ABSTRACT
The severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) Omicron was classified as a variant of concern in November 2021. The sublineage BA.2 spreads rapidly worldwide. Currently, there is a lack of data for the parallel comparison of Rapid Antigen Test (RAT) Kits to detect SARS-CoV-2 Omicron BA.2. We evaluated the analytical sensitivity of 12 RAT kits to detect Omicron BA.2 in the present study. Analytical sensitivity was determined by means of the limit of detection (LOD). We prepared a dilution set using a respiratory specimen collected from a COVID-19 patient infected by Omicron BA.2. The reverse transcription-polymerase chain reaction was used as a reference method. The LOD results showed that all 12 RAT kits had comparable analytical sensitivity to detect Omicron BA.2. The RAT kits selected in the current study may be used for the first-line screening of the rapid spreading Omicron BA.2.
Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , Humans , Immunologic Tests , RNA, Viral/analysis , SARS-CoV-2/geneticsABSTRACT
The music-with-movement intervention is particularly suitable for people with dementia because their gross motor ability is preserved until the later stage of dementia. This study examines the effect of music-with-movement on reducing anxiety, sleep disturbances, and improving the wellbeing of people with dementia. This paper reports the first stage of the study - developing the intervention protocol that staff can use to teach family caregivers. A registered music therapist developed a music-with-movement protocol and taught staff of two social service centers over five weekly 1.5 h sessions, with center-in-charges (social workers and occupational therapists) and our research team joining these sessions to provide comments from their professional perspective. Each discipline had different expectations about the content; therefore, numerous meetings and discussions were held to bridge these differences and fine-tune the protocol. Few healthcare professionals doubt the merits of interdisciplinary collaboration at all levels of health promotion. In practice, interdisciplinary collaboration is complex and requires commitment. Openness and persistence is required from all stakeholders to achieve a successful intervention for consumers.
Subject(s)
Caregivers/psychology , Dementia/nursing , Dementia/psychology , Interdisciplinary Communication , Motor Skills , Music Therapy , Aged , Evidence-Based Nursing , Female , Humans , Male , Treatment OutcomeABSTRACT
Background: Standardized and validated heat inactivation procedure for Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) are not available. For heat inactivation, various protocols were reported to prepare External Quality Assessment Programme (EQAP) samples without direct comparison between different durations. Objective: To assess the heat inactivation procedures against SARS-CoV-2. The efficacy of the optimized condition was reflected by the results from laboratories testing the EQAP samples. Study design: The SARS-CoV-2 strain was exposed to 95 °C in a water bath for three different time intervals, 5 min, 10 min and 15 min, respectively. The efficacy of inactivation was confirmed by the absence of cytopathic effects and decreasing viral load in 3 successive cell line passages. The viral stock inactivated by the optimal time interval was dispatched to EQAP participants and the result returned were analyzed. Results: All of the three conditions were capable of inactivating the SARS-CoV-2 of viral load at around cycle threshold value of 10. When the 95 °C 10 min condition was chosen to prepare SARS-CoV-2 EQAP samples, they showed sufficient homogeneity and stability. High degree of consensus was observed among EQAP participants in all samples dispatched. Conclusions: The conditions evaluated in the present study could be helpful for laboratories in preparing SARS-CoV-2 EQAP samples.
ABSTRACT
Several severe respiratory virus infections that have emerged during the past decade originated in animals, including bats. In Indonesia, exposure to bats has been associated with increased risk of acquiring orthoreovirus infection. Although orthoreovirus infections are mild and self-limiting, we explored their potential for evolution into a more virulent form. We used conventional virus culture, electron microscopy, and molecular sequencing to isolate and identify orthoreoviruses from 3 patients in whom respiratory tract infection developed after travel to Indonesia. Virus characterization by plaque-reduction neutralization testing showed antigenic similarity, but sequencing of the small segment genes suggested virus reassortment, which could lead to increased virulence. Bats as a reservoir might contribute to virus evolution and genetic diversity, giving orthoreoviruses the potential to become more virulent. Evolution of this virus should be closely monitored so that prevention and control measures can be taken should it become more virulent.
Subject(s)
Orthoreovirus/pathogenicity , Reoviridae Infections/virology , Adult , Animals , Antibodies, Neutralizing/blood , Cells, Cultured , Dogs , Female , Giant Cells/virology , Humans , Macaca mulatta , Male , Middle Aged , Orthoreovirus/genetics , Orthoreovirus/isolation & purification , Phylogeny , Reoviridae Infections/blood , Reoviridae Infections/immunology , Sequence Analysis, DNA , Viral Plaque Assay , Virulence , Virus CultivationABSTRACT
BACKGROUND: Currently, there are two rapid antigen detection (RAD) kits from the WHO Emergency Use List for detecting SARS-CoV-2. OBJECTIVE: The Panbio COVID-19 Ag Rapid Test Device was selected to evaluate the performance for detecting SARS-CoV-2. STUDY DESIGN: Analytical sensitivity for the detection of SARS-CoV-2 virus was determined by limit of detection (LOD) using RT-PCR as a reference method. Clinical sensitivity was evaluated by using respiratory specimens collected from confirmed COVID-19 patients. RESULTS: The LOD results showed that the RAD kit was 100 fold less sensitive than RT-PCR. Clinical sensitivity of the RAD kit was 68.6 % for detecting specimens from COVID-19 patients. CONCLUSIONS: The RAD kit evaluated in the present study shared similar performance with another kit from the WHO Emergency Use List, the Standard Q COVID-19 Ag. Understanding the clinical characteristics of RAD kits can guide us to decide different testing strategies in different settings.
Subject(s)
Antigens, Viral/analysis , COVID-19/diagnosis , Reagent Kits, Diagnostic/standards , SARS-CoV-2/immunology , COVID-19/pathology , COVID-19/virology , COVID-19 Testing/methods , Cross Reactions , Hong Kong , Humans , Limit of Detection , Nasopharynx/virology , Pharynx/virology , Reverse Transcriptase Polymerase Chain Reaction , SARS-CoV-2/pathogenicity , World Health OrganizationABSTRACT
RT-PCR is the gold standard to detect SARS-CoV-2, however, its capacity is limited. We evaluated an automated antigen detection (AAD) test, Elecsys SARS-CoV-2 Antigen (Roche, Germany), for detecting SARS-CoV-2. We compared the limit of detection (LOD) between AAD test, rapid antigen detection (RAD) test; SARS-CoV-2 Rapid Antigen Test (SD Biosensor, Korea), and in-house RT-PCR test. LOD results showed that the AAD test was 100 fold more sensitive than the RAD test, while the sensitivity of the AAD test was comparable to the RT-PCR test. The AAD test detected between 85.7% and 88.6% of RT-PCR-positive specimens collected from COVID-19 patients, false negative results were observed for specimens with Ct values >30. Although clinical sensitivity for the AAD test was not superior or comparable to the RT-PCR test in the present study, the AAD test may be an alternative to RT-PCR test in terms of turn-around time and throughput.
Subject(s)
Antigens, Viral/isolation & purification , COVID-19 Serological Testing/methods , COVID-19/virology , Reagent Kits, Diagnostic , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , COVID-19 Nucleic Acid Testing , Diagnostic Tests, Routine , Humans , Limit of Detection , Sensitivity and Specificity , Viral LoadABSTRACT
BACKGROUND: To diagnose influenza A(H1N1)v virus infection, accurate and rapid detection are important. However, there is scanty data on the performance of various laboratory diagnostics. OBJECTIVE: To compare the performance of rapid antigen test (RAT), viral culture and RT-PCR for the detection of influenza A(H1N1)v virus and to correlate their performance with the time after symptom onset and viral load. STUDY DESIGN: From May 1, 2009 to June 25, 2009, respiratory samples were collected from 5740 individuals suspected of having influenza A(H1N1)v infection. The performance of viral culture and RT-PCR were investigated and correlated with the time after symptom onset. The sensitivity of RAT ESPLINE influenza A & B-N (Fujirebio Inc, Tokyo) was evaluated using a subset of 60 samples from patients diagnosed as having influenza A(H1N1)v infection. RESULTS: Using respiratory samples from 587 patients diagnosed with influenza A(H1N1)v infection, comparison of laboratory diagnostics showed viral culture and RT-PCR gave comparable results with overall sensitivity of 93.9% and 98.1%, respectively. For RAT, when testing a subset of 60 samples collected < or =3 days following symptom onset, the sensitivity was 62%. CONCLUSIONS: Although viral shedding is prolonged and of higher titre in influenza A(H1N1)v infection, RAT showed a low sensitivity of 62% among patients presenting < or =3 days after symptom onset. Viral culture showed comparable performance with RT-PCR and with sensitivity better than that documented for seasonal influenza.