Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Medicina (Kaunas) ; 60(6)2024 May 27.
Article in English | MEDLINE | ID: mdl-38929491

ABSTRACT

Despite advancement in surgical innovation, C1-C2 fixation remains challenging due to risks of screw malposition and vertebral artery (VA) injuries. Traditional image-based navigation, while useful, often demands that surgeons frequently shift their attention to external monitors, potentially causing distractions. In this article, we introduce a microscope-based augmented reality (AR) navigation system that projects both anatomical information and real-time navigation images directly onto the surgical field. In the present case report, we discuss a 37-year-old female who suffered from os odontoideum with C1-C2 subluxation. Employing AR-assisted navigation, the patient underwent the successful posterior instrumentation of C1-C2. The integrated AR system offers direct visualization, potentially minimizing surgical distractions. In our opinion, as AR technology advances, its adoption in surgical practices and education is anticipated to expand.


Subject(s)
Augmented Reality , Humans , Female , Adult , Atlanto-Axial Joint/surgery , Atlanto-Axial Joint/injuries , Spinal Fusion/methods , Spinal Fusion/instrumentation , Odontoid Process/surgery , Odontoid Process/injuries , Odontoid Process/diagnostic imaging , Surgery, Computer-Assisted/methods
2.
NeuroRehabilitation ; 2024 Jul 25.
Article in English | MEDLINE | ID: mdl-39058455

ABSTRACT

BACKGROUND: Although rehabilitation exercise is known to be beneficial for cardiovascular and mental health, it remains a daunting challenge for patients with spinal cord injury (SCI) who rely on wheelchairs for mobility. OBJECTIVE: This study aimed to examine the effectiveness of a 4-week para table tennis program in enhancing self-efficacy and health outcomes in adults with SCI. METHODS: A total of 39 SCI patients were included and divided into the experimental group (n = 18, a 4-week para table tennis training program) and the control group (n = 21). Frequency domain indices of heart rate variability (HRV) were used to evaluate the function of the autonomic nervous system. RESULTS: Following para table tennis training, there was a significant reduction in the physical stress index (PSI, P < 0.001), accompanied by shifts in autonomic regulation of vagal dominance. Additionally, the para table tennis training led to significant improvements in vessel state, differential pulse wave index, atrial elasticity, eccentric constriction power, remaining blood volume, and self-efficacy (all P < 0.05). CONCLUSION: Para table tennis training results in favorable changes in sympathetic tone, enhanced self-efficacy, improved cardiovascular well-being, and an overall positive transformation in HRV.

3.
J Clin Med ; 13(12)2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38929945

ABSTRACT

Objectives: Cervical disc herniation (CDH) leads to pain, numbness, and potential disability. Percutaneous endoscopic cervical discectomy (PECD) offers an anterior or posterior approach. This study aims to compare postoperative disc height and angle changes one year after PECD, considering both approaches. Methods: We retrospectively reviewed the data from patients with CDH who underwent PECD from October 2017 to July 2022. Cervical disc height was measured using the preoperative and one-year postoperative magnetic resonance imaging (MRI) examinations. Lordotic angle (LA), global alignment angle (GAA), segmental alignment angle (SAA), and slippage distance (SD) at the surgical level were measured on radiographs in the neutral, flexion, and extension positions. Results: Thirty-eight patients who underwent posterior PECD (PPECD) and five patients who underwent anterior PECD (APECD) were included in the evaluation. The mean age of the patients was 47.4 years (range: 29-69 years). There was a significant difference in the preoperative and one-year postoperative GAA and SAA in extension in the PPECD group (p = 0.003 and 0.031, respectively). The mean decreased disc height one-year postoperative was 1.30 mm in the APECD group and 0.3 mm in the PPECD group by MRI. A significant disc height decrease was observed in the APECD group (p < 0.001). Conclusions: Treating CDH with PPECD or APECD is feasible, as it can relieve symptoms and reduce disability. Stability remained unaffected during the first year after surgery, even though there was an increase in angulation during extension. Despite a significant decrease in disc space following APECD, patients reported significant symptom improvement and no new symptoms.

4.
J Neurosurg Spine ; 40(6): 773-781, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38518295

ABSTRACT

OBJECTIVE: This retrospective study was designed to evaluate the incidence and predisposing factors of heterotopic ossification (HO) after cervical disc arthroplasty (CDA) with a specific implant at 1 and 2 levels, and to investigate the biomechanical effects related to HO. The study goal was to identify ways to reduce the likelihood of HO formation after surgery. METHODS: The study included patients who underwent only 1- or 2-level CDA with the Baguera C disc between November 2014 and December 2021 at a single medical center. All patients were operated on by the same neurosurgeon. The surgical indication included 1-level or 2-level disc herniation between C3 and C7 with radiculopathy, myelopathy, or both, with minimal spondylosis. The various factors were assessed by evaluating plain radiographs and cervical CT scans. The presence of HO was evaluated at different intervals postsurgery, and HO severity was graded using the McAfee classification. RESULTS: Of 107 patients who underwent CDA, 47 (43.9%) had HO at 63 of 171 levels (36.8%). Most cases with HO were grade 1, and no grade 4 was observed. Statistically significant risk factors for HO were the length of endplate coverage ratio and inferior anterior residual exposed endplate (AREE); sex, age, implant height and width, shell angle, and pre- and postoperative functional spinal unit (FSU) angle were not significant. More AREE and greater kyphotic postoperative FSU angle in the flexion position were significant factors differentiating HO grades 0 and 1 from grades 2 and 3. Furthermore, the non-HO group showed a trend of higher range of motion at any postoperative time compared to the HO group, especially at 1 month after surgery. CONCLUSIONS: The HO incidence after CDA was correlated with the residual length of endplate coverage and inferior AREE. Additionally, the AREE and kyphotic postoperative FSU angle in the flexion position were associated with HO grade progression. Patients with HO also showed a trend of lower range of motion at 1 month after surgery. Using an adequately sized implant and encouraging neck motion may help prevent HO development and progression.


Subject(s)
Cervical Vertebrae , Ossification, Heterotopic , Humans , Ossification, Heterotopic/etiology , Ossification, Heterotopic/epidemiology , Ossification, Heterotopic/diagnostic imaging , Female , Male , Risk Factors , Cervical Vertebrae/surgery , Cervical Vertebrae/diagnostic imaging , Incidence , Middle Aged , Retrospective Studies , Adult , Intervertebral Disc Displacement/surgery , Total Disc Replacement/adverse effects , Total Disc Replacement/methods , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Intervertebral Disc/surgery , Intervertebral Disc/diagnostic imaging , Aged , Arthroplasty/adverse effects , Arthroplasty/methods , Radiculopathy/surgery , Radiculopathy/etiology , Radiculopathy/epidemiology
5.
J Clin Med ; 13(2)2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38276088

ABSTRACT

BACKGROUND: This study evaluates the impact of hybrid dynamic stabilization using the Dynesys-Transition-Optima (DTO) system on adjacent segment disease (ASD) in lumbar spinal stenosis patients with spondylolisthesis. METHODS: From 2012 to 2020, 115 patients underwent DTO stabilization at a single center by a single neurosurgeon. After exclusions for lack of specific stabilization and incomplete data, 31 patients were analyzed. Follow-up was conducted at 6, 12, and 24 months postoperatively, assessing disc height, listhesis distance, and angular motion changes at L2-L3, L3-L4, and L5-S1. RESULTS: L3-L4 segment (the index level), demonstrated a delayed increase in listhesis distance, contrasting with earlier changes in other segments. At two years, L3-L4 exhibited less increase in listhesis distance and less disc height reduction compared to L2-L3 and L5-S1. Notably, the L3-L4 segment showed a significant reduction in angular motion change over two years. CONCLUSIONS: In conclusion, while ASD was not significantly prevented, the study indicates minor and delayed degeneration at the index level. The L3-L4 segment experienced reduced angular change in motion, suggesting a potential benefit of DTO in stabilizing this specific segment.

6.
J Clin Med ; 13(6)2024 Mar 10.
Article in English | MEDLINE | ID: mdl-38541814

ABSTRACT

Background: Cervical disc arthroplasty (CDA) is currently used instead of fusion to preserve cervical spine motion. Cervical implant subsidence is a potential complication after CDA. Methods: Radiological measurements were recorded via patient anteroposterior and lateral radiographs in the neutral position. Subsidence was defined as a decrease of 3 mm or more in functional spinal unit height (FSUH) from which was measured on a post-operative (OP) radiograph. Results: This study included 104 patients who underwent 153 CDA levels with the Bryan Disc. Approximately one-quarter of the implants (22.9%) showed subsidence. Binary logistic regression analysis indicated that pre-OP mean disc height (DH) was identified as an independent risk factor for subsidence in multivariate analysis (0.151, 95% Confidence Interval 0-0.073, p = 0.018). Receiver operating characteristic curve analysis (area under the curve = 0.852, sensitivity 84.7%, specificity 77.1%) revealed a cut-off value of 4.48 mm for pre-OP Mean-DH in the risk for implant subsidence. Conclusions: In this study, the subsidence rate significantly increased when the implants were oversized beyond a pre-OP Mean-DH of approximately >4 mm. Moreover, the implant subsidence incidence was higher than that reported in previous studies. This is possibly due to endplate over-preparation or disc space over-distraction during placement at the same height as the Bryan Disc (8.5 mm).

SELECTION OF CITATIONS
SEARCH DETAIL