Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
BMC Geriatr ; 24(1): 517, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38872086

ABSTRACT

BACKGROUND: In the hospital setting, frailty is a significant risk factor, but difficult to measure in clinical practice. We propose a reweighting of an existing diagnoses-based frailty score using routine data from a tertiary care teaching hospital in southern Germany. METHODS: The dataset includes patient characteristics such as sex, age, primary and secondary diagnoses and in-hospital mortality. Based on this information, we recalculate the existing Hospital Frailty Risk Score. The cohort includes patients aged ≥ 75 and was divided into a development cohort (admission year 2011 to 2013, N = 30,525) and a validation cohort (2014, N = 11,202). A limited external validation is also conducted in a second validation cohort containing inpatient cases aged ≥ 75 in 2022 throughout Germany (N = 491,251). In the development cohort, LASSO regression analysis was used to select the most relevant variables and to generate a reweighted Frailty Score for the German setting. Discrimination is assessed using the area under the receiver operating characteristic curve (AUC). Visualization of calibration curves and decision curve analysis were carried out. Applicability of the reweighted Frailty Score in a non-elderly population was assessed using logistic regression models. RESULTS: Reweighting of the Frailty Score included only 53 out of the 109 frailty-related diagnoses and resulted in substantially better discrimination than the initial weighting of the score (AUC = 0.89 vs. AUC = 0.80, p < 0.001 in the validation cohort). Calibration curves show a good agreement between score-based predictions and actual observed mortality. Additional external validation using inpatient cases aged ≥ 75 in 2022 throughout Germany (N = 491,251) confirms the results regarding discrimination and calibration and underlines the geographic and temporal validity of the reweighted Frailty Score. Decision curve analysis indicates that the clinical usefulness of the reweighted score as a general decision support tool is superior to the initial version of the score. Assessment of the applicability of the reweighted Frailty Score in a non-elderly population (N = 198,819) shows that discrimination is superior to the initial version of the score (AUC = 0.92 vs. AUC = 0.87, p < 0.001). In addition, we observe a fairly age-stable influence of the reweighted Frailty Score on in-hospital mortality, which does not differ substantially for women and men. CONCLUSIONS: Our data indicate that the reweighted Frailty Score is superior to the original Frailty Score for identification of older, frail patients at risk for in-hospital mortality. Hence, we recommend using the reweighted Frailty Score in the German in-hospital setting.


Subject(s)
Electronic Health Records , Frail Elderly , Frailty , Hospital Mortality , Humans , Aged , Germany/epidemiology , Female , Male , Frailty/diagnosis , Frailty/epidemiology , Frailty/mortality , Retrospective Studies , Aged, 80 and over , Risk Assessment/methods , Hospital Mortality/trends , Geriatric Assessment/methods , Risk Factors , Hospitalization
2.
ASAIO J ; 70(3): e43-e45, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38411927

ABSTRACT

For patients on venoarterial extracorporeal membrane oxygenation support where ready-to-wean criteria are met, complications during the decannulation are quite common. Management of these complications can be challenging as many of the remaining standard arterial access sites are in use or had prior closure by a closure device. In this case report of a 70-year-old patient, explantation of the arterial cannula with the help of a vascular closure device led to thrombotic occlusion of the distal femoral artery. Here, we describe a step-by-step guide outlining our approach on management of this complication. Most relevantly, a distal femoral access via the superficial femoral artery was used, and thrombus aspiration was done with the help of the AngioJet peripheral thrombectomy system.


Subject(s)
Extracorporeal Membrane Oxygenation , Humans , Aged , Lower Extremity , Device Removal , Femoral Artery/surgery , Thrombectomy
3.
Sci Rep ; 14(1): 1869, 2024 01 22.
Article in English | MEDLINE | ID: mdl-38253776

ABSTRACT

Pigs are frequently applied as animal models in cardiovascular research due to their anatomical and physiological similarity to humans. For study planning and refinement, precise knowledge of the cardioaortic dimensions is essential. In a retrospective single-center study, the cardioaortic dimensions and left ventricular function of German Landrace pigs were assessed using cardiac MRI. All parameters were compared between male and female pigs and analyzed for correlation with body weight. In total, 15 pigs were included (7 male and 8 female, weight 60.9 ± 7.0 kg). The left ventricle revealed an end-diastolic diameter of 50.5 ± 4.4 mm and an ejection fraction of 51.2 ± 9.8%. The diameters of the ascending and descending aorta were 21.3 ± 2.3 and 16.2 ± 1.4 mm, respectively. There were no significant differences between male and female pigs, except that males had a smaller end-diastolic left ventricular volume (p = 0.041). A moderate correlation was found between body weight and the aortic annulus diameter (R = 0.57, p = 0.027). In conclusion, cardiac MRI allows precise quantification of porcine cardioaortic dimensions. For medical device testing, size differences between pigs and humans should be considered.


Subject(s)
Heart , Magnetic Resonance Imaging , Humans , Female , Male , Swine , Animals , Retrospective Studies , Heart/diagnostic imaging , Heart Ventricles/diagnostic imaging , Body Weight
4.
J Cardiol ; 84(2): 99-104, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38307247

ABSTRACT

BACKGROUND: In transcatheter aortic valve replacement (TAVR), complications may force the need for a surgical bailout, but knowledge is rare about outcomes in Germany. METHODS: Using national health records, we investigated all TAVR in German hospitals between 2007 and 2020, focusing on 2018-2020. We extracted data on those interventions with need for a surgical bailout. RESULTS: A total of 159,643 TAVR were analyzed, with an overall rate of surgical bailout of 2.30 %, an overall in-hospital mortality of 3.85 %, and in-hospital mortality in case of bailout of 16.51 %. The number of all annual TAVR procedures increased substantially (202 to 22,972), with the rate of surgical bailout declining from 27.23 to 0.61 % and overall mortality from 11.39 to 2.29 %. However, in-hospital mortality after bailout was still high (28.37 % in 2020). The standardized rates of overall mortality and surgical bailout between 2018 and 2020 were significantly lower for balloon-expandable and self-expanding transfemoral TAVR than for transapical TAVR after risk adjustment [transapical/transfemoral balloon-expandable/transfemoral self-expanding TAVR: in-hospital mortality: 5.66 % (95 % CI 4.81 %; 6.52 %)/2.30 % (2.03 %; 2.57 %)/2.32 % (2.07 %; 2.57 %); surgical bailout: 2.33 % (1.68 %; 2.97 %)/0.79 % (0.60 %; 0.98 %)/0.42 % (0.31 %; 0.53 %)]. Coronary artery disease [risk-adjusted OR = 1.50 (1.21; 1.85), p < 0.001] and atrial fibrillation [OR = 1.29 (1.07; 1.57), p = 0.009] were found to be the main risk factors for bailout. CONCLUSIONS: Rates of TAVR with need for a surgical bailout and overall in-hospital mortality have declined noticeably over the years in Germany. However, the outcomes are still unfavorable after surgical bailout, as in-hospital mortality is continuously high. We present risk factors for surgical bailout to improve preparation of subsequent measures. It must be a major goal to further reduce the rate of surgical bailouts in the future.


Subject(s)
Aortic Valve Stenosis , Hospital Mortality , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/mortality , Germany/epidemiology , Male , Female , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Postoperative Complications/epidemiology , Risk Factors , Aortic Valve/surgery
5.
Sci Rep ; 14(1): 606, 2024 01 05.
Article in English | MEDLINE | ID: mdl-38182761

ABSTRACT

Magnetic resonance imaging (MRI) provides a multitude of techniques to detect and characterize myocardial infarction. To correlate MRI findings with histology, in most cases terminal animal studies are performed; however, precise extraction and spatial correlation of myocardial tissue samples to MRI image data is difficult. In this proof of concept study, we present a 3D-printing technique to facilitate the extraction of tissue samples from myocardial regions. Initially, seven pig hearts embedded in formaldehyde were imaged on a clinical 3 T system to define biopsy targets on high resolution ex vivo images. Magnitude images and R2*-maps acquired with a 3D multi-echo gradient echo sequence and 0.58 mm isotropic resolution were used to create digital models of the cardiac anatomy. Biopsy guides were 3D-printed to steer the extraction of myocardial samples. In total, 61 tissue samples were extracted with an average offset of the tissue sample location from the target location of 0.59 ± 0.36 mm. This offset was not dependent on the distance of the target point to the epicardial surface. Myocardial tissue could be extracted from all samples. The presented method enables extraction of myocardial tissue samples that are selected by ex vivo MRI with submillimeter precision.


Subject(s)
Heart , Myocardium , Animals , Swine , Biopsy , Heart/diagnostic imaging , Magnetic Resonance Imaging , Printing, Three-Dimensional
6.
Int J Cardiovasc Imaging ; 40(4): 811-820, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38360986

ABSTRACT

To compare the diagnostic value of ultrahigh-resolution CT-angiography (UHR-CTA) compared with high-pitch spiral CTA (HPS-CTA) using a first-generation, dual-source photon-counting CT (PCD-CT) scanner for preprocedural planning of transcatheter aortic valve replacement (TAVR). Clinically referred patients with severe aortic valve stenosis underwent both, retrospective ECG-gated cardiac UHR-CTA (collimation: 120 × 0.2 mm) and prospective ECG-triggered aortoiliac HPS-CTA (collimation: 144 × 0.4 mm, full spectral capabilities) for TAVR planning from August 2022 to March 2023. Radiation dose was extracted from the CT reports, and the effective dose was calculated. Two radiologists analyzed UHR-CTA and HPS-CTA datasets, assessing the image quality of the aortic annulus, with regard to the lumen visibility and margin delineation using a 4-point visual-grading scale (ranges: 4 = "excellent" to 1 = "poor"). Aortic annulus area (AAA) measurements were taken for valve prosthesis sizing, with retrospective UHR-CTA serving as reference standard. A total of 64 patients were included (mean age, 81 years ± 7 SD; 28 women) in this retrospective study. HPS-CTA showed a lower radiation dose, 4.1 mSv vs. 12.6 mSv (p < 0.001). UHR-CTA demonstrated higher image quality to HPS-CTA (median score, 4 [IQR, 3-4] vs. 3 [IQR, 2-3]; p < 0.001). Quantitative assessments of AAA from both CTA datasets were strongly positively correlated (mean 477.4 ± 91.1 mm2 on UHR-CTA and mean 476.5 ± 90.4 mm2 on HPS-CTA, Pearson r2 = 0.857, p < 0.001) with a mean error of 22.3 ± 24.6 mm2 and resulted in identical valve prosthesis sizing in the majority of patients (91%). Patients with lower image quality on HPS-CTA (score value 1 or 2, n = 28) were more likely to receive different sizing recommendations (82%). Both UHR-CTA and HPS-CTA acquisitions using photon-counting CT technology provided reliable aortic annular assessments for TAVR planning. While UHR-CTA offers superior image quality, HPS-CTA is associated with lower radiation exposure. However, severely impaired image quality on HPS-CTA may impact on prosthesis sizing, suggesting that immediate post-scan image evaluations may require complementary UHR-CTA scanning.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac-Gated Imaging Techniques , Computed Tomography Angiography , Electrocardiography , Heart Valve Prosthesis , Predictive Value of Tests , Prosthesis Design , Radiation Dosage , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Female , Male , Retrospective Studies , Aged, 80 and over , Aged , Transcatheter Aortic Valve Replacement/instrumentation , Reproducibility of Results , Severity of Illness Index , Radiation Exposure , Clinical Decision-Making , Photons , Multidetector Computed Tomography
SELECTION OF CITATIONS
SEARCH DETAIL