Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
1.
J Med Biol Eng ; 38(5): 835-844, 2018.
Article in English | MEDLINE | ID: mdl-30220902

ABSTRACT

The aim of this study was to establish a web-based platform for exchanging medical device management and maintenance experiences to enhance the professional competency of clinical engineers (CEs), which ensures the quality of medical devices and increases patients' satisfaction with medical services. Medical devices play an essential role in diagnosis and disease management. CEs are responsible for providing functional medical devices that contribute worthwhile functions to a medical service to improve patients' health and safety. The purpose of the platform is to facilitate collection and sharing of medical device incidents experiences to improve CEs' capability. To provide useful and practical information for CEs, an event review committee, composed of experts with more than 20 years of clinical engineering experience who were recruited as reviewers, was established under the platform. Cases submitted to the platform were required to have comprehensive descriptions of the device and events. Each case was evaluated by at least two reviewers based on five evaluation indices: (1) severity, (2) breadth, (3) frequency, (4) insidiousness, and (5) correctness. After being reviewed, each final report was published on the platform to be shared with the event submitters and other members. The results show that 116 staffs from 32 different hospitals, registered to join this platform. From January 2015 to December 2016, 70 events were submitted with 56 reports. This study also assessed the platform's benefits for CEs. A total of 93 respondents completed a questionnaire survey: 93% of the CEs agreed that the information from the platform helped them do their job. The web-based platform has high value as an experience-sharing interface for medical devices. The CEs obtained extremely useful information from the platform for medical device management and their daily duties. This study provided an online training model with systematic methods to improve the quality and effectiveness of medical device management.

2.
ScientificWorldJournal ; 2014: 106941, 2014.
Article in English | MEDLINE | ID: mdl-25530989

ABSTRACT

Adequately shaped femoral plate is critical for the fixation of fracture in the pertrochanteric regions. Lateral aspect of greater trochanter is an important region where the proximal femoral plate anchored. However, little is known regarding the morphology of greater trochanter. The objective of this study was to measure main dimensions of greater trochanter and other regions in the proximal end of the femur to provide an anatomical basis for the design of the proximal femoral plate. Anthropometric data on the proximal femur were performed utilizing three-dimensional computational modeling. Computed tomography images of healthy femurs in 53 women and 47 men were contributed to three-dimensional femur modeling. All data were compared between male and female femora. The results showed that mean values for male group were found to be greater in most of measured femoral dimensions. Oppositely, females demonstrated higher neck-shaft angle on anteroposterior view and femoral anteversion angle. The anthropometric data can be used for the anatomical shape design of femoral plates for osteosynthesis of fractures in the trochanteric regions. A distinct plate design may be necessary to accommodate differences between the genders.


Subject(s)
Asian People , Bone Plates , Femur/anatomy & histology , Prosthesis Design , Adult , China , Female , Femur/diagnostic imaging , Humans , Male , Tomography, X-Ray Computed
3.
Diagnostics (Basel) ; 12(5)2022 Apr 24.
Article in English | MEDLINE | ID: mdl-35626222

ABSTRACT

The management of peptic ulcer bleeding is clinically challenging. For decades, the Forrest classification has been used for risk stratification for nonvariceal ulcer bleeding. The perception and interpretation of the Forrest classification vary among different endoscopists. The relationship between the bleeder and ulcer images and the different stages of the Forrest classification has not been studied yet. Endoscopic still images of 276 patients with peptic ulcer bleeding for the past 3 years were retrieved and reviewed. The intra-rater agreement and inter-rater agreement were compared. The obtained endoscopic images were manually drawn to delineate the extent of the ulcer and bleeding area. The areas of the region of interest were compared between the different stages of the Forrest classification. A total of 276 images were first classified by two experienced tutor endoscopists. The images were reviewed by six other endoscopists. A good intra-rater correlation was observed (0.92-0.98). A good inter-rater correlation was observed among the different levels of experience (0.639-0.859). The correlation was higher among tutor and junior endoscopists than among experienced endoscopists. Low-risk Forrest IIC and III lesions show distinct patterns compared to high-risk Forrest I, IIA, or IIB lesions. We found good agreement of the Forrest classification among different endoscopists in a single institution. This is the first study to quantitively analyze the obtained and explain the distinct patterns of bleeding ulcers from endoscopy images.

4.
J Clin Med ; 10(16)2021 Aug 11.
Article in English | MEDLINE | ID: mdl-34441823

ABSTRACT

With the decreasing incidence of peptic ulcer bleeding (PUB) over the past two decades, the clinician experience of managing patients with PUB has also declined, especially for young endoscopists. A patient with PUB management requires collaborative care involving the emergency department, gastroenterologist, radiologist, and surgeon, from initial assessment to hospital discharge. The application of artificial intelligence (AI) methods has remarkably improved people's lives. In particular, AI systems have shown great potential in many areas of gastroenterology to increase human performance. Colonoscopy polyp detection or diagnosis by an AI system was recently introduced for commercial use to improve endoscopist performance. Although PUB is a longstanding health problem, these newly introduced AI technologies may soon impact endoscopists' clinical practice by improving the quality of care for these patients. To update the current status of AI application in PUB, we reviewed recent relevant literature and provided future perspectives that are required to integrate such AI tools into real-world practice.

5.
J Orthop Surg (Hong Kong) ; 26(1): 2309499018760130, 2018.
Article in English | MEDLINE | ID: mdl-29486668

ABSTRACT

Headless compression screws (HCSs) are commonly used to fixate small bones and articular fractures. Understanding the biomechanical efficacy of different HCS designs can help surgeons make proper interfragmentary compression when a specific implant is chosen. HCSs with three different central shaft designs (unthreaded, fully threaded, and partially threaded) were studied: the Herbert-Whipple, Mini-Acutrak 2, and headless reduction (HLR). Polyurethane foam blocks were machined with a simulated fracture gap of 0.5 mm and set onto a custom-made jig to simultaneously measure compression force and driving torque during screw insertion. The maximal achievable compression forces and driving torques recorded were 47.4 ± 0.9 N and 145.11 ± 1.65 N mm for the HLR, 50.98 ± 1.29 N and 152.62 ± 2.83 N mm for the Mini-Acutrak 2, and 19.33 ± 1.0 N and 33.4 ± 2.2 N mm for the Herbert-Whipple. Overall, the compression force of the Mini-Acutrak 2 and HLR increased with the torque. Unlike the other screws, the Herbert-Whipple's driving torque increased while the compression force decreased after peak compression force was achieved. The partially threaded shaft design (HLR) demonstrated equivalent biomechanical advantage with the Mini-Acutrak 2 in interfragmentary compression. The HCSs with cone-shaped proximal ends (HLR and Mini-Acutrak 2) maintained their compression force during over-fastening, whereas the unthreaded central shaft of the Herbert-Whipple screw caused it to lose compression force.


Subject(s)
Bone Screws , Computer Simulation , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Intra-Articular Fractures/surgery , Biomechanical Phenomena , Humans , Polyurethanes , Pressure
6.
Med Eng Phys ; 56: 48-53, 2018 06.
Article in English | MEDLINE | ID: mdl-29685856

ABSTRACT

The far cortical locking (FCL) system, a novel bridge-plating technique, aims to deliver controlled and symmetric interfragmentary motion for a potential uniform callus distribution. However, clinical data for the practical use of this system are limited. The current study investigated the biomechanical effect of a locking plate/far cortical locking construct on a simulated comminuted diaphyseal fracture of the synthetic bones at different distance between the plate and the bone. Biomechanical in vitro experiments were performed using composite sawbones as bone models. A 10-mm osteotomy gap was created and bridged with FCL constructs to determine the construct stiffness, strength, and interfragmentary movement under axial compression, which comprised one of three methods: locking plates applied flush to bone, at 2 mm, or at 4 mm from the bone. The plate applied flush to the bone exhibited higher stiffness than those at 2 mm and 4 mm plate elevation. A homogeneous interfragmentary motion at the near and far cortices was observed for the plate at 2 mm, whereas a relatively large movement was observed at the far cortex for the plate applied at 4 mm. A plate-to-bone distance of 2 mm had the advantages of reducing axial stiffness and providing nearly parallel interfragmentary motion. The plate flush to the bone prohibits the dynamic function of the far cortical locking mechanism, and the 4-mm offset was too unstable for fracture healing.


Subject(s)
Bone Plates , Fracture Fixation, Internal/instrumentation , Bone Screws , Diaphyses/injuries , Diaphyses/surgery , Humans
7.
Biomed Tech (Berl) ; 62(3): 257-261, 2017 May 24.
Article in English | MEDLINE | ID: mdl-27341556

ABSTRACT

Headless compression screws (HCSs) are commonly utilized devices for small bone fracture fixation. The Mini-Acutrak 2 and headless reduction (HLR) screws are the newer version types, in which both have fully threaded and variable pitch design. Specifically, the HLR is characterized by two thread runouts to facilitate implantation. With the thread runouts, the holding strength of the screw may be compromised. To the best of our knowledge, no study has examined the pullout force of the global sizes of a HCS. We sought to determine the pullout strength of the HLR and compare the strength of this screw with that of the Mini-Acutrak 2. Synthetic bone blocks with simulated transverse fractures were used to conduct the tests. Four commonly used sizes of the HLR were examined, and one Mini-Acutrak 2 was employed for comparison. Five screws of each size were tested. The pullout force of all screws that were tested in this study ranged from 45.23 to 233.22 N. The results revealed that the pullout force increased as the screw diameter increased. Interestingly, we found that one small screw outperformed the Mini-Acutrak 2, which has a larger diameter. This study provided extensive knowledge regarding the pullout strength of fully threaded HCSs of different sizes. An unexpected finding is that a small screw has higher holding power than a large one because of its increased number of threads. Therefore, we suggest that the thread number should be a critical consideration for the design of size distribution of HCSs.


Subject(s)
Bone Screws/standards , Fracture Fixation, Internal/instrumentation , Pressure , Tensile Strength/physiology , Equipment Design , Humans
8.
Biomed Res Int ; 2017: 8149109, 2017.
Article in English | MEDLINE | ID: mdl-28497066

ABSTRACT

The clavicle has a complex geometry that makes plate fixation technically difficult. The current study aims to measure the anatomical parameters of Chinese clavicles as reference for plate design. One hundred clavicles were analyzed. The clavicle bone model was reconstructed by using computed tomography images. The length, diameters, and curvatures of the clavicle were then measured. The female clavicle was shorter, more slender, and less curved in lateral part than the male clavicle. There was a positive relationship between height and clavicle parameters except lateral curve and depth. The measurements of Chinese clavicles were generally smaller than Caucasians. The clavicle curves were correlated with the bone length; thus consideration of the curve variations may be necessary as designing size distribution of clavicle plate.


Subject(s)
Clavicle/anatomy & histology , Clavicle/diagnostic imaging , Sex Characteristics , Tomography, X-Ray Computed , Adult , Asian People , China , Female , Humans , Male , Middle Aged
9.
Comput Math Methods Med ; 2017: 2750701, 2017.
Article in English | MEDLINE | ID: mdl-28634497

ABSTRACT

Inspiratory flow limitation (IFL) is a critical symptom of sleep breathing disorders. A characteristic flattened flow-time curve indicates the presence of highest resistance flow limitation. This study involved investigating a real-time algorithm for detecting IFL during sleep. Three categories of inspiratory flow shape were collected from previous studies for use as a development set. Of these, 16 cases were labeled as non-IFL and 78 as IFL which were further categorized into minor level (20 cases) and severe level (58 cases) of obstruction. In this study, algorithms using polynomial functions were proposed for extracting the features of IFL. Methods using first- to third-order polynomial approximations were applied to calculate the fitting curve to obtain the mean absolute error. The proposed algorithm is described by the weighted third-order (w.3rd-order) polynomial function. For validation, a total of 1,093 inspiratory breaths were acquired as a test set. The accuracy levels of the classifications produced by the presented feature detection methods were analyzed, and the performance levels were compared using a misclassification cobweb. According to the results, the algorithm using the w.3rd-order polynomial approximation achieved an accuracy of 94.14% for IFL classification. We concluded that this algorithm achieved effective automatic IFL detection during sleep.


Subject(s)
Algorithms , Diagnostic Techniques, Respiratory System , Sleep Apnea Syndromes/diagnosis , Humans , Respiration
10.
Med Biol Eng Comput ; 55(8): 1189-1198, 2017 Aug.
Article in English | MEDLINE | ID: mdl-27744563

ABSTRACT

Exercise periodic breathing (EPB) is associated with exercise intolerance and poor prognosis in patients with heart failure (HF). However, EPB detection during cardiopulmonary exercise test (CPET) is difficult. The present study investigated the use of a wireless monitoring device to record the EPB during CPET and proposed quantization parameter estimates for the EPB. A total of 445 patients with HF were enrolled and underwent exercise tests. The ventilation data from the wearable device were compared with the data obtained during the CPET and were analyzed based on professional opinion and on 2 automated programs (decision tree [DT] and oscillatory pattern methods). The measurement accuracy was greater with the DT method (89 %) than with the oscillatory pattern method (75 %). The cutoffs for EPB recognition using the DT method were (1) an intercept of the regression line passing through the minute ventilation rate vs. the time curve during the recovery phase ≥64.63, and (2) an oscillatory phase duration to total exercise time ratio ≥0.5828. The wearable device was suitable for the assessment of EPB in patients with HF, and our new automated analysis system using the DT method effectively identified the EPB pattern.


Subject(s)
Breath Tests/instrumentation , Cheyne-Stokes Respiration/diagnosis , Cheyne-Stokes Respiration/physiopathology , Exercise Test/instrumentation , Heart Failure/diagnosis , Heart Failure/physiopathology , Thermography/instrumentation , Cheyne-Stokes Respiration/etiology , Diagnosis, Computer-Assisted/methods , Equipment Design , Equipment Failure Analysis , Female , Heart Failure/complications , Humans , Male , Middle Aged , Oscillometry/instrumentation , Reproducibility of Results , Respiratory Mechanics , Rheology/instrumentation , Sensitivity and Specificity
11.
Biomed Tech (Berl) ; 61(3): 331-6, 2016 Jun 01.
Article in English | MEDLINE | ID: mdl-26351785

ABSTRACT

Medial migration or cutout of the neck helical blade has commonly occurred in the treatment of trochanteric fracture of the femur. The position of the helical blade within the femoral head is one of the influencing factors that cause the blade to perforate the intact joint surface; however, the ideal placement of the helical blade is not currently known. A finite element model of a femur/nail construct was utilized to analyze five possible blade positions in the femoral head. Normal strain at the fracture surface, the minimum principal strain in the cancellous bone, and the von Mises stress in the implant itself were calculated and compared between different blade positions. The results showed that a large area of normal compressive strain at the fracture surface was observed in the inferior and posterior blade positions. The volume of cancellous bone strained to yielding in the femoral head and neck was lower for the inferior and posterior positions, whereas it was the highest for the superior position. The inferior and posterior positions had lower von Mises stress in the implant itself. The inferior and posterior positions may be the ideal position for the intramedullary nail with a helical neck blade.


Subject(s)
Cancellous Bone/physiology , Femur Head/physiology , Femur Neck/physiology , Finite Element Analysis/standards , Fracture Fixation, Internal , Humans , Prosthesis Design
12.
Comput Methods Biomech Biomed Engin ; 19(13): 1363-70, 2016 Oct.
Article in English | MEDLINE | ID: mdl-26813403

ABSTRACT

Initial stability is essential for open reduction internal fixation of intraarticular calcaneal fractures. Geometrical feature of a calcaneal plate is influential to its endurance under physiological load. It is unclear if conventional and pre-contoured anatomical calcaneal plates may exhibit differently in biomechanical perspective. A Sanders' Type II-B intraarticular calcaneal fracture model was reconstructed to evaluate the effectiveness of calcaneal plates using finite element methods. Incremental vertical joint loads up to 450 N were exerted on the subtalar joint to evaluate the stability and safety of the calcaneal plates and bony structure. Results revealed that the anatomical calcaneal plate model had greater average structural stiffness (585.7 N/mm) and lower von Mises stress on the plate (774.5 MPa) compared to those observed in the conventional calcaneal plate model (stiffness: 430.9 N/mm; stress on plate: 867.1 MPa). Although both maximal compressive and maximal tensile stress and strain were lower in the anatomical calcaneal plate group, greater loads on fixation screws were found (average 172.7 MPa compared to 82.18 MPa in the conventional calcaneal plate). It was noted that high magnitude stress concentrations would occur where the bone plate bridges the fracture line on the lateral side of the calcaneus bone. Sufficient fixation strength at the posterolateral calcaneus bone is important for maintaining subtalar joint load after reduction and fixation of a Sanders' Type II-B calcaneal fracture. In addition, geometrical design of a calcaneal plate should worth considering for the mechanical safety in practical usage.


Subject(s)
Bone Plates , Calcaneus/physiopathology , Finite Element Analysis , Fractures, Bone/pathology , Fractures, Bone/physiopathology , Joints/pathology , Joints/physiopathology , Aged , Biomechanical Phenomena , Bone Screws , Compressive Strength , Fractures, Bone/surgery , Humans , Male , Models, Anatomic , Stress, Mechanical , Tensile Strength
13.
Injury ; 47(6): 1191-5, 2016 Jun.
Article in English | MEDLINE | ID: mdl-26975793

ABSTRACT

BACKGROUND: Locking plate fixation for proximal humeral fractures is a commonly used device. Recently, plate breakages were continuously reported that the implants all have a mixture of holes allowing placement of both locking and non-locking screws (so-called combi plates). In commercialized proximal humeral plates, there still are two screw hole styles included "locking and dynamic holes separated" and "locking hole only" configurations. It is important to understand the biomechanical effect of different screw hole style on the stress distribution in bone plate. METHODS: Finite element method was employed to conduct a computational investigation. Three proximal humeral plate models with different screw hole configurations were reconstructed depended upon an identical commercialized implant. A three-dimensional model of a humerus was created using process of thresholding based on the grayscale values of the CT scanning of an intact humerus. A "virtual" subcapital osteotomy was performed. Simulations were performed under an increasing axial load. The von Mises stresses around the screw holes of the plate shaft, the construct stiffness and the directional displacement within the fracture gap were calculated for comparison. RESULTS: The mean value of the peak von Mises stresses around the screw holes in the plate shaft was the highest for combi hole design while it was smallest for the locking and dynamic holes separated design. The stiffness of the plate-bone construct was 15% higher in the locking screw only design (132.6N/mm) compared with the combi design (115.0N/mm), and it was 4% higher than the combi design for the locking and dynamic holes separated design (119.5N/mm). The displacement within the fracture gap was greatest in the combi hole design, whereas it was smallest for the locking hole only design. CONCLUSIONS: The computed results provide a possible explanation for the breakages of combi plates revealed in clinical reports. The locking and dynamic holes separated design may be a better configuration to reduce the risk of plate fracture.


Subject(s)
Fracture Fixation, Internal/methods , Humerus/surgery , Imaging, Three-Dimensional , Materials Testing/methods , Shoulder Fractures/surgery , Biomechanical Phenomena , Bone Plates , Bone Screws , Finite Element Analysis , Fracture Fixation, Internal/instrumentation , Humans , Humerus/anatomy & histology , Male , Middle Aged , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/pathology , Stress, Mechanical , Tomography, X-Ray Computed
14.
Med Eng Phys ; 38(10): 1070-5, 2016 10.
Article in English | MEDLINE | ID: mdl-27423702

ABSTRACT

Open reduction internal fixation technique has been generally accepted for treatment of midshaft clavicle fractures. Both superior and anterior clavicle plates have been reported in clinical or biomechanical researches, while presently the spiral clavicle plate design has been introduced improved biomechanical behavior over conventional designs. In order to objectively realize the multi-directional biomechanical performances among the three geometries for clavicle plate designs, a current conceptual finite element study has been conducted with identical cross-sectional features for clavicle plates. The conceptual superior, anterior, and spiral clavicle plate models were constructed for virtual reduction and fixation to an OTA 15-B1.3 midshaft transverse fracture of clavicle. Mechanical load cases including cantilever bending, axial compression, inferior bending, and axial torsion have been applied for confirming the multi-directional structural stability and implant safety in biomechanical perspective. Results revealed that the anterior clavicle plate model represented lowest plate stress under all loading cases. The superior clavicle plate model showed greater axial compressive stiffness, while the anterior clavicle plate model performed greater rigidity under cantilever bending load. Three model represented similar structural stiffness under axial torsion. Played as a transition structure between superior and anterior clavicle plate, the spiral clavicle plate model revealed comparable results with acceptable multi-directional biomechanical behavior. The concept of spiral clavicle plate design is worth considering in practical application in clinics. Implant safety should be further investigated by evidences in future mechanical tests and clinical observations.


Subject(s)
Clavicle/injuries , Finite Element Analysis , Fractures, Bone , Mechanical Phenomena , Aged , Biomechanical Phenomena , Bone Plates , Bone Screws , Clavicle/diagnostic imaging , Clavicle/surgery , Humans , Male , Tomography, X-Ray Computed
15.
Article in English | MEDLINE | ID: mdl-25569935

ABSTRACT

This paper presents a coarse-to-fine combined method for dealing with large displacement situations caused by low speed of frame rate in microscopic video sequences. Motion image estimation method utilizes the modified block matching method based on image warping to perform a wide range of changes in the amount of search comparison, and then using the optical flow method to fine adjustment pixel by pixel, to complete the overall precision of the estimation. In the evaluation experiment, we have compared both current optical flow and proposed method by testing them with simulated vessel images, the results of the estimation is quite accurate.


Subject(s)
Algorithms , Blood Flow Velocity/physiology , Erythrocytes/physiology , Animals , Brain/blood supply , Erythrocytes/cytology , Mice , Microcirculation , Microscopy, Video
SELECTION OF CITATIONS
SEARCH DETAIL