Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
Add more filters

Country/Region as subject
Publication year range
1.
J Card Fail ; 2024 Sep 17.
Article in English | MEDLINE | ID: mdl-39299541

ABSTRACT

INTRODUCTION: Optimal management of outpatients with heart failure (HF) requires serially updating the estimates of their risk for adverse clinical outcomes to guide treatment. Patient-reported outcomes (PROs) are becoming increasingly used in clinical care. The purpose of this study was to determine whether inclusion of PROs can improve the risk prediction for HF hospitalization and death in ambulatory HF patients. METHODS: We included consecutive patients with HF with reduced ejection fraction (HFrEF) and HF with preserved ejection fraction (HFpEF) seen in a HF clinic between 2015 and 2019 who completed PROs as part of routine care. Cox regression with a least absolute shrinkage and selection operator (LASSO) regularization and gradient boosting machine (GBM) analyses were used to estimate risk for a combined outcome of HF hospitalization, heart transplant, left ventricular assist device implantation or death. The performance of the prediction models was evaluated with the time-dependent concordance index (Cτ). RESULTS: Among 1165 patients with HFrEF (mean age 59.1±16.1, 68% male) the median follow-up was 487 days and among 456 patients with HFpEF (mean age: 64.2±16.0 years, 55% male) the median follow-up was 494 days. Gradient boosting regression that included PROs had the best prediction performance - Cτ 0.73 for patients with HFrEF and 0.74 in patients with HFpEF, and showed very good stratification of risk by time to event analysis by quintile of risk. The Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-12 OSS), Visual Analogue Scale (VAS) and Patient Reported Outcomes Measurement Information System (PROMIS) dimensions of Satisfaction with social roles and Physical function had high variable importance measure in the models. CONCLUSIONS: PROs improve risk prediction in both HFrEF and HFpEF, independent of traditional clinical factors. Routine assessment of PROs and leveraging the comprehensive data in the electronic health record in routine clinical care could help more accurately assess risk and support the intensification of treatment in patients with HF.

2.
Clin Transplant ; 38(5): e15330, 2024 May.
Article in English | MEDLINE | ID: mdl-38716787

ABSTRACT

INTRODUCTION: Since the 2018 change in the US adult heart allocation policy, more patients are bridged-to-transplant on temporary mechanical circulatory support (tMCS). Previous studies indicate that durable left ventricular assist devices (LVAD) may lead to allosensitization. The goal of this study was to assess whether tMCS implantation is associated with changes in sensitization. METHODS: We included patients evaluated for heart transplants between 2015 and 2022 who had alloantibody measured before and after MCS implantation. Allosensitization was defined as development of new alloantibodies after tMCS implant. RESULTS: A total of 41 patients received tMCS before transplant. Nine (22.0%) patients developed alloantibodies following tMCS implantation: 3 (12.0%) in the intra-aortic balloon pump group (n = 25), 2 (28.6%) in the microaxial percutaneous LVAD group (n = 7), and 4 (44.4%) in the veno-arterial extra-corporeal membrane oxygenation group (n = 9)-p = .039. Sensitized patients were younger (44.7 ± 11.6 years vs. 54.3 ± 12.5 years, p = .044), were more likely to be sensitized at baseline - 3 of 9 (33.3%) compared to 2 out of 32 (6.3%) (p = .028) and received more transfusions with red blood cells (6 (66.6%) vs. 8 (25%), p = .02) and platelets (6 (66.6%) vs. 5 (15.6%), p = .002). There was no significant difference in tMCS median duration of support (4 [3,15] days vs. 8.5 [5,14.5] days, p = .57). Importantly, out of the 11 patients who received a durable LVAD after tMCS, 5 (45.5%) became sensitized, compared to 4 out of 30 patients (13.3%) who only had tMCS-p = .028. CONCLUSIONS: Our findings suggest that patients bridged-to-transplant with tMCS, without significant blood product transfusions and a subsequent durable LVAD implant, have a low risk of allosensitization. Further studies are needed to confirm our findings and determine whether risk of sensitization varies by type of tMCS and duration of support.


Subject(s)
Heart Transplantation , Heart-Assist Devices , Isoantibodies , Humans , Male , Female , Middle Aged , Isoantibodies/immunology , Isoantibodies/blood , Follow-Up Studies , Adult , Risk Factors , Prognosis , Retrospective Studies , Heart Failure/surgery , Heart Failure/therapy , Graft Rejection/etiology
3.
Blood Press ; 31(1): 228-235, 2022 12.
Article in English | MEDLINE | ID: mdl-36123788

ABSTRACT

PURPOSE: We investigated whether blood pressure (BP) control measures, visit-to-visit BP variability, and time in therapeutic range (TTR) are associated with future cardiovascular outcomes in hypertensive patients. MATERIALS AND METHODS: Among 1,408 hypertensive patients without cardiovascular disease, we prospectively evaluated the incident major cardiovascular events over 6 years. In newly diagnosed patients, antihypertensive drug treatment was initiated. We estimated two markers of on-treatment BP control, (1) visit-to-visit BPV as the coefficient of variation of office systolic BP (BP-CV), and (2) TTR calculated as the percentage of office systolic BP measurements within 120-140mmHg across visits. RESULTS: The hypertensive cohort (672 males, mean age 60 years, 31% newly diagnosed) had a mean systolic/diastolic BP of 142/87 mmHg. The mean number of visits was 4.9 ± 2.6, while the mean attained systolic/diastolic BP during follow-up was 137/79 mmHg using 2.7 ± 1.1 antihypertensive drugs. The BP-CV and TTR were 9.1 ± 4.1% and 45 ± 29%, respectively, and the incidence of the composite outcome was 8.3% (n = 117). After adjustment for relevant confounders and standardization to z-scores, BP-CV and TTR were associated with a 43% (95% CI, 27-62%) increase and a 33% (95% CI, 15-47%) reduction in the outcome. However, the joint evaluation of TTR and BP-CV in a common multivariable model indicated that a standardized change of TTR was associated with the outcome to a greater extent than BP-CV (mean hazard ratios of 30% vs. 24%, respectively). When combined with the higher BP standardized-CV quartile, the lower TTR quartile predicted the outcome by 2.3 times (95% CI, 1.1-5.4) compared to the inverse TTR and BP-CV quartile pattern. CONCLUSION: High BP-CV or low TTR was associated with future cardiovascular events in a cohort of treated hypertensive patients. As a determinant, the extent of TTR value appears greater than BP-CV when these measures are considered in the same multivariable model.


Subject(s)
Cardiovascular Diseases , Hypertension , Antihypertensive Agents/pharmacology , Antihypertensive Agents/therapeutic use , Blood Pressure , Cardiovascular Diseases/etiology , Humans , Hypertension/complications , Hypertension/drug therapy , Male , Middle Aged , Prospective Studies , Risk Factors
4.
J Cardiovasc Electrophysiol ; 32(2): 491-499, 2021 02.
Article in English | MEDLINE | ID: mdl-33345428

ABSTRACT

INTRODUCTION: Transvenous lead extraction (TLE) is critical in the long-term management of patients with cardiac implanted electronic devices (CIEDs). The aim of the study is to evaluate the outcomes of TLE and to investigate the impact of infection. METHODS AND RESULTS: Data of patients undergoing extraction of permanent pacemaker and defibrillator leads during October 2014-September 2019 were prospectively analyzed. Overall, 242 consecutive patients (aged 71.0 ± 14.0 years, 31.4% female), underwent an equal number of TLE operations for the removal of 516 leads. Infection was the commonest indication (n = 201, 83.1%). Mean implant-to-extraction duration was 7.6 ± 5.4 years. Complete procedural success was recorded in 96.1%, and clinical procedural success was achieved in 97.1% of attempted lead extractions. Major complications occurred in two (0.8%) and minor complications in seven (2.9%) patients. Leads were removed exclusively by using locking stylets in 65.7% of the cases. In the subgroup of noninfective patients, advanced extraction tools were more frequently required compared to patients with CIED infections, to extract leads (success only with locking stylet: 55.8% vs. 67.8%, p = .032). In addition, patients without infection demonstrated lower complete procedural success rates (90.7% vs. 97.2%, p = .004), higher major complication rates (2.4% vs. 0.5%, p = .31) and longer procedural times (136 ± 13 vs. 111 ± 15 min, p = .001). CONCLUSIONS: Our data demonstrate high procedural efficacy and safety and indicate that in patients with noninfective indications, the procedure is more demanding, thus supporting the hypothesis that leads infection dissolves and/or prohibits the formation of fibrotic adherences.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Device Removal/adverse effects , Female , Humans , Male , Pacemaker, Artificial/adverse effects , Retrospective Studies , Treatment Outcome
5.
J Card Surg ; 36(4): 1298-1304, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33512725

ABSTRACT

OBJECTIVES: For tailored treatment of primary mitral regurgitation (MR), surgeons developed different repair techniques. One of them, the edge-to-edge repair has recently seen a revival, especially for Barlow's disease. METHODS: This study was designed to assess the outcomes of the edge-to-edge technique in mitral valve (MV) repair. Preoperative, periprocedural, and postoperative data were prospectively collected in a dedicated database and analyzed retrospectively. RESULTS: Between March 1999 and July 2019, a total of 152 patients (mean age: 60 ± 13) received an edge-to-edge repair combined with annuloplasty for degenerative MR at our institution. MR resulted from posterior leaflet prolapse in 23 patients (15.1%), anterior leaflet prolapse in 19 (12.5%), and bileaflet prolapse in 110 (72.4%). Of those who had a bileaflet prolapse, 91 (82.7%) had Barlow's disease. Follow-up was complete in 97.4% (6.4 ± 5.7 years). Echocardiographic assessment was achieved in 85.5% (5.1 ± 5.6 years). Overall survival after 10 years was 73.7 ± 5.0%. Twelve patients required valve-related reoperations due to ring dehiscence (n = 2), leaflet suture dehiscence (n = 2), progression of native valve disease (n = 6), or due to device failure (ring fracture) (n = 2). The cumulative incidence of valve-related reoperation at 10 years was 8.4 ± 3.0% (5.2 ± 4.1% in patients with Barlow's disease). At latest follow-up, echocardiography revealed excellent valve function with no or mild MR in 93 patients (88.6%). The mean gradient was 2.9 ± 1.3 mmHg at discharge and decreased to 2.4 ± 1.3 mmHg. Three patients (2.8%) had more than moderate MR. CONCLUSION: Edge-to-edge MV repair is a simple method with excellent results in terms of valvular function and durability especially in patients with Barlow's disease.


Subject(s)
Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Mitral Valve Prolapse , Aged , Humans , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Retrospective Studies , Treatment Outcome
6.
J Card Surg ; 36(12): 4537-4545, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34580919

ABSTRACT

BACKGROUND: The dual-filter Sentinel™ Cerebral Protection System (Sentinel-CPS) is increasingly used during transcatheter aortic valve replacement (TAVR). However, complex vascular anatomy may challenge Sentinel-CPS deployment. AIM OF THE STUDY: We sought to investigate the impact of anatomic features of the aortic arch and the supra-aortic arteries on technical device failure of Sentinel-CPS application. METHODS: Analysis of the multislice computed tomography pre-TAVR aortograms of all patients undergoing TAVR with Sentinel-CPS between 2016 and 2020 (n = 92) was performed. We investigated the impact of aortic arch anatomy, configuration, and the angles of the supra-aortic arteries, including the determination of vascular tortuosity index on device failure of Sentinel-CPS application. RESULTS: The Sentinel-CPS was applied successfully in 83 patients (90.2%). Device failure in nine patients (9.8%) was due to the infeasibility to perform correct deployment of both filters (n = 7) and to obtain peripheral radial access (n = 2). Patients with a failure of Sentinel-CPS application had a higher right subclavian tortuosity index (217 [92-324] vs. 150 [42-252], p = .046), a higher brachiocephalic tortuosity index (27 [5-51] vs. 10 [0-102], p = 0.033) and a larger angulation of the brachiocephalic artery (59° [22-80] vs. 39° [7-104], p = .014) compared with patients with successful application. A brachiocephalic angle more than 59° was predictive for device failure. No differences in aortic arch anatomy or common carotid artery tortuosity were detected between the groups. CONCLUSIONS: Brachiocephalic tortuosity was found to be associated with failure of Sentinel-CPS application. Filter-based usage should be avoided in TAVR patients with a brachiocephalic angle more than 59°.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Multidetector Computed Tomography , Prosthesis Design , Risk Factors , Treatment Outcome
7.
J Card Surg ; 36(4): 1241-1248, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33484180

ABSTRACT

PURPOSE: The Sentinel Cerebral Protection System (Sentinel-CPS) is increasingly used in transcatheter aortic valve replacement (TAVR). However, the impact of inserting the Sentinel-CPS inside the brain-supplying arteries on cerebral perfusion and oxygenation is unknown. METHODS: Twenty patients undergoing transfemoral TAVR with (n = 10) and without (n = 10) cerebral embolic protection using the Sentinel-CPS were prospectively observed. All patients received conscious sedation and cerebral oxygen saturation (rSO2 ) was continuously measured with near-infrared spectroscopy (NIRS). The cumulative perioperative cerebral desaturation was calculated for each patient by multiplying rSO2 below an individualized desaturation threshold by time. In addition, rSO2 values at the time of Sentinel-CPS insertion, filter positioning, and device retraction were analyzed. RESULTS: There was no significant difference in cumulative cerebral desaturation in patients with Sentinel-CPS (median [IQR]) (0 [0/81] s%) and without (median [IQR]) (0 [0/23] s%), p = .762. A total of 6 patients (33.3%) experienced a perioperative decrease in rSO2 below the individualized desaturation threshold (n = 3 with Sentinel-CPS, n = 3 without Sentinel-CPS; p = 1.000). Cerebral desaturation was detected during valve deployment (n = 5) and after postdilatation (n = 1). No desaturation events occurred during Sentinel-CPS insertion, filter positioning, or retraction. CONCLUSION: Our pilot study revealed no difference in cumulative perioperative cerebral desaturation between TAVR with and without Sentinel-CPS. Catheter- and filter-based manipulations in the brain-supplying arteries for Sentinel-CPS application were not associated with a decrease of cerebral perfusion and oxygenation.


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Oxygen , Pilot Projects , Prospective Studies , Treatment Outcome
8.
Artif Organs ; 44(12): 1259-1266, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32592601

ABSTRACT

The frequency of mechanical circulatory support (MCS) device application has increased in recent years. Besides implantation in the emergency setting, such as circulatory arrest, MCS is also increasingly used electively to ensure hemodynamic stability in high-risk patients, for example, during percutaneous coronary interventions (PCI), valve interventions or off-pump coronary bypass surgery. Lifebridge (Zoll Medical GmbH, Germany) is a compact percutaneous MCS device widely used in daily clinical routine. The present study aimed to investigate the indications, feasibility, and outcomes after use of Lifebridge in cardiac interventions, evaluating a large-scale multicenter database. A total of 60 tertiary cardiovascular centers were questioned regarding application and short-term outcomes after the use of the Lifebridge system (n = 160 patients). Out of these 60 centers, eight consented to participate in the study (n = 39 patients), where detailed data were collected using standardized questionnaires. Demographic and clinical characteristics of the patient population, procedural as well as follow-up data were recorded and analyzed. In 60 interrogated centers, Lifebridge was used in 74% of emergency cases and 26% in the setting of planned interventions. The subcohort interrogated in detail displayed the same distribution of application scenarios, while the main cardiovascular procedure was high-risk PCI (82%). All patients were successfully weaned from the device and 92% (n = 36) of the patients studied in detail survived after 30 days. As assessed 30 days after insertion of the device, bleeding requiring red blood cell (RBC) transfusion constituted the main complication, occurring in 49% of cases. In our analysis of clinical data, the use of Lifebridge in cardiac intervention was shown to be feasible. Further prospective studies are warranted to identify patients who benefit from hemodynamic MCS support despite the increased rate of RBC transfusion due to challenges in access sites during cardiovascular procedures.


Subject(s)
Blood Loss, Surgical/prevention & control , Extracorporeal Membrane Oxygenation/statistics & numerical data , Intraoperative Care/methods , Postoperative Hemorrhage/epidemiology , Aged , Blood Loss, Surgical/statistics & numerical data , Coronary Artery Bypass, Off-Pump/adverse effects , Coronary Artery Bypass, Off-Pump/statistics & numerical data , Erythrocyte Transfusion/statistics & numerical data , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Feasibility Studies , Female , Follow-Up Studies , Germany/epidemiology , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/statistics & numerical data , Hospital Mortality , Humans , Intraoperative Care/adverse effects , Intraoperative Care/statistics & numerical data , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Postoperative Hemorrhage/etiology , Postoperative Hemorrhage/therapy , Prospective Studies , Registries/statistics & numerical data , Tertiary Care Centers/statistics & numerical data , Treatment Outcome
9.
Thorac Cardiovasc Surg ; 68(7): 616-622, 2020 10.
Article in English | MEDLINE | ID: mdl-31091551

ABSTRACT

BACKGROUND: There is a growing use of cerebral protection devices in patients undergoing transcatheter aortic valve replacement (TAVR). We aimed to analyze if the use of these devices itself has an impact on the complexity and the risk of TAVR. METHODS: Between February 2016 and July 2017, 391 patients underwent transfemoral TAVR with Medtronic CoreValve Evolut R (n = 196) or Edwards Sapien 3 (n = 195). In 39 patients, the Claret Sentinel™ embolic protection device (CS-EPD) was used. Prospectively collected data were retrospectively analyzed, comparing fluoroscopy/operation time, amount of contrast used, vascular events, and postprocedural renal function in TAVR patients with (n = 39) and without (n = 352) CS-EPD. RESULTS: The CS-EPD was placed through the right radial (n = 35) or brachial (n = 4) artery. Procedural success rate defined as correct deployment and retraction of both filters was 94.9%. No device-related vascular complications occurred. TAVR patients with CS-EPD showed a significantly higher total operation time, total fluoroscopy time, and amount of used contrast (85.4 ± 39.3 vs. 64 ± 29.8 minutes, p = 0.002; 20.7 ± 9.3 vs. 13.7 ± 7 minutes, p ≤ 0.001; 133.7 ± 42.6 vs. 109.7 ± 44.5 mL, p = 0.001). Comparing the initial third of patients receiving a CS-EPD with the last third of CS-EPD cases, procedural time had decreased significantly (102.5 ± 34.9 vs. 67 ± 11.9; p = 0.002). There were no differences in postprocedural renal failure (p = 0.80). CONCLUSION: Our data add evidence that the application of the CS-EPD is not associated with an additional risk for the patient. Although procedural time and amount of contrast are still higher when using the CS-EPD, there were no device-related complications or increased incidence of renal failure.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Embolic Protection Devices , Heart Valve Prosthesis , Intracranial Embolism/prevention & control , Transcatheter Aortic Valve Replacement/instrumentation , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Hemodynamics , Humans , Intracranial Embolism/etiology , Male , Operative Time , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
Thorac Cardiovasc Surg ; 68(6): 470-477, 2020 09.
Article in English | MEDLINE | ID: mdl-31546265

ABSTRACT

BACKGROUND: Three-dimensional saddle-shaped annuloplasty rings have been shown to create a larger surface of leaflet coaptation in mitral valve repair (MVR) for functional mitral regurgitation (FMR) and degenerative mitral regurgitation (DMR) which may increase repair durability. For the first time, this study reports mid-term results after MVR for DMR and FMR using a rigid three-dimensional ring (Profile 3D, Medtronic). METHODS: Between June 2009 and June 2012, 369 patients with DMR (n = 326) or FMR (n = 43) underwent MVR (mean age 62.3 ± 12.6 years). A total of 205 patients (55.6%) underwent isolated MVR and 164 patients (44.4%) a combined procedure. Follow-up examinations were performed in 94.9% (mean 4.9 ± 0.9 years). Echocardiographic assessment was complete in 93.2% (mean 4.3 ± 1.2 years). RESULTS: The 30-day mortality was 1.5% (5/326) for DMR (1.5% for isolated and 1.6% for combined procedures) and 9.3% (4/43) for FMR (0% for isolated and 10.5% for combined procedures). Survival at 6 years was 92.1 ± 1.9% for DMR (92.9 ± 2.6% for isolated and 90.7 ± 2.7% for combined procedures) and 66.4 ± 7.9% for FMR (80.0 ± 17.9% for isolated and 63.7 ± 8.9% for combined procedures). Cumulative risk for mitral valve-related reoperation at 6 years was 0% for FMR and 7.1 ± 1.5% for DMR. At echocardiographic follow-up, one patient presented with mitral regurgitation (MR) more than moderate. The only predictor of recurrent MR after MVR for DMR was residual mild MR at discharge. CONCLUSION: Repair of FMR with the three-dimensional Profile 3D annuloplasty ring shows excellent mid-term results with regard to recurrence of MR. In cases of DMR, the results are conforming to the current literature.


Subject(s)
Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve Annuloplasty/instrumentation , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Aged , Aged, 80 and over , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/mortality , Hemodynamics , Humans , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/physiopathology , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Annuloplasty/mortality , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/mortality , Mitral Valve Insufficiency/physiopathology , Postoperative Complications/mortality , Prosthesis Design , Recovery of Function , Recurrence , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
11.
J Cardiovasc Electrophysiol ; 30(3): 299-307, 2019 03.
Article in English | MEDLINE | ID: mdl-30516299

ABSTRACT

INTRODUCTION: Cardiac perforation of the right ventricle associated with pacemaker or implantable cardioverter defibrillator (ICD) leads' implantation is uncommon, albeit potentially life-threatening, complication. The aim of this study is to further identify the optimal therapeutic strategy, especially when lead dislocation has occurred outside the pericardial sac. METHODS AND RESULTS: The study population included 10 consecutive patients (six female, mean age: 66.5 years old) diagnosed with early ventricular lead perforation following a pacemaker or ICD implantation, with significant protrusion inside the pericardial sac (n = 2) or migration of the lead at the pleural space ( n = 3), the diaphragm ( n = 1), or the abdominal cavity ( n = 4), during the period 2013-2017. All patients were symptomatic; however, individuals presenting with hemodynamic instability were excluded. The outcome of the percutaneous therapeutic approach was retrospectively assessed. All patients underwent a successful removal of the perforating lead percutaneously at the electrophysiology lab, by direct traction, and repositioning in another location of the right ventricle. The operation was performed by a multidisciplinary team, under continuous hemodynamic and transesophageal echocardiographic monitoring and cardiac surgical backup. The periprocedural period was uneventful. Subjects were followed up for at least 1 year. Interestingly, all patients developed a type of postcardiac injury syndrome, successfully treated with a 3-month regimen of ibuprofen and colchicine. CONCLUSION: Percutaneous traction and repositioning of the perforating ventricular lead are effective, safe, and less invasive compared with the thoracotomy method in hemodynamically stable patients when dislocation has occurred outside the pericardial sac provided that there is no visceral organs injury.


Subject(s)
Defibrillators, Implantable , Device Removal , Foreign-Body Migration/surgery , Heart Injuries/surgery , Heart Ventricles/surgery , Pacemaker, Artificial , Prosthesis Implantation/instrumentation , Aged , Aged, 80 and over , Device Removal/adverse effects , Female , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Heart Injuries/diagnostic imaging , Heart Injuries/etiology , Heart Ventricles/diagnostic imaging , Heart Ventricles/injuries , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis Implantation/adverse effects , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
15.
Eur Heart J ; 36(47): 3370-9, 2015 Dec 14.
Article in English | MEDLINE | ID: mdl-26314688

ABSTRACT

BACKGROUND: The majority of transcatheter aortic valve implantation (TAVI) procedures are currently performed by percutaneous transfemoral approach. The potential contribution of the type of vascular closure device to the incidence of vascular complications is not clear. AIM: To compare the efficacy of a Prostar XL- vs. Perclose ProGlide-based vascular closure strategy. METHODS: The ClOsure device iN TRansfemoral aOrtic vaLve implantation (CONTROL) multi-center study included 3138 consecutive percutaneous transfemoral TAVI patients, categorized according to vascular closure strategy: Prostar XL- (Prostar group) vs. Perclose ProGlide-based vascular closure strategy (ProGlide group). Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics. RESULTS: Propensity matching identified 944 well-matched patients (472 patient pairs). Composite primary end point of major vascular complications or in-hospital mortality occurred more frequently in Prostar group when compared with ProGlide group (9.5 vs. 5.1%, P = 0.016), and was driven by higher rates of major vascular complication (7.4 vs. 1.9%, P < 0.001) in the Prostar group. However, in-hospital mortality was similar between groups (4.9 vs. 3.5%, P = 0.2). Femoral artery stenosis occurred less frequently in the Prostar group (3.4 vs. 0.5%, P = 0.004), but overall, Prostar use was associated with higher rates of major bleeding (16.7 vs. 3.2%, P < 0.001), acute kidney injury (17.6 vs. 4.4%, P < 0.001) and with longer hospital stay (median 6 vs. 5 days, P = 0.007). CONCLUSIONS: Prostar XL-based vascular closure in transfemoral TAVI procedures is associated with higher major vascular complication rates when compared with ProGlide; however, in-hospital mortality is similar with both devices.


Subject(s)
Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Vascular Closure Devices/adverse effects , Vascular Diseases/etiology , Acute Kidney Injury/etiology , Aged , Aged, 80 and over , Cardiology/standards , Clinical Competence/standards , Constriction, Pathologic/etiology , Female , Femoral Artery , Humans , Learning Curve , Male , Myocardial Infarction/etiology , Postoperative Hemorrhage/etiology , Stroke/etiology , Transcatheter Aortic Valve Replacement/instrumentation
16.
Cureus ; 16(6): e62623, 2024 Jun.
Article in English | MEDLINE | ID: mdl-39027769

ABSTRACT

Cardiac amyloidosis is an infiltrative disease characterized by the extracellular deposition of misfolded protein in the myocardium, leading to increased stiffness and an eventual restrictive cardiomyopathy. The slow onset of symptoms and overlap with other cardiomyopathies make prompt diagnosis a challenge. Clinicians should be alerted and include amyloidosis in their differential diagnosis, particularly in patients with heart failure with preserved ejection fraction, unexplained left ventricle hypertrophy, particularly in those shown intolerance to previous antihypertensive medication, and early orthopedic manifestations of the disease such as carpal tunnel syndrome and spinal stenosis. The workup requires the exclusion of monoclonal gammopathies and technetium-99m pyrophosphate nuclear scintigraphy (99mTc-PYP) studies with single-photon emission computerized tomography (SPECT) imaging. Several therapies are now available and can prolong life with significantly improved quality of life, particularly when the diagnosis of amyloidosis is made early. We present the case of a 77-year-old with a delayed diagnosis by five years to highlight the need for heightened clinical suspicion and an appropriate diagnostic algorithm for cardiac amyloidosis.

17.
Methodist Debakey Cardiovasc J ; 20(4): 88-97, 2024.
Article in English | MEDLINE | ID: mdl-39184165

ABSTRACT

The 12th annual Utah Cardiac Recovery Symposium (U-CARS) in 2024 continued its mission to advance cardiac recovery by uniting experts across various fields. The symposium featured key presentations on cutting-edge topics such as CRISPR gene editing for heart failure, guideline-directed medical therapy for heart failure (HF) with improved/recovered ejection fraction (HFimpEF), the role of extracorporeal cardiopulmonary resuscitation (ECPR) in treating cardiac arrest, and others. Discussions explored genetic and metabolic contributions to HF, emphasized the importance of maintaining pharmacotherapy in HFimpEF to prevent relapse, and identified future research directions including refining ECPR protocols, optimizing patient selection, and leveraging genetic insights to enhance therapeutic strategies.


Subject(s)
Cardiopulmonary Resuscitation , Heart Failure , Recovery of Function , Animals , Humans , Cardiopulmonary Resuscitation/methods , Extracorporeal Membrane Oxygenation , Gene Editing , Heart Arrest/therapy , Heart Arrest/physiopathology , Heart Arrest/diagnosis , Heart Failure/physiopathology , Heart Failure/therapy , Heart Failure/diagnosis , Stroke Volume , Treatment Outcome , Utah , Ventricular Function, Left
18.
Ann Thorac Surg ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38851414

ABSTRACT

BACKGROUND: Patient-prosthesis mismatch (PPM) after aortic valve replacement potentially affects the outcome after the operation. This study sought to determine whether PPM has an impact on long-term mortality and reoperation rates. METHODS: We included 645 patients who underwent biologic aortic valve replacement between 2000 and 2007. Based on echocardiographic examinations at postoperative month 6, the incidence of PPM was determined according to an indexed effective orifice area <0.85 cm2/m2. Survival and reoperation status were analyzed during 15 years of follow-up. RESULTS: PPM was present in 256 patients (40%), of whom 175 had moderate PPM and 81 had severe PPM. In multivariable adjusted analysis, survival was not statistically significantly impaired in patients with moderate PPM compared with patients with no PPM, whereas patients with severe PPM showed a marginally significant impairment of survival (hazard ratio [HR], 1.40; 95% CI, 0.99-1.97; P = .054). Risk factors for survival were higher age (HR, 1.12; 95% CI, 1.10-1.14; P < .001), arterial hypertension (HR, 1.78; 95% CI, 1.38-2.31; P < .001), and diabetes mellitus (HR, 1.67; 95% CI, 1.31-2.14; P < .001). In patients with no, moderate, and severe PPM, there were 10.1, 8.5, and 14.8 events of reoperation/1000 patient-years, respectively. The corresponding 10-year cumulative incidence of reoperation was 8.3%, 6.7%, and 12.1%, respectively. In multivariable adjusted analysis, PPM category was not significantly associated with the risk of reoperation (P > .2). CONCLUSIONS: In our study with directly measured effective orifice area, PPM was only marginally related to long-term survival and was not statistically significantly associated with the risk of reintervention.

19.
J Clin Med ; 13(11)2024 May 31.
Article in English | MEDLINE | ID: mdl-38892978

ABSTRACT

Objectives: The optimal surgical approach for the treatment of functional mitral regurgitation (FMR) remains controversial. Current guidelines suggest that the surgical approach has to be tailored to the individual patient. The aim of the present study was to clarify further aspects of this tailored treatment. Methods: From 01/2006 to 12/2015, 390 patients underwent mitral valve (MV) surgery for FMR (ischemic n = 241, non-ischemic n = 149) at our institution. A regression analysis was used to determine the effect of MV repair or replacement on survival. The patients were analyzed according to the etiology of the MR (ischemic or non-ischemic), different age groups (<65 years, 65-75 years, and >75 years), LV function, and LV dimensions, as well as the underlying heart rhythm. Results: The overall survival rates for the repair group at 1, 5, and 8 years were 86.1 ± 1.9%, 70.6 ± 2.6%, and 55.1 ± 3.1%, respectively. For the same intervals, the survival rates in patients who underwent MV replacement were 75.9 ± 4.5%, 58.6 ± 5.4%, and 40.9 ± 6.4%, respectively (p = 0.003). Patients younger than 65 years, with an ischemic etiology of FMR, poor ejection fraction (<30%), severe dilatation of left ventricle (LVEDD > 60mm), and presence of atrial fibrillation had significantly higher mortality rates after MV replacement (HR, 3.0; CI, 1.3-6.9; p = 0.007). Patients between 65 and 75 years of age had a higher risk of death when undergoing mitral valve replacement (HR, 1.7; CI, 1.0-2.8; p = 0.04). In patients older than 75 years, the surgical approach (MV repair or replacement) had no effect on postoperative survival (HR, 0.8; CI, 0.4-1.3; p = 0.003). Conclusions: Our data demonstrate that, in patients younger than 65 years, the treatment of choice for FMR should be MV repair. This advantage was even more evident in patients with an ischemic origin of MR, a poor ejection fraction, a severe LV dilatation, and atrial fibrillation.

20.
J Clin Med ; 13(10)2024 May 13.
Article in English | MEDLINE | ID: mdl-38792411

ABSTRACT

Background: Centrifugal-flow left ventricular assist devices (CF-LVADs) have improved morbidity and mortality for their recipients. Hospital readmissions remain common, negatively impacting quality of life and survival. We sought to identify risk factors associated with hospital readmissions among patients with CF-LVADs. Methods: Consecutive patients receiving a CF-LVAD between February 2011 and March 2021 were retrospectively evaluated using prospectively maintained institutional databases. Hospital readmissions within three years post-LVAD implantation were dichotomized into heart failure (HF)/LVAD-related or non-HF/LVAD-related readmissions. Multivariable Cox regression models augmented using a machine learning algorithm, the least absolute shrinkage and selection operator (LASSO) method, for variable selection were used to estimate associations between HF/LVAD-related readmissions and pre-, intra- and post-operative clinical variables. Results: A total of 204 CF-LVAD recipients were included, of which 138 (67.7%) had at least one HF/LVAD-related readmission. HF/LVAD-related readmissions accounted for 74.4% (436/586) of total readmissions. The main reasons for HF/LVAD-related readmissions were major bleeding, major infection, HF exacerbation, and neurological dysfunction. Using pre-LVAD variables, HF/LVAD-related readmissions were associated with substance use, previous cardiac surgery, HF duration, pre-LVAD inotrope dependence, percutaneous LVAD/VA-ECMO support, LVAD type, and the left ventricular ejection fraction in multivariable analysis (Harrell's concordance c-statistic; 0.629). After adding intra- and post-operative variables in the multivariable model, LVAD implant hospitalization length of stay was an additional predictor of readmission. Conclusions: Using machine learning-based techniques, we generated models identifying pre-, intra-, and post-operative variables associated with a higher likelihood of rehospitalizations among patients on CF-LVAD support. These models could provide guidance in identifying patients with increased readmission risk for whom clinical strategies to mitigate this risk may further improve LVAD recipient outcomes.

SELECTION OF CITATIONS
SEARCH DETAIL