Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Heliyon ; 10(4): e25406, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38370176

ABSTRACT

Objective: This study aims to develop a predictive model using artificial intelligence to estimate the ICU length of stay (LOS) for Congenital Heart Defects (CHD) patients after surgery, improving care planning and resource management. Design: We analyze clinical data from 2240 CHD surgery patients to create and validate the predictive model. Twenty AI models are developed and evaluated for accuracy and reliability. Setting: The study is conducted in a Brazilian hospital's Cardiovascular Surgery Department, focusing on transplants and cardiopulmonary surgeries. Participants: Retrospective analysis is conducted on data from 2240 consecutive CHD patients undergoing surgery. Interventions: Ninety-three pre and intraoperative variables are used as ICU LOS predictors. Measurements and main results: Utilizing regression and clustering methodologies for ICU LOS (ICU Length of Stay) estimation, the Light Gradient Boosting Machine, using regression, achieved a Mean Squared Error (MSE) of 15.4, 11.8, and 15.2 days for training, testing, and unseen data. Key predictors included metrics such as "Mechanical Ventilation Duration", "Weight on Surgery Date", and "Vasoactive-Inotropic Score". Meanwhile, the clustering model, Cat Boost Classifier, attained an accuracy of 0.6917 and AUC of 0.8559 with similar key predictors. Conclusions: Patients with higher ventilation times, vasoactive-inotropic scores, anoxia time, cardiopulmonary bypass time, and lower weight, height, BMI, age, hematocrit, and presurgical oxygen saturation have longer ICU stays, aligning with existing literature.

2.
Arq Bras Cardiol ; 121(7): e20230585, 2024 Jun.
Article in Portuguese, English | MEDLINE | ID: mdl-39082573

ABSTRACT

BACKGROUND: Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF). OBJECTIVE: This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position. METHODS: A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI. RESULTS: After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow - regurgitant flow) / R V end-diastolic volume ] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8). CONCLUSION: As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Tetralogy of Fallot , Humans , Tetralogy of Fallot/surgery , Tetralogy of Fallot/physiopathology , Tetralogy of Fallot/diagnostic imaging , Male , Female , Retrospective Studies , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve/surgery , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Treatment Outcome , Adult , Adolescent , Young Adult , Time Factors , Child , Echocardiography , Ventricular Function, Right/physiology , Stroke Volume/physiology , Heart Ventricles/physiopathology , Heart Ventricles/diagnostic imaging , Magnetic Resonance Imaging , Postoperative Period
3.
Arq. bras. cardiol ; 121(7): e20230585, jun.2024. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1563937

ABSTRACT

Resumo Fundamento A regurgitação valvar pulmonar é uma importante complicação de longo prazo em pacientes com tetralogia de Fallot (TF). Objetivo O presente estudo tem como objetivo investigar os efeitos do implante valvar pulmonar (IVP) na anatomia e função do ventrículo direito (VD) e na evolução em longo prazo da prótese implantada em posição pulmonar. Métodos Uma análise de coorte retrospectiva e unicêntrica foi realizada em 56 pacientes consecutivos com TF submetidos a IVP. O estudo incluiu pacientes de ambos os gêneros, com idade ≥ 12 anos e compreendeu avaliação de dados clínicos e cirúrgicos, ressonância magnética cardiovascular pré e pós-operatória e dados ecocardiográficos obtidos mais de 1 ano após IVP. Resultados Após o IVP, houve uma diminuição significativa do volume sistólico final do VD indexado pela área de superfície corpórea (ASC), de 89 mL/ASC para 69 mL/ASC (p < 0,001) e do volume diastólico final indexado do VD, de 157 mL/ASC para 116 mL/ASC (p < 0,001). Além disso, houve aumento da fração de ejeção corrigida do VD [ FEVDc = fluxo pulmonar ajustado (fluxo pulmonar anterógrado − fluxo regurgitante) / volume diastólico final do VD ] de 23% para 35% (p < 0,001) e da fração de ejeção do ventrículo esquerdo de 58% para 60% (p = 0,008). No entanto, foi observado um aumento progressivo no gradiente de pico da válvula pulmonar ao longo do tempo, com 25% dos pacientes apresentando um gradiente superior a 60 mmHg. Próteses menores (tamanhos 19 a 23) foram associadas a um risco 4,3 vezes maior de gradiente > 60 mmHg em comparação com próteses maiores (tamanhos 25 a 27; p = 0,029; intervalo de confiança: 1,18 a 17,8). Conclusão Conforme esperado, o IVP demonstrou melhorias nos volumes e na função do VD. O acompanhamento e a vigilância a longo prazo são cruciais para avaliar a durabilidade da prótese e detectar potenciais complicações. O dimensionamento adequado das próteses é essencial para melhorar a longevidade da prótese.


Abstract Background Pulmonary valve regurgitation is a significant long-term complication in patients with tetralogy of Fallot (TOF). Objective This study aims to investigate the effects of pulmonary valve implantation (PVI) on the anatomy and function of the right ventricle (RV) and the long-term evolution of the implanted prosthesis in the pulmonary position. Methods A single-center retrospective cohort analysis was performed in 56 consecutive patients with TOF who underwent PVI. The study included patients of both sexes, aged ≥ 12 years, and involved assessing clinical and surgical data, pre- and post-operative cardiovascular magnetic resonance imaging, and echocardiogram data more than 1 year after PVI. Results After PVI, there was a significant decrease in RV end-systolic volume indexed by body surface area (BSA), from 89 mL/BSA to 69 mL/BSA (p < 0.001) and indexed RV end-diastolic volume, from 157 mL/BSA to 116 mL/BSA (p < 0.001). Moreover, there was an increase in corrected RV ejection fraction [ RVEFC = net pulmonary flow (pulmonary forward flow − regurgitant flow) / R V end-diastolic volume] from 23% to 35% (p < 0.001) and left ventricular ejection fraction from 58% to 60% (p = 0.008). However, a progressive increase in the peak pulmonary valve gradient was observed over time, with 25% of patients experiencing a gradient exceeding 60 mmHg. Smaller prostheses (sizes 19 to 23) were associated with a 4.3-fold higher risk of a gradient > 60 mmHg compared to larger prostheses (sizes 25 to 27; p = 0.029; confidence interval: 1.18 to 17.8). Conclusion As expected, PVI demonstrated improvements in RV volumes and function. Long-term follow-up and surveillance are crucial for assessing the durability of the prosthesis and detecting potential complications. Proper sizing of prostheses is essential for improved prosthesis longevity.

4.
Arq. bras. cardiol ; 112(2): 130-135, Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-983830

ABSTRACT

Abstract Background: The Fontan-Kreutzer procedure (FK) was widely performed in the past, but in the long-term generated many complications resulting in univentricular circulation failure. The conversion to total cavopulmonary connection (TCPC) is one of the options for treatment. Objective: To evaluate the results of conversion from FK to TCPC. Methods: A retrospective review of medical records for patients who underwent the conversion of FK to TCPC in the period of 1985 to 2016. Significance p < 0,05. Results: Fontan-type operations were performed in 420 patients during this period: TCPC was performed in 320, lateral tunnel technique in 82, and FK in 18. Ten cases from the FK group were elected to conversion to TCPC. All patients submitted to Fontan Conversion were included in this study. In nine patients the indication was due to uncontrolled arrhythmia and in one, due to protein-losing enteropathy. Death was observed in the first two cases. The average intensive care unit (ICU) length of stay (LOS) was 13 days, and the average hospital LOS was 37 days. A functional class by New York Heart Association (NYHA) improvement was observed in 80% of the patients in NYHA I or II. Fifty-seven percent of conversions due to arrhythmias had improvement of arrhythmias; four cases are cured. Conclusions: The conversion is a complex procedure and requires an experienced tertiary hospital to be performed. The conversion has improved the NYHA functional class despite an unsatisfactory resolution of the arrhythmia.


Resumo Fundamento: O procedimento de Fontan-Kreutzer (FK) foi amplamente realizado no passado, mas a longo prazo gerou muitas complicações, resultando em falha na circulação univentricular. A conversão para conexão cavopulmonar total (CCPT) é uma das opções de tratamento. Objetivo: Avaliar os resultados da conversão de FK para CCPT. Métodos: Revisão retrospectiva de prontuários de pacientes submetidos à conversão de FK para CCPT no período de 1985 a 2016. Significância p < 0,05. Resultados: Operações do tipo Fontan foram realizadas em 420 pacientes durante este período: CCPT foi realizada em 320, técnica de túnel lateral em 82 e FK em 18. Dez casos do grupo FK foram eleitos para conversão em CCPT. Todos os pacientes submetidos à conversão de Fontan foram incluídos neste estudo. Em nove pacientes, a indicação deveu-se a arritmia não controlada e em um devido à enteropatia perdedora de proteínas. A morte foi observada nos dois primeiros casos. O tempo médio de internação na unidade de terapia intensiva (UTI) foi de 13 dias e o tempo médio de internação hospitalar foi de 37 dias. Uma classe funcional pela melhora da New York Heart Association (NYHA) foi observada em 80% dos pacientes em NYHA I ou II. Cinquenta e sete por cento das conversões devido a arritmias tiveram melhora das arritmias; quatro casos foram curados. Conclusões: A conversão é um procedimento complexo e requer que um hospital terciário experiente seja realizado. A conversão melhorou a classe funcional da NYHA, apesar de uma resolução insatisfatória da arritmia.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Young Adult , Heart Bypass, Right/methods , Fontan Procedure/methods , Univentricular Heart/surgery , Heart Failure/surgery , Arrhythmias, Cardiac/surgery , Arrhythmias, Cardiac/mortality , Time Factors , Retrospective Studies , Treatment Outcome , Statistics, Nonparametric , Heart Bypass, Right/mortality , Fontan Procedure/adverse effects , Fontan Procedure/mortality , Coronary Circulation , Kaplan-Meier Estimate , Univentricular Heart/mortality , Heart Failure/mortality , Length of Stay
5.
Rev. bras. cir. cardiovasc ; 34(5): 511-516, Sept.-Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1042045

ABSTRACT

Abstract Objective: This study aimed to evaluate Ebstein's anomaly surgical correction and its early and long-term outcomes. Methods: A retrospective analysis of 62 consecutive patients who underwent surgical repair of Ebstein's anomaly in our institution from January 2000 to July 2016. The following long-term outcomes were evaluated: survival, reoperations, tricuspid regurgitation, and postoperative right ventricular dysfunction. Results: Valve repair was performed in 46 (74.2%) patients - 12 of them using the Da Silva cone reconstruction; tricuspid valve replacement was performed in 11 (17.7%) patients; univentricular palliation in one (1.6%) patient; and the one and a half ventricle repair in four (6.5%) patients. The patients' mean age at the time of surgery was 20.5±14.9 years, and 46.8% of them were male. The mean follow-up time was 8.8±6 years. The 30-day mortality rate was 8.06% and the one and 10-year survival rates were 91.9% both. Eleven (17.7%) of the 62 patients required late reoperation due to tricuspid regurgitation, in an average time of 7.1±4.9 years after the first procedure. Conclusion: In our experience, the long-term results of the surgical treatment of Ebstein's anomaly demonstrate an acceptable survival rate and a low incidence of reinterventions.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Middle Aged , Aged , Young Adult , Tricuspid Valve/surgery , Ebstein Anomaly/surgery , Postoperative Complications/etiology , Reoperation/statistics & numerical data , Time Factors , Tricuspid Valve Insufficiency/etiology , Severity of Illness Index , Retrospective Studies , Treatment Outcome , Ventricular Dysfunction, Right/etiology , Ebstein Anomaly/complications , Ebstein Anomaly/mortality , Kaplan-Meier Estimate , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/methods , Cardiac Surgical Procedures/mortality
6.
Rev. bras. cir. cardiovasc ; 28(3): 353-363, jul.-set. 2013. tab
Article in English | LILACS | ID: lil-697221

ABSTRACT

INTRODUCTION: Characteristics of the patient and the coronary artery bypass grafting may predispose individuals to prolonged hospitalization, increasing costs and morbidity and mortality. OBJECTIVE: The objective of this study was to evaluate individual and perioperative risk factors of prolonged hospitalization in intensive care units and wards. METHODS: We conducted a case-control study of 104 patients undergoing isolated coronary artery bypass grafting with cardiopulmonary bypass. Patients hospitalized >3 days in the intensive care unit or >7 days in the ward were considered for the study. The association between variables was estimated by the chi-square test, odds ratio and logistic regression; P <0.05 was considered statistically significant. RESULTS: Hospital stay >3 days in the intensive care unit occurred for 22.1% of patients and >7 days in the ward for 27.9%. Among preoperative factors, diabetes (OR=3.17) and smoking (OR=4.07) were predictors of prolonged intensive care unit stay. Combining the pre-, intra-and postoperative variables, only mechanical ventilation for more than 24 hours (OR=6.10) was predictive of intensive care unit outcome. For the ward outcome, the preoperative predictor was left ventricular ejection fraction <50% (OR=3.04). Combining pre- and intraoperative factors, diabetes (OR=2.81), and including postoperative factors, presence of infection (OR=4.54) were predictors of prolonged hospitalization in the ward. CONCLUSION: Diabetes and smoking were predictors of intensive care unit outcome, and ejection fraction <50% of ward outcome. For the set of perioperative factors, prolonged hospitalization after isolated coronary artery bypass grafting was associated with mechanical ventilation >24 hours for the intensive care unit and presence of infection for the ward.


INTRODUÇÃO: Características do paciente e da cirurgia de revascularização do miocárdio podem predispor à internação prolongada, aumentando custos e a morbimortalidade. OBJETIVO: Avaliar fatores de risco individuais e transoperatórios para internação prolongada na unidade de terapia intensiva e na enfermaria. MÉTODOS: Realizou-se estudo de caso-controle com 104 pacientes submetidos à revascularização do miocárdio isolada sob circulação extracorpórea. Consideraram-se casos os pacientes com internação >3 para terapia intensiva ou >7 dias para enfermaria. A associação entre variáveis foi estimada pelo teste do qui-quadrado e pela razão de chances (odds ratio-OR) empregando-se a regressão logística, ao nível de P<0,05. RESULTADOS: A permanência >3 dias na terapia intensiva ocorreu em 22,1% dos pacientes e >7 dias na enfermaria em 27,9%. Entre os fatores pré-operatórios, o diabetes (OR=3,17) e o tabagismo (OR=4,07) foram os preditores para permanência prolongada na terapia intensiva. Combinando-se as variáveis pré-, intra- e pós-operatórias, somente a ventilação mecânica por mais que 24 horas (OR=6,10) foi preditora para o desfecho na terapia intensiva. Para o desfecho na enfermaria, o preditor pré-operatório foi a fração de ejeção ventricular esquerda <50% (OR=3,04). Combinando os fatores pré- e intraoperatórios, o diabetes (OR=2,81) e, somando-se os pós-operatórios, a presença de infecção (OR=4,54), foram os preditores para internação prolongada na enfermaria. CONCLUSÃO: Diabetes e tabagismo foram os preditores para o desfecho na terapia intensiva, e a fração de ejeção <50% para a enfermaria. Para o conjunto dos fatores transoperatórios, internação prolongada após revascularização do miocárdio isolada associou-se à ventilação mecânica >24 horas para terapia intensiva e à presença de infecção para a enfermaria.


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Coronary Artery Bypass/statistics & numerical data , Intraoperative Complications/etiology , Length of Stay/statistics & numerical data , Cardiopulmonary Bypass , Case-Control Studies , Diabetes Complications , Intensive Care Units/statistics & numerical data , Logistic Models , Perioperative Period , Predictive Value of Tests , Respiration, Artificial , Risk Factors , Statistics, Nonparametric , Smoking/adverse effects , Time Factors
8.
Rev. bras. cir. cardiovasc ; 24(4): 478-484, out.-dez. 2009. tab, graf
Article in English, Portuguese | LILACS | ID: lil-540749

ABSTRACT

Objetivo: A função pulmonar é apontada como preditora do tempo de hospitalização na cirurgia cardíaca. E o teste de caminhada de seis minutos (TC6') tem sido utilizado para caracterizar a capacidade funcional em pacientes cardiopatas, porém há poucos estudos que o correlacione com tempo de internação hospitalar. O objetivo desta pesquisa foi verificar se há correlação da função pulmonar pré e pós-operatória e da capacidade da deambulação pósoperatória com tempo de internação pós-operatória. Métodos: Foi realizada uma coorte prospectiva com 18 pacientes, sendo 8 do gênero masculino e 10 do gênero feminino, com idade acima de 40 anos (média 64,89 ± 6,95 anos), internados para a submissão de cirurgias de revascularização do miocárdio e/ou troca valvar. Para caracterizar a função pulmonar, os pacientes foram submetidos a uma espirometria no pré-operatório e ao 5º dia pós-operatório. Neste último período também foi realizado um teste de caminhada de 6 minutos (TC6') para caracterizar a capacidade de deambulação. RESULTADO: Não houve correlação significativa da função pulmonar pré e pós-operatória com o tempo de internação pós-operatória. Somente a distância percorrida no TC6' apresentou correlação negativa significativa (rho=-0,62) com o tempo de internação pós-operatória. A distância no TC6' obteve correlação positiva significativa com a capacidade vital forçada (r=0,59) e volume expiratório forçado no 1º segundo (r=0,52). Conclusão: Esses resultados sugerem que os pacientes com maior capacidade de deambulação no pós-operatório apresentam menor tempo de internação e sugere-se também que a distância no TC6' pode representar melhor a capacidade funcional desses pacientes do que a função pulmonar isoladamente.


Objective: The lung function is identified as a predictor of time of hospitalization in heart surgery. Meanwhile sixminute walk test has been used to establish functional capacity of cardiac patients, however there are few studies that correlate it with the length of hospital stay. The aim of this research was to determine whether there is correlation of preoperative and postoperative lung function and the ability of walking during the hospital stay. Methods: A prospective cohort with 18 patients was performed, being 8 males and 10 females, with age above 40 years (medium 64.89 ± 6.95 years). Patients where admitted for coronary artery bypass graft surgery and/or exchange valve. To characterize the pulmonary function, patients were submitted to spirometry in preoperative and the 5th postoperative day. In the latter period was also a test for 6 minutes walk (6MWT) to characterize the ability to walk. RESULTS: There was not significant correlation of preoperative and postoperative pulmonary function with length of hospital stay. Only the distance covered in 6MWT showed a significant negative correlation (rho= 0.62) with length of stay. The distance in 6MWT obtained a significant positive correlation with forced vital capacity (r=0.59) and first second of a maximal forced expiratory manoeuvre (r=0.52). Conclusion: These results suggest that patients with increased postoperative capacity to walk have a shorter time of hospitalization and it also suggest that the distance in the 6MWT can better represent the functional capacity of these patients than pulmonary function alone.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Cardiac Surgical Procedures , Exercise Test , Length of Stay/statistics & numerical data , Lung/physiopathology , Walking/physiology , Cardiac Surgical Procedures/rehabilitation , Postoperative Care , Preoperative Care , Prospective Studies , Spirometry
SELECTION OF CITATIONS
SEARCH DETAIL