1.
J Synchrotron Radiat ; 26(Pt 6): 2081-2085, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31721754

ABSTRACT

The transmission of the optical components of the Bernina branch of the Aramis beamline at SwissFEL has been measured with an X-ray gas monitor from DESY and compared with a PSI gas detector upstream of the optical components. The transmission efficiencies of the Mo, Si and SiC mirror coatings of the Aramis beamline and the various other in-beam components were evaluated and compared with theoretical calculations, showing an agreement of 6% or better in all cases. The experiment has also shown the efficacy of the high-harmonic rejection mirrors at the Bernina branch of the Aramis beamline at SwissFEL, and characterized the transmission efficiency of the on-line spectrometer in the Aramis beamline. The theoretical transmission of the mirror coatings match the experimental data to within 7%. The accuracy of these measurements was checked against a radiative bolometer from a Japanese collaboration and found to agree to a level of 4% or better. Further comparisons with a diamond detector from a US-based inter-institute collaboration demonstrated a good agreement for the attenuator settings of the beamline.

2.
J Synchrotron Radiat ; 25(Pt 4): 1060-1067, 2018 Jul 01.
Article in English | MEDLINE | ID: mdl-29979167

ABSTRACT

Diamond X-ray detectors with conducting nitrogen-incorporated ultra-nanocrystalline diamond (N-UNCD) films as electrodes were fabricated to measure X-ray beam flux and position. Structural characterization and functionality tests were performed for these devices. The N-UNCD films grown on unseeded diamond substrates were compared with N-UNCD films grown on a seeded silicon substrate. The feasibility of the N-UNCD films acting as electrodes for X-ray detectors was confirmed by the stable performance in a monochromatic X-ray beam. The fabrication process is able to change the surface status which may influence the signal uniformity under low bias, but this effect can be neglected under full collection bias.

3.
J Synchrotron Radiat ; 22(6): 1396-402, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26524304

ABSTRACT

Fabrication and testing of a prototype transmission-mode pixelated diamond X-ray detector (pitch size 60-100 µm), designed to simultaneously measure the flux, position and morphology of an X-ray beam in real time, are described. The pixel density is achieved by lithographically patterning vertical stripes on the front and horizontal stripes on the back of an electronic-grade chemical vapor deposition single-crystal diamond. The bias is rotated through the back horizontal stripes and the current is read out on the front vertical stripes at a rate of ∼ 1 kHz, which leads to an image sampling rate of ∼ 30 Hz. This novel signal readout scheme was tested at beamline X28C at the National Synchrotron Light Source (white beam, 5-15 keV) and at beamline G3 at the Cornell High Energy Synchrotron Source (monochromatic beam, 11.3 keV) with incident beam flux ranges from 1.8 × 10(-2) to 90 W mm(-2). Test results show that the novel detector provides precise beam position (positional noise within 1%) and morphology information (error within 2%), with an additional software-controlled single channel mode providing accurate flux measurement (fluctuation within 1%).


Subject(s)
Diamond/chemistry , Diamond/radiation effects , Radiometry/instrumentation , Signal Processing, Computer-Assisted/instrumentation , Transducers , X-Ray Diffraction/instrumentation , Dose-Response Relationship, Radiation , Equipment Design , Equipment Failure Analysis , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity
4.
J Synchrotron Radiat ; 19(Pt 3): 381-7, 2012 May.
Article in English | MEDLINE | ID: mdl-22514173

ABSTRACT

Two transmission-mode diamond X-ray beam position monitors installed at National Synchrotron Light Source (NSLS) beamline X25 are described. Each diamond beam position monitor is constructed around two horizontally tiled electronic-grade (p.p.b. nitrogen impurity) single-crystal (001) CVD synthetic diamonds. The position, angle and flux of the white X-ray beam can be monitored in real time with a position resolution of 500 nm in the horizontal direction and 100 nm in the vertical direction for a 3 mm × 1 mm beam. The first diamond beam position monitor has been in operation in the white beam for more than one year without any observable degradation in performance. The installation of a second, more compact, diamond beam position monitor followed about six months later, adding the ability to measure the angular trajectory of the photon beam.


Subject(s)
Synchrotrons/instrumentation , Diamond/chemistry , Equipment Design , X-Rays
5.
J Synchrotron Radiat ; 17(6): 711-8, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20975215

ABSTRACT

High-quality single-crystal and polycrystalline chemical-vapor-deposition diamond detectors with platinum contacts have been tested at the white-beam X28C beamline at the National Synchrotron Light Source under high-flux conditions. The voltage dependence of these devices has been measured under both DC and pulsed-bias conditions, establishing the presence or absence of photoconductive gain in each device. Linear response consistent with the theoretically determined ionization energy has been achieved over eleven orders of magnitude when combined with previous low-flux studies. Temporal measurements with single-crystal diamond detectors have resolved the nanosecond-scale pulse structures of both the NSLS and the APS. Prototype single-crystal quadrant detectors have provided the ability to simultaneously resolve the X-ray beam position and obtain a quantitative measurement of the flux.


Subject(s)
Synchrotrons/instrumentation , Calibration , Diamond , Equipment Design , Radiometry/methods , X-Rays
6.
Phys Rev Lett ; 105(16): 164801, 2010 Oct 15.
Article in English | MEDLINE | ID: mdl-21230979

ABSTRACT

The diamond amplifier (DA) is a new device for generating high-current, high-brightness electron beams. Our transmission-mode tests show that, with single-crystal, high-purity diamonds, the peak current density is greater than 400 mA/mm², while its average density can be more than 100 mA/mm². The gain of the primary electrons easily exceeds 200, and is independent of their density within the practical range of DA applications. We observed the electron emission. The maximum emission gain measured was 40, and the bunch charge was 50 pC/0.5 mm². There was a 35% probability of the emission of an electron from the hydrogenated surface in our tests. We identified a mechanism of slow charging of the diamond due to thermal ionization of surface states that cancels the applied field within it. We also demonstrated that a hydrogenated diamond is extremely robust.

7.
AIP Adv ; 10(2): 025004, 2020 Feb.
Article in English | MEDLINE | ID: mdl-32128286

ABSTRACT

Diamond, a highly radiation-resistant material, is considered a nearly ideal material for radiation detection, particularly in high-energy physics. In this study, radiation damage from high-energy proton beams was induced in diamond crystals to determine exposure lifetime in detectors made from this material; the effects were investigated using non-destructive x-ray techniques and through the FLUKA simulation package. Two diamond detectors were irradiated by an 800 MeV proton beam at different fluence rates, and the real-time current response was recorded to observe degradation in the signal over time. It was determined that the proton fluence rate had a significant effect on the device degradation. The detector performance from the irradiated detectors was characterized using x-ray beam-induced current measurements, and the mechanism of proton radiation damage to diamond sensors, especially the radiation effects on carrier transport, was studied. The vacancies generated from proton irradiation were considered the major source of detector degradation by trapping holes and inducing an internal electric field. Simulation results from the FLUKA package revealed an uneven distribution of the radiation-induced vacancies along the beam path, and the corresponding detector signals calculated from the simulation results displayed a good match to the experimental results.

8.
J Phys Chem A ; 112(39): 9526-30, 2008 Oct 02.
Article in English | MEDLINE | ID: mdl-18636703

ABSTRACT

Collisional deactivation of the 5d7p (3)D1 state of Ba by noble gases is studied by time- and wavelength-resolved fluorescence techniques. A pulsed, frequency-doubled dye laser at 273.9 nm excites the 5d7p (3)D1 level from the ground state, and fluorescence at 364.1 and 366.6 nm from the 5d7p (3)D1 --> 6s5d (3)D1 and 5d7p (3)D1 --> 6s5d (3)D2 transitions, respectively, is monitored in real time to obtain the deactivation rate constants. At 835 K these rate constants are as follows: He, (1.69 +/- 0.08) x 10(-9) cm(3) s(-1); Ne, (3.93 +/- 0.14) x 10(-10) cm(3) s(-1); Ar, (4.53 +/- 0.15) x 10(-10) cm(3) s(-1); Kr, (4.64 +/- 0.13) x 10(-10) cm(3) s(-1); Xe, (5.59 +/- 0.22) x 10(-10) cm(3) s(-1). From time-resolved 5d7p (3)D1 emission in the absence of noble gas and from the intercepts of the quenching plots, the lifetime of this state is determined to be 100 +/- 1 ns. Using time- and wavelength-resolved Ba emission with a low background pressure of noble gas, radiative lifetimes of several near-resonant states are determined from the exponential rise of the fluorescence signals. These results are as follows: 5d6d (3)D3, 28 +/- 3 ns; 5d7p (3)P1, 46 +/- 2 ns; 5d6d (3)G3, 21.5 +/- 0.8 ns; 5d7p (3)F3, 48 +/- 1 ns. Integrated fluorescence signals are used to infer the relative rate constants for population transfer from the 5d7p (3)D1 state to eleven near-resonant fine structure states.


Subject(s)
Barium/chemistry , Energy Transfer , Noble Gases/chemistry , Fluorescence , Models, Chemical , Time Factors
9.
Rev Sci Instrum ; 82(3): 033113, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21456724

ABSTRACT

We report formation of subwavelength surface grating over large surface area of molybdenum mirror by multiple irradiation of amplified femtosecond laser pulses from a homemade Ti:sapphire oscillator-amplifier laser system in a raster scan configuration. The laser system delivered 2 mJ, 80 fs duration laser pulses at a pulse repetition rate of 10 Hz. Various parameters such as pulse fluence, number of pulses, laser polarization, scan speed, and scan steps were optimized to obtain uniform subwavelength gratings. Energy dispersive x-ray spectroscopy measurements were conducted to analyze the elemental composition of mirror surfaces before and after laser treatment.

10.
Nucl Instrum Methods Phys Res A ; 649(1): 91-93, 2011 Sep 01.
Article in English | MEDLINE | ID: mdl-21822344

ABSTRACT

High purity, single crystal CVD diamond plates are screened for quality and instrumented into a sensor assembly for quantitative characterization of flux and position sensitivity. Initial investigations have yielded encouraging results and have led to further development. Several limiting complications are observed and discussed, as well as mitigations thereof. For example, diamond quality requirements for x-ray diodes include low nitrogen impurity and crystallographic defectivity. Thin electrode windows and electronic readout performance are ultimately also critical to device performance. Promising features observed so far from prototype devices include calculable responsivity, flux linearity, position sensitivity and timing performance. Recent results from testing in high flux and high speed applications are described.