Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
Add more filters

Publication year range
1.
Int J Dent Hyg ; 22(4): 959-970, 2024 Nov.
Article in English | MEDLINE | ID: mdl-38659231

ABSTRACT

OBJECTIVE: The aim of this randomized controlled trial was to assess clinical and patient reported outcomes of subgingival instrumentation (SI) with adjunctive use of diode laser (DL) versus SI alone in the treatment of periodontitis. METHODS: Participants requiring non-surgical periodontal treatment were randomly allocated into two treatment groups: SI with DL or SI alone. Clinical parameters [full mouth bleeding and plaque scores (FMBS and FMPS), probing pocket depth and clinical attachment level] were recorded at baseline, three and 6 months post-treatment. Visual analogue scale was used to evaluate postoperative participants' perception of pain, swelling, bleeding, bruising and root sensitivity. The impact of periodontal treatment on quality of life was assessed using the General Oral Health Assessment Index (GOHAI) at 6 months. RESULTS: A total of 22 participants with stage III/IV periodontitis completed the 6-month follow-up. SI with or without DL resulted in statistically significant reduction in FMBS, FMPS, PPDs, and percentage of PPDs of ≥5 mm at 3- and 6-month follow-up visits (p = 0.001 to <0.001). The participants in SI/DL group had a greater reduction in the percentage of deep PPDs (≥5 mm) compared to those receiving SI alone, but statistically significant differences between the two groups were not observed (16.40 ± 9.57 vs. 32.50 ± 38.76 at 3 months and 7.20 ± 6.86 vs. 19.50 ± 35.06 at 6 months). The difference in the mean total GOHAI scores was not statistically significant at 6 months with total GOHAI scores of 7.25 ± 2.45 and 5.40 ± 3.06 for SI and SI/DL groups, respectively. CONCLUSION: Within the limitations of this study, the use of DL as an adjunct to SI in the treatment of stage III/IV periodontitis did not produce significant additional improvement in clinical parameters or patient reported outcomes in the 6-month observation period.


Subject(s)
Lasers, Semiconductor , Periodontitis , Quality of Life , Humans , Lasers, Semiconductor/therapeutic use , Female , Male , Adult , Middle Aged , Periodontitis/therapy , Treatment Outcome , Periodontal Index , Dental Scaling/methods , Pain Measurement
2.
Eur J Dent Educ ; 26(3): 459-467, 2022 Aug.
Article in English | MEDLINE | ID: mdl-34543521

ABSTRACT

BACKGROUND: COVID-19 pandemic has led to major life changes including suspension of dental education programmes worldwide. The impact of this unexpected disruption in clinical teaching needs to be assessed. AIM: The aim of this study was to evaluate the impact of the COVID-19 restriction measures on the undergraduate dental students' perception regarding their physical, mental and social well-being as well as financial stress and anxiety for their future careers. MATERIALS AND METHODS: An electronic questionnaire (Qualtrics, Provo, Utah, USA) with main themes (general well-being, academic stressors, financial implications and dental career concerns) related to the COVID-19 lockdown was sent to the undergraduate dental students at the University Of Otago, New Zealand. Participants were asked to rank their answers according to a 5-level Likert scale (strongly disagreed-strongly agreed). Other questions included demographic, fee-paying status and living situation. RESULTS: There were 301 out of 376 students who responded to the survey. Generally, the students perceived that the COVID-19 restrictions affected their behavioural and social well-being (3.20 ± 0.75) and less impact on their physical (2.75 ± 0.82) and psychological (2.79 ± 0.62) well-being. Students were significantly worried about their academic work and future careers (3.41 ± 1.20), but less concerned with their financial situation (2.74 ± 1.14). CONCLUSIONS: The study provides valuable information on the impact of COVID-19 pandemic on undergraduate dental students, and areas that the University should consider when providing support to the affected students. It is important that the University is proactive and prepared to deal with future pandemics effectively and efficiently.


Subject(s)
COVID-19 , Adaptation, Psychological , Communicable Disease Control , Education, Dental , Humans , Pandemics , Students, Dental , Surveys and Questionnaires
3.
Clin Oral Implants Res ; 28(1): 116-125, 2017 Jan.
Article in English | MEDLINE | ID: mdl-26799154

ABSTRACT

OBJECTIVE: To determine implant survival and prosthodontic maintenance of implant-assisted mandibular removable partial dentures in a multicentre prospective study up to 10 years. MATERIALS AND METHODS: Forty-eight participants with mandibular distal extension partial dentures were selected. A control group of 12 New Zealand participants had new conventional mandibular partial dentures made. Three test groups of 36 participants in New Zealand (n = 12), the Netherlands (n = 12) and Colombia (n = 12) had bilateral distal implants placed. Surgical and prosthodontic outcomes were documented with only healing caps placed (Stage 1) and with an attachment system (Stage 2). RESULTS: No implants failed after 3 years. Four late implant failures in three participants occurred in New Zealand (two unilateral implant failures after 5 and 8 years and two bilateral implant failures in the same participant after 6 and 10 years); two unilateral late implant failures occurred in the Netherlands and no late failures in Colombia. Implant survival rate was 92% by 10 years. Resonance frequency measurements were taken at surgery implant stability quotient (ISQ) 62.44 ± 7.46; range 40 - 79), baseline (ISQ 63.22 ± 6.17; range 50 - 74) and after 3 years (ISQ 66.38 ± 6.77; range 55 - 83). In New Zealand and Colombia, measured crestal bone levels were 2.03 ± 0.71 mm and 2.20 ± 0.81 mm, respectively, at baseline and 3 years. For Stage I, principal prosthodontic maintenance issues were loose healing caps among 10 New Zealand participants, four Colombian participants and one Netherlands participant. For Stage 2, matrix activation and overdenture puncture fractures resulted in 41 events (25 participants) in New Zealand over 10 years, whilst over 3 years, there were 14 events in nine Colombian participants and six events in five Netherlands participants. CONCLUSION: This clinical multicentre research complements previous case reports, case series, retrospective and prospective studies on the notion of implant-assisted removable partial dentures for partially edentulous patients. Late implant failures and increased prosthodontic maintenance when an attachment system is used identify the need for further research, including more robust statistical analyses.


Subject(s)
Dental Prosthesis, Implant-Supported/methods , Denture, Partial, Removable , Mandible/surgery , Humans , Prospective Studies , Treatment Outcome
4.
Clin Oral Implants Res ; 27(7): 762-70, 2016 Jul.
Article in English | MEDLINE | ID: mdl-26391110

ABSTRACT

OBJECTIVES: Electrospun cotton wool-like nanocomposite (ECWN) is a novel synthetic bone substitute that incorporates amorphous calcium phosphate nanoparticles into a biodegradable synthetic copolymer poly(lactide-co-glycolide). The objectives of this study were to develop a tooth extraction socket model in sheep for bone graft research and to compare ECWN and bovine-derived xenograft (BX) in this model. MATERIAL AND METHODS: Sixteen cross-bred female sheep were used. Bilateral mandibular premolars were extracted atraumatically. Second and third premolar sockets were filled (Latin-square allocation) with BX, ECWN or left unfilled. Resorbable collagen membranes were placed over BX and selected ECWN grafted sockets. Eight sheep per time period were sacrificed after 8 and 16 weeks. Resin-embedded undemineralised sections were analysed for descriptive histology and histomorphometric analyses. RESULTS: At 8 weeks, there were with no distinct differences in healing among the different sites. At 16 weeks, osseous healing followed a fine trabecular pattern in ECWN sites. Non-grafted sites showed thick trabeculae separated by large areas of fibrovascular connective tissue. In BX grafted sites, xenograft particles were surrounded by newly formed bone or fibrovascular connective tissue. There were no statistically significant differences in bone formation across the four groups. However, ECWN sites had significantly less residual graft material than BX sites at 16 weeks (P = 0.048). CONCLUSIONS: This first description of a tooth extraction socket model in sheep supports the utility of this model for bone graft research. The results of this study suggested that the novel material ECWN did not impede bone ingrowth into sockets and showed evidence of material resorption.


Subject(s)
Alveolar Process/pathology , Bone Substitutes , Calcium Phosphates , Osteogenesis , Wound Healing , Animals , Microscopy , Nanoparticles , Sheep, Domestic , Tooth Extraction , Tooth Socket
5.
Lasers Med Sci ; 29(6): 1977-85, 2014 Nov.
Article in English | MEDLINE | ID: mdl-23907604

ABSTRACT

The aim of this narrative review was to critically evaluate in vitro studies assessing the efficacy of lasers in the bacterial decontamination of titanium implant surfaces. The MEDLINE, Web of Knowledge and Embase electronic databases were used to search for articles relating to the use of lasers in the bacterial decontamination of titanium specimen surfaces using predetermined search statements. Clinical studies, case reports, case series, review articles and animal models were excluded. Study selection was carried out independently and then cross-checked by two authors through abstract viewing. Eighteen articles were selected for full-text analysis. Erbium-doped yttrium-aluminium-garnet lasers had a wide range of powers capable of inducing bacterial decontamination. While carbon dioxide and gallium-aluminium-arsenide diode lasers demonstrated the ability to produce bacterial decontamination, the bacterial sensitivity to each varied depending on the species involved. There is no concensus on the laser type or settings that are optimal for bacterial decontamination of titanium implant surfaces as studies employ various test specimens, contamination methodologies, irradiation settings and protocols, and outcome measures resulting in limited study comparability. More investigations are required to provide guidelines for the use of laser therapy in the decontamination of implant surfaces.


Subject(s)
Decontamination/methods , Dental Implants/microbiology , Laser Therapy/methods , Low-Level Light Therapy/methods , Humans , Inflammation , Lasers , Lasers, Semiconductor , Lasers, Solid-State , Prostheses and Implants , Titanium/radiation effects
6.
N Z Dent J ; 110(1): 6-10, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24683914

ABSTRACT

OBJECTIVES: This study aimed to investigate the understanding, diagnosis and management of peri-implantitis by New Zealand periodontists and oral maxillofacial surgeons (OMFS). DESIGN: Telephone interviews (in combination with a postal and electronic survey) were conducted of all 25 periodontists and 32 OMFS listed as specialists on the New Zealand Dental Register. A seven item multi-choice and short answer questionnaire was used to investigate: their definition of peri-implantitis; the number of annual referrals received in their practice for this condition; their diagnostic, preventive and treatment strategies for peri-implantitis; and their perception of the role of general dental practitioners in its management. RESULTS: The participation rate was 84.6%. Most respondents defined peri-implantitis as a disease of multifactorial aetiology that leads to destruction of the bone supporting an implant. The average number of cases seen annually differed between periodontists (11 cases/year) and OMFS (4 cases/year). The criteria used by the respondents to diagnose peri-implantitis included increased probing depths and radiographic evidence of bone loss. Each type of specialist used mechanical debridement for treatment, but a higher proportion of OMFS performed surgical procedures as treatment. The prevention strategies used smoking cessation advice and ensuring good plaque control. All respondents agreed that peri-implantitis is an important disease that can lead to implant failure, and all acknowledged the role of general dental practitioners in diagnosis, referral for treatment and long-term implant maintenance. CONCLUSION: The definition, diagnostic criteria and management strategies used by New Zealand specialists are generally consistent with those found in the literature. No evidence-based, gold standard treatment protocol for peri-implantitis has been identified in the literature, and New Zealand specialists use a range of treatment modalities.


Subject(s)
Peri-Implantitis/diagnosis , Periodontics , Practice Patterns, Dentists' , Surgery, Oral , Alveolar Bone Loss/diagnostic imaging , Attitude of Health Personnel , Dental Plaque/prevention & control , General Practice, Dental , Humans , Interviews as Topic , New Zealand , Peri-Implantitis/classification , Peri-Implantitis/therapy , Periodontal Debridement/methods , Periodontal Pocket/diagnosis , Practice Patterns, Dentists'/classification , Radiography , Referral and Consultation/statistics & numerical data , Smoking Cessation
7.
Dent J (Basel) ; 12(5)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38786521

ABSTRACT

Complications such as peri-implantitis could ultimately affect the survival of a dental implant. The prevention and treatment of peri-implant diseases require managing bacterial biofilm and controlling environmental risks, including the presence of pro-inflammatory titanium (Ti) particles in the peri-implant niche. Objectives included the evaluation of the size and quantity of Ti particles released from moderately roughened Ti surfaces during common mechanical surface decontamination methods. One hundred and forty moderately roughened Ti discs were divided into seven groups (n = 20 per group); six groups received mechanical decontamination procedures (ultrasonic scaling (US) with a metal tip and poly-ether-ketone (PEEK) under low and medium power settings, air-polishing with erythritol powder, and Ti brush), and the control group underwent air-water spray using a dental triplex. The rinsing solution was collected for Ti mass analysis using inductively coupled plasma mass spectrometry (ICPMS), as well as for Ti particle size and count analysis under scanning electron microscopy (SEM) with energy-dispersive spectroscopy (EDS). US metal tip instrumentation generated 34.00 ± 12.54 µg and 34.44 ± 6.08 µg of Ti under low and medium power settings, respectively. This amount of Ti generation was significantly higher than other instrumentation methods. The mean Ti particle size of the US groups ranged from 0.89 ± 0.27 µm to 1.25 ± 0.24 µm. No statistically significant difference was found in the particle size among US groups and Ti brush group (1.05 ± 0.11 µm), except for US with the PEEK tip, where a significantly smaller mean particle diameter was found at the low power setting (0.89 ± 0.27 µm). Mechanical instrumentation can produce Ti particulates and modify the implant surfaces. US using a metal tip generated the highest amount of Ti with smaller Ti size particles compared to all other commonly used mechanical surface instrumentations. The EDS analysis confirmed Ti in PEEK US tips. It can be suggested that deterioration from the PEEK US tip and Ti brush, as observed under SEM, is an additional source of Ti release during Ti surface decontamination.

8.
Clin Exp Dent Res ; 10(1): e840, 2024 02.
Article in English | MEDLINE | ID: mdl-38345464

ABSTRACT

OBJECTIVES: The coronavirus disease-19 (COVID-19) pandemic has caused disruption in the health behavior in many aspects of life. While hand hygiene was promoted as one of the precautionary measures to mitigate and contain COVID-19, oral health and smoking might have received less attention in the media campaigns. The aim of this study was to examine health behavioral changes in terms of oral home care habits, smoking, and perception of dental care during the COVID-19 pandemic. MATERIAL AND METHODS: An online survey was designed to assess oral home care, smoking habits, and attitude toward dental services of participants aged 18 years and older. The data were collected between September and November 2021. The strength of association between changes in oral home care habits, smoking, and attitude toward invasive/long dental procedures and each variable was measured by χ2 analysis. Estimates of relative risk were also calculated for all variables. Predictors of avoiding dental procedures were estimated by a binary logistic regression. RESULTS: A total of 532 participants, based in the United Arab Emirates, took part in this online survey with a response rate of 88.7%. The age of the participants ranged between 18 and 67 with mean age of 34.9 ± 9.0 years. The majority of the participants have adopted changes in their routine oral home care habits, with 82.1% of them changing the toothbrush more frequently. Participants who changed their oral home care habits were more likely to have received sufficient information on the importance of maintaining oral health. Likewise, the changes in smoking habits were significantly associated with receiving information on the relationship between smoking and the severity of the COVID-19 (p < 0.001). CONCLUSIONS: The findings showed that positive behavior toward oral home care and smoking was noticed during the pandemic particularly when public receives sufficient and up-to-date information.


Subject(s)
COVID-19 , Home Care Services , Humans , Adult , COVID-19/epidemiology , COVID-19/prevention & control , Cross-Sectional Studies , Pandemics , Smoking/adverse effects , Smoking/epidemiology
9.
Clin Exp Dent Res ; 10(4): e932, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38973200

ABSTRACT

OBJECTIVES: There is a growing evidence to suggest augmenting peri-implant keratinized mucosa in the presence of ≤ 2 mm of keratinized mucosa. However, the most appropriate surgical technique and augmentation materials have yet to be defined. The aim of this systematic review and meta-analyses was to evaluate the clinical and patient-reported outcomes of augmenting keratinized mucosa around implants using free gingival graft (FGG) versus xenogeneic collagen matrix (XCM) before commencing prosthetic implant treatment. MATERIAL AND METHODS: Electronic databases were searched to identify observational studies comparing implant sites augmented with FGG to those augmented with XCM. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool. RESULTS: Six studies with 174 participants were included in the present review. Of these, 87 participants had FGG, whereas the remaining participants had XCM. At 6 months, sites augmented with FGG were associated with less changes in the gained width of peri-implant keratinized mucosa compared to those augmented with XCM (mean difference 1.06; 95% confidence interval -0.01 to 2.13; p = 0.05). The difference, however, was marginally significant. The difference between the two groups in changes in thickness of peri-implant keratinized mucosa at 6 months was statistically significantly in favor of FGG. On the other hand, XCM had significantly shorter surgical time, lower postoperative pain score, and higher color match compared to FGG. CONCLUSIONS: Within the limitation of this review, the augmentation of keratinized mucosa using FGG before the placement of the final prosthesis may have short-term positive effects on soft tissue thickness. XCM might be considered in aesthetically demanding implant sites and where patient comfort or shorter surgical time is a priority. The evidence support, however, is of low to moderate certainty; therefore, further studies are needed to support the findings of the present review.


Subject(s)
Collagen , Dental Implants , Gingiva , Humans , Collagen/therapeutic use , Gingiva/transplantation , Gingiva/pathology , Gingiva/surgery , Keratins , Mouth Mucosa/transplantation , Gingivoplasty/methods , Dental Implantation, Endosseous/methods , Heterografts
10.
J Periodontol ; 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38830779

ABSTRACT

BACKGOUND: The aim of this randomized controlled trial was to assess clinical and patient-reported outcomes of subgingival instrumentation (SI) with adjunctive use of erythritol airflowing (EAF) compared to SI alone in the treatment of periodontitis. METHODS: Twenty-six participants with Stage III/IV periodontitis requiring nonsurgical periodontal treatment were randomly allocated into two treatment groups: SI with EAF or SI alone. Clinical parameters of percentage of probing pocket depths (PPDs) of ≥5 mm, full mouth bleeding and plaque scores (FMBS and FMPS), and PPD values were recorded at baseline, and at 3 and 6 months posttreatment. A visual analogue scale was used to evaluate postoperative participants' perception of pain, swelling, bleeding, bruising, and root sensitivity. The impact of periodontal treatment on quality of life was assessed using the General Oral Health Assessment Index (GOHAI) at six months. RESULTS: A total of 26 participants with Stage III/IV periodontitis completed the 6-month follow-up. SI with or without EAF resulted in a statistically significant reductions in the FMBS, FMPS, PPDs, and percentage of PPDs of ≥5 mm at the 3- and 6-month follow-up visits. There was no statistically significant difference between the two treatment groups for any time interval. Participants receiving SI/EAF exhibited a higher reduction in FMBS compared to those in SI alone group at 3 (SI/EAF: 19.4 ± 11.9, SI alone: 30.1 ± 20.5; P = 0.12) and 6 months (SI/EAF: 14.3 ± 9.6, SI alone: 24.5 ± 18.2; P = 0.09). A lower percentage of sites with deep PPDs (≥5 mm) was also noted amongst participants in the SI/EAF group compared to SI alone at 3 months (SI/EAF: 14.3 ± 14.1, SI alone: 19.2 ± 20.3; P = 0.48) and 6 months (SI/EAF: 8.3 ± 10.0, SI alone: 15.4 ± 17.4; P = 0.22). Patient-reported outcomes showed no significant differences between the two treatment groups, except in the psychosocial domain of the GOHAI at 6 months favoring the SI/EAF group (P = 0.03). CONCLUSIONS: Within the limitations of the study, the adjunctive use of EAF in addition to SI in the treatment of Stage III/IV periodontitis did not result in a significant improvement in clinical parameters. Limited improvement in the QoL with EAF could be achieved.

11.
Int J Oral Maxillofac Implants ; 0(0): 1-9, 2024 Oct 09.
Article in English | MEDLINE | ID: mdl-38728047

ABSTRACT

PURPOSE: To compare the prosthetic outcomes of screw-retained monolithic zirconia (Zr) single crowns supported by either narrow-diameter (3.3 mm) or standard-diameter (4.1 mm) tissue-level titanium-zirconia (TiZr) implants in posterior sites. MATERIALS AND METHODS: A total of 18 participants, each with a missing molar or premolar tooth requiring an implantsupported single crown, were randomly assigned to either the test or control group. All participants received screwretained monolithic Zr single crowns supported by single tissue-level TiZr implants. Test group participants received narrow-diameter implants (3.3 mm), whereas control group participants received standard-diameter implants (4.1 mm). A modified version of the United States Public Health Service (USPHS) criteria was used to assess the prosthetic outcome across 12 parameters after 1 year of function. Data were analyzed descriptively, and statistical analysis was performed using a statistical software (SPSS, Version 28.0; IBM) with the level of significance set at P < .05. RESULTS: Of the 18 single crowns delivered, 16 were available for review at the 1-year follow-up, including 7 in the test group and 9 in the control group. Patient characteristics and crown site distribution were similar, with no significant differences observed between the two groups (chi-square test; P < .05). There were no crown failures, meaning a crown survival rate of 100% was achieved after 1 year. The prosthetic outcome based on USPHS criteria was comparable between the two groups with no significant differences observed (chi-square test; P < .05). There were 19 prosthetic events in total (10 in the test group and 9 in the control group), with no significant differences between the groups (chi-square test; P < .05). Loss of proximal contact was the dominant event, with a total of eight events (three in the test group and five in the control group). Patient satisfaction after 1 year was high in both treatment groups, with no significant differences detected. CONCLUSIONS: Screw-retained monolithic Zr single crowns supported by either narrow- or standard-diameter tissue-level TiZr implants in posterior sites have comparable prosthetic outcomes after 1 year. Long-term results from well-designed trials are still needed to validate the findings of the present study.

12.
Clin Oral Implants Res ; 24(1): 20-7, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22111809

ABSTRACT

OBJECTIVE: To compare the levels of patient satisfaction with either conventional mandibular bilateral distal extension partial dentures or those assisted by bilateral distal implants. MATERIALS AND METHODS: Forty-eight participants who were dissatisfied with their existing conventional mandibular distal extension dentures opposing complete maxillary dentures were selected for a multicentre prospective study in New Zealand, Colombia and the Netherlands. A control group of 12 participants in New Zealand received conventional mandibular partial dentures. Three test groups involving 36 participants in New Zealand (12), Colombia (12) and the Netherlands (12) received bilateral distal implants in the second molar regions. After conventional loading, the test group participants initially had healing caps placed on the distal implants providing support only, followed after approximately 6 months by ball abutments (retentive anchors) for support and retention. Patient outcomes were determined with questionnaires completed at specific stages of the study for up to 3 years. RESULTS: Visual analogue scale, Likert and oral health impact questionnaires before and after treatment indicated improved results. There were significantly improved parameters of overall satisfaction, stability, chewing and appearance after 3 years (P < 0.05). There were also improvements on stability, chewing and overall satisfaction. Speech also improved, but not significantly. Ball abutments (retentive anchors) on the distal implants, as opposed to healing caps improved patient satisfaction for stability, chewing and overall satisfaction. Changing to ball abutments (retentive anchors) revealed significant improvement by participant response when evaluating parameters of stability, chewing and overall satisfaction (P < 0.05). CONCLUSION: Mandibular implant-assisted removable partial dentures are a preferable treatment option for patients with complaints about their conventional distal extension partial dentures.


Subject(s)
Dental Prosthesis, Implant-Supported , Denture, Partial, Removable , Jaw, Edentulous, Partially/rehabilitation , Mandible/surgery , Adult , Aged , Aged, 80 and over , Colombia , Dental Abutments , Dental Implants , Denture Retention , Female , Humans , Male , Middle Aged , Netherlands , New Zealand , Patient Satisfaction , Prospective Studies , Surveys and Questionnaires
13.
Saudi Dent J ; 35(4): 294-304, 2023 May.
Article in English | MEDLINE | ID: mdl-37251724

ABSTRACT

Introduction: Crown lengthening is one of the most common periodontal surgical procedures carried out to increase the amount of supragingival tooth structure. There is a lot of literature on crown lengthening surgeries, but very few systematic reviews comparing treated and adjacent sites over a six-month period. The purpose of this systematic review and meta-analysis was to evaluate the outcomes of crown lengthening surgery in terms of changes in periodontal clinical parameters and periodontal tissue stability between treated and adjacent sites. Methods: Electronic databases were searched up to 28 February 2022 with no restriction on publication status. A manual search of journals was also performed. Predefined inclusion and exclusion criteria were used to select the relevant articles that assessed dimensional changes in periodontal tissues after crown lengthening surgery. The risk of bias was assessed using the JBI critical appraisal checklist. Data meta-analysis was performed using a statistical software program. Results: A total of 78 studies were identified, of which, four clinical controlled trials containing 182 crown lengthening surgical procedures across 111 participants were included. Meta-analysis showed no statistically significant changes after three or six months in terms of supracrestal tissue attachment levels, bone level and probing pocket depth between treated and adjacent sites. However, clinical attachment level changes were statistically significant, favouring adjacent teeth at six months. Conclusions: Within the limitation of this systematic review, crown lengthening surgery results in stable periodontal tissues over time according to the acceptable periodontal healing parameters. Further evidence is still required to substantiate these findings.

14.
Clin Implant Dent Relat Res ; 25(5): 840-852, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37183357

ABSTRACT

BACKGROUND: Implant restorative emergence angle and profile may have a negative impact on peri-implant marginal bone level and may increase the risk of developing peri-implantitis. However, the role of these prosthetic features on peri-implant health is still unclear. The aim of this systematic review and meta-analyses was to evaluate the long-term outcomes of implant restorations with an emergence angle of >30° in comparison to those with ≤30° in terms of changes in peri-implant marginal bone level, periodontal parameters, and prevalence rate of peri-implantitis. METHODS: Electronic databases were searched to identify observational studies that compared implant restorations with an emergence angle of >30° to those with ≤30°. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool. RESULTS: Four studies with 912 dental implants in 397 participants were included in the present review. Of these, 455 implants had restorations with an emergence angle of >30°, while the remaining implants had restorative emergence angle of ≤30°. The follow-up time varied between 3.8 and 10.9 years. Implant restorations with an emergence angle of ≤30° were associated with less changes in peri-implant marginal bone level compared to those with emergence angle of >30°. The difference, however, was not statistically significant (mean difference 0.80; 95% confidence interval (CI) -0.13 to 1.72; p = 0.09). In platform-matched implants, the difference between the two groups was statistically significant in favor of implant restorations with emergence angle of ≤30°. In terms of emergence profile, implant restorations with convex profile had significantly higher rate of peri-implantitis (57.8%) compared to implant restorations with concave or straight profile (21.3%) (risk ratio 2.32; 95% CI 1.12-4.82; p = 0.02). CONCLUSIONS: Within the limitation of this review, implant restorations with an emergence angles of >30° or ≤30° seem to have no significant influence on peri-implant marginal bone level. Platform-matched implants with an emergence angle of ≤30° may have positive effects on the peri-implant marginal bone level changes, but the evidence support is of low to moderate certainty.


Subject(s)
Alveolar Bone Loss , Dental Implants , Peri-Implantitis , Humans , Dental Implants/adverse effects , Peri-Implantitis/etiology , Alveolar Bone Loss/etiology , Databases, Factual
15.
Dent J (Basel) ; 11(3)2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36975555

ABSTRACT

Alveolar ridge preservation (ARP) reduces dimensional changes following tooth extraction. We evaluated the changes in alveolar ridge dimensions after ARP using bone substitutes and collagen membranes. Objectives included the tomographic evaluation of sites prior to extraction and six months after ARP and the assessment of the extent ARP preserved the ridge and reduced the need for additional augmentation at the time of implant placement. A total of 12 participants who underwent ARP in the Postgraduate Periodontics Clinic (Faculty of Dentistry) were included. Cone beam computed tomography images were used to retrospectively assess 17 sites prior to and six months after dental extraction. Alveolar ridge changes were recorded and analysed using reproducible reference points. The alveolar ridge height was measured at buccal and palatal/lingual aspects, whilst width was measured at crestal level, 2 mm, 4 mm and 6 mm below the crest. Statistically significant changes were found in alveolar ridge width at all four heights, with mean reduction differences ranging from 1.16 mm to 2.84 mm. Likewise, significant changes in the palatal/lingual alveolar ridge height (1.28 mm) were observed. However, changes of 0.79 mm in buccal alveolar ridge height were not significant (p = 0.077). Although ARP reduced dimensional changes following a tooth extraction, some degree of alveolar ridge collapse could not be avoided. The amount of resorption on the buccal aspect of the ridge was less compared to the palatal/lingual after ARP. This indicated that the use of bone substitutes and collagen membranes was effective in reducing changes in the buccal alveolar ridge height.

16.
Clin Implant Dent Relat Res ; 24(2): 196-210, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35156296

ABSTRACT

BACKGROUND: Nonsurgical treatment of peri-implantitis may help in reducing microbial load and inflammatory parameters. The potential clinical benefits of using different treatment approaches, in the initial nonsurgical treatment phase, particularly the airflow, are still not clear. The aim of this systematic review and meta-analyses was to evaluate the outcomes of nonsurgical treatment of peri-implantitis using airflow method in terms of changes in periodontal parameters, peri-implant marginal bone level, postoperative pain/discomfort, and patient satisfaction. METHODS: Electronic databases were searched to identify randomized controlled trials (RCTs) that compared airflow with mechanical debridement using ultrasonic/curettes. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool. Data were analyzed using a statistical software program. RESULTS: A total of 316 studies were identified, of which, five RCTs with 288 dental implants in 174 participants were included. Overall meta-analysis showed more reduction in probing pocket depths at 1-3 months (mean difference [MD] -0.23; 95% confidence interval [CI] -0.50-0.05; p = 0.10) and 6 months (MD -0.04; 95% CI -0.34 to 0.27; p = 0.80) in favor of airflow, but the difference was not statistically significant. The use of airflow was associated with significant reduction in bleeding on probing and increase in peri-implant mucosal recession. The differences in plaque score, peri-implant marginal bone level changes, and patient reported outcomes between airflow and mechanical debridement were not statistically significant. CONCLUSIONS: The short-term clinical and radiographic outcomes following nonsurgical treatment of peri-implantitis using airflow or mechanical debridement were comparable. The airflow has short-term positive effects on reducing bleeding on probing. Further evidence from RCTs are still required to substantiate the current findings.


Subject(s)
Dental Implants , Peri-Implantitis , Dental Implants/adverse effects , Humans , Peri-Implantitis/surgery
17.
Int J Dent ; 2022: 1545748, 2022.
Article in English | MEDLINE | ID: mdl-35990253

ABSTRACT

Methods: A retrospective analysis of patients aged ≥18 years and having dental implants placed at Dubai Health Authority in 2010. Relevant information related to systemic-, patient-, implant-, site-, surgical- and prosthesis-related factors were collected. The strength of association between the prevalence of peri-implant mucositis and peri-implantitis and each variable was measured by chi-square analysis. A binary logistic regression analysis was performed to identify possible risk factors. Results: A total of 162 patients with 301 implant-supported restorations were included in the study. The age of the patients ranged between 19 and 72 with a mean age of 46.4 ± 11.7 years. The prevalence of peri-implant mucositis at the patient and implant levels were 44.4% and 38.2%, respectively. For peri-implantitis, the prevalence at the patient level was 5.6%, while the prevalence at the implant level was 4.0%. The binary logistic regression identified three risk factors (smoking habits, histories of treated periodontitis and lack of peri-implant maintenance) for peri-implantitis. Conclusion: Within the limitations of this study, smoking habits, history of treated periodontitis and lack of peri-implant maintenance were significant risk factors for peri-implantitis. Early detection of these factors would ensure appropriate planning and care of patients at high risk of developing peri-implant diseases.

18.
Clin Implant Dent Relat Res ; 23(3): 341-360, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33764648

ABSTRACT

BACKGROUND: The influence of using different insertion torque values on clinical and radiographic outcomes of implant therapy is unclear in the current literature. The aim of this systematic review and meta-analysis was to evaluate the implant outcomes and complications rates using high insertion torque values compared with those using regular insertion torque value levels. METHODS: Randomized controlled trials (RCTs), nonrandomized controlled clinical trials (NRCCTs), prospective and retrospective cohorts were searched for in electronic databases and complemented by hand searching relevant dental journals. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool for randomized and nonrandomized studies. Data were analyzed using a statistical software. RESULTS: A total of 718 studies were identified, of which, nine studies were included with 1229 dental implants in 684 participants. The meta-analysis of RCTs showed that the overall implant failure rate was not notably in favor of any insertion torque value and the difference between the two groups was not statistically significant (risk ratio 0.85; 95% confidence interval 0.07-10.52; P = 0.90). None of the RCTs was registered. The secondary analyses of non-RCTs did not either show any statistically significant difference. Overall meta-analysis did not show any significant differences in peri-implant marginal bone loss or biological/technical complications between high (≥50 Ncm) and regular insertion torque (<50 Ncm). CONCLUSIONS: There is insufficient evidence to support the use of high or regular insertion torque even with immediate implant restoration/loading. The short-term implant failure rates, changes in marginal bone level and complication rates were comparable when high or regular insertion torques were used for implant placement. The wide confidence interval indicated that results cannot be interpreted with clinically meaningful benefit for using either high or regular insertion torque.


Subject(s)
Dental Implants , Immediate Dental Implant Loading , Dental Implantation, Endosseous/adverse effects , Dental Implants/adverse effects , Dental Restoration Failure , Humans , Torque
19.
Saudi Dent J ; 32(6): 283-292, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32874068

ABSTRACT

OBJECTIVE: To investigate the presence of titanium particles in peri-implant tissues in cases diagnosed with peri-implantitis, and to identify immunological reactions that these particles may elicit. METHODS: Ten peri-implant tissue biopsies of patients diagnosed clinically and radiographically with peri-implantitis were obtained from the archives of Oral Pathology Centre, University of Otago. The inclusion criteria involves: bleeding on probing, ≥6 mm probing depth and ≥3 mm radiographic bone loss around the dental implant. Peri-implant tissue samples were evaluated using scanning electron microscopy-energy dispersive x-ray spectroscopy (SEM-EDS) to identify of sites with/without titanium particles. Antibodies against human transforming growth factor beta 1 (TGF-ß1), receptor activator of nuclear factor kappa-B ligand (RANKL), interleukin 33 (IL-33) and cluster of differentiation 68 (CD68) were used to stain the specimens. ImageJ software was used to standardise the sampling area, compare and characterise the inflammatory infiltrate in tissues with/without titanium particles. Inflammatory cytokines positivity was assessed using the immunoreactive scores (IRSs). RESULTS: Light microscopy and SEM-EDS analysis identified titanium wear particles in 90% of the tissue samples, associated with a mixed chronic inflammatory infiltrate. Quantification analysis of RANKL revealed significantly higher IRS and intensity scores (p < 0.05) in areas containing titanium. High intensity, proportion and IRSs of TGF-ß1 and IL-33 were observed in areas with titanium. CD68 had higher IRSs in the absence of titanium particles. CONCLUSIONS: Significant overexpression of the cytokine RANKL was observed, with a trend for over-expression of IL-33 and TGF-B1 in areas with titanium. Further studies with large sample size and appropriate control group for quantification analysis is needed to confirm the role of titanium particles in initiating bone loss.

20.
Clin Implant Dent Relat Res ; 21(2): 344-351, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30767417

ABSTRACT

BACKGROUND: Single implant crowns have become the preferred rehabilitation treatment option for replacing a missing tooth. PURPOSE: This study evaluates 5-year clinical success of using tilted implants placed immediately after extraction followed by rehabilitation with all-ceramic crowns. MATERIALS AND METHODS: Twenty-seven participants requiring 28 single implant crowns in the aesthetic zone of maxilla were recruited to participate in a single-arm clinical trial. All participants were rehabilitated according to immediate implant placement using CP grade 4 titanium implants with roughened surfaces and a 12°-angled platform. Provisional implant crowns were connected within 4 hours of implant placement and loaded according to progressive loading protocol. At 8 weeks (baseline), definitive screw-retained crowns fabricated using densely sintered zirconia abutments with the veneering porcelain were delivered. Participants were followed up to 5 years and 16 participants with 17 single implant crowns attended Year 5 recall. Data collection included changes in marginal bone levels (MBLs), mid-buccal mucosal levels (MBMLs), implant stability quotient (ISQ) values, and any prosthodontic maintenance issues. RESULTS: The mean changes in MBLs at each recall was bone fill of 0.5 ± 1.18 mm (surgery-baseline), increase of 0.1 ± 0.57 mm (baseline-Year 1), and marginal bone loss of 0.1 ± 0.25 mm (Years 1-5). A minimal change occurred with the MBMLs during the observation period. The mean ISQ value at each time point increased from 65.1 (implant placement), to 67.4 (baseline) and 69.9 (Years 1 and 5). Prosthodontic maintenance issues occurred only during the first year which included fracture of veneering ceramic and zirconia abutment as well as aesthetic concerns. CONCLUSIONS: Within the limitations of this study, the data collected would suggest that replacing a single missing tooth using titanium oral implants with 12° platform tilt and zirconia abutments can be a successful rehabilitation option in the esthetically demanding zone of anterior maxilla.


Subject(s)
Alveolar Bone Loss , Dental Implants, Single-Tooth , Immediate Dental Implant Loading , Maxilla , Crowns , Dental Prosthesis, Implant-Supported , Esthetics, Dental , Follow-Up Studies , Humans , Prospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL