMO alone group (48 versus 53 years, P=0.018), as was donor age (VA-ECMO alone, 29 years versus LV unloading, 32 years, P=0.041). One-year survival was comparable between groups (VA-ECMO alone, 88.0±1.8% versus LV unloading, 90.4±2.1%; P=0.92). Multivariable Cox hazard model showed LV unloading was not associated with posttransplant mortality after HT (hazard ratio, 0.92; P=0.70). Different LV unloading methods had similar 1-year survival (intra-aortic balloon pump, 89.2±3.0% versus Impella, 92.4±2.8%; P=0.65). Posttransplant survival was comparable between different Impella versions (Impella 2.5, versus Impella CP, versus Impella 5.0, versus Impella 5.5). CONCLUSIONS: Under the current allocation policy, LV unloading did not impact waitlist outcome and posttransplant survival in patients bridged to HT with VA-ECMO, nor did mode of LV unloading. This highlights the importance of a tailored approach in HT candidates on VA-ECMO, where routine LV unloading may not be universally necessary.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Transplantation , Heart-Assist Devices , Humans , Extracorporeal Membrane Oxygenation/methods , Male , Female , Middle Aged , Adult , Ventricular Function, Left , Retrospective Studies , Tissue and Organ Procurement/methods , Treatment Outcome , United States/epidemiology , Heart Failure/physiopathology , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/surgery , Time Factors , Waiting Lists/mortality , Intra-Aortic Balloon Pumping
20.
Heart ; 110(5): 331-336, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-37648437

ABSTRACT

OBJECTIVE: Aortic dissection and aortic aneurysm rupture are aortic emergencies and their clinical outcomes have improved over the past two decades; however, whether this has translated into lower mortality across countries remains an open question. The purpose of this study was to compare mortality trends from aortic dissection and rupture between the UK, Japan, the USA and Canada. METHODS: We analysed the WHO mortality database to determine trends in mortality from aortic dissection and rupture in four countries from 2000 to 2019. Age-standardised mortality rates per 100 000 persons were calculated, and annual percentage change was estimated using joinpoint regression. RESULTS: Age-standardised mortality rates per 100 000 persons from aortic dissection and rupture in 2019 were 1.04 and 1.80 in the UK, 2.66 and 1.16 in Japan, 0.76 and 0.52 in the USA, and 0.67 and 0.81 in Canada, respectively. There was significantly decreasing trends in age-standardised mortality from aortic rupture in all four countries and decreasing trends in age-standardised mortality from aortic dissection in the UK over the study period. There was significantly increasing trends in mortality from aortic dissection in Japan over the study period. Joinpoint regression identified significant changes in the aortic dissection trends from decreasing to increasing in the USA from 2010 and Canada from 2012. In sensitivity analyses stratified by sex, similar trends were observed. CONCLUSIONS: Trends in mortality from aortic rupture are decreasing; however, mortality from aortic dissection is increasing in Japan, the USA and Canada. Further study to explain these trends is warranted.


Subject(s)
Aortic Dissection , Aortic Rupture , Humans , Japan/epidemiology , Canada/epidemiology , United Kingdom/epidemiology
SELECTION OF CITATIONS