Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Catheter Cardiovasc Interv ; 97(3): 431-436, 2021 02 15.
Article in English | MEDLINE | ID: mdl-32077590

ABSTRACT

BACKGROUND: Quantitative flow ratio (QFR) has been validated as an accurate surrogate of standard wire-based fractional flow reserve. The clinical and angiographic outcomes of the Fantom sirolimus-eluting bioresorbable coronary scaffold (BRS) have been previously studied and reported. We investigate the functional performance of the Fantom BRS. METHODS: The FANTOM II trial prospectively enrolled 240 patients with stable coronary artery disease or unstable angina, of which 235 patients received the Fantom BRS and were included in the present analysis. We performed an independent serial QFR analysis of the target vessel at baseline, post-percutaneous coronary intervention (PCI), and at 6- or 9-month and 24-month follow-up, using a QFR threshold ≤0.80 to define functional ischemia. RESULTS: QFR was analyzable in 178 patients at baseline, 185 post-PCI, 178 at 6- or 9-month follow-up, and 30 at 24-month follow-up. At baseline, 119 patients (66.9%) had a QFR ≤0.80, whereas 12 (6.5%) post-PCI, 13 (7.3%) at 6- or 9-month follow-up, and 3 (10.0%) at 24-month follow-up had a QFR ≤0.80. QFR improved from baseline to post-PCI, and decreased from post-PCI up to 24-month follow-up. During follow-up period, 28 patients (11.9%) had target vessel revascularization, of which 21 had analyzable QFR and 16 patients (76.1%) had QFR ≤0.80 at the time of revascularization. CONCLUSIONS: Off-line serial QFR assessment demonstrated that around 30% patients did not have functionally significant lesions at baseline and the time with target vessel revascularization. PCI with the Fantom BRS improved functional ischemia with a slight decrease in QFR values over 24 months.


Subject(s)
Coronary Artery Disease , Fractional Flow Reserve, Myocardial , Percutaneous Coronary Intervention , Absorbable Implants , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Humans , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Sirolimus , Treatment Outcome
2.
Int J Cardiol Heart Vasc ; 38: 100942, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35079620

ABSTRACT

BACKGROUND: The new EuroCTO CASTLE Score was validated against the widely adopted Japanese Multicenter CTO Registry (J-CTO) score in predicting technical success in percutaneous coronary intervention (PCI) for coronary chronic total occlusions (CTO). METHODS: A total of 463 patients treated by CTO PCI were included in a retrospective analysis. Result: The mean CASTLE score was 2.23 ± 1.1 and J-CTO score was 2.84 ± 1.0. The overall technical success rate was 83.2%. At 30 days follow up, a primary composite safety endpoint showed a low proportion of stent thrombosis (0.2%) and re-hospitalization (0.4%). Moreover, an improvement of clinical symptoms was found in 83% of patients. Receiver operating characteristic analysis (ROC) demonstrated a comparable overall discriminatory performance in predicting technical outcome: CASTLE score, area under the ROC curve (AUC) 0.668, 95% CI: 0.606-0.730; J-CTO score AUC 0.692, 95% CI: 0.631-0.752; Comparison of AUCs: p = 0.324. Those findings were even consistent in more complex procedures CASTLE Score ≥ 4 and J-CTO score ≥ 3: CASTLE Score AUC 0.514, 95% CI: 0.409-0.619; J-CTO score, AUC 0.617, 95% CI: 0.493-0.741; Comparison of AUCs: p = 0.211. Furthermore, increasing score values are accompanied by a longer examination and fluoroscopy time, more contrast medium and a higher dose area product. CONCLUSION: Compared to the widely accepted J-CTO score, the new introduced EuroCTO CASTLE score demonstrated a comparable overall discriminatory performance in predicting technical outcomes in CTO PCI.

3.
EuroIntervention ; 17(12): e966-e970, 2021 Dec 17.
Article in English | MEDLINE | ID: mdl-34338644

ABSTRACT

Dual lumen microcatheters (DLMC) have become indispensable tools in the setting of percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Other than allowing preservation and treatment of bifurcated coronary branches within or in the proximity of the CTO body, they enable the use of modified parallel wiring, antegrade dissection and re-entry, collateral selection and retrograde negotiation of the distal CTO cap. This EuroCTO consensus document describes current DLMC and suggests a practical guide to anatomies and techniques in which these devices are applicable.


Subject(s)
Percutaneous Coronary Intervention , Humans , Percutaneous Coronary Intervention/adverse effects
4.
Circ Cardiovasc Interv ; 12(6): e007283, 2019 06.
Article in English | MEDLINE | ID: mdl-31177821

ABSTRACT

Background A novel bioresorbable scaffold, the sirolimus-eluting Fantom, incorporates a radiopaque polymer, struts with a thickness of 125 µm, and a crossing profile of 1.35 mm. The purpose of this study was to evaluate the 9-month angiographic and 12-month clinical outcomes of the FANTOM scaffold in a larger patient population. Methods and Results The FANTOM II study (Safety & Performance Study of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold - First Report on Initial 24 Month Outcomes) was a prospective, multicenter trial which enrolled 240 patients with single de novo coronary stenosis with reference vessel diameter 2.5 to 3.5 mm diameter and lesion length ≤20 mm. Major adverse cardiac events through 12-month follow-up were assessed. Angiographic follow-up was performed in consecutive patient cohorts at 6 months (n=117) and 9 months (n=123). Acute delivery success, acute technical success, acute procedural success, and clinical procedural success rates as defined in the clinical protocol were 97.9% (235/240), 95.8% (230/240), 99.1% (228/230), and 99.6% (227/228), respectively. The mean in-stent late lumen loss at 6 months and 9 months were 0.25±0.40 mm and 0.33±0.36 mm, respectively, and in-segment binary restenosis occurred in 2.0% and 7.6% of patients, respectively. Major adverse cardiac events and target lesion failure through 12 months occurred in 4.2% of 240 patients; scaffold thrombosis developed in only one patient (0.4%). Conclusions The Fantom sirolimus-eluting bioresorbable coronary scaffold demonstrated favorable safety and effectiveness performance at 12-month follow-up. Longer-term follow-up is ongoing to examine the late outcomes with this novel device. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02539966.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Angiography , Coronary Stenosis/therapy , Sirolimus/administration & dosage , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/adverse effects , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Stenosis/diagnostic imaging , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/etiology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Severity of Illness Index , Sirolimus/adverse effects , Time Factors , Treatment Outcome
6.
Open Heart ; 6(1): e000941, 2019.
Article in English | MEDLINE | ID: mdl-30997130

ABSTRACT

Objectives: We aimed to evaluate the mechanical properties and healing patterns 6 and 9 months after implantation of the sirolimus-eluting Fantom bioresorbable scaffold (BRS). Background: The Fantom BRS (Reva Medical, San Diego, USA) has differentiating properties including radiopacity, strut thickness of 125 µm, high expansion capacity and has demonstrated favourable mid-term clinical and angiographic outcomes. Methods and results: FANTOM II was a prospective, single arm study with implantation of the Fantom BRS in 240 patients with stable angina pectoris. Guidance by optical coherence tomography (OCT) was encouraged and was repeated at 6-month (cohort A) or 9-month follow-up (cohort B). Matched baseline and follow-up OCT recordings were available in 152 patients. In-scaffold mean lumen area in cohort A was 6.8±1.7 mm2 and 5.7±1.4 mm2 at baseline and follow-up (p<0.0001) and was 7.2±1.6 mm2 and 5.6±1.4 mm2 in cohort B (p<0.0001). Mean scaffold area remained stable from 7.1±1.5 mm2 at baseline to 7.2±1.4 mm2 at 6 months (p=0.12), and from 7.4±1.5 mm2 to 7.3±1.4 mm2 at 9 months. Strut malapposition was median 0.8 (IQR 0.0;3.5)% and 1.8 (IQR 0.3;6.0)% at baseline and was 0.0 (IQR 0.0;0.0)% in both groups at 6-month and 9-month follow-up. Strut tissue coverage was 98.1 (IQR 95.9;99.4)% at 6 months and 98.9 (IQR 98.3;100.0)% at 9 months. Conclusions: The novel Fantom BRS had favourable healing patterns at 6-month and 9-month follow-up as malapposition was effectively resolved and strut coverage was almost complete. The scaffold remained stable through follow-up with no signs of systematic late recoil.

7.
EuroIntervention ; 14(11): e1215-e1223, 2018 Dec 07.
Article in English | MEDLINE | ID: mdl-30222116

ABSTRACT

AIMS: FANTOM II is a prospective multicentre trial assessing the safety and efficacy of the Fantom sirolimus-eluting bioresorbable coronary scaffold (BRS). The present substudy focuses on the six- and nine-month IVUS findings. METHODS AND RESULTS: A total of 240 patients with de novo coronary artery lesions presenting with stable or unstable disease were included in two sequential cohorts (cohort A [n=117] and cohort B [n=123]) in which angiographic follow-up was performed at either six or nine months, respectively. Matched IVUS data were available for 35 paired cases in cohort A and 26 paired cases in cohort B. At six months, mean and minimum scaffold area (SA) decreased from 6.09±1.08 mm2 to 5.88±1.07 mm2, p=0.009, and 5.27±0.99 mm2 to 5.05±0.99 mm2, p=0.01, respectively. At nine months, no significant change in mean scaffold and minimum scaffold area was observed (6.46±1.11 mm2 to 6.38±0.96 mm2; p=0.35, and 5.45±1.00 mm2 to 5.36±0.86 mm2; p=0.32, respectively). Neointimal hyperplasia area was low at both six (0.11±0.12 mm2) and nine months (0.20±0.21 mm2), as was in-scaffold obstruction volume (1.94±2.25% at six months, and 3.40±4.11% at nine months). CONCLUSIONS: The use of the Fantom BRS in stable coronary artery disease was associated with low rates of neointimal hyperplasia volume and in-scaffold volume obstruction at both six and nine months.


Subject(s)
Coronary Artery Disease , Sirolimus , Absorbable Implants , Coronary Angiography , Coronary Vessels , Humans , Prospective Studies , Treatment Outcome , Ultrasonography, Interventional
8.
JACC Cardiovasc Interv ; 10(18): 1832-1838, 2017 09 25.
Article in English | MEDLINE | ID: mdl-28935075

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the outcomes of the novel Fantom coronary bioresorbable scaffold at 6 months. BACKGROUND: The Fantom sirolimus-eluting bioresorbable scaffold incorporates a unique proprietary iodinated, polycarbonate copolymer of tyrosine analogs that is radiopaque, with thin struts (125 µm) that facilitate device delivery and precise target lesion treatment. METHODS: The 6-month outcomes and performance of the Fantom scaffold were evaluated in 117 patients with single de novo native coronary artery lesions of length ≤20 mm and reference vessel diameter 2.5 to 3.5 mm. The primary angiographic endpoint was mean late lumen loss at 6 months measured by quantitative coronary angiography. Procedural outcomes were categorized as short-term technical success, short-term procedural success, and clinical procedural success. The primary clinical endpoint was major adverse cardiac events at 6 months, the composite of cardiac death, myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). RESULTS: Short-term technical success, short-term procedural success, and clinical procedural success were achieved in 96.6%, 99.1%, and 99.1% of patients, respectively. Mean 6-month in-stent late lumen loss was 0.25 ± 0.40 mm (n = 100). Binary restenosis was present in 2 patients (2.0%). Major adverse cardiac events within 6 months occurred in 3 patients (2.6%), including no deaths, 2 MIs, and 2 TLRs (1 patient had both an MI and TLR). Scaffold thrombosis occurred in 1 patient (0.9%). CONCLUSIONS: The clinical results from 117 patients enrolled in cohort A of the multicenter FANTOM II (Safety & Performance Study of the FANTOM Sirolimus-Eluting Bioresorbable Coronary Scaffold) study demonstrate favorable 6-month outcomes of this novel device in the treatment of noncomplex coronary artery disease.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Angiography , Coronary Artery Disease/therapy , Coronary Stenosis/therapy , Sirolimus/administration & dosage , Aged , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/mortality , Female , Humans , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/etiology , Predictive Value of Tests , Prosthesis Design , Risk Factors , Sirolimus/adverse effects , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL