N Engl J Med ; 382(19): 1823-1831, 2020 05 07.
Article in English | MEDLINE | ID: mdl-32374963

ABSTRACT

BACKGROUND: Access to pacemakers and defibrillators is problematic in places with limited resources. Resterilization and reuse of implantable cardiac devices obtained post mortem from patients in wealthier nations have been undertaken, but uncertainty around the risk of infection is a concern. METHODS: A multinational program was initiated in 1983 to provide tested and resterilized pacemakers and defibrillators to underserved nations; a prospective registry was established in 2003. Patients who received reused devices in this program were matched in a 1:3 ratio with control patients who received new devices implanted in Canada. The primary outcome was infection or device-related death, with mortality from other causes modeled as a competing risk. RESULTS: Resterilized devices were implanted in 1051 patients (mean [±SD] age, 63.2±18.5 years; 43.6% women) in Mexico (36.0%), the Dominican Republic (28.1%), Guatemala (26.6%), and Honduras (9.3%). Overall, 85% received pacemakers and 15% received defibrillators, with one (55.5%), two (38.8%), or three (5.7%) leads. Baseline characteristics did not differ between these patients and the 3153 matched control patients. At 2 years of follow-up, infections had occurred in 21 patients (2.0%) with reused devices and in 38 (1.2%) with new devices (hazard ratio, 1.66; 95% confidence interval, 0.97 to 2.83; P = 0.06); there were no device-related deaths. The most common implicated pathogens were Staphylococcus aureus and S. epidermidis. CONCLUSIONS: Among patients in underserved countries who received a resterilized and reused pacemaker or defibrillator, the incidence of infection or device-related death at 2 years was 2.0%, an incidence that did not differ significantly from that seen among matched control patients with new devices in Canada.


Subject(s)
Defibrillators, Implantable/adverse effects , Equipment Reuse , Infections/etiology , Pacemaker, Artificial/adverse effects , Adult , Aged , Case-Control Studies , Developing Countries , Female , Follow-Up Studies , Humans , Incidence , Infections/epidemiology , Kaplan-Meier Estimate , Male , Middle Aged , Mortality , Risk Factors , Sterilization
2.
Can J Cardiol ; 37(6): 835-847, 2021 06.
Article in English | MEDLINE | ID: mdl-34154798

ABSTRACT

Magnetic resonance imaging (MRI) is often considered the gold-standard test for characterizing cardiac as well as noncardiac structure and function. However, many patients with cardiac implantable electronic devices (CIEDs) and/or severe renal dysfunction are unable to undergo this test because of safety concerns. In the past 10 years, newer-generation CIEDs and gadolinium-based contrast agents (GBCAs) as well as coordinated care between imaging and heart rhythm device teams have mitigated risk to patients and improved access to MRI at many hospitals. The purpose of this statement is to review published data on safety of MRI in patients with conditional and nonconditional CIEDs in addition to patient risks from older and newer GBCAs. This statement was developed through multidisciplinary collaboration of pan-Canadian experts after a relevant and independent literature search by the Canadian Agency for Drugs and Technologies in Health. All recommendations align with the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Key recommendations include: (1) the development of standardized protocols for patients with a CIED undergoing MRI; (2) patients with MRI nonconditional pacemakers and pacemaker dependency should be programmed to asynchronous mode and those with MRI nonconditional transvenous defibrillators should have tachycardia therapies turned off during the scan; and (3) macrocyclic or newer linear GBCAs should be used in preference to older GBCAs because of their better safety profile in patients at higher risk of nephrogenic systemic fibrosis.


Subject(s)
Cardiovascular Diseases/therapy , Magnetic Resonance Imaging/methods , Practice Patterns, Physicians' , Risk Adjustment/methods , Canada , Clinical Protocols/standards , Defibrillators, Implantable/adverse effects , Humans , Image Enhancement/methods , Inventions/standards , Inventions/trends , Magnetic Resonance Imaging/trends , Pacemaker, Artificial/adverse effects , Patient Safety/standards , Practice Patterns, Physicians'/organization & administration , Practice Patterns, Physicians'/trends , Quality Improvement
3.
Can J Cardiol ; 33(12): 1633-1638, 2017 12.
Article in English | MEDLINE | ID: mdl-28987521

ABSTRACT

BACKGROUND: To our knowledge, heart rate responses have not previously been assessed in hockey fans. We quantified heart rate increases in spectators of the Montreal Canadiens, compared televised with live games, explored features associated with peak heart rates, and assessed whether increases correlate with a fan passion score. METHODS: Healthy adults were enrolled, with half attending live games and half viewing televised games. All subjects completed questionnaires and had continuous Holter monitoring. Intensity of the physical stress response was defined according to previously published heart rate index thresholds as mild (< 1.33), moderate (1.33-1.83), or vigorous (> 1.83). RESULTS: In 20 participants, 35% women, age 46 ± 10 years, the heart rate increased by a median of 92% during the hockey game, from 60 (interquartile range, 54-65) beats per minute at rest to 114 (interquartile range, 103-129) beats per minute (P < 0.001). The heart rate increased by 110% vs 75% during live vs televised games (P < 0.001). Heart rate index (2.16 ± 0.27 vs 1.73 ± 0.15; P < 0.001) and percent maximum predicted heart rate attained (75% ± 8% vs 58% ± 7%; P < 0.001) were significantly higher during live vs televised games. Number of premature beats was nonsignificantly higher during live games (5 vs 1; P = 0.181). The fan passion score was not predictive of the heart rate response (P = 0.753). Peak heart rates most commonly occurred during overtime (40%) and scoring opportunities for (25%) and against (15%). CONCLUSIONS: It is exciting to watch the Montreal Canadiens! Viewing a live hockey game is associated with a heart rate response equivalent to vigorous physical stress and a televised game to moderate physical stress.


Subject(s)
Heart Rate/physiology , Hockey/physiology , Stress, Physiological/physiology , Adolescent , Adult , Electrocardiography, Ambulatory , Female , Healthy Volunteers , Humans , Male , Middle Aged , Oxygen Consumption/physiology , Quebec , Young Adult
SELECTION OF CITATIONS