Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
J Synchrotron Radiat ; 29(Pt 1): 239-246, 2022 Jan 01.
Article in English | MEDLINE | ID: mdl-34985441

ABSTRACT

Rodents are used extensively as animal models for the preclinical investigation of microvascular-related diseases. However, motion artifacts in currently available imaging methods preclude real-time observation of microvessels in vivo. In this paper, a pixel temporal averaging (PTA) method that enables real-time imaging of microvessels in the mouse brain in vivo is described. Experiments using live mice demonstrated that PTA efficiently eliminated motion artifacts and random noise, resulting in significant improvements in contrast-to-noise ratio. The time needed for image reconstruction using PTA with a normal computer was 250 ms, highlighting the capability of the PTA method for real-time angiography. In addition, experiments with less than one-quarter of photon flux in conventional angiography verified that motion artifacts and random noise were suppressed and microvessels were successfully identified using PTA, whereas conventional temporal subtraction and averaging methods were ineffective. Experiments performed with an X-ray tube verified that the PTA method could also be successfully applied to microvessel imaging of the mouse brain using a laboratory X-ray source. In conclusion, the proposed PTA method may facilitate the real-time investigation of cerebral microvascular-related diseases using small animal models.


Subject(s)
Artifacts , Image Processing, Computer-Assisted , Animals , Mice , Microvessels/diagnostic imaging , Radiography , X-Rays
2.
J Synchrotron Radiat ; 26(Pt 5): 1631-1637, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31490153

ABSTRACT

Indirect X-ray imaging detectors consisting of scintillator screens, long-working-distance microscope lenses and scientific high-speed complementary metal-oxide semiconductor (CMOS) cameras are usually used to realize fast X-ray imaging with white-beam synchrotron radiation. However, the detector efficiency is limited by the coupling efficiency of the long-working-distance microscope lenses, which is only about 5%. A long-working-distance microscope lenses system with a large numerical aperture (NA) is designed to increase the coupling efficiency. It offers an NA of 0.5 at 8× magnification. The Mitutoyo long-working-distance microscope lenses system offers an NA of 0.21 at 7.5× magnification. Compared with the Mitutoyo system, the developed long-working-distance microscope lenses system offers about twice the NA and four times the coupling efficiency. In the indirect X-ray imaging detector, a 50 µm-thick LuAG:Ce scintillator matching with the NA, and a high-speed visible-light CMOS FastCAM SAZ Photron camera are used. Test results show that the detector realized fast X-ray imaging with a frame rate of 100000 frames s-1 and fast X-ray microtomography with a temporal sampling rate up to 25 Hz (25 tomograms s-1).

3.
Appl Opt ; 56(30): 8326-8334, 2017 Oct 20.
Article in English | MEDLINE | ID: mdl-29091609

ABSTRACT

Small-angle x-ray scattering computed tomography (SAXS-CT) is a nondestructive method for the nanostructure analysis of heterogeneous materials. However, the limits of a long data acquisition time and vast amounts of data prevent SAXS-CT from becoming a routine experimental method in the applications of synchrotron radiation. In this study, the ordered subsets expectation maximization (OSEM) algorithm is introduced to improve the efficiency of SAXS-CT. To demonstrate the practicability of this method, a systematic simulation and experiments were carried out. The simulation results on a numerical phantom show that the OSEM-based SAXS-CT can effectively eliminate streaking artifacts and improve the efficiency of data acquisition by at least 3 times compared with the filter backprojection algorithm. By compromising the reconstruction speed and image quality, the optimal reconstruction parameters are also given for the image reconstruction in the OSEM-based SAXS-CT experiments. An experiment on a bamboo sample verified the validity of the proposed method with limited projection data. A further experiment on polyethylene demonstrated that the OSEM-based SAXS-CT is able to reveal the local nanoscale information about the crystalline structure and distributional difference inside the sample. In conclusion, the OSEM-based SAXS-CT can significantly improve experimental efficiency, which may promote SAXS-CT becoming a conventional method.

4.
J Xray Sci Technol ; 25(6): 1007-1017, 2017.
Article in English | MEDLINE | ID: mdl-28777770

ABSTRACT

Monochromatic-beam-based dynamic X-ray computed microtomography (CT) was developed to observe evolution of microstructure inside samples. However, the low flux density results in low efficiency in data collection. To increase efficiency, reducing the number of projections should be a practical solution. However, it has disadvantages of low image reconstruction quality using the traditional filtered back projection (FBP) algorithm. In this study, an iterative reconstruction method using an ordered subset expectation maximization-total variation (OSEM-TV) algorithm was employed to address and solve this problem. The simulated results demonstrated that normalized mean square error of the image slices reconstructed by the OSEM-TV algorithm was about 1/4 of that by FBP. Experimental results also demonstrated that the density resolution of OSEM-TV was high enough to resolve different materials with the number of projections less than 100. As a result, with the introduction of OSEM-TV, the monochromatic-beam-based dynamic X-ray microtomography is potentially practicable for the quantitative and non-destructive analysis to the evolution of microstructure with acceptable efficiency in data collection and reconstructed image quality.


Subject(s)
Algorithms , Image Processing, Computer-Assisted/methods , X-Ray Microtomography/methods , Animals , Gryllidae , Hand/diagnostic imaging , Head/diagnostic imaging , Humans , Models, Animal , Phantoms, Imaging
5.
Phys Rev Lett ; 117(11): 113901, 2016 Sep 09.
Article in English | MEDLINE | ID: mdl-27661686

ABSTRACT

Knowledge gained through x-ray crystallography fostered structural determination of materials and greatly facilitated the development of modern science and technology in the past century. However, it is only applied to crystalline structures and cannot resolve noncrystalline materials. Here we demonstrate a novel lensless Fourier-transform ghost imaging method with pseudothermal hard x rays that extends x-ray crystallography to noncrystalline samples. By measuring the second-order intensity correlation function of the light, Fourier-transform diffraction pattern of a complex amplitude sample is achieved at the Fresnel region in our experiment and the amplitude and phase distributions of the sample in the spatial domain are retrieved successfully. For the first time, ghost imaging is experimentally realized with x rays. Since a highly coherent x-ray source is not required, the method can be implemented with laboratory x-ray sources and it also provides a potential solution for lensless diffraction imaging with fermions, such as neutrons and electrons where intensive coherent sources usually are not available.

6.
J Xray Sci Technol ; 24(1): 79-86, 2016.
Article in English | MEDLINE | ID: mdl-26890902

ABSTRACT

BACKGROUND: The outstanding functional importance of the brain implies a strong need for brain imaging modalities. However, the current imaging approaches that target the brain in rodents remain suboptimal. OBJECTIVE AND METHODS: In this paper, X-ray propagation-based phase contrast imaging combined with equally sloped tomography (PPCI-EST) was employed to nondestructively investigate the mouse brain. RESULTS: The grey and white matters, which have extremely small differences in electron density, were clearly discriminated. The fine structures, including the corpus callosum (cc), the optic chiasma (ox) and the caudate putamen (CPu), were revealed. Compared to the filtered back projection reconstruction, the PPCI-EST significantly reduce projection number while maintaining sufficient image quality. CONCLUSIONS: It could be a potential tool for fast and low-dose phase-contrast imaging to biomedical specimens.


Subject(s)
Brain/diagnostic imaging , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Animals , Mice , Signal-To-Noise Ratio
7.
Analyst ; 140(10): 3521-5, 2015 May 21.
Article in English | MEDLINE | ID: mdl-25834844

ABSTRACT

X-ray fluorescence computed tomography (XFCT) is a stimulated emission tomography modality that maps the three-dimensional (3D) distribution of elements. Generally, XFCT is done by scanning a pencil-beam across the sample. This paper presents a feasibility study of full-field XFCT (FF-XFCT) for 3D elemental imaging. The FF-XFCT consists of a pinhole collimator and X-ray imaging detector with no energy resolution. A prototype imaging system was set up at the Shanghai Synchrotron Radiation Facility (SSRF) for imaging the phantom. The first FF-XFCT experimental results are presented. The cadmium (Cd) and iodine (I) distributions were reconstructed. The results demonstrate FF-XFCT is fit for 3D elemental imaging and the sensitivity of FF-XFCT is higher than a conventional CT system.

8.
IUCrJ ; 11(Pt 1): 73-81, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38096037

ABSTRACT

Speckle-tracking X-ray imaging is an attractive candidate for dynamic X-ray imaging owing to its flexible setup and simultaneous yields of phase, transmission and scattering images. However, traditional speckle-tracking imaging methods suffer from phase distortion at locations with abrupt changes in density, which is always the case for real samples, limiting the applications of the speckle-tracking X-ray imaging method. In this paper, we report a deep-learning based method which can achieve dynamic X-ray speckle-tracking imaging with high-accuracy phase retrieval. The calibration results of a phantom show that the profile of the retrieved phase is highly consistent with the theoretical one. Experiments of polyurethane foaming demonstrated that the proposed method revealed the evolution of the complicated microstructure of the bubbles accurately. The proposed method is a promising solution for dynamic X-ray imaging with high-accuracy phase retrieval, and has extensive applications in metrology and quantitative analysis of dynamics in material science, physics, chemistry and biomedicine.

9.
Rev Sci Instrum ; 95(7)2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38984889

ABSTRACT

Counter-gravity casting (CGC) aims to eliminate turbulent melt flow and defect formation during filling and subsequent solidification by pushing high-temperature melt into the mold cavity against gravity with regulated pressure. However, limited by the opaqueness of molten metals and the complexity of the CGC apparatus, it is extremely difficult to directly quantify the high-velocity mold filling and pressurized solidification in real-time. Here, we report the design and characterization of a CGC system capable of in situ monitoring of mold filling and subsequent solidification processes in the synchrotron beamlines by deploying a high-energy, high-speed synchrotron x-ray imaging technique. The high-velocity melt flow and dendrite growth during pressurized solidification have been quantified for systematical process parameter analysis by investigating time-resolved x-ray images of an exemplary Al-Cu alloy. The high-speed imaging results demonstrate that the in situ CGC system provides a useful way to better understand the fundamentals of mold filling, pressurized solidification, and experimental inputs for high-fidelity modeling in scientific and industrial applications.

10.
Guang Pu Xue Yu Guang Pu Fen Xi ; 33(3): 829-33, 2013 Mar.
Article in Zh | MEDLINE | ID: mdl-23705464

ABSTRACT

Third-generation synchrotron radiation X-ray phase-contrast microscopy(XPCM)can be used for obtaining image with edge enhancement, and achieve the high contrast imaging of low-Z materials with the spatial coherence peculiarity of X-rays. In the present paper, the characteristic microstructures of adhesive at the interface and their penetration in wood/bamboo composite material were investigated systematically by XPCM at Shanghai Synchrotron Radiation Facility (SSRF). And the effect of several processing techniques was analyzed for the adhesive penetration in wood/bamboo materials. The results show that the synchrotron radiation XPCM is expected to be one of the important precision detection methods for wood-based panels.


Subject(s)
Microscopy, Phase-Contrast/methods , Sasa/ultrastructure , Tomography, X-Ray Computed/methods , Wood/ultrastructure , Adhesives , Manufactured Materials , Radiographic Image Enhancement , Synchrotrons
11.
Chin Opt Lett ; 10(12): 121101, 2012 Dec 10.
Article in English | MEDLINE | ID: mdl-23833569

ABSTRACT

X-ray tomography of samples containing both weakly and strongly absorbing materials are necessary in material and biomedical imaging. Extending the validity of the phase-attenuation duality (PAD) method, the propagation-based phase-contrast computed tomography (PPCT) of a sample with hybrid compositions of both the light and dense components with 60 keV of synchrotron radiation is investigated. The experimental results show that the PAD-based PPCT is effective in imaging both the weakly and strongly absorbing components simultaneously. Compared with the direct PPCT technique, the PAD-based PPCT technique demonstrates its excellent capability in material discrimination and characterization. In addition, the PAD-based PPCT exhibits a striking performance on the image contrast enhancement and noise suppression. Therefore, this technique is useful for material and biomedical imaging applications, especially when the radiation dose involved imposes a serious constraint.

12.
Zhonghua Yi Xue Za Zhi ; 92(11): 778-82, 2012 Mar 20.
Article in Zh | MEDLINE | ID: mdl-22781361

ABSTRACT

OBJECTIVE: To detect deep-level microvascular structure in rat hind limb by synchrotron radiation and microangiographic technique. METHODS: Microangiography in vivo and ex vivo was performed by synchrotron radiation based absorption imaging and phase contrast imaging, with omnipaque and barium sulfate solution as contrast media, respectively, and synchrotron radiation-based micro-computed tomography (SRmCT) was also performed to reveal three-dimensional morphology of the blood vessel in rat hind limb. RESULTS: Using microangiographic technique in vivo and in vitro (with barium sulfate), blood vessels in the rat limb muscle could be visualized with high resolution, and the fourth branches of iliac artery in rat hind limb could be detected with the minimum visualized blood vessels about 40 µm and 9 µm in diameter, respectively. In addition, the vascular network could be defined and analyzed at the micrometer scale from the 3D renderings of limb vessel as shown by SRmCT. CONCLUSION: Synchrotron radiation-based microangiography and SRmCT thus provided a practical and effective means to observe the microvasculature of rat hindlimb, which might be useful in assessment of angiogenesis in lower limbs.


Subject(s)
Hindlimb/blood supply , Hindlimb/diagnostic imaging , Microvessels/diagnostic imaging , Angiography/methods , Animals , Male , Microcirculation , Rats , Rats, Inbred F344 , Synchrotrons , Tomography, X-Ray Computed/methods
13.
ACS Appl Mater Interfaces ; 14(33): 38196-38204, 2022 Aug 24.
Article in English | MEDLINE | ID: mdl-35951545

ABSTRACT

Soft devices, especially capacitive stress (or strain) sensors, are important for applications, including wearable medical monitoring, electronic skin, and soft robotics. The incorporation of liquid metal particles (LMPs) into highly deformable elastomers as inclusions ameliorates the mechanical compliance caused by a rigid filler. The high dielectric constant and liquid feature of LMPs are suitable for soft sensors with high sensitivity and a large real-time dynamic detection range. Here, a class of LM-elastomer composites are introduced with elastic and high dielectric properties, making them uniquely suitable for the application of soft stress sensors. The prepared stretchable soft stress sensor can detect the bending degree of the finger, monitor physiological signals in real time, and distinguish the vibration from the pronunciation of different letters. The nanoscale X-ray computational tomography (nano-CT) measurements indeed detect the changes of LMPs under stress, i.e., LMPs in the matrix distribute from uneven to relatively uniform, agglomerate, and even connect each other to have a conduction path in the composition with high LMP contents, which cause the changes in the physical properties of devices under operation. The cognition of LMP changes in composites under stress is instructive for promoting their further applications in the field of soft devices.


Subject(s)
Elastomers , Wearable Electronic Devices , Electronics , Metals , Monitoring, Physiologic
14.
J Surg Res ; 164(1): e193-9, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20828725

ABSTRACT

BACKGROUND: New X-ray microangiography and third-generation synchrotron radiation-based micro-computed tomography have opened new perspectives for microvascular imaging of extremity. Here we aimed to visualize deep-level microvascular structure in rat hind limb by microangiographic technique, and compare images with those by conventional method. MATERIALS AND METHODS: A total of 10 Sprague Dawley rats were used for in vivo and ex vivo study (five rats/group). Microangiography in vivo and ex vivo was performed and images were compared with those by conventional method. Synchrotron radiation-based micro-computed tomography (SRµCT) was also performed to reveal three-dimensional (3D) morphology of the blood vessel in rat hind limb. RESULTS: By microangiographic technique, blood vessels in the rat limb could be clearly depicted with the minimum visualized blood vessel about 9 µm in diameter, and higher angiographic scores were achieved than those by conventional X-ray. In addition, the vascular network could be defined and analyzed at the micrometer scale from the 3D renderings of limb vessel as shown by SRµCT. CONCLUSIONS: Synchrotron radiation-based microangiography and SRµCT thus provided a practical and effective means to observe the microvasculature of limbs, which might be useful in assessment of angiogenesis in lower limbs.


Subject(s)
Angiography/instrumentation , Hindlimb/blood supply , Microcirculation/physiology , Synchrotrons/instrumentation , X-Ray Microtomography/instrumentation , Angiography/methods , Animals , Male , Rats , Rats, Sprague-Dawley , X-Ray Microtomography/methods
15.
IUCrJ ; 7(Pt 5): 793-802, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32939271

ABSTRACT

Early stages of diseases, including stroke, hypertension, angiogenesis of tumours, spinal cord injuries, etc., are closely associated with the lesions of microvasculature. Rodent models of human vascular diseases are extensively used for the preclinical investigation of the disease evolution and therapy with synchrotron radiation. Therefore, non-invasive and in vivo X-ray imaging with high sensitivity and clarity is desperately needed to visualize the microvessels in live-animal models. Contrast agent is essential for the in vivo X-ray imaging of vessels and angiomatous tissue. Because of the non-rigid motion of adjacent tissues, the short circulation time and the intermittent flow of contrast agents in vessels, it is a great challenge for the traditional X-ray imaging methods to achieve well defined images of microvessels in vivo. In this article, move contrast X-ray imaging (MCXI) based on high-brightness synchrotron radiation is developed to overcome the intrinsic defects in conventional methods. Experiments with live rodents demonstrate the practicability of the MCXI method for sensitive and intact imaging of microvessels in vivo.

16.
Nat Commun ; 9(1): 2911, 2018 07 25.
Article in English | MEDLINE | ID: mdl-30046062

ABSTRACT

Upon mechanical loading, granular materials yield and undergo plastic deformation. The nature of plastic deformation is essential for the development of the macroscopic constitutive models and the understanding of shear band formation. However, we still do not fully understand the microscopic nature of plastic deformation in disordered granular materials. Here we used synchrotron X-ray tomography technique to track the structural evolutions of three-dimensional granular materials under shear. We establish that highly distorted coplanar tetrahedra are the structural defects responsible for microscopic plasticity in disordered granular packings. The elementary plastic events occur through flip events which correspond to a neighbor switching process among these coplanar tetrahedra (or equivalently as the rotation motion of 4-ring disclinations). These events are discrete in space and possess specific orientations with the principal stress direction.

17.
Sci Rep ; 6: 32380, 2016 09 01.
Article in English | MEDLINE | ID: mdl-27580585

ABSTRACT

Air sacs are thought to be the bellows for insect respiration. However, their exact mechanism of action as a bellows remains unclear. A direct way to investigate this problem is in vivo observation of the changes in their three-dimensional structures. Therefore, four-dimensional X-ray phase contrast microtomography is employed to solve this puzzle. Quantitative analysis of three-dimensional image series reveals that the compression of the air sac during respiration in bell crickets exhibits obvious anisotropic characteristics both longitudinally and transversely. Volumetric changes of the tracheal trunks in the prothorax further strengthen the evidence of this finding. As a result, we conclude that the shrinkage and expansion of the insect air sac is anisotropic, contrary to the hypothesis of isotropy, thereby providing new knowledge for further research on the insect respiratory system.


Subject(s)
Air Sacs/diagnostic imaging , Anisotropy , Insecta/anatomy & histology , X-Ray Microtomography , Animals , Imaging, Three-Dimensional , Respiration
18.
Sci Rep ; 6: 38085, 2016 11 29.
Article in English | MEDLINE | ID: mdl-27897249

ABSTRACT

Propagation-based phase-contrast computed tomography (PPCT) utilizes highly sensitive phase-contrast technology applied to X-ray micro-tomography, especially with the extensive use of synchrotron radiation (SR). Performing phase retrieval (PR) on the acquired angular projections can enhance image contrast and enable quantitative imaging. We employed the combination of SR-PPCT and PR for the histopathological evaluation of hepatic alveolar echinococcosis (HAE) disease and demonstrated the validity and superiority of PR-based SR-PPCT. A high-resolution angular projection data set of a human postoperative specimen of HAE disease was acquired, which was processed by graded ethanol concentration fixation (GECF). The reconstructed images from both approaches, with the projection data directly used and preprocessed by PR for tomographic reconstruction, were compared in terms of the tissue contrast-to-noise ratio and density spatial resolution. The PR-based SR-PPCT was selected for microscale measurement and the 3D visualization of HAE disease. Our experimental results demonstrated that the PR-based SR-PPCT technique is greatly suitable for the discrimination of pathological tissues and the characterization of HAE. In addition, this new technique is superior to conventional hospital CT and microscopy for the three-dimensional, non-destructive microscale measurement of HAE. This PR-based SR-PPCT technique has great potential for in situmicroscale histopathological analysis and diagnosis, especially for applications involving soft tissues and organs.


Subject(s)
Echinococcosis, Hepatic/diagnostic imaging , Synchrotrons , X-Ray Microtomography/instrumentation , X-Ray Microtomography/methods , Adult , Female , Humans
19.
Biomed Mater Eng ; 24(1): 1341-9, 2014.
Article in English | MEDLINE | ID: mdl-24212030

ABSTRACT

PURPOSE: To establish a method for mouse coronary angiography in vivo using synchrotron radiation, which is essential for physiological and pathological research on coronary diseases. METHODS: 1) The imaging parameters (e.g., photon energy, spatial resolution of the detector, and injection rate of contrast agent) optimal for the quality of acquired images in a simulation were determined. 2) Through animal experiments, the effectiveness of these optimal parameters and the repeatability of in vivo coronary angiography were verified. 3) An algorithm for background subtraction and contrast enhancement was designed and employed to compensate for the effects of interference and the effective information extracted used for diagnosing coronary disease. RESULTS AND CONCLUSIONS: An optimal set of the imaging parameters was finally determined: photon energy of 33-34 keV, detector's spatial resolution of 30 µm or higher, image capture rate of 20 f/s or more, concentration of lopamidol solution of 75% as contrast agent and a pulse injection of contrast agent at a high rate.


Subject(s)
Coronary Angiography , Coronary Vessels/diagnostic imaging , Synchrotrons , Algorithms , Animals , Computer Simulation , Contrast Media/chemistry , Coronary Disease/diagnostic imaging , Coronary Vessels/pathology , Image Processing, Computer-Assisted , Light , Male , Mice , Photons , Radiographic Image Interpretation, Computer-Assisted , Radiography, Thoracic , Subtraction Technique
20.
Front Biosci (Elite Ed) ; 5(2): 517-24, 2013 01 01.
Article in English | MEDLINE | ID: mdl-23277007

ABSTRACT

Detection of microvascular changes in experimental stroke models is limited by current technologies. Using state-of-the-art synchrotron radiation (SR), we explored the feasibility of detecting the normal morphological variations of lenticulostriate arteries (LSAs) and the changes to LSAs following middle cerebral artery occlusion (MCAO). Cerebral microvessels of ICR mice were imaged with synchrotron radiation microangiography using nonionic iodine and barium sulfate as contrast agents. Using SR we reproducibly observed the detailed cerebral microvasculature of LSAs arising from the origin of middle cerebral artery (MCA) with a resolution of approximately 5 micrometers, at least a 20-fold greater resolution compared to CT or MRI imaging. Notably, SR microangiography was able to reveal ischemia/reperfusion induced leakage in the lenticulostriate artery territory. To our knowledge this is the first time that the three-dimensional morphology of LSAs and real time visualization of LSA hemorrhage have been characterized in live mice. This work demonstrates that SR microangiography can provide a unique tool for furthering experimental stroke research to examine the efficacy of neuroprotective therapies on parameters such as angiogenesis and vascular integrity.


Subject(s)
Angiography/methods , Basal Ganglia Cerebrovascular Disease/etiology , Basal Ganglia Cerebrovascular Disease/pathology , Brain Ischemia/complications , Middle Cerebral Artery/pathology , Synchrotrons , Animals , Image Processing, Computer-Assisted , Mice , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL