Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters

Database
Language
Journal subject
Publication year range
1.
Opt Express ; 32(10): 17336-17344, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38858919

ABSTRACT

The ensemble of nitrogen-vacancy (NV) centers is widely used in quantum information transmission, high-precision magnetic field, and temperature sensing due to their advantages of long-lived state and the ability to be pumped by optical cycling. In this study, we investigate the zero-phonon line behavior of the two charge states of NV centers by measuring the photoluminescence of the NV center at 1.6 K-300 K. The results demonstrate a positional redshift, an increase in line width, and a decrease in fluorescence intensity for the ZPL of NV0 and NV- as the temperature increased. In the range of 10 K to 140 K, the peak shift with high concentrations of NV- revealed an anomaly of bandgap reforming. The peak position undergoes a blueshift and then a redshift as temperature increases. Furthermore, the transformation between NV0 and NV- with temperature changes has been obtained in diamonds with different nitrogen concentrations. This study explored the ZPL characteristics of NV centers in various temperatures, and the findings are significant for the development of high-resolution temperature sensing and high-precision magnetic field sensing in ensemble NV centers.

2.
Opt Express ; 32(3): 3184-3193, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38297545

ABSTRACT

In this paper, we propose a method for simultaneously recovering multiple radio wave signals based on nitrogen-vacancy (NV) centers in diamond combining optically detected magnetic resonance (ODMR) spectrum. A controlled magnetic field gradient applied to the laser excitation area on the surface of diamond widens the detectable ODMR bandwidth to 200 MHz. Three different frequency-modulated (FM) signals with distinct carrier frequencies falling within the resonance frequency range are received and demodulated in real-time. Subsequently, the FM signal reception capability of this system is further investigated by measuring baseband signal frequencies ranging from 0.1 Hz to 200 Hz and adjusting the carrier power within a dynamic range from -10 dBm to 30 dBm. This proposal, which accomplishes multi-channel demodulation using a compact and single device, has potential applications in fields such as wireless communication, radar and navigation.

3.
Opt Express ; 32(7): 10829-10840, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38570946

ABSTRACT

Imaging of electronic device surface or sub-surface electromagnetic fields under operating conditions is important for device design and diagnosis. In this study, we proposed a method to characterize specific magnetic field properties of electromagnetic devices at micron-scale using a solid-state quantum sensor, namely diamond nitrogen-vacancy (NV) centers. By employing a wide-field magnetic field measurement technique based on NV centers, we rapidly obtain the first-order magnetic field distribution of anomalous regions. Furthermore, we approximate the second-order magnetic field (magnetic gradient tensor) using the differential gradient method. To visualize the electromagnetic anomalous regions boundary, we utilize the tensor invariants of the magnetic gradient tensor components, along with their nonlinear combinations. The identification error rate of the anomalous regions is within 12.5%. Additionally, the electromagnetic field of anomalous regions is simulated showing the measurement accuracy. Our study shows that the experimental results are very similar to the theoretical simulation of the electromagnetic field (error: 7%). This work is essential for advancing electromagnetic field characterization of electronic devices and the advancement of quantum magnetic sensor applications.

SELECTION OF CITATIONS
SEARCH DETAIL