Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 544
Filter
Add more filters

Publication year range
1.
N Engl J Med ; 2024 Aug 31.
Article in English | MEDLINE | ID: mdl-39216096

ABSTRACT

BACKGROUND: One third of patients undergoing transcatheter aortic-valve implantation (TAVI) have an indication for oral anticoagulation owing to concomitant diseases. Interruption of oral anticoagulation during TAVI may decrease the risk of bleeding, whereas continuation may decrease the risk of thromboembolism. METHODS: We conducted an international, open-label, randomized, noninferiority trial involving patients who were receiving oral anticoagulants and were planning to undergo TAVI. Patients were randomly assigned in a 1:1 ratio to periprocedural continuation or interruption of oral anticoagulation. The primary outcome was a composite of death from cardiovascular causes, stroke from any cause, myocardial infarction, major vascular complications, or major bleeding within 30 days after TAVI. RESULTS: A total of 858 patients were included in the modified intention-to-treat population: 431 were assigned to continuation and 427 to interruption of oral anticoagulation. A primary-outcome event occurred in 71 patients (16.5%) in the continuation group and in 63 (14.8%) in the interruption group (risk difference, 1.7 percentage points; 95% confidence interval [CI], -3.1 to 6.6; P = 0.18 for noninferiority). Thromboembolic events occurred in 38 patients (8.8%) in the continuation group and in 35 (8.2%) in the interruption group (risk difference, 0.6 percentage points; 95% CI, -3.1 to 4.4). Bleeding occurred in 134 patients (31.1%) in the continuation group and in 91 (21.3%) in the interruption group (risk difference, 9.8 percentage points; 95% CI, 3.9 to 15.6). CONCLUSIONS: In patients undergoing TAVI with a concomitant indication for oral anticoagulation, periprocedural continuation was not noninferior to interruption of oral anticoagulation during TAVI with respect to the incidence of a composite of death from cardiovascular causes, stroke, myocardial infarction, major vascular complications, or major bleeding at 30 days. (Funded by the Netherlands Organization for Health Research and Development and the St. Antonius Research Fund; POPular PAUSE TAVI ClinicalTrials.gov number, NCT04437303.).

2.
Eur Heart J ; 45(32): 2954-2964, 2024 Aug 21.
Article in English | MEDLINE | ID: mdl-38733175

ABSTRACT

BACKGROUND AND AIMS: In patients with chronic heart failure (HF), the MONITOR-HF trial demonstrated the efficacy of pulmonary artery (PA)-guided HF therapy over standard of care in improving quality of life and reducing HF hospitalizations and mean PA pressure. This study aimed to evaluate the consistency of these benefits in relation to clinically relevant subgroups. METHODS: The effect of PA-guided HF therapy was evaluated in the MONITOR-HF trial among predefined subgroups based on age, sex, atrial fibrillation, diabetes mellitus, left ventricular ejection fraction, HF aetiology, cardiac resynchronization therapy, and implantable cardioverter defibrillator. Outcome measures were based upon significance in the main trial and included quality of life-, clinical-, and PA pressure endpoints, and were assessed for each subgroup. Differential effects in relation to the subgroups were assessed with interaction terms. Both unadjusted and multiple testing adjusted interaction terms were presented. RESULTS: The effects of PA monitoring on quality of life, clinical events, and PA pressure were consistent in the predefined subgroups, without any clinically relevant heterogeneity within or across all endpoint categories (all adjusted interaction P-values were non-significant). In the unadjusted analysis of the primary endpoint quality-of-life change, weak trends towards a less pronounced effect in older patients (Pinteraction = .03; adjusted Pinteraction = .33) and diabetics (Pinteraction = .01; adjusted Pinteraction = .06) were observed. However, these interaction effects did not persist after adjusting for multiple testing. CONCLUSIONS: This subgroup analysis confirmed the consistent benefits of PA-guided HF therapy observed in the MONITOR-HF trial across clinically relevant subgroups, highlighting its efficacy in improving quality of life, clinical, and PA pressure endpoints in chronic HF patients.


Subject(s)
Heart Failure , Pulmonary Artery , Quality of Life , Humans , Heart Failure/therapy , Heart Failure/physiopathology , Female , Male , Aged , Middle Aged , Pulmonary Artery/physiopathology , Chronic Disease , Stroke Volume/physiology , Cardiac Resynchronization Therapy/methods , Defibrillators, Implantable
3.
Lancet ; 401(10383): 1172-1182, 2023 04 08.
Article in English | MEDLINE | ID: mdl-36889333

ABSTRACT

BACKGROUND: In patients with acute coronary syndrome and multivessel coronary disease, complete revascularisation by percutaneous coronary intervention (PCI) is associated with improved clinical outcomes. We aimed to investigate whether PCI for non-culprit lesions should be attempted during the index procedure or staged. METHODS: This prospective, open-label, non-inferiority, randomised trial was done at 29 hospitals across Belgium, Italy, the Netherlands, and Spain. We included patients aged 18-85 years presenting with ST-segment elevation myocardial infarction or non-ST-segment elevation acute coronary syndrome and multivessel (ie, two or more coronary arteries with a diameter of 2·5 mm or more and ≥70% stenosis based on visual estimation or positive coronary physiology testing) coronary artery disease with a clearly identifiable culprit lesion. A web-based randomisation module was used to randomly assign patients (1:1), with a random block size of four to eight, stratified by study centre, to undergo immediate complete revascularisation (PCI of the culprit lesion first, followed by other non-culprit lesions deemed to be clinically significant by the operator during the index procedure) or staged complete revascularisation (PCI of only the culprit lesion during the index procedure and PCI of all non-culprit lesions deemed to be clinically significant by the operator within 6 weeks after the index procedure). The primary outcome was the composite of all-cause mortality, myocardial infarction, any unplanned ischaemia-driven revascularisation, or cerebrovascular events at 1 year after the index procedure. Secondary outcomes included all-cause mortality, myocardial infarction, and unplanned ischaemia-driven revascularisation at 1 year after the index procedure. Primary and secondary outcomes were assessed in all randomly assigned patients by intention to treat. Non-inferiority of immediate to staged complete revascularisation was considered to be met if the upper boundary of the 95% CI of the hazard ratio (HR) for the primary outcome did not exceed 1·39. This trial is registered with ClinicalTrials.gov, NCT03621501. FINDINGS: Between June 26, 2018, and Oct 21, 2021, 764 patients (median age 65·7 years [IQR 57·2-72·9] and 598 [78·3%] males) were randomly assigned to the immediate complete revascularisation group and 761 patients (median age 65·3 years [58·6-72·9] and 589 [77·4%] males) were randomly assigned to the staged complete revascularisation group, and were included in the intention-to-treat population. The primary outcome at 1 year occurred in 57 (7·6%) of 764 patients in the immediate complete revascularisation group and in 71 (9·4%) of 761 patients in the staged complete revascularisation group (HR 0·78, 95% CI 0·55-1·11, pnon-inferiority=0·0011). There was no difference in all-cause death between the immediate and staged complete revascularisation groups (14 [1·9%] vs nine [1·2%]; HR 1·56, 95% CI 0·68-3·61, p=0·30). Myocardial infarction occurred in 14 (1·9%) patients in the immediate complete revascularisation group and in 34 (4·5%) patients in the staged complete revascularisation group (HR 0·41, 95% CI 0·22-0·76, p=0·0045). More unplanned ischaemia-driven revascularisations were performed in the staged complete revascularisation group than in the immediate complete revascularisation group (50 [6·7%] patients vs 31 [4·2%] patients; HR 0·61, 95% CI 0·39-0·95, p=0·030). INTERPRETATION: In patients presenting with acute coronary syndrome and multivessel disease, immediate complete revascularisation was non-inferior to staged complete revascularisation for the primary composite outcome and was associated with a reduction in myocardial infarction and unplanned ischaemia-driven revascularisation. FUNDING: Erasmus University Medical Center and Biotronik.


Subject(s)
Acute Coronary Syndrome , Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Male , Humans , Aged , Female , Acute Coronary Syndrome/surgery , Acute Coronary Syndrome/etiology , Percutaneous Coronary Intervention/methods , Prospective Studies , Myocardial Infarction/etiology , Treatment Outcome
4.
N Engl J Med ; 385(23): 2150-2160, 2021 12 02.
Article in English | MEDLINE | ID: mdl-34449183

ABSTRACT

BACKGROUND: The role of direct oral anticoagulants as compared with vitamin K antagonists for atrial fibrillation after successful transcatheter aortic-valve replacement (TAVR) has not been well studied. METHODS: We conducted a multicenter, prospective, randomized, open-label, adjudicator-masked trial comparing edoxaban with vitamin K antagonists in patients with prevalent or incident atrial fibrillation as the indication for oral anticoagulation after successful TAVR. The primary efficacy outcome was a composite of adverse events consisting of death from any cause, myocardial infarction, ischemic stroke, systemic thromboembolism, valve thrombosis, or major bleeding. The primary safety outcome was major bleeding. On the basis of a hierarchical testing plan, the primary efficacy and safety outcomes were tested sequentially for noninferiority, with noninferiority of edoxaban established if the upper boundary of the 95% confidence interval for the hazard ratio did not exceed 1.38. Superiority testing of edoxaban for efficacy would follow if noninferiority and superiority were established for major bleeding. RESULTS: A total of 1426 patients were enrolled (713 in each group). The mean age of the patients was 82.1 years, and 47.5% of the patients were women. Almost all the patients had atrial fibrillation before TAVR. The rate of the composite primary efficacy outcome was 17.3 per 100 person-years in the edoxaban group and 16.5 per 100 person-years in the vitamin K antagonist group (hazard ratio, 1.05; 95% confidence interval [CI], 0.85 to 1.31; P = 0.01 for noninferiority). Rates of major bleeding were 9.7 per 100 person-years and 7.0 per 100 person-years, respectively (hazard ratio, 1.40; 95% CI, 1.03 to 1.91; P = 0.93 for noninferiority); the difference between groups was mainly due to more gastrointestinal bleeding with edoxaban. Rates of death from any cause or stroke were 10.0 per 100 person-years in the edoxaban group and 11.7 per 100 person-years in the vitamin K antagonist group (hazard ratio, 0.85; 95% CI, 0.66 to 1.11). CONCLUSIONS: In patients with mainly prevalent atrial fibrillation who underwent successful TAVR, edoxaban was noninferior to vitamin K antagonists as determined by a hazard ratio margin of 38% for a composite primary outcome of adverse clinical events. The incidence of major bleeding was higher with edoxaban than with vitamin K antagonists. (Funded by Daiichi Sankyo; ENVISAGE-TAVI AF ClinicalTrials.gov number, NCT02943785.).


Subject(s)
4-Hydroxycoumarins/therapeutic use , Atrial Fibrillation/drug therapy , Factor Xa Inhibitors/therapeutic use , Pyridines/therapeutic use , Thiazoles/therapeutic use , Transcatheter Aortic Valve Replacement , Vitamin K/antagonists & inhibitors , 4-Hydroxycoumarins/adverse effects , Aged , Aged, 80 and over , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Factor Xa Inhibitors/adverse effects , Female , Gastrointestinal Hemorrhage/chemically induced , Humans , Intention to Treat Analysis , Kaplan-Meier Estimate , Male , Mortality , Phenindione/analogs & derivatives , Phenindione/therapeutic use , Postoperative Complications/prevention & control , Pyridines/adverse effects , Thiazoles/adverse effects , Thromboembolism/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects
5.
Am Heart J ; 277: 104-113, 2024 11.
Article in English | MEDLINE | ID: mdl-39121916

ABSTRACT

BACKGROUND: About half of patients with severe aortic stenosis present with concomitant coronary artery disease. The optimal timing of percutaneous coronary intervention (PCI) and transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and concomitant coronary artery disease remains unknown. STUDY DESIGN: The TAVI PCI trial is a prospective, international, multicenter, randomized, 2-arm, open-label study planning to enroll a total of 986 patients. It is designed to investigate whether the strategy "angiography-guided complete revascularization after (within 1-45 days) TAVI" is noninferior to the strategy "angiography-guided complete revascularization before (within 1-45 days) TAVI" using the Edwards SAPIEN 3 or 3 Ultra Transcatheter Heart Valve in patients with severe aortic stenosis and concomitant coronary artery disease. Patients are randomized in a 1:1 ratio to one of the 2 treatment strategies. The primary end point is a composite of all-cause death, nonfatal myocardial infarction, ischemia-driven revascularization, rehospitalization (valve- or procedure-related including heart failure), or life-threatening/disabling or major bleeding at 1 year. CONCLUSIONS: The TAVI PCI trial tests the hypothesis that the strategy "PCI after TAVI" is noninferior to the strategy "PCI before TAVI" in patients with severe aortic stenosis and concomitant coronary artery disease.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Percutaneous Coronary Intervention/methods , Coronary Artery Disease/surgery , Coronary Artery Disease/complications , Coronary Artery Disease/therapy , Prospective Studies , Male , Female , Coronary Angiography , Treatment Outcome
6.
Am Heart J ; 2024 Oct 22.
Article in English | MEDLINE | ID: mdl-39447716

ABSTRACT

BACKGROUND: The use of Extracorporeal Membrane Oxygenation (ECMO) remains associated with high rates of complications, weaning failure and mortality which can be partly explained by a knowledge gap on how to properly manage patients on ECMO support. To address relevant patient management issues, we designed a "Randomized Embedded Multifactorial Adaptive Platform (REMAP)" in the setting of ECMO (REMAP ECMO) and a first embedded randomized controlled trial (RCT) investigating the effects of routine early left ventricular (LV) unloading through intra-aortic balloon pumping (IABP). METHODS: REMAP ECMO describes a registry-based platform allowing for the embedding of multiple response adaptive RCTs (trial domains) which can perpetually address the effect of relevant patient management issues on ECMO weaning success. A first trial domain studies the effects of LV unloading by means of an IABP as an adjunct to veno-arterial (V-A) ECMO versus V-A ECMO alone on ECMO weaning success at 30 days in adult cardiogenic shock patients admitted to the Intensive Care Unit (ICU). The primary outcome of this trial is "successful weaning from ECMO" being defined as a composite of survival without the need for mechanical circulatory support, heart transplantation, or left ventricular assist device (LVAD) at 30 days after initiation of ECMO. Secondary outcomes include the need for interventional escalation of LV unloading strategy, mechanistic endpoints, survival characteristics until one year after ECMO initiation, and quality of life. Trial data will be analysed using a Bayesian statistical framework. The adaptive design allows for a high degree of flexibility, such as response adaptive randomization and early stopping of the trial for efficacy or futility. The REMAP ECMO LV unloading study is approved by the Medical Ethical Committee of the Erasmus Medical Center and is publicly registered. CONCLUSION: This REMAP ECMO trial platform enables the efficient roll-out of multiple RCTs on relevant patient management issues. A first embedded trial domain will compare routine LV unloading by means of an IABP as an adjunct to V-A ECMO versus V-A ECMO alone. TRIAL REGISTRATION: ClinicalTrials.gov, NCT05913622.

7.
Article in English | MEDLINE | ID: mdl-39193828

ABSTRACT

BACKGROUND: Paravalvular leakage (PVL) and conduction disorders that require permanent pacemaker implantation (PPI) remain clinically relevant challenges after transcatheter aortic valve implantation (TAVI). Computed tomography-based simulations may predict the risk of significant PVL and PPI. AIMS: To evaluate the feasibility and accuracy of preprocedural computer simulation with FEops HEARTguide™ to predict >trace PVL and PPI after TAVI with the self-expanding supra-annular ACURATE Neo2 transcatheter heart valve. METHODS: Prospective multicenter observational study that included consecutive patients undergoing TAVI with an ACURATE Neo2 valve. Computer simulations were performed before the TAVI procedure as part of the preprocedural planning. Follow-up period for PPI and PVL was 30 days. RESULTS: Sixty-five patients were included (median age 81 years (25th-75th percentile 77-84.5)). New left bundle branch block occurred in five patients (7.7%) and PPI in two patients (3%). Contact pressure index (CPI) was similar for patients with vs without new conduction disorders. Patients with PPI had numerically higher CPI than those without PPI (median CPI 20.0% (25th-75th percentile 15.0-25.0) vs. 13.0% (25th-75th percentile 5.5-18), p = 0.27). More than trace PVL occurred in 30%. Median PVL was significantly lower in patients with none-trace PVL (3.2 mL/s [25th-75th percentile 2.2-5.0]), compared to mild PVL (5.2 mL/s [25th-75th percentile 3.2-10.3]) and moderate PVL (12.6 mL/s [25th-75th percentile 3.9-21.3])(p = 0.036). A simulated PVL-cutoff of 9.65 mL/s identified patients with >trace PVL (AUC 0.70 (95% CI 0.55-0.85), sensitivity 42%, specificity 95%). CONCLUSION: In our study FEops HEARTguide™ simulations identified patients at risk for >trace PVL with ACURATE Neo2 TAVI but not for PPI.

8.
Eur Heart J ; 44(10): 836-852, 2023 03 07.
Article in English | MEDLINE | ID: mdl-36660821

ABSTRACT

AIMS: Additional randomized clinical trial (RCT) data comparing transcatheter aortic valve implantation (TAVI) with surgical aortic valve replacement (SAVR) is available, including longer term follow-up. A meta-analysis comparing TAVI to SAVR was performed. A pragmatic risk classification was applied, partitioning lower-risk and higher-risk patients. METHODS AND RESULTS: The main endpoints were death, strokes, and the composite of death or disabling stroke, occurring at 1 year (early) or after 1 year (later). A random-effects meta-analysis was performed. Eight RCTs with 8698 patients were included. In lower-risk patients, at 1 year, the risk of death was lower after TAVI compared with SAVR [relative risk (RR) 0.67; 95% confidence interval (CI) 0.47 to 0.96, P = 0.031], as was death or disabling stroke (RR 0.68; 95% CI 0.50 to 0.92, P = 0.014). There were no differences in strokes. After 1 year, in lower-risk patients, there were no significant differences in all main outcomes. In higher-risk patients, there were no significant differences in main outcomes. New-onset atrial fibrillation, major bleeding, and acute kidney injury occurred less after TAVI; new pacemakers, vascular complications, and paravalvular leak occurred more after TAVI. CONCLUSION: In lower-risk patients, there was an early mortality reduction with TAVI, but no differences after later follow-up. There was also an early reduction in the composite of death or disabling stroke, with no difference at later follow-up. There were no significant differences for higher-risk patients. Informed therapy decisions may be more dependent on the temporality of events or secondary endpoints than the long-term occurrence of main clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Stroke , Humans , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Treatment Outcome , Randomized Controlled Trials as Topic , Risk Factors , Stroke/epidemiology , Stroke/etiology
9.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Article in English | MEDLINE | ID: mdl-36883599

ABSTRACT

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prognosis , Treatment Outcome , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery
10.
Neth Heart J ; 2024 Sep 16.
Article in English | MEDLINE | ID: mdl-39283568

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as a minimally invasive alternative to mitral valve surgery for patients at high or prohibitive operative risk. Prospective studies reported favourable outcomes in patients with annulus calcification (valve-in-mitral annulus calcification; ViMAC), failed annuloplasty ring (mitral valve-in-ring; MViR), and bioprosthetic mitral valve dysfunction (mitral valve-in-valve; MViV). Multi-slice computed tomography (MSCT)-derived 3D-modelling and simulations may provide complementary anatomical perspectives for TMVR planning. AIMS: We aimed to illustrate the implementation of MSCT-derived modelling and simulations in the workup of TMVR for ViMAC, MViR, and MViV. METHODS: For this retrospective study, we included all consecutive patients screened for TMVR and compared MSCT data, echocardiographic outcomes and clinical outcomes. RESULTS: Sixteen out of 41 patients were treated with TMVR (ViMAC n = 9, MViR n = 3, MViV n = 4). Eleven patients were excluded for inappropriate sizing, 4 for anchoring issues and 10 for an unacceptable risk of left ventricular outflow tract obstruction (LVOTO) based on 3D modelling. There were 3 procedure-related deaths and 1 non-procedure-related cardiovascular death during 30 days of follow-up. LVOTO occurred in 3 ViMAC patients and 1 MViR patient, due to deeper valve implantation than planned in 3 patients, and anterior mitral leaflet displacement with recurrent basal septum thickening in 1 patient. TMVR significantly reduced mitral mean gradients as compared with baseline measurements (median mean gradient 9.5 (9.0-11.5) mm Hg before TMVR versus 5.0 (4.5-6.0) mm Hg after TMVR, p = 0.03). There was no residual mitral regurgitation at 30 days. CONCLUSION: MSCT-derived 3D modelling and simulation provide valuable anatomical insights for TMVR with transcatheter balloon expandable valves in ViMAC, MViR and MViV. Further planning iterations should target the persistent risk for neo-LVOTO.

11.
Neth Heart J ; 32(10): 348-355, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39164507

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is considered a safe and effective alternative to surgical aortic valve replacement (SAVR) for elderly patients across the operative risk spectrum. In the Netherlands, TAVI is reimbursed only for patients with a high operative risk. Despite this, one fifth of TAVI patients are < 75 years of age. We aim to compare patient characteristics and outcomes of TAVI and SAVR patients < 75 years. METHODS: This study included all patients < 75 years without active endocarditis undergoing TAVI or SAVR for severe aortic stenosis, mixed aortic valve disease or degenerated aortic bioprosthesis between 2015 and 2020 at the Erasmus University Medical Centre. Dutch authority guidelines were used to classify operative risk. RESULTS: TAVI was performed in 292 patients, SAVR in 386 patients. Based on the Dutch risk algorithm, 59.6% of TAVI patients and 19.4% of SAVR patients were at high operative risk. There was no difference in 30-day all-cause mortality between TAVI and SAVR (2.4% vs 0.8%, p = 0.083). One-year and 5­year mortality was higher after TAVI than after SAVR (1-year: 12.5% vs 4.3%, p < 0.001; 5­year: 36.8% vs 12.0%, p < 0.001). Within risk categories we found no difference between treatment strategies. Independent predictors of mortality were cardiovascular comorbidities (left ventricular ejection fraction < 30%, atrial fibrillation, pulmonary hypertension) and the presence of malignancies, liver cirrhosis or immunomodulatory drug use. CONCLUSION: At the Erasmus University Medical Centre, in patients < 75 years, TAVI is selected for higher-risk phenotypes and overall has higher long-term mortality than SAVR. We found no evidence for worse outcome within risk categories.

12.
Am Heart J ; 258: 17-26, 2023 04.
Article in English | MEDLINE | ID: mdl-36596332

ABSTRACT

BACKGROUND: The mechanisms underlying the increased risk of bleeding that female patients with ST-segment Elevation Myocardial Infarction (STEMI) exhibit, remains unclear. The present report assessed sex-related differences in response to pre-hospital dual antiplatelet therapy (DAPT) initiation in patients with STEMI. METHODS: The COMPARE CRUSH trial randomized patients presenting with STEMI to receive a pre-hospital loading dose of crushed or integral prasugrel tablets in the ambulance. In this substudy, we compared platelet reactivity levels and the occurrence of high platelet reactivity (HPR; defined as platelet reactivity ≥208) between sexes at 4 prespecified time points after DAPT initiation, and evaluated post-PCI bleeding between groups. RESULTS: Out of 633 STEMI patients, 147 (23%) were female. Females compared with males presented with significantly higher levels of platelet reactivity and higher HPR rates at baseline (232 [IQR, 209-256] vs 195 [IQR, 171-220], P < .01, and 76% vs 41%, OR 4.58 [95%CI, 2.52-8.32], P < .01, respectively). Moreover, female sex was identified as the sole independent predictor of HPR at baseline (OR 5.67 [95%CI, 2.56-12.53], P < .01). Following DAPT initiation, levels of platelet reactivity and the incidence of HPR were similar between sexes. Post-PCI bleeding occurred more frequently in females compared with males (10% vs 2%, OR 6.02 [95%CI, 2.61-11.87], P < .01). Female sex was an independent predictor of post-PCI bleeding (OR 3.25 [95%CI, 1.09-9.72], P = .04). CONCLUSIONS: In this contemporary STEMI cohort, female STEMI patients remain at risk of bleeding complications after primary PCI. However, this is not explained by sex-specific differences in the pharmacodynamic response to pre-hospital DAPT initiation.


Subject(s)
Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Female , Humans , Male , Fibrinolytic Agents/therapeutic use , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Percutaneous Coronary Intervention/adverse effects , Platelet Aggregation Inhibitors/adverse effects , Prasugrel Hydrochloride/therapeutic use , ST Elevation Myocardial Infarction/therapy , Treatment Outcome
13.
Am Heart J ; 256: 139-147, 2023 02.
Article in English | MEDLINE | ID: mdl-36410441

ABSTRACT

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Prospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/methods
14.
J Card Fail ; 29(7): 1046-1055, 2023 07.
Article in English | MEDLINE | ID: mdl-36958391

ABSTRACT

BACKGROUND: Left ventricular (LV) volume reshaping reduces myocardial wall stress and may induce reverse remodeling in patients with heart failure with reduced ejection fraction. The AccuCinch Transcatheter Left Ventricular Restoration system consists of a series of anchors connected by a cable implanted along the LV base that is cinched to the basal free wall radius. We evaluated the echocardiographic and clinical outcomes following transcatheter left ventricular restoration. METHODS AND RESULTS: We analyzed 51 heart failure patients with a left ventricular ejection fraction between 20% and 40%, with no more than 2+ mitral regurgitation treated with optimal medical therapy, who subsequently underwent transcatheter left ventricular restoration. Serial echocardiograms, Kansas City Cardiomyopathy Questionnaire scores, and 6-minute walk test distances were measured at baseline through 12 months. Primary analysis end point was change in end-diastolic volume at 12 months compared with baseline. Patients (n = 51) were predominantly male (86%) with a mean age of 56.3 ± 13.1 years. Fluoroscopy showed LV free wall radius decreased by a median of 9.2 mm amounting to a 29.6% decrease in the free wall arc length. At 12 months, the LV end-diastolic volume decreased by 33.6 ± 34.8 mL (P < .01), with comparable decreases in the LV end-systolic volume. These decreases were associated with significant improvements in the overall Kansas City Cardiomyopathy Questionnaire score (16.4 ± 18.7 points; P < .01) and 6-minute hall walk test distance (45.9 ± 83.9 m; P < .01). There were no periprocedural deaths; through the 1-year follow-up, 1 patient died (day 280) and 1 patient received a left ventricular assist device (day 13). CONCLUSIONS: In patients with heart failure with reduced ejection fraction without significant mitral regurgitation receiving optimal medical therapy, the AccuCinch System resulted in decreases of LV volume, as well as improved quality of life and exercise endurance. A randomized trial is ongoing (NCT04331769).


Subject(s)
Cardiomyopathies , Heart Failure , Mitral Valve Insufficiency , Ventricular Dysfunction, Left , Adult , Aged , Female , Humans , Male , Middle Aged , Heart Failure/diagnosis , Heart Failure/therapy , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Quality of Life , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Ventricular Remodeling
15.
Catheter Cardiovasc Interv ; 102(3): 451-463, 2023 09.
Article in English | MEDLINE | ID: mdl-37526236

ABSTRACT

OBJECTIVES: To evaluate the stent expansion of the durable-polymer Zotarolimus-eluting stent (dp-ZES), the durable-polymer Everolimus-eluting stent (dp-EES), and the bioabsorbable-polymer Sirolimus-eluting stent (bp-SES) in calcified coronary chronic total occlusions (CTO). BACKGROUND: The newer generation stents with ultrathin struts might raise concerns regarding reduced radial strength and higher stent recoil (SR) when implanted in calcified CTOs. METHODS: Between January 2017 and June 2021 consecutive patients with CTO undergoing percutaneous coronary intervention with dp-ZES, dp-EES, or bp-SES were evaluated. The analysis was performed in calcific and in noncalcific CTOs. Quantitative coronary angiography analysis was used to assess diameter stenosis (DS), absolute and relative SR, absolute and relative focal SR, absolute and relative balloon deficit (BD), and absolute and relative focal BD. The primary endpoint was DS. RESULTS: A total of 213 CTOs were evaluated, 115 calcific CTOs (dp-ZES:25, dp-EES:29, bp-SES:61) and 98 non-calcific CTOs (dp-ZES:41, dp-EES:11, bp-SES:46). In calcific CTOs, residual DS was lower in dp-ZES than in dp-EES and bp-SES (-1.00% [-6.50-6.50] vs. 13.00% [7.0-19.00] vs. 15.00% [5.00-20.00]; p < 0.001). Dp-ZES was also an independent predictor of residual DS ≤ 10% (OR 11.34, 95% CI 2.6-49.43, p = 0.001). Absolute and relative focal SR and absolute and relative SR were similar between dp-ZES, dp-EES, and bp-SES (p = 0.913, p = 0.890, p = 0.518, p = 0.426, respectively). In noncalcified CTOs, the residual DS was similar in the three groups (p = 0.340). High relative focal SR was less frequent in dp-ZES than in dp-EES and in bp-SES (19.5% vs. 54.5% vs. 37.0%; p < 0.048). CONCLUSIONS: The three stent platforms demonstrated an overall low residual DS when implanted in CTOs. However, dp-ZES was associated with the lowest residual DS and identified as independent predictor of residual DS ≤ 10% in patients with calcific CTOs. Dp-ZES was associated with a lower incidence of high relative focal stent recoil, in noncalcific CTOs. Balloon deficit might be considerate as a surrogate for stent expansion in calcified CTOs.


Subject(s)
Coronary Artery Disease , Coronary Occlusion , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Treatment Outcome , Percutaneous Coronary Intervention/adverse effects , Everolimus/adverse effects , Stents , Polymers , Absorbable Implants , Prosthesis Design , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy
16.
Catheter Cardiovasc Interv ; 102(6): 1140-1148, 2023 11.
Article in English | MEDLINE | ID: mdl-37668110

ABSTRACT

BACKGROUND: Preprocedural computed tomography planning improves procedural safety and efficacy of transcatheter aortic valve implantation (TAVI). However, contemporary imaging modalities do not account for device-host interactions. AIMS: This study evaluates the value of preprocedural computer simulation with FEops HEARTguideTM on overall device success in patients with challenging anatomies undergoing TAVI with a contemporary self-expanding supra-annular transcatheter heart valve. METHODS: This prospective multicenter observational study included patients with a challenging anatomy defined as bicuspid aortic valve, small annulus or severely calcified aortic valve. We compared the heart team's transcatheter heart valve (THV) planning decision based on (1) conventional multislice computed tomography (MSCT) and (2) MSCT imaging with FEops HEARTguideTM simulations. Clinical outcomes and THV performance were followed up to 30 days. RESULTS: A total of 77 patients were included (median age 79.9 years (IQR 74.2-83.8), 42% male). In 35% of the patients, preprocedural planning changed after FEops HEARTguideTM simulations (change in valve size selection [12%] or target implantation height [23%]). A new permanent pacemaker implantation (PPI) was implanted in 13% and >trace paravalvular leakage (PVL) occurred in 28.5%. The contact pressure index (i.e., simulation output indicating the risk of conduction abnormalities) was significantly higher in patients with a new PPI, compared to those without (16.0% [25th-75th percentile 12.0-21.0] vs. 3.5% [25th-75th percentile 0-11.3], p < 0.01) The predicted PVL was 5.7 mL/s (25th-75th percentile 1.3-11.1) in patients with none-trace PVL, 12.7 (25th-75th percentile 5.5-19.1) in mild PVL and 17.7 (25th-75th percentile 3.6-19.4) in moderate PVL (p = 0.04). CONCLUSION: FEops HEARTguideTM simulations may provide enhanced insights in the risk for PVL or PPI after TAVI with a self-expanding supra-annular THV in complex anatomies.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Male , Aged , Aged, 80 and over , Female , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Computer Simulation , Prospective Studies , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Multidetector Computed Tomography/methods , Prosthesis Design
17.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Article in English | MEDLINE | ID: mdl-37668097

ABSTRACT

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Retrospective Studies , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects
18.
Catheter Cardiovasc Interv ; 102(2): 191-199, 2023 08.
Article in English | MEDLINE | ID: mdl-37232425

ABSTRACT

BACKGROUND: Dedicated prospective studies investigating high-definition intravascular ultrasound (HD-IVUS)-guided primary percutaneous coronary intervention (PCI) are lacking. The aim of this study was to qualify and quantify culprit lesion plaque characteristics and thrombus using HD-IVUS in patients presenting with ST-segment elevation myocardial infarction (STEMI). METHODS: The SPECTRUM study is a prospective, single-center, observational cohort study investigating the impact of HD-IVUS-guided primary PCI in 200 STEMI patients (NCT05007535). The first 100 study patients with a de novo culprit lesion and a per-protocol mandated preintervention pullback directly after vessel wiring were subject to a predefined imaging analysis. Culprit lesion plaque characteristics and different thrombus types were assessed. An IVUS-derived thrombus score, including a 1-point adjudication for a long total thrombus length, long occlusive thrombus length, and large maximum thrombus angle, was developed to differentiate between low (0-1 points) and high (2-3 points) thrombus burden. Optimal cut-off values were obtained using receiver operating characteristic curves. RESULTS: The mean age was 63.5 (±12.1) years and 69 (69.0%) patients were male. The median culprit lesion length was 33.5 (22.8-38.9) mm. Plaque rupture and convex calcium were appreciated in 48 (48.0%) and 10 (10.0%) patients, respectively. Thrombus was observed in 91 (91.0%) patients (acute thrombus 3.3%; subacute thrombus 100.0%; organized thrombus 22.0%). High IVUS-derived thrombus burden was present in 37/91 (40.7%) patients and was associated with higher rates of impaired final thrombolysis in myocardial infarction flow (grade 0-2) (27.0% vs. 1.9%, p < 0.001). CONCLUSIONS: HD-IVUS in patients presenting with STEMI allows detailed culprit lesion plaque characterization and thrombus grading that may guide tailored PCI.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , ST Elevation Myocardial Infarction , Thrombosis , Humans , Male , Middle Aged , Female , ST Elevation Myocardial Infarction/diagnostic imaging , ST Elevation Myocardial Infarction/therapy , Prospective Studies , Percutaneous Coronary Intervention/adverse effects , Coronary Angiography , Treatment Outcome , Ultrasonography, Interventional/methods , Myocardial Infarction/pathology
19.
Catheter Cardiovasc Interv ; 102(1): 25-35, 2023 07.
Article in English | MEDLINE | ID: mdl-37210611

ABSTRACT

BACKGROUND: Severe coronary artery calcification is associated with stent underexpansion and subsequent stent failure. AIMS: We aimed to identify optical coherence tomography (OCT)-derived predictors of absolute (minimal stent area [MSA]) and relative stent expansion in calcified lesions. METHODS: This retrospective cohort study included patients who underwent percutaneous coronary intervention (PCI) with OCT assessment before and after stent implantation between May 2008 and April 2022. Pre-PCI OCT was used to assess calcium burden and post-PCI OCT was used to assess absolute and relative stent expansion. RESULTS: A total of 361 lesions in 336 patients were analyzed. Target lesion calcification (defined as OCT-detected maximum calcium angle ≥ 30°) was present in 242 (67.0%) lesions. Following PCI, median MSA was 5.37 mm2 in calcified lesions and 6.24 mm2 in noncalcified lesions (p < 0.001). Median stent expansion was 78% in calcified lesions and 83% in noncalcified lesions (p = 0.325). In the subset of calcified lesions, average stent diameter, preprocedural minimal lumen area, and total calcium length were independent predictors of MSA in multivariable analysis (mean difference 2.69 mm2 /mm2 , 0.52 mm2 /mm, and -0.28 mm2 /5 mm, respectively, all p < 0.001). Total stent length was the only independent predictor of relative stent expansion (mean difference -0.465% per mm, p < 0.001). Calcium angle, thickness, and the presence of nodular calcification were not significantly associated with MSA or stent expansion in multivariable analyses. CONCLUSION: Calcium length appeared to be the most important OCT-derived predictor of MSA, whereas stent expansion was mainly determined by total stent length.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Vascular Calcification , Humans , Percutaneous Coronary Intervention/adverse effects , Tomography, Optical Coherence/methods , Retrospective Studies , Calcium , Treatment Outcome , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy , Vascular Calcification/pathology , Coronary Vessels/diagnostic imaging , Coronary Vessels/pathology , Predictive Value of Tests , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/pathology , Stents , Coronary Angiography/methods
20.
Eur Heart J ; 43(13): 1307-1316, 2022 03 31.
Article in English | MEDLINE | ID: mdl-34617993

ABSTRACT

AIMS: The SYNTAX II study evaluated the impact of advances in percutaneous coronary intervention (PCI), integrated into a single revascularization strategy, on outcomes of patients with de novo three-vessel disease. The study employed decision-making utilizing the SYNTAX score II, use of coronary physiology, thin-strut biodegradable polymer drug-eluting stents, intravascular ultrasound, enhanced treatments of chronic total occlusions, and optimized medical therapy. Patients treated with this approach were compared with predefined patients from the SYNTAX I trial. METHODS AND RESULTS: SYNTAX II was a multicentre, single-arm, open-label study of patients requiring revascularization who demonstrated clinical equipoise for treatment with either coronary artery bypass grafting (CABG) or PCI, predicted by the SYNTAX score II. The primary endpoint was major adverse cardiac and cerebrovascular events (MACCE), which included any revascularization. The comparators were a matched PCI cohort trial and a matched CABG cohort, both from the SYNTAX I trial. At 5 years, MACCE rate in SYNTAX II was significantly lower than in the SYNTAX I PCI cohort (21.5% vs. 36.4%, P < 0.001). This reflected lower rates of revascularization (13.8% vs. 23.8%, P < 0.001), and myocardial infarction (MI) (2.7% vs. 10.4%, P < 0.001), consisting of both procedural MI (0.2% vs. 3.8%, P < 0.001) and spontaneous MI (2.3% vs. 6.9%, P = 0.004). All-cause mortality was lower in SYNTAX II (8.1% vs. 13.8%, P = 0.013) reflecting a lower rate of cardiac death (2.8% vs. 8.4%, P < 0.001). Major adverse cardiac and cerebrovascular events' outcomes at 5 years among patients in SYNTAX II and predefined patients in the SYNTAX I CABG cohort were similar (21.5% vs. 24.6%, P = 0.35). CONCLUSIONS: Use of the SYNTAX II PCI strategy in patients with de novo three-vessel disease led to improved and durable clinical results when compared to predefined patients treated with PCI in the original SYNTAX I trial. A predefined exploratory analysis found no significant difference in MACCE between SYNTAX II PCI and matched SYNTAX I CABG patients at 5-year follow-up.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Coronary Artery Bypass/methods , Coronary Artery Disease/therapy , Humans , Percutaneous Coronary Intervention/methods , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL