Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Publication year range
1.
medRxiv ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38766063

ABSTRACT

Background: Human immunodeficiency virus (HIV) is associated with increased risk of heart failure (HF) but data regarding phenotypes of heart failure and outcomes after HF diagnosis, especially within the safety-net which is where half of people with HIV in the United States receive care, are less clear. Methods: Using an electronic health record cohort of all individuals with HF within a municipal safety-net system from 2001-2019 linked to the National Death Index Plus, we compared HF phenotypes, all-cause mortality, HF hospitalization, and cause of death for individuals with and without HIV. Results: Among people with HF (n=14,829), 697 individuals had HIV (4.7%). Persons with HIV (PWH) were diagnosed with HF ten years younger on average. A higher proportion of PWH had a reduced ejection fraction at diagnosis (37.9% vs 32.7%). Adjusted for age, sex, and risk factors, coronary artery disease on angiography was similar by HIV status. HIV was associated with 55% higher risk of all-cause mortality (HR 1.55; 95% CI 1.37-1.76; P<0.001) and lower odds of HF hospitalization (OR 0.51; 95% CI 0.39-0.66; P<0.001). Among PWH with HF, cause of death was less often attributed to cardiovascular disease (22.5% vs 54.6% uninfected; P<0.001) and more to substance use (17.9% vs 9.3%; P<0.001), consistent with autopsy findings in a subset (n=81). Conclusions: Among people with HF who receive care within a municipal safety-net system, HIV infection is associated with higher mortality, despite lower odds of HF hospitalization, attributable to non-cardiovascular causes including substance-related and HIV-related mortality.

2.
Adv Healthc Mater ; : e2401545, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38924692

ABSTRACT

While blood-contacting materials are widely deployed in medicine in vascular stents, catheters, and cannulas, devices fail in situ because of thrombosis and restenosis. Furthermore, microbial attachment and biofilm formation is not an uncommon problem for medical devices. Even incremental improvements in hemocompatible materials can provide significant benefits for patients in terms of safety and patency as well as substantial cost savings. Herein, a novel but simple strategy is described for coating a range of medical materials, that can be applied to objects of complex geometry, involving plasma-grafting of an ultrathin hyperbranched polyglycerol coating (HPG). Plasma activation creates highly reactive surface oxygen moieties that readily react with glycidol. Irrespective of the substrate, coatings are uniform and pinhole free, comprising O─C─O repeats, with HPG chains packing in a fashion that holds reversibly binding proteins at the coating surface. In vitro assays with planar test samples show that HPG prevents platelet adhesion and activation, as well as reducing (>3 log) bacterial attachment and preventing biofilm formation. Ex vivo and preclinical studies show that HPG-coated nitinol stents do not elicit thrombosis or restenosis, nor complement or neutrophil activation. Subcutaneous implantation of HPG coated disks under the skin of mice shows no evidence of toxicity nor inflammation.

3.
JAMA Intern Med ; 184(3): 324-325, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38190156

ABSTRACT

This case report describes a patient in their 60s with gastroesophageal reflex disease who presented to the emergency department after loss of consciousness during dinner and daily intermittent chest discomfort.


Subject(s)
Arrhythmias, Cardiac , Syncope , Humans , Syncope/diagnosis , Syncope/etiology