Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Country/Region as subject
Language
Affiliation country
Publication year range
1.
Vox Sang ; 119(3): 242-251, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38156504

ABSTRACT

BACKGROUND AND OBJECTIVES: Confirmed COVID-19 diagnoses underestimate the total number of infections. Blood donors can provide representative seroprevalence estimates, which can be leveraged into reasonable estimates of total infection counts and infection fatality rate (IFR). MATERIALS AND METHODS: Blood donors who donated after each of three epidemic waves (Beta, Delta and first Omicron waves) were tested for anti-SARS-CoV-2 nucleocapsid antibodies using the Roche Elecsys anti-SARS-CoV-2 total immunoglobulin assay. Roche Elecsys anti-spike antibody testing was done for the post-Omicron sampling. Prevalence of antibodies was estimated by age, sex, race and province and compared to official case reporting. Province and age group-specific IFRs were estimated using external excess mortality estimates. RESULTS: The nationally weighted anti-nucleocapsid seroprevalence estimates after the Beta, Delta and Omicron waves were 47% (46.2%-48.6%), 71% (68.8%-73.5%) and 87% (85.5%-88.4%), respectively. There was no variation by age and sex, but there were statistically and epidemiologically significant differences by province (except at the latest time point) and race. There was a 13-fold higher seroprevalence than confirmed case counts at the first time point. Age-dependent IFR roughly doubled for every 10 years of age increase over 6 decades from 0.014% in children to 6.793% in octogenarians. CONCLUSION: Discrepancies were found between seroprevalence and confirmed case counts. High seroprevalence rates found among Black African donors can be ascribed to historical inequities. Our IFR estimates were useful in refining previous large disagreements about the severity of the epidemic in South Africa. Blood donor-based serosurveys provided a valuable and efficient way to provide near real-time monitoring of the ongoing SARS-CoV-2 outbreak.


Subject(s)
Blood Donors , COVID-19 , Child , Aged, 80 and over , Humans , South Africa , SARS-CoV-2 , Seroepidemiologic Studies , Antibodies, Viral
2.
PLoS One ; 19(6): e0303393, 2024.
Article in English | MEDLINE | ID: mdl-38843247

ABSTRACT

INTRODUCTION: Viral Load (VL) monitoring is a crucial component of patient care during antiretroviral therapy (ART) but is not routinely available in many resource-constrained settings, where millions of patients will require care for decades to come. We hypothesise a serologic 'recent infection' test (Sedia LAg assay) which has a high dynamic range for detecting antigen-driven antibody response can provide informative proxies for VL trajectories. METHODS: A retrospective study where we analysed data linked via specimens in a well-described repository for recent infection test benchmarking (CEPHIA collaboration). Patient panels were comprised of 1) observations straddling ART start; 2) observations from a period of stable viral suppression; 3) observations straddling rebound after a period of viral suppression. We analysed an individual's Sedia LAg ELISA normalised optical density (ODn) trends within these categories. Using groups 2) and 3) we evaluated the specificity and sensitivity of a proposed proxy for "the latest observation is at a time of VL rebound"; proxy was defined as follows: we estimated patient-specific mean-previous-ODn for all observations with at least two preceding virally suppressed observations. We considered various thresholds to define both "VL suppression" and "ODn uptick". RESULTS: In regression analysis by category: 1) ODn gradients are statistically significantly negative just after ART-start (p = 0.010); 2) During periods of stable viral suppression, ODn tended to decline, but not statistically significantly, for a range of clinically meaningful "VL suppression" thresholds; 3) comparing ODn values just before, versus at, "VL rebound", ODn changes were statistically significantly increasing at rebound (p = 0.001). In the analysis comparing groups 2) and 3), at a Z score threshold of 0.8, the proposed proxy for a first viral rebound had an observed specificity and sensitivity both close to 90%. CONCLUSION: The high dynamic range of serological tests previously investigated for defining 'recent infection' has potential, as demonstrated using the Sedia LAg ELISA, to provide meaningful information about the success of ART, during treatment initiation, at times of stable suppression, and to flag possible viral rebound. It should be investigated how this can be combined with patient management workflows and (clinical and) other data, to provide efficiencies in long-term monitoring viral control in resource-limited settings.


Subject(s)
HIV Infections , Viral Load , Humans , HIV Infections/drug therapy , HIV Infections/immunology , HIV Infections/virology , Retrospective Studies , Male , Female , Adult , Enzyme-Linked Immunosorbent Assay/methods , Sensitivity and Specificity , Middle Aged , Anti-Retroviral Agents/therapeutic use , HIV-1/immunology
SELECTION OF CITATIONS
SEARCH DETAIL