Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 238
Filter
Add more filters

Publication year range
1.
Circulation ; 146(17): 1268-1280, 2022 10 25.
Article in English | MEDLINE | ID: mdl-35862109

ABSTRACT

BACKGROUND: Clinical and anatomical characteristics are often considered key factors in deciding between percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) in patients with complex coronary artery disease (CAD) such as left-main CAD or 3-vessel disease. However, little is known about the interaction between self-reported preprocedural physical/mental health and clinical outcomes after revascularization. METHODS: This subgroup analysis of the SYNTAXES trial (SYNTAX Extended Survival), which is the extended follow-up of the randomized SYNTAX trial (Synergy Between PCI With Taxus and Cardiac Surgery) comparing PCI with CABG in patients with left-main CAD or 3-vessel disease, stratified patients by terciles of Physical (PCS) or Mental Component Summary (MCS) scores derived from the preprocedural 36-Item Short Form Health Survey, with higher PCS and MCS scores representing better physical and mental health, respectively. The primary end point was all-cause death at 10 years. RESULTS: A total of 1656 patients with preprocedural 36-Item Short Form Health Survey data were included in the present study. Both higher PCS and MCS were independently associated with lower 10-year mortality (10-point increase in PCS adjusted hazard ratio, 0.84 [95% CI, 0.73-0.97]; P=0.021; in MCS adjusted hazard ratio, 0.85 [95% CI, 0.76-0.95]; P=0.005). A significant survival benefit with CABG over PCI was observed in the highest PCS (>45.5) and MCS (>52.3) terciles with significant treatment-by-subgroup interactions (PCS Pinteraction=0.033, MCS Pinteraction=0.015). In patients with both high PCS (>45.5) and MCS (>52.3), 10-year mortality was significantly higher with PCI compared with CABG (30.5% versus 12.2%; hazard ratio, 2.87 [95% CI, 1.55-5.30]; P=0.001), whereas among those with low PCS (≤45.5) or low MCS (≤52.3), there were no significant differences in 10-year mortality between PCI and CABG, resulting in a significant treatment-by-subgroup interaction (Pinteraction=0.002). CONCLUSIONS: Among patients with left-main CAD or 3-vessel disease, patient-reported preprocedural physical and mental health status was strongly associated with long-term mortality and modified the relative treatment effects of PCI versus CABG. Patients with the best physical and mental health had better 10-year survival with CABG compared with PCI. Assessment of self-reported physical and mental health is important when selecting the optimal revascularization strategy. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; SYNTAXES Unique identifier: NCT03417050. URL: https://www. CLINICALTRIALS: gov; SYNTAX Unique identifier: NCT00114972.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Coronary Artery Disease/surgery , Mental Health , Patient Reported Outcome Measures , Risk Factors , Treatment Outcome , Randomized Controlled Trials as Topic
2.
Neth Heart J ; 31(12): 489-499, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37910336

ABSTRACT

OBJECTIVE: The importance of revascularisation of significant coronary artery disease (CAD) in patients undergoing transcatheter aortic valve implantation (TAVI) is unclear. Despite the lack of randomised controlled trials comparing different revascularisation strategies, guidelines currently recommend percutaneous coronary intervention (PCI) in patients with significant proximal CAD undergoing TAVI. METHODS: In this systematic review and meta-analysis, a systematic search was conducted to identify studies comparing TAVI with and without PCI in patients with significant CAD on pre-TAVI coronary angiography. Endpoints were all-cause mortality, cardiac death, stroke, myocardial infarction and major bleeding. RESULTS: In total, 14 studies were included, involving 3838 patients, of whom 1806 (47%) underwent PCI before TAVI. All-cause mortality did not differ significantly between TAVI with and without preceding PCI at 30 days, 1 year and > 1 year. There were no significant differences in risk of cardiac death, stroke or myocardial infarction between the groups. However, TAVI performed with PCI resulted in a higher risk of major bleeding within 30 days after TAVI (odds ratio: 0.66; 95% confidence interval: 0.46-0.94). CONCLUSION: This systematic review and meta-analysis showed no significant differences in clinical outcomes between patients with concomitant significant CAD who were treated with TAVI with and without preceding PCI at both short- and long-term follow-up. However, there was a higher risk of major bleeding at 30 days in patients undergoing TAVI with preceding PCI. In the context of serious risk of bias in the included studies, results of randomised controlled trials are warranted.

3.
Circulation ; 144(2): 96-109, 2021 07 13.
Article in English | MEDLINE | ID: mdl-34011163

ABSTRACT

BACKGROUND: Ten-year all-cause death according to incomplete (IR) versus complete revascularization (CR) has not been fully investigated in patients with 3-vessel disease and left main coronary artery disease undergoing percutaneous coronary intervention (PCI) versus coronary artery bypass grafting (CABG). METHODS: The SYNTAX Extended Survival study (Synergy Between PCI With TAXUS and Cardiac Surgery: SYNTAX Extended Survival [SYNTAXES]) evaluated vital status up to 10 years in patients who were originally enrolled in the SYNTAX trial. In the present substudy, outcomes of the CABG CR group were compared with the CABG IR, PCI CR, and PCI IR groups. In addition, in the PCI cohort, the residual SYNTAX score (rSS) was used to quantify the extent of IR and to assess its association with fatal late outcome. The rSS of 0 suggests CR, whereas a rSS>0 identifies the degree of IR. RESULTS: IR was more frequently observed in patients with PCI versus CABG (56.6% versus 36.8%) and more common in those with 3-vessel disease than left main coronary artery disease in both the PCI arm (58.5% versus 53.8%) and the CABG arm (42.8% versus 27.5%). Patients undergoing PCI with CR had no significant difference in 10-year all-cause death compared with those undergoing CABG (22.2% for PCI with CR versus 24.3% for CABG with IR versus 23.8% for CABG with CR). In contrast, those with PCI and IR had a significantly higher risk of all-cause death at 10 years compared with CABG and CR (33.5% versus 23.7%; adjusted hazard ratio, 1.48 [95% CI, 1.15-1.91]). When patients with PCI were stratified according to the rSS, those with a rSS≤8 had no significant difference in all-cause death at 10 years as the other terciles (22.2% for rSS=0 versus 23.9% for rSS>0-4 versus 28.9% for rSS>4-8), whereas a rSS>8 had a significantly higher risk of 10-year all-cause death than those undergoing PCI with CR (50.1% versus 22.2%; adjusted hazard ratio, 3.40 [95% CI, 2.13-5.43]). CONCLUSIONS: IR is common after PCI, and the degree of incompleteness was associated with 10-year mortality. If it is unlikely that complete (or nearly complete; rSS<8) revascularization can be achieved with PCI in patients with 3-vessel disease, CABG should be considered. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00114972. URL: https://www.clinicaltrials.gov; Unique identifier: NCT03417050.


Subject(s)
Coronary Artery Disease/mortality , Percutaneous Coronary Intervention/methods , Vascular Diseases/mortality , Aged , Humans , Middle Aged , Percutaneous Coronary Intervention/mortality , Risk Factors , Time Factors , Treatment Outcome
4.
Circulation ; 143(22): 2143-2154, 2021 06.
Article in English | MEDLINE | ID: mdl-33820424

ABSTRACT

BACKGROUND: Accelerated endothelial healing after targeted antiproliferative drug delivery may limit the long-term inflammatory response of drug-eluting stents (DESs). The novel Supreme DES is designed to synchronize early drug delivery within 4 to 6 weeks of implantation, leaving behind a prohealing permanent base layer. Whether the Supreme DES is safe and effective in the short term and can improve long-term clinical outcomes is not known. METHODS: In an international, 2:1 randomized, single-blind trial, we compared treatment with Supreme DES to durable polymer everolimus-eluting stents (DP-EES) in patients with acute and chronic coronary syndromes. The primary end point was target lesion failure-a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The trial was designed to demonstrate noninferiority (margin of 3.58%) of the Supreme DES at 12 months compared with DP-EES (URL: https://www.clinicaltrials.gov; Unique identifier: NCT03168776). RESULTS: From October 2017 to July 2019, a total of 1629 patients were randomly assigned (2:1) to the Supreme DES (N=1086) or DP-EES (N=543). At 12 months, target lesion failure occurred in 57 of 1057 patients (5.4%) in the Supreme DES group and in 27 of 532 patients (5.1%) in the DP-EES group (absolute risk difference, 0.32% [95% CI, -1.87 to 2.5]; Pnoninferiority=0.002]. There were no significant differences in rates of device success, clinically driven target lesion revascularization, or stent thrombosis at 12 months, and the safety composite of cardiovascular death and target vessel myocardial infarction was 3.5% versus 4.6% (hazard ratio, 0.76 [95% CI, 0.46-1.25]) with Supreme DES compared with DP-EES, although rates of combined clinically and non-clinically driven target lesion revascularization at 12 months were higher with Supreme DES. CONCLUSIONS: Among patients with acute and chronic coronary syndromes undergoing percutaneous coronary intervention, the Supreme DES proved to be noninferior to the standard DP-EES. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03168776.


Subject(s)
Cell Proliferation/drug effects , Coronary Artery Disease/therapy , Drug Delivery Systems/methods , Drug-Eluting Stents/standards , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Treatment Outcome , Young Adult
5.
Am Heart J ; 246: 32-43, 2022 04.
Article in English | MEDLINE | ID: mdl-34990582

ABSTRACT

BACKGROUND: Current ESC guidelines recommend the use of intra-coronary pressure guidewires for functional assessment of intermediate-grade coronary stenoses. Angiography-derived quantitative flow ratio (QFR) is a novel method of assessing these stenoses, and guiding percutaneous coronary intervention (PCI). METHODS/DESIGN: The PIONEER IV trial is a prospective, all-comers, multi-center trial, which will randomize 2,540 patients in a 1:1 ratio to PCI guided by angiography-derived physiology or usual care, with unrestricted use in both arms of the Healing-Targeted Supreme sirolimus-eluting stent (HT Supreme). The stent's fast, biologically healthy, and robust endothelial coverage allows for short dual-antiplatelet therapy (DAPT); hence the antiplatelet regimen of choice is 1-month DAPT, followed by ticagrelor monotherapy. In the angiography-derived physiology guided arm, lesions will be functionally assessed using on-line QFR, with stenting indicated in lesions with a QFR ≤0.80. Post-stenting, QFR will be repeated in the stented vessel(s), with post-dilatation or additional stenting recommended if the QFR<0.91 distal to the stent, or if the delta QFR (across the stent) is >0.05. Usual care PCI is performed according to standard clinical practice. The primary endpoint is a non-inferiority comparison of the patient-oriented composite endpoint (POCE) of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization with a non-inferiority risk-difference margin of 3.2%, at 1-year post-procedure. Clinical follow-up will be up to 3 years. SUMMARY: The PIONEER IV trial aims to demonstrate non-inferiority of QFR-guided PCI to usual care PCI with respect to POCE at 1-year in patients treated with HT Supreme stents and ticagrelor monotherapy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov UNIQUE IDENTIFIER: NCT04923191 CLASSIFICATIONS: Interventional Cardiology.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Angiography , Coronary Artery Disease/therapy , Humans , Percutaneous Coronary Intervention/methods , Prospective Studies , Stents , Ticagrelor/therapeutic use , Treatment Outcome
6.
Catheter Cardiovasc Interv ; 100(1): 72-82, 2022 07.
Article in English | MEDLINE | ID: mdl-35500171

ABSTRACT

BACKGROUND: Several studies have suggested that proton pump inhibitors (PPIs) may reduce the antiplatelet effects of clopidogrel and/or aspirin, possibly leading to cardiovascular events. AIMS: We aimed to investigate the association between PPI and clinical outcomes in patients treated with ticagrelor monotherapy or conventional antiplatelet therapy after percutaneous coronary intervention (PCI). METHODS: This is a subanalysis of the randomized GLOBAL LEADERS trial, comparing the experimental antiplatelet arm (23-month ticagrelor monotherapy following 1-month dual antiplatelet therapy [DAPT]) with the reference arm (12-month aspirin monotherapy following 12-month DAPT) after PCI. Patient-oriented composite endpoints (POCEs: all-cause mortality, myocardial infarction, stroke, or repeat revascularization) and its components were assessed stratified by PPI use as a time-dependent covariate in patients with the experiment or reference antiplatelet arm. RESULTS: Among 15,839 patients, 2115 patients (13.5%) experienced POCE at 2 years. In the reference arm, the use of PPIs was independently associated with POCE (hazard ratio [HR]: 1.27; 95% confidence interval [CI]: 1.12-1.44) and its individual components, whereas it was not in the experimental arm (HR: 1.04; 95% CI: 0.92-1.19; pinteraction = 0.035). During the second-year follow-up, patients taking aspirin with PPIs had a significantly higher risk of POCE compared to those on aspirin without PPIs (HR: 1.57; 95% CI: 1.27-1.94), whereas the risk did not differ significantly irrespective of PPI in ticagrelor monotherapy group (HR: 1.03; 95% CI: 0.83-1.28; pinteraction = 0.008). CONCLUSIONS: In contrast to conventional antiplatelet strategy, there were no evidence suggesting the interaction between ticagrelor monotherapy and PPIs on increased cardiovascular events, which should be confirmed in further studies. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , Aspirin , Humans , Platelet Aggregation Inhibitors/adverse effects , Proton Pump Inhibitors , Ticagrelor , Treatment Outcome
7.
Am Heart J ; 239: 19-26, 2021 09.
Article in English | MEDLINE | ID: mdl-33992606

ABSTRACT

Angiography-derived physiological assessment of coronary lesions has emerged as an alternative to wire-based assessment aiming at less-invasiveness and shorter procedural time as well as cost effectiveness in physiology-guided decision making. However, current available image-derived physiology software have limitations including the requirement of multiple projections and are time consuming. METHODS/DESIGN: The ReVEAL iFR (Radiographic imaging Validation and EvALuation for Angio-iFR) trial is a multicenter, multicontinental, validation study which aims to validate the diagnostic accuracy of the Angio-iFR medical software device (Philips, San Diego, US) in patients undergoing angiography for Chronic Coronary Syndrome (CCS). The Angio-iFR will enable operators to predict both the iFR and FFR value within a few seconds from a single projection of cine angiography by using a lumped parameter fluid dynamics model. Approximately 440 patients with at least one de-novo 40% to 90% stenosis by visual angiographic assessment will be enrolled in the study. The primary endpoint is the sensitivity and specificity of the iFR and FFR for a given lesion compared to the corresponding invasive measures. The enrollment started in August 2019, and was completed in March 2021. SUMMARY: The Angio-iFR system has the potential of simplifying physiological evaluation of coronary stenosis compared with available systems, providing estimates of both FFR and iFR. The ReVEAL iFR study will investigate the predictive performance of the novel Angio-iFR software in CCS patients. Ultimately, based on its unique characteristics, the Angio-iFR system may contribute to improve adoption of functional coronary assessment and the workflow in the catheter laboratory.


Subject(s)
Coronary Angiography , Coronary Stenosis/diagnostic imaging , Coronary Vessels , Radiographic Image Interpretation, Computer-Assisted/methods , Software/standards , Coronary Angiography/methods , Coronary Angiography/trends , Coronary Artery Disease/diagnosis , Coronary Artery Disease/physiopathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Dimensional Measurement Accuracy , Humans , Outcome Assessment, Health Care , Predictive Value of Tests , Sensitivity and Specificity , Severity of Illness Index
8.
Catheter Cardiovasc Interv ; 98(4): 713-720, 2021 10.
Article in English | MEDLINE | ID: mdl-33118696

ABSTRACT

BACKGROUND: In this prespecified AIDA-trial sub-study we investigate the clinical performance of absorb bioresorbable vascular scaffold (BVS) compared to Xience everolimus-eluting stent (EES) in routine percutaneous coronary intervention (PCI) in patients with diabetes mellitus (DM) at complete 3-year follow-up. METHODS AND RESULTS: All 1,845 randomized patients were subdivided by medical history with DM or without DM. Of the 924 Absorb BVS patients, 171 (18.5%) patients had DM, of which 65 (38.0%) were treated with insulin (iTDM). Of the 921 Xience EES patients, 153 (16.6%) patients had DM, of which 45 (29.4%) were insulin-treated diabetes mellitus (iTDM). Target vessel failure (TVF), composite of cardiac death, target vessel myocardial infarction, and target vessel revascularization, occurred in 18.7% of diabetic patients treated with Absorb patients versus in 18.0% patients treated with Xience EES (p = .840). In nondiabetics the rates of TVF were 12.3% in Absorb BVS versus 11.0% in Xience EES (p = .391). Definite/probable device thrombosis occurred more frequently in Absorb BVS compared to Xience EES in both diabetic and nondiabetic patients (4.8% versus 0.7%; p = .028 and 3.2% vs. 0.5%; p < .001, respectively). CONCLUSIONS: In routine PCI practice, both Absorb BVS and Xience EES have worse clinical outcomes in diabetic patients as compared to nondiabetic patients. Throughout all clinical presentations, Absorb BVS was associated with higher rates of device thrombosis at 3-year follow-up.


Subject(s)
Cardiovascular Agents , Coronary Artery Disease , Diabetes Mellitus , Drug-Eluting Stents , Percutaneous Coronary Intervention , Absorbable Implants , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Diabetes Mellitus/diagnosis , Everolimus/adverse effects , Humans , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Risk Factors , Stents , Time Factors , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 97(7): E919-E928, 2021 06 01.
Article in English | MEDLINE | ID: mdl-33175478

ABSTRACT

OBJECTIVES: To compare the predictive performances of the prewiring, postwiring MI-SYNTAX scores, prewiring, and postwiring Updated Logistic Clinical SYNTAX score (LCSS) for 2-year all-cause mortality post percutaneous coronary intervention (PCI) in ST-elevation myocardial infarction (STEMI) patients. BACKGROUND: In patients with STEMI and undergoing primary PCI, coronary stenosis(es) distal to the culprit lesion is often observed after the restoration of coronary flow. To address comprehensively the complex coronary anatomy in these patients, prewiring and postwiring MI-SYNTAX scores have been reported in the literature. Furthermore, to enable individualized risk estimation for long-term all-cause mortality, the Updated LCSS has been developed by combining the anatomical SYNTAX score and clinical factors. METHODS: In the randomized GLOBAL LEADERS trial, anatomical SYNTAX score analysis was performed by an independent angiographic corelab for the first 4,000 consecutive patients as a prespecified analysis; of these, 545 presented with STEMI. The efficacy of the mortality predictions of the four scores at 2 years were evaluated based on their discrimination and calibration abilities. RESULTS: Complete data was available in 512 patients (93.9%). When the patients were stratified into two groups based on the median of the scores, the prewiring and postwiring Updated LCSSs demonstrated that the high-score groups were associated with higher rates of 2-year all-cause mortality compared to the low-score groups (6.6 vs. 1.2%; log-rank p = .001 and 6.6 vs. 1.2%; log-rank p = .001, respectively). There were no statistically significant differences for predicting the mortality between the prewiring (area under the curve [AUC] 0.625), postwiring MI-SYNTAX score (AUC 0.614), prewiring (AUC 0.755), and postwiring Updated LCSS (AUC 0.757). In the integrated discrimination improvement (IDI), the prewiring MI-SYNTAX score had a better discrimination for the mortality than the postwiring MI-SYNTAX score (IDI -0.0082; p = .029). The four scores had acceptable calibration abilities for 2-year all-cause mortality. CONCLUSIONS: The prewiring Updated LCSS predicts long-term all-cause mortality with clearly useful discrimination and acceptable calibration. Since the postwiring MI-SYNTAX score does not improve mortality prediction, the prewiring MI-SYNTAX score may be preferred for the 2-year mortality prediction using the Updated LCSS.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Coronary Angiography , Humans , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Risk Assessment , Risk Factors , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/surgery , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 98(7): 1287-1297, 2021 12 01.
Article in English | MEDLINE | ID: mdl-33539048

ABSTRACT

AIMS: We aimed to update the logistic clinical SYNTAX score to predict 2 year all-cause mortality after contemporary percutaneous coronary intervention (PCI). METHODS AND RESULTS: We analyzed 15,883 patients in the GLOBAL LEADERS study who underwent PCI. The logistic clinical SYNTAX model was updated after imputing missing values by refitting the original model (refitted original model) and fitting an extended new model (new model, with, selection based on the Akaike Information Criterion). External validation was performed in 10,100 patients having PCI at Fu Wai hospital. Chronic obstructive pulmonary disease, prior stroke, current smoker, hemoglobin level, and white blood cell count were identified as additional independent predictors of 2 year all-cause mortality and included into the new model. The c-indexes of the original, refitted original and the new model in the derivation cohort were 0.74 (95% CI 0.72-0.76), 0.75 (95% CI 0.73-0.77), and 0.78 (95% CI 0.76-0.80), respectively. The c-index of the new model was lower in the validation cohort than in the derivation cohort, but still showed improved discriminative ability of the newly developed model (0.72; 95% CI 0.67-0.77) compared to the refitted original model (0.69; 95% CI 0.64-0.74). The models overestimated the observed 2 year all-cause mortality of 1.11% in the Chinese external validation cohort by 0.54 percentage points, indicating the need for calibration of the model to the Chinese patient population. CONCLUSIONS: The new model of the logistic clinical SYNTAX score better predicts 2 year all-cause mortality after PCI than the original model. The new model could guide clinical decision making by risk stratifying patients undergoing PCI.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/surgery , Humans , Percutaneous Coronary Intervention/adverse effects , Predictive Value of Tests , Risk Assessment , Risk Factors , Treatment Outcome
11.
Lancet ; 394(10209): 1629-1637, 2019 11 02.
Article in English | MEDLINE | ID: mdl-31570255

ABSTRACT

BACKGROUND: Near-infrared spectroscopy (NIRS) intravascular ultrasound imaging can detect lipid-rich plaques (LRPs). LRPs are associated with acute coronary syndromes or myocardial infarction, which can result in revascularisation or cardiac death. In this study, we aimed to establish the relationship between LRPs detected by NIRS-intravascular ultrasound imaging at unstented sites and subsequent coronary events from new culprit lesions. METHODS: In this prospective, cohort study (LRP), patients from 44 medical centres were enrolled in Italy, Latvia, Netherlands, Slovakia, UK, and the USA. Patients with suspected coronary artery disease who underwent cardiac catheterisation with possible ad hoc percutaneous coronary intervention were eligible to be enrolled. Enrolled patients underwent scanning of non-culprit segments using NIRS-intravascular ultrasound imaging. The study had two hierarchal primary hypotheses, patient and plaque, each testing the association between maximum 4 mm Lipid Core Burden Index (maxLCBI4mm) and non-culprit major adverse cardiovascular events (NC-MACE). Enrolled patients with large LRPs (≥250 maxLCBI4mm) and a randomly selected half of patients with small LRPs (<250 maxLCBI4mm) were followed up for 24 months. This study is registered with ClinicalTrials.gov, NCT02033694. FINDINGS: Between Feb 21, 2014, and March 30, 2016, 1563 patients were enrolled. NIRS-intravascular ultrasound device-related events were seen in six (0·4%) patients. 1271 patients (mean age 64 years, SD 10, 883 [69%] men, 388 [31%]women) with analysable maxLCBI4mm were allocated to follow-up. The 2-year cumulative incidence of NC-MACE was 9% (n=103). Both hierarchical primary hypotheses were met. On a patient level, the unadjusted hazard ratio (HR) for NC-MACE was 1·21 (95% CI 1·09-1·35; p=0·0004) for each 100-unit increase maxLCBI4mm) and adjusted HR 1·18 (1·05-1·32; p=0·0043). In patients with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 2·18 (1·48-3·22; p<0·0001) and adjusted HR was 1·89 (1·26-2·83; p=0·0021). At the plaque level, the unadjusted HR was 1·45 (1·30-1·60; p<0·0001) for each 100-unit increase in maxLCBI4mm. For segments with a maxLCBI4mm more than 400, the unadjusted HR for NC-MACE was 4·22 (2·39-7·45; p<0·0001) and adjusted HR was 3·39 (1·85-6·20; p<0·0001). INTERPRETATION: NIRS imaging of non-obstructive territories in patients undergoing cardiac catheterisation and possible percutaneous coronary intervention was safe and can aid in identifying patients and segments at higher risk for subsequent NC-MACE. NIRS-intravascular ultrasound imaging adds to the armamentarium as the first diagnostic tool able to detect vulnerable patients and plaques in clinical practice. FUNDING: Infraredx.


Subject(s)
Acute Coronary Syndrome/etiology , Plaque, Atherosclerotic/diagnostic imaging , Spectroscopy, Near-Infrared/methods , Ultrasonography, Interventional/methods , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/surgery , Aged , Cardiac Catheterization/methods , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Death , Female , Humans , Italy/epidemiology , Latvia/epidemiology , Male , Middle Aged , Myocardial Infarction/diagnosis , Myocardial Infarction/etiology , Myocardial Infarction/surgery , Netherlands/epidemiology , Percutaneous Coronary Intervention/methods , Plaque, Atherosclerotic/complications , Plaque, Atherosclerotic/pathology , Slovakia/epidemiology , United Kingdom/epidemiology , United States/epidemiology
12.
N Engl J Med ; 376(24): 2319-2328, 2017 06 15.
Article in English | MEDLINE | ID: mdl-28402237

ABSTRACT

BACKGROUND: Bioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice. METHODS: We randomly assigned 1845 patients undergoing PCI to receive either a bioresorbable vascular scaffold (924 patients) or a metallic stent (921 patients). The primary end point was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization). The data and safety monitoring board recommended early reporting of the study results because of safety concerns. This report provides descriptive information on end-point events. RESULTS: The median follow-up was 707 days. Target-vessel failure occurred in 105 patients in the scaffold group and in 94 patients in the stent group (2-year cumulative event rates, 11.7% and 10.7%, respectively; hazard ratio, 1.12; 95% confidence interval [CI], 0.85 to 1.48; P=0.43); event rates were based on Kaplan-Meier estimates in time-to-event analyses. Cardiac death occurred in 18 patients in the scaffold group and in 23 patients in the stent group (2-year cumulative event rates, 2.0% and 2.7%, respectively), target-vessel myocardial infarction occurred in 48 patients in the scaffold group and in 30 patients in the stent group (2-year cumulative event rates, 5.5% and 3.2%), and target-vessel revascularization occurred in 76 patients in the scaffold group and in 65 patients in the stent group (2-year cumulative event rates, 8.7% and 7.5%). Definite or probable device thrombosis occurred in 31 patients in the scaffold group as compared with 8 patients in the stent group (2-year cumulative event rates, 3.5% vs. 0.9%; hazard ratio, 3.87; 95% CI, 1.78 to 8.42; P<0.001). CONCLUSIONS: In this preliminary report of a trial involving patients undergoing PCI, there was no significant difference in the rate of target-vessel failure between the patients who received a bioresorbable scaffold and the patients who received a metallic stent. The bioresorbable scaffold was associated with a higher incidence of device thrombosis than the metallic stent through 2 years of follow-up. (Funded by Abbott Vascular; AIDA ClinicalTrials.gov number, NCT01858077 .).


Subject(s)
Absorbable Implants , Coronary Stenosis/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention , Self Expandable Metallic Stents , Absorbable Implants/adverse effects , Aged , Everolimus/administration & dosage , Female , Follow-Up Studies , Heart Diseases/mortality , Humans , Incidence , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Self Expandable Metallic Stents/adverse effects , Thrombosis/epidemiology , Thrombosis/etiology , Treatment Outcome
13.
Catheter Cardiovasc Interv ; 95(1): 89-96, 2020 01.
Article in English | MEDLINE | ID: mdl-30968559

ABSTRACT

BACKGROUND: Patients with acute coronary syndrome (ACS) might represent a specific subgroup, in which bioresorbable scaffold implantation in percutaneous coronary intervention (PCI), might lead to better outcomes when compared to conventional treatment with metallic drug eluting stents. In this prespecified subgroup analysis of the Amsterdam Investigator-Initiated Absorb Strategy All-Comers (AIDA) trial, we evaluated the clinical outcomes of Absorb bioresorbable vascular scaffold (BVS) versus Xience everolimus eluting stent (EES) treated patients presenting either with or without ACS. METHODS AND RESULTS: We classified AIDA patients on the basis of clinical presentation of ACS or of no-ACS. The rate of the 2-year primary endpoint of target vessel failure (TVF) was similar after treatment with Absorb BVS or Xience EES in ACS patients (10.2% versus 9.0% respectively; P = 0.49) and in no-ACS patients (11.7% versus 10.7%, respectively; P = 0.67) Definite or probable device thrombosis occurred more frequently with Absorb BVS compared to Xience EES in ACS patients (4.3% versus 1.7%, respectively, P = 0.03) as well as in no-ACS patients (2.4% versus 0.2%, respectively; P = 0.002). There were no statistically significant interactions between clinical presentation and randomized device modality for TVF (P = 0.80) and for the endpoint of definite or probable device thrombosis (P = 0.17). CONCLUSION: In the AIDA trial, the 2-year outcomes of PCI with Absorb BVS versus Xience EES were consistent in ACS and no-ACS patients: similar rates for TVF and consistently higher rates of definite or probable stent thrombosis under Absorb BVS versus Xience EES. There were no statistically significant interactions between clinical presentation and randomized device modality.


Subject(s)
Absorbable Implants , Acute Coronary Syndrome/therapy , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Metals , Percutaneous Coronary Intervention/instrumentation , Acute Coronary Syndrome/diagnostic imaging , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Thrombosis/etiology , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Netherlands , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Risk Factors , Single-Blind Method , Time Factors , Treatment Outcome
14.
Eur Heart J ; 40(31): 2595-2604, 2019 08 14.
Article in English | MEDLINE | ID: mdl-31397487

ABSTRACT

AIMS: To evaluate the impact of an experimental strategy [23-month ticagrelor monotherapy following 1-month dual antiplatelet therapy (DAPT)] vs. a reference regimen (12-month aspirin monotherapy following 12-month DAPT) after complex percutaneous coronary intervention (PCI). METHODS AND RESULTS: In the present post hoc analysis of the Global Leaders trial, the primary endpoint [composite of all-cause death or new Q-wave myocardial infarction (MI)] at 2 years was assessed in patients with complex PCI, which includes at least one of the following characteristics: multivessel PCI, ≥3 stents implanted, ≥3 lesions treated, bifurcation PCI with ≥2 stents, or total stent length >60 mm. In addition, patient-oriented composite endpoint (POCE) (composite of all-cause death, any stroke, any MI, or any revascularization) and net adverse clinical events (NACE) [composite of POCE or Bleeding Academic Research Consortium (BARC) Type 3 or 5 bleeding] were explored. Among 15 450 patients included in this analysis, 4570 who underwent complex PCI had a higher risk of ischaemic and bleeding events. In patients with complex PCI, the experimental strategy significantly reduced risks of the primary endpoint [hazard ratio (HR): 0.64, 95% confidence interval (CI): 0.48-0.85] and POCE (HR: 0.80, 95% CI: 0.69-0.93), but not in those with non-complex PCI (Pinteraction = 0.015 and 0.017, respectively). The risk of BARC Type 3 or 5 bleeding was comparable (HR: 0.97, 95% CI: 0.67-1.40), resulting in a significant risk reduction in NACE (HR: 0.80, 95% CI: 0.69-0.92; Pinteraction = 0.011). CONCLUSION: Ticagrelor monotherapy following 1-month DAPT could provide a net clinical benefit for patients with complex PCI. However, in view of the overall neutral results of the trial, these findings of a post hoc analysis should be considered as hypothesis generating.


Subject(s)
Acute Coronary Syndrome/therapy , Myocardial Infarction/mortality , Percutaneous Coronary Intervention/methods , Purinergic P2Y Receptor Antagonists/therapeutic use , Ticagrelor/therapeutic use , Aged , Aspirin/adverse effects , Aspirin/therapeutic use , Case-Control Studies , Cause of Death/trends , Drug Therapy, Combination , Drug-Eluting Stents/adverse effects , Female , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Humans , Male , Middle Aged , Myocardial Infarction/physiopathology , Myocardial Infarction/therapy , Myocardial Revascularization/adverse effects , Myocardial Revascularization/methods , Platelet Aggregation Inhibitors/adverse effects , Platelet Aggregation Inhibitors/therapeutic use , Prospective Studies , Purinergic P2Y Receptor Antagonists/adverse effects , Stroke/chemically induced , Stroke/epidemiology , Stroke/mortality , Ticagrelor/adverse effects
15.
Catheter Cardiovasc Interv ; 93(4): E248-E254, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30208263

ABSTRACT

OBJECTIVES: The aim of this study was to assess the predictive value of PMA measurement for mortality. BACKGROUND: Current surgical risk stratification have limited predictive value in the transcatheter aortic valve implantation (TAVI) population. In TAVI workup, a CT scan is routinely performed but body composition is not analyzed. Psoas muscle area (PMA) reflects a patient's global muscle mass and accordingly PMA might serve as a quantifiable frailty measure. METHODS: Multi-slice computed tomography scans (between 2010 and 2016) of 583 consecutive TAVI patients were reviewed. Patients were divided into equal sex-specific tertiles (low, mid, and high) according to an indexed PMA. Hazard ratios (HR) and their confidence intervals (CI) were determined for cardiac and all-cause mortality after TAVI. RESULTS: Low iPMA was associated with cardiac and all-cause mortality in females. One-year adjusted cardiac mortality HR in females for mid-iPMA and high-iPMA were 0.14 [95%CI, 0.05-0.45] and 0.40 [95%CI, 0.15-0.97], respectively. Similar effects were observed for 30-day and 2-years cardiac and all-cause mortality. In females, adding iPMA to surgical risk scores improved the predictive value for 1-year mortality. C-statistics changed from 0.63 [CI = 0.54-0.73] to 0.67 [CI: 0.58-0.75] for EuroSCORE II and from 0.67 [CI: 0.59-0.77] to 0.72 [CI: 0.63-0.80] for STS-PROM. CONCLUSIONS: Particularly in females, low iPMA is independently associated with an higher all-cause and cardiac mortality. Prospective studies should confirm whether PMA or other body composition parameters should be extracted automatically from CT-scans to include in clinical decision making and outcome prediction for TAVI.


Subject(s)
Aortic Valve Stenosis/surgery , Body Composition , Frailty/diagnostic imaging , Multidetector Computed Tomography , Psoas Muscles/diagnostic imaging , Sarcopenia/diagnostic imaging , Transcatheter Aortic Valve Replacement/mortality , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/physiopathology , Female , Frailty/mortality , Frailty/physiopathology , Health Status , Humans , Male , Predictive Value of Tests , Psoas Muscles/physiopathology , Retrospective Studies , Risk Assessment , Risk Factors , Sarcopenia/mortality , Sarcopenia/physiopathology , Sex Factors , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
16.
Catheter Cardiovasc Interv ; 93(4): E225-E234, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30702187

ABSTRACT

OBJECTIVES: To investigate the impact of minimal stent area (MSA) evaluated by post-procedural intravascular ultrasound (IVUS) on clinical outcomes after contemporary PCI in patients with three-vessel disease (TVD). BACKGROUND: The impact of post-procedural MSA on clinical outcomes has not yet been extensively studied in patients with TVD. METHODS: The SYNTAX II study is a multicenter, all-comers, open-label, single arm study that investigated the impact of a state-of-the-art PCI strategy on clinical outcomes in patients with TVD (454 patients with 1,559 lesions). The relationships between post-procedural MSA and lesion-level outcomes at 2 years were investigated. Clinical events adjudicated per patient by clinical event committee were assessed per lesion. Lesion-oriented composite endpoint (LOCE) was defined as the composite of cardiac death, target-vessel myocardial infarction, and ischemia-driven target lesion revascularization. RESULTS: Eight hundred and nineteen lesions with post-procedural MSA available in 367 patients were included in the analysis. The post-procedural MSA per lesion was divided into terciles (smallest tercile: ≤5.0 mm2 , intermediate tercile: 5.0-6.7 mm2 , and largest tercile: >6.7 mm2 ). LOCE was observed in 16/288 (5.6%), 15/265 (5.7%), and 8/266 (3.0%) (P = 0.266). Target lesion revascularization (TLR) was observed in 16/288(5.6%), 12/265 (4.5%), and 4/266 (1.5%) (P = 0.042). The multivariate analysis demonstrated that smaller post-procedural MSA, as well as creatinine clearance, history of previous stroke, chronic total occlusion, and lesion SYNTAX Score was an independent predictor of TLR. CONCLUSIONS: In the SYNTAX II trial, larger post-procedural MSA was independently associated with the lower rate of TLR at 2 years.


Subject(s)
Coronary Artery Disease/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Aged , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Europe , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Risk Assessment , Risk Factors , Time Factors , Treatment Outcome , Ultrasonography, Interventional
17.
Circ J ; 83(3): 556-566, 2019 02 25.
Article in English | MEDLINE | ID: mdl-30700665

ABSTRACT

BACKGROUND: Little is known about serial changes in lumen and device dimensions after bioresorbable scaffold implantation in a growing animal model. Methods and Results: ABSORB (n=14) or bare metal stents (ICROS amg [Abbott Vascular, Santa Clara, CA, USA], Winsen-Luhe, Germany; n=15) were implanted in the coronary arteries of domestic swine (a hybrid of Finnish-Norwegian Landrace swine) weighing 30-35 kg. Angiography and optical coherence tomography (OCT) were performed immediately after implantation and repeated at 7 days, 1, 3, 6 and 12 months after the index procedure. One month after implantation, mean lumen area decreased relative to baseline in both groups (relative area change from baseline, -41.4±15.6% for ABSORB vs. -20.9±18.6% for ICROS) while mean device area decreased only in the ABSORB group (relative area change: -11.1±9.4% vs. +0.14±7.95%, respectively). At 12 months, mean lumen area increased relative to baseline in both groups (relative area change from baseline, +55.6±22.4% vs. +32.3±83.6%, respectively) in accordance with the swine growth weighing up to 260-300 kg. Mean device area in the ICROS group remained stable whereas that in the ABSORB group began to increase between 3 and 6 months along with the vessel growth (relative area change: +107.8±25.7% vs. +0.14±7.95%). CONCLUSIONS: In the growing porcine model, ABSORB was associated with greater extent of recoil 1 month after implantation compared with ICROS but demonstrated substantial adaptability to vessel growth in late phase.


Subject(s)
Absorbable Implants/standards , Coronary Vessels/diagnostic imaging , Stents/standards , Tomography, Optical Coherence/methods , Animals , Coronary Angiography/methods , Coronary Vessels/growth & development , Coronary Vessels/surgery , Models, Animal , Prosthesis Design/standards , Swine , Time Factors
18.
Eur Heart J ; 39(36): 3381-3389, 2018 09 21.
Article in English | MEDLINE | ID: mdl-30124834

ABSTRACT

Aim: In current device trials, the values of angiographic late lumen loss (LLL) have become extremely low and the relationship between LLL and clinical endpoints has not been recently re-evaluated. The impact of LLL on target lesion revascularization (TLR) in a patient- and study-level analysis of contemporary coronary devices was investigated. Methods and results: We performed a patient-level meta-analysis of seven randomized controlled trials including 2426 patients treated with first- and second-generation drug-eluting stents (DES) and a study-level meta-analysis of 40 studies including 19 199 patients treated with CE-marked DES. In the patient-level analysis, the probability regression curve showed an exponential relationship between in-stent LLL and 2-year incidence of TLR. The optimal cut-off value of LLL based on Youden's index for 2-year TLR event was 0.50 mm. In the Cox proportional hazard model, LLL >0.50 mm was independently associated with an increased incidence of TLR up to 4 years after angiographic follow-up {adjusted hazard ratio (HR) 6.62 [95% confidence interval (95% CI) 4.67-9.39], P < 0.001}. In the meta-regression analysis of the DES studies, pooled mean value of LLL was as low as 0.23 mm (95% CI 0.20-0.26), and there was a moderate correlation between the 1- and 5-year incidence of TLR and the percentage of the lesions with LLL >0.50 mm (R2 = 0.44, P < 0.001 at 1 year, R2 = 0.40, P < 0.001 at 5 years). Conclusion: An angiographic LLL ≤0.50 mm was not predictive of the incidence of TLR whereas a LLL >0.50 mm was. Low LLL in contemporary device trials may not be a sufficiently discriminating parameter for the comparative evaluation of devices.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Drug-Eluting Stents , Myocardial Revascularization/methods , Coronary Angiography , Coronary Artery Disease/pathology , Humans
19.
Catheter Cardiovasc Interv ; 92(5): 897-906, 2018 11 01.
Article in English | MEDLINE | ID: mdl-29516609

ABSTRACT

OBJECTIVES: To evaluate the occurrence of rewiring through one of the panels of the Tryton stent (instead of the assumed re-wiring in-between the panels) and the influence on stent geometry and mechanics. BACKGROUND: Tryton is a side branch stent used in combination with a main branch device. It is placed without the need of rotational orientation. However, it is unknown whether main branch re-wiring accidentally may occur through a panel, instead of in-between the panels. METHODS: We used three-dimensional optical coherence tomography to evaluate the location of distal main branch re-wiring through Tryton. Furthermore, we used computer simulations to evaluate the influence on stent geometry and mechanics. RESULTS: Rewiring through a panel (instead of in-between two panels) occurred in 45% of the cases. By using virtual stent deployment, we found minimal differences in ostial side branch stenoses (44.8% in-between the panels and 39.0% through a panel). There were no differences in minimum stent areas of the distal main branch (6.38 mm2 vs. 6.39 mm2 ). In both scenarios, the re-wired Tryton cell was large enough for main branch stenting (expressed as the diameter of the largest possible circle that fits within the cells): 3.40 mm (in-between the panels) vs. 3.02 mm (through a panel). CONCLUSIONS: In 45% of the Tryton implantations, distal main branch rewiring (and subsequent main branch stenting) was performed through one Tryton panel, instead of the assumed rewiring in-between the panels. However, this did not result in unfavorable stent geometries or mechanics, as evaluated with computer simulations.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/therapy , Models, Cardiovascular , Patient-Specific Modeling , Stents , Tomography, Optical Coherence , Angioplasty, Balloon, Coronary/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/physiopathology , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prosthesis Design , Registries , Treatment Outcome
20.
Catheter Cardiovasc Interv ; 91(7): 1263-1270, 2018 06.
Article in English | MEDLINE | ID: mdl-28836339

ABSTRACT

OBJECTIVES: To compare visual estimation with different quantitative coronary angiography (QCA) methods (single-vessel versus bifurcation software) to assess coronary bifurcation lesions. BACKGROUND: QCA has been developed to overcome the limitations of visual estimation. Conventional QCA however, developed in "straight vessels," has proved to be inaccurate in bifurcation lesions. Therefore, bifurcation QCA was developed. However, the impact of these different modalities on bifurcation lesion severity classification is yet unknown METHODS: From a randomized controlled trial investigating a novel bifurcation stent (Clinicaltrials.gov NCT01258972), patients with baseline assessment of lesion severity by means of visual estimation, single-vessel QCA, 2D bifurcation QCA and 3D bifurcation QCA were included. We included 113 bifurcations lesions in which all 5 modalities were assessed. The primary end-point was to evaluate how the different modalities affected the classification of bifurcation lesion severity and extent of disease. RESULTS: On visual estimation, 100% of lesions had side-branch diameter stenosis (%DS) >50%, whereas in 83% with single-vessel QCA, 27% with 2D bifurcation QCA and 26% with 3D bifurcation QCA a side-branch %DS >50% was found (P < 0.0001). With regard to the percentage of "true" bifurcation lesions, there was a significant difference between visual estimate (100%), single-vessel QCA (75%) and bifurcation QCA (17% with 2D bifurcation software and 13% with 3D bifurcation software, P < 0.0001). CONCLUSIONS: Our study showed that bifurcation lesion complexity was significantly affected when more advanced bifurcation QCA software were used. "True" bifurcation lesion rate was 100% on visual estimation, but as low as 13% when analyzed with dedicated bifurcation QCA software.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Visual Perception , Humans , Judgment , Predictive Value of Tests , Prognosis , Reproducibility of Results , Severity of Illness Index , Software
SELECTION OF CITATIONS
SEARCH DETAIL