Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
Add more filters

Publication year range
1.
BMC Cardiovasc Disord ; 24(1): 51, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38221637

ABSTRACT

Mitral valve aneurysm (MVA) is characterized by a saccular outpouching of the mitral leaflet, and it represents a rare condition typically associated with aortic valve endocarditis. Three-Dimensional Transesophageal Echocardiography (3D-TEE) serves as an effective tool for detecting the presence of MVA and its potential complications. In this report, we present a case involving a young man with striking images of bicuspid aortic valve endocarditis complicated by an aortic root abscess and multiple perforated mitral valve aneurysms, diagnosed using 3D TEE. This case suggests the uncommon coexistence of Marfan like morphotype, bicuspid aortic valve, and infective endocarditis as a triple mechanism in the occurrence of MVA. It underscores the significance of early and accurate imaging diagnosis for facilitating prompt surgical intervention.


Subject(s)
Bicuspid Aortic Valve Disease , Echocardiography, Three-Dimensional , Endocarditis, Bacterial , Endocarditis , Heart Aneurysm , Marfan Syndrome , Humans , Male , Abscess/diagnostic imaging , Abscess/etiology , Aorta, Thoracic , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Bicuspid Aortic Valve Disease/complications , Echocardiography, Transesophageal/methods , Endocarditis/complications , Endocarditis/diagnostic imaging , Endocarditis, Bacterial/complications , Endocarditis, Bacterial/diagnostic imaging , Endocarditis, Bacterial/surgery , Heart Aneurysm/etiology , Heart Aneurysm/complications , Marfan Syndrome/complications , Marfan Syndrome/diagnosis , Mitral Valve/diagnostic imaging , Mitral Valve/surgery
2.
Echocardiography ; 41(3): e15783, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38456307

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is gradually becoming an alternative therapy for patients who cannot adapt to surgical treatment or have contraindications. OBJECTIVES: The purpose of this study was to investigate the value of echocardiography in the evaluation of severe AR patients treated with TAVR and to analyze the correlations with postprocedural complications to improve the evaluation and screening of patients. METHODS: We retrospectively analyzed clinical and echocardiographic data of 70 patients with severe AR. Periaortic valve structures were carefully measured by esophageal echocardiography (TEE) and compared with the multilayer slice computed tomography (MSCT) findings. Real-time three-dimensional esophageal echocardiography (RT-3D TEE) was monitored during the operation, and a 30-day postprocedural follow-up was performed. The relationship between postprocedural complications and patients' clinical data or periaortic valve structures was analyzed by multifactorial analysis to identify relevant predictors of complications. RESULTS: The TEE measurements of periaortic valve structures were in good agreement with the MSCT measurements. Among the patients who underwent successful operations, both left atrial (LA) and left ventricular (LV) diameters were reduced, and the left ventricular ejection fraction (LVEF) was improved 30 days after TAVR compared with the preprocedural period (P < .05). Permanent pacemakers were implanted in 15 patients. The presence of preprocedural right bundle branch block (RBBB) (OR: 2.93; 95% CI: 1.18-12.70; P = .01) was an independent factor for permanent pacemaker implantation after TAVR. CONCLUSIONS: Echocardiography plays an extremely important role in TAVR procedures. The presence of preprocedural RBBB can be an independent predictor of postprocedural pacemaker implantation.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Insufficiency/surgery , Retrospective Studies , Stroke Volume , Treatment Outcome , Heart Valve Prosthesis/adverse effects , Ventricular Function, Left , Echocardiography/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
3.
Echocardiography ; 40(9): 932-941, 2023 09.
Article in English | MEDLINE | ID: mdl-37498192

ABSTRACT

BACKGROUND: The purpose of the study was to determine the association between vena contracta area (VCA) and secondary leaflet tethering among mitral valve prolapse (MVP) patients, and thus to further identify and characterize an MVP with pathological leaflet tethering (MVPt+) phenotype. METHODS: We prospectively evaluated 94 consecutive MVP patients with significant mitral regurgitation (MR) and 21 healthy controls. MVPt+ group was defined as tenting volume index (TVi) > .7 mL/m2 . The three-dimensional (3D) geometry of mitral valve apparatus and VCA was measured with dedicated quantification software. RESULTS: Of the 94 patients with MVP and significant MR, 31 patients showed a TVi > .7 mL/m2 and entered the MVP with leaflet tethering (MVPt+) group. In stepwise multivariate analysis, only prolapse volume index and TVi were independently associated with 3D VCA. 3D VCA, annular area index, and plasma levels of NT-proBNP were independently correlated with the severity of leaflet tethering. ROC curve revealed that a 3D VCA ≥ .55 cm2 is the optimal cutoff point to predict MVPt+ phenotype. CONCLUSIONS: Secondary leaflet tethering is a significant mechanism behind severe degenerative MR, resulting in an MVPt+ phenotype featuring more advanced morphological and hemodynamical characteristics.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Mitral Valve Prolapse , Humans , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Mitral Valve Prolapse/complications , Mitral Valve/diagnostic imaging
4.
Echocardiography ; 39(3): 457-464, 2022 03.
Article in English | MEDLINE | ID: mdl-35122306

ABSTRACT

PURPOSE: Cardiac resynchronization therapy (CRT) positively affects the improvement of functional mitral regurgitation (MR) in patients with heart failure with reduced ejection fraction (HFrEF). However, geometric changes in the mitral valve apparatus, subvalvular structures and their contribution to improving mitral regurgitation after CRT have not been clearly defined. Our study aimed to evaluate the geometric parameters of mitral valve apparatus measured with three-dimensional (3D) transesophageal echocardiography (TEE) before CRT implantation and to determine the parameters predicting the improvement of MR after CRT. METHODS: In this prospective study, we included thirty patients with moderate or severe MR and HFrEF planned for CRT implantation who had an indication for TEE. Before CRT implantation, effective regurgitant orifice (ERO) and regurgitant volume (RV) measurements were performed. Detailed quantitative measurements of the mitral valve were done from recorded images by 3D TEE. ERO and RV measurements were repeated to evaluate MR at the end of the third month. RESULTS: There were no significant changes in left ventricular EF and left ventricular diameters at third-month follow-up, whereas ERO and RV values were decreased. The posterior leaflet angle was higher in the non-responder group than the responder group (28.93 ± 8.41 vs 41.25 ± 10.90, p = 0.006). The posterior leaflet angle was an independent predictor of decreased RV and ERO. CONCLUSION: Among HFrEF patients with moderate or severe functional MR who underwent CRT implantation had a lower posterior leaflet angle, which was measured by 3D TEE, in the patient group whose MR improved after CRT.


Subject(s)
Cardiac Resynchronization Therapy , Echocardiography, Three-Dimensional , Heart Failure , Mitral Valve Insufficiency , Cardiac Resynchronization Therapy/methods , Echocardiography, Transesophageal , Heart Failure/complications , Heart Failure/diagnostic imaging , Heart Failure/therapy , Humans , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/therapy , Prospective Studies , Stroke Volume
5.
Echocardiography ; 39(6): 851-854, 2022 06.
Article in English | MEDLINE | ID: mdl-35610733

ABSTRACT

BACKGROUND: Accessory mitral valve tissue (AMVT) is an extremely rare causes left ventricular outflow tract (LVOT) obstruction and is usually incidentally detected in childhood. It is often associated with other cardiac and vascular congenital malformations. CASE PRESENTATION: In this case, we present a 15-year-old girl was diagnosed with AMVT by transesophageal echocardiography, resulting in LVOT obstruction during systole. Interestingly enough, the patient's accessory mitral valve remained undetected for years until he became symptomatic for wide ASD. Successful closure of the ASD with resection of the AMVT was performed with a transaortic approach. The patient was hemodynamically stable postoperatively. There were no abnormalities in the mitral valves and LVOT. CONCLUSION: It was also unusual to see AMVT with ASD instead of other frequently associated other congenital anomalies. Accessory mitral valve should be considered a rare but important cause of left ventricular outflow tract obstruction in childhood.


Subject(s)
Echocardiography, Three-Dimensional , Heart Defects, Congenital , Heart Septal Defects, Atrial , Ventricular Dysfunction, Left , Ventricular Outflow Obstruction , Adolescent , Echocardiography, Transesophageal , Female , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnostic imaging , Heart Defects, Congenital/surgery , Heart Septal Defects, Atrial/complications , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Humans , Male , Mitral Valve/abnormalities , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Ventricular Dysfunction, Left/complications , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery
6.
Circ J ; 85(7): 1001-1010, 2021 06 25.
Article in English | MEDLINE | ID: mdl-33612563

ABSTRACT

BACKGROUND: The aim of this study was to clarify the clinical outcomes of patients with atrial functional mitral regurgitation (FMR) who underwent the MitraClip procedure compared with those with conventional FMR and sinus rhythm (SR).Methods and Results:Of 303 patients with FMR who underwent the MitraClip procedure, 40 with "atrial-FMR" defined as FMR with permanent atrial fibrillation and normal left ventricular (LV) function/size and 115 with "sinus-FMR" defined as FMR with SR and LV dysfunction were reviewed. Transthoracic and 3D transesophageal echocardiography, and the cardiac complication rate (composite of all-cause death, heart failure admission, mitral valve (MV) surgery, and redo MitraClip procedure) during the 12-month follow-up were compared between the groups. After the MitraClip procedure, reductions in the mitral annular area and its anteroposterior dimension and in the leaflet closure area were observed in both groups. MV orifice area was smaller with greater transmitral pressure gradient (P<0.05) after the procedure in atrial-FMR patients than in those with sinus-FMR. The prevalence of residual MR was similar, but significant tricuspid regurgitation (TR) was more prevalent in the atrial-FMR group at follow-up. Cardiac complication rate was comparable between groups (20% vs. 25%, P=0.63). CONCLUSIONS: Reduction of MR occurred in atrial-FMR probably because of the increase in leaflet coaptation area. Significant TR was more common after the MitraClip procedure in patients with atrial-FMR than with sinus-FMR. However, mid-term outcomes were comparable between patients with atrial-FMR and sinus-FMR.


Subject(s)
Mitral Valve Insufficiency , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Treatment Outcome , Ventricular Function, Left
7.
Echocardiography ; 38(4): 646-656, 2021 04.
Article in English | MEDLINE | ID: mdl-33749914

ABSTRACT

Mitral commissural prolapse or flail, either isolated or combined with more extensive degenerative valve disease, imposes several challenges both on its diagnosis and management while being a risk factor for valve reoperation after mitral valve repair. Accurate identification of the prolapsing segment is often not feasible with transthoracic 2D echocardiography, with transesophageal 3D imaging then required for correct diagnosis and surgical planning. Various surgical techniques employed alone or in combination have yielded good results in the repair of commissural prolapse. Herein, we analyze the specific characteristics of commissural disease focusing our attention on 2D and 3D echocardiographic findings and we briefly comment on techniques employed for surgical correction of the disease.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Insufficiency , Mitral Valve Prolapse , Echocardiography, Transesophageal , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/surgery , Prolapse
8.
J Cardiothorac Vasc Anesth ; 35(2): 514-529, 2021 Feb.
Article in English | MEDLINE | ID: mdl-32622708

ABSTRACT

OBJECTIVE: The aim of this study was to compare the mutual interchangeability of 4 cardiac output measuring devices by comparing their accuracy, precision, and trending ability. DESIGN: A single-center prospective observational study. DESIGN: Nonuniversity teaching hospital, single center. PARTICIPANTS: Forty-four consecutive patients scheduled for elective, nonemergent coronary artery bypass grafting (CABG). INTERVENTIONS: The cardiac output was measured for each participant using 4 methods: intermittent thermodilution via pulmonary artery catheter (ITD-PAC), Endotracheal Cardiac Output Monitor (ECOM), FloTrac/Vigileo System (FLOTRAC), and 3-dimensional transesophageal echocardiography (3D-TEE). MEASUREMENTS AND MAIN RESULTS: Measurements were performed simultaneously at 5 time points: presternotomy, poststernotomy, before cardiopulmonary bypass, after cardiopulmonary bypass, and after sternal closure. A series of statistical and comparison analyses including ANOVA, Pearson correlation, Bland-Altman plots, quadrant plots, and polar plots were performed, and inherent precision for each method and percent errors for mutual interchangeability were calculated. For the 6 two-by-two comparisons of the methods, the Pearson correlation coefficients (r), the percentage errors (% error), and concordance ratios (CR) were as follows: ECOM_versus_ITD-PAC (r = 0.611, % error = 53%, CR = 75%); FLOTRAC_versus_ITD-PAC (r = 0.676, % error = 49%, CR = 77%); 3D-TEE versus ITD-PAC (r = 0.538, % error = 64%, CR = 67%); FLOTRAC_versus_ECOM (r = 0.627, % error = 51%, CR = 75%); 3D-TEE_versus ECOM (r = 0.423, % error = 70%, CR = 60%), and 3D-TEE_versus_FLOTRAC (r = 0.602, % error = 59%, CR = 61%). CONCLUSIONS: Based on the recommended statistical measures of interchangeability, ECOM, FLOTRAC, and 3D-TEE are not interchangeable with each other or to the reference standard invasive ITD-PAC method in patients undergoing nonemergent cardiac bypass surgery. Despite the negative result in this study and the majority of previous studies, these less-invasive methods of CO have continued to be used in the hemodynamic management of patients. Each device has its own distinct technical features and inherent limitations; it is clear that no single device can be used universally for all patients. Therefore, different methods or devices should be chosen based on individual patient conditions, including the degree of invasiveness, measurement performance, and the ability to provide real-time, continuous CO readings.


Subject(s)
Monitoring, Intraoperative , Thermodilution , Cardiac Output , Catheterization, Swan-Ganz , Coronary Artery Bypass , Humans , Reproducibility of Results
9.
Echocardiography ; 37(12): 2071-2081, 2020 12.
Article in English | MEDLINE | ID: mdl-33026122

ABSTRACT

AIMS: Aortic stenosis (AS) grading by 2D-transthoracic echocardiography (2D-TTE) aortic valve area (AVA) calculation is limited by left ventricular outflow tract (LVOT) area underestimation. The combination of Doppler parameters with 3D LVOT area obtained by multidetector computed tomography (MDCT) can improve AS grading, reconciling discordant 2D-TTE findings. This study aimed to systematically evaluate the role of 3D-transesophageal echocardiography (3D-TEE) in AS grading using MDCT as reference standard. METHODS AND RESULTS: 288 patients (81 ± 6.3 years, 52.4% female) with symptomatic AS underwent 2D-TTE, 3D-TEE, and MDCT for transcatheter aortic valve implantation. Doppler parameters were combined with 3D LVOT areas measured by manual and semi-automated software 3D-TEE and by MDCT to calculate AVA, reassessing AS severity. Both 3D-TEE modalities demonstrated good correlation with MDCT, with excellent intra-observer and inter-observer variability. Compared to MDCT, 3D-TEE measurements significantly underestimated AVA (PANOVA  < .0001), although the difference was clinically acceptable. Compared to 2D-TTE, 3D-TEE manual and semi-automated software reclassified severe AS in 21.9% and 25.2% of cases, respectively (P < .0001), overcame grading parameters discordance in more than 40% of cases in patients with low-gradient AS (P < .0001) and reduced the proportion of low-flow states in nearly 75% of cases when combined to stroke volume index assessment (P < .0001). 3D-TEE imaging modalities showed a reduction in the proportion of patients with low-gradient and pathological AVA as defined by 2D-TTE, and improved AVA and mean pressure gradient agreement with current guidelines cutoff values. CONCLUSION: 3D-TEE AVA calculation is a reliable tool for AS grading with excellent reproducibility and good correlation with MDCT measurements.


Subject(s)
Aortic Valve Stenosis , Echocardiography, Three-Dimensional , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Echocardiography, Transesophageal , Female , Humans , Male , Reproducibility of Results
10.
Echocardiography ; 36(7): 1434-1436, 2019 07.
Article in English | MEDLINE | ID: mdl-31215683

ABSTRACT

An 8-year-old boy with tetralogy of Fallot, pulmonary atresia, and major aortopulmonary collaterals status post complete repair including a fenestrated ventricular septal defect patch presented to the catheterization laboratory for fenestration closure. During the procedure, the catheterization wire was found to have an unusual intracardiac loop and was unable to be straightened within the heart. Three-dimensional transesophageal echocardiography revealed the wire was looped around a right ventricular papillary muscle. The wire was readjusted, and the fenestration was successfully closed. Three-dimensional imaging was essential in unambiguously defining the catheter course and assisting in fenestration closure.


Subject(s)
Cardiac Surgical Procedures/instrumentation , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery , Papillary Muscles/diagnostic imaging , Child , Humans , Male , Papillary Muscles/surgery , Pulmonary Atresia/complications , Tetralogy of Fallot/complications
11.
Echocardiography ; 36(10): 1884-1894, 2019 10.
Article in English | MEDLINE | ID: mdl-31541598

ABSTRACT

BACKGROUND: Three dimensional transesophageal echocardiography (3DTEE) is superior to two dimensional transesophageal echocardiography (2DTEE) as it provides all atrial septal information from a single view. AIM: To evaluate 3DTEE role in analysis of atrial septal aneurysm (ASA) and in device closure guiding. METHODS: Three dimensional transesophageal echocardiography were recorded with Vivid*E9,GE system over 14 months. ASAs were classified into 4 types (A: with PFO, B: with one ASD, C: with 2 ASDs, and D: with multiple fenestrations). Each aneurysm was assessed according to its type, shape, dimensions, orientation, aneurysmal tissue, and the surrounding rims. All patients passed to transcatheter aneurysm closure. RESULTS: A total of 26 patients with ASAs were assessed (7 imperforated aneurysms excluded). The remaining 19 patients' age was 12.84 ± 5.82years. Four patients had type A aneurysms, 6 had type B, 4 had type C, and 5 had type D. 3DTEE demonstrated oval aneurysms in 17 patients. The orientation was oblique in 8 patients, vertical in 7, and horizontal in 4. The ASAs dimensions were 23.5 ± 5.1, 23.2 ± 5.1, and 22.0 ± 4.0 mm for oblique, vertical, and horizontal axes. Percutaneous closure succeeded in 18 patients. Balloon sizing was used in 4 patients. Devices used were: In type A:PFO devices, in type B:ASO devices, in type C:two patients required two ASO devices in each patient and two patients required one cribriform device, and in type D:Cribriform devices used for three patients, PFO for one and ASO for one. LA, LUPV, and RUPV approaches were used. Aspirin was received for 6 months. CONCLUSION: Three dimensional transesophageal echocardiography helps to select aneurysms suitable for transcatheter closure, select the suitable devices, and guide the transcatheter procedure.


Subject(s)
Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Septal Occluder Device , Ultrasonography, Interventional/methods , Child , Female , Humans , Male , Reproducibility of Results
12.
Echocardiography ; 34(11): 1687-1701, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28840950

ABSTRACT

This paper provides a comprehensive overview of 3D transesophageal echocardiography still images and movies of mechanical mitral valves, mitral bioprostheses, and mitral valve repairs. Alongside these visual descriptions, the historical overview of surgical and percutaneous mitral valve intervention is described with the special emphasis on the incremental value of 3D transesophageal echocardiography (3DTEE). For each mitral valve intervention, 2D echocardiography, chest x-ray, and fluoroscopy images corresponding to 3DTEE are given. In addition, key references on echocardiographic imaging of individual valves and procedures are enumerated in accompanying figures and tables.


Subject(s)
Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Radiography/methods , Humans , Tomography, X-Ray Computed/methods
13.
Echocardiography ; 32(7): 1206-10, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25586693

ABSTRACT

Congenital absence of left atrial appendage (LAA) is an extremely rare condition and its physiological consequences are unknown. We present two cases of incidental finding of a congenitally absent LAA in a 79-year-old male who presented for routine transesophageal echocardiogram (TEE) to rule out intracardiac thrombus prior to placement of biventricular implantable cardioverter-defibrillator and a 54-year old female who presented for TEE prior to radiofrequency ablation of atrial fibrillation. Characterization of patients with such an absence is important because congenitally absent LAA may be confused with flush thrombotic occlusion of the appendage. There are very few published reports of congenital absence of LAA. To our knowledge, our report is the first to demonstrate the congenital absence of LAA by 3D transesophageal echocardiography.


Subject(s)
Atrial Appendage/diagnostic imaging , Echocardiography, Three-Dimensional , Heart Defects, Congenital/diagnostic imaging , Aged , Echocardiography, Transesophageal , Female , Humans , Incidental Findings , Male , Middle Aged
14.
J Cardiothorac Vasc Anesth ; 29(4): 889-97, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26279221

ABSTRACT

OBJECTIVE: The purpose of the study was to report the anesthetic management and immediate procedural success in the initial 20 patients undergoing percutaneous transapical mitral valve replacement. DESIGN: Retrospective review of collected data. SETTING: University-affiliated heart center. PARTICIPANTS: Twenty patients with mitral regurgitation or stenosis due to a degenerated valve or ring in the mitral position. INTERVENTIONS: TEE-guided transapical mitral valve replacement under general anesthesia and early extubation by means of an established fast-track protocol. MEASUREMENTS AND MAIN METHODS: Twenty patients underwent transapical mitral valve replacement by a beating heart procedure, avoiding cardiopulmonary bypass. The valve was either deployed due to a previously implanted bioprosthetic valve (valve-in-valve group), which degenerated, or a ring (valve-in-ring group), which predominantly showed regurgitation. There was a significant increase in the mitral valve opening area in stenosed valve pathology from 1.3-1.9 sq. cm (p = 0.004), and an increase in ejection fraction from 40% to 45% (p = 0.52). In the valve-in-ring group, valve area increased from 2.0 sq. cm to 2.6 sq. cm (p = 0.21), with an increase in ejection fraction from 30% to 35% (p = 0.18). Eighteen patients underwent successful deployment of the valve. The anesthesia duration for the procedure lasted 185.5 ± 25.4 minutes. CONCLUSIONS: There was a significant increase in opening area of the valve and improvement in ejection fraction in this patient group. TEE and fluoroscopy-guided imaging is necessary for the procedure's success and is an evolving alternative treatment for high-risk mitral valve patients who would otherwise be considered inoperable for routine surgery using sternotomy.


Subject(s)
Cardiac Catheterization/methods , Disease Management , Heart Valve Prosthesis Implantation/methods , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Aged , Aged, 80 and over , Cardiac Catheterization/trends , Cohort Studies , Female , Heart Valve Prosthesis Implantation/trends , Humans , Male , Reoperation/methods , Reoperation/trends , Retrospective Studies , Treatment Outcome , Ultrasonography
15.
J Clin Ultrasound ; 43(1): 64-7, 2015 Jan.
Article in English | MEDLINE | ID: mdl-24796869

ABSTRACT

Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis.


Subject(s)
Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis , Mitral Valve/diagnostic imaging , Thrombosis/diagnostic imaging , Aged, 80 and over , Diagnosis, Differential , Female , Humans
16.
Catheter Cardiovasc Interv ; 84(6): 868-76, 2014 Nov 15.
Article in English | MEDLINE | ID: mdl-24482054

ABSTRACT

BACKGROUND: Balloon valvuloplasty (BAV) has been considered a mandatory step before TAVI. However, it might be related to cerebrovascular microembolizations, atrioventricular conduction disturbances, and hemodynamic instability. The aim of this study is to describe transesophageal echocardiography characteristics of patients that could benefit from direct transfemoral transcatheter aortic valve implantation (TAVI) of Edwards SAPIEN XT, without previous BAV. METHODS AND RESULTS: A total of 16 patients with direct implantation of an Edwards SAPIEN XT valve are included. Preprocedural echocardiographic findings were exhaustively analyzed and described. From 32 patients elected for transfemoral TAVI with an Edwards SAPIEN XT, 16 of them (50%) were selected for direct implantation using the Edwards SAPIEN XT valve of size 23 mm (n = 5), 26 mm (n = 8), or 29 mm (n = 3). Patients selection for direct TAVI presented three echocardiographic conditions: central effective orifice, moderate to severe calcification of the aortic valve apparatus preserving leaflets movement, and symmetric distribution of calcium with absent to moderate central aortic regurgitation. Mean age was 81.4 ± 7.4, 75% female, with a mean logistic Euroscore 18.2 ± 11.2. Preprocedural mean valve gradient was 43.6 ± 16.3. Mean effective orifice area was 0.7 ± 0.2. There was no valve embolization and the success rate was 100%. Postdilation was performed in one patient (6.25%). New permanent pacing was needed in two patients (12.5%). CONCLUSIONS: TAVI without previous BAV is feasible and safe. 2D/3D TEE is an essential tool to select the patients that could benefit from this technique.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/therapy , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Calcinosis/diagnostic imaging , Calcinosis/therapy , Cardiac Catheterization , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Femoral Artery , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aged , Aged, 80 and over , Aortic Valve/physiopathology , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/therapy , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/physiopathology , Calcinosis/complications , Calcinosis/physiopathology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Cardiac Catheterization/methods , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Humans , Male , Patient Selection , Predictive Value of Tests , Prosthesis Design , Severity of Illness Index , Treatment Outcome
17.
Diseases ; 12(7)2024 Jul 12.
Article in English | MEDLINE | ID: mdl-39057122

ABSTRACT

(1) Background: Meteorological factors seem to exert various effects on human health, influencing the occurrence of diseases such as thromboembolic events and strokes. Low atmospheric pressure in summer may be associated with an increased likelihood of ischemic stroke. The aim of this study was to investigate the potential impact of meteorological conditions on left atrial appendage (LAA) thrombus formation. (2) Methods: A total of 131 patients were included, diagnosed with a first instance of thrombus via 3D transesophageal echocardiography (TEE) between February 2009 and February 2019. Months with frequent thrombus diagnoses of at least 10 thrombi per month were categorized as frequent months (F-months), while months with fewer than 10 thrombus diagnoses per month were labelled as non-frequent months (N-months). The analysis focused on differences in meteorological parameters in two-week and four-week periods before the diagnosis. (3) Results: F-months were predominantly observed in spring and summer (April, May, June, and July), as well as in February and November. During F-months, a higher absolute temperature difference, lower relative humidity, longer daily sunshine duration, and greater wind speed maximum were observed in the two- and four-week periods rather than for N-months. In the two-week period, average temperatures, equivalent temperatures, and temperature maxima were also significantly higher during F-months than N-months. (4) Conclusion: Thrombi in the left atrial appendage are more prevalent during periods characterized by high absolute temperature differences, low relative humidity, and long daily sunshine duration.

18.
Am J Cardiol ; 227: 48-56, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-39094946

ABSTRACT

Transesophageal echocardiography (TEE) plays an important role for real-time procedural guidance during surgical smyectomy (SM) for hypertrophic obstructive cardiomyopathy (HOCM). We aimed to compare (1) interventricular septum (IVS) thickness using 2- (2D) and 3-dimensional (3D) intraoperative TEE and preoperative cardiac magnetic resonance (CMR) and (2) mitral valve (MV) leaflet length using 2D, 3D TEE, automatic quantification of mitral valve (AMVQ) and preoperative CMR. We prospectively studied 50 patients with HOCM (age 59 ± 12 years, 44% men) who underwent SM during 2018 to 2019. The maximal basal, mid, and distal anteroseptum (AS) and inferoseptum (IS) were measured by multiplanar 3D reconstruction on TEE and by short-axis imaging on preoperative CMR and classified as mild (≤18 mm), moderate (18 to 25 mm), or severe (≥25 mm) groups based on AS and IS thickness on CMR. MV leaflet lengths were evaluated by preoperative CMR and intraprocedural 2D TEE, zoom 3D TEE, and AMVQ (EchoPAC, General Electric, Wisconsin). There was a moderate correlation between AS and IS thickness on 3D TEE and CMR (R2 = 0.46, p <0.01 and R2 = 0.41, p <0.01, respectively), with 3D TEE showing an average overestimation of 3.8 and 4.7 mm versus CMR. The 3D TEE overestimated 14 patients (56%) with mild thickness as moderate and 5 patients (22%) with moderate thickness as severe. Assuming 3D TEE as the gold standard, the closest correlation for anterior mitral leaflet length was with CMR (average overestimation by CMR of 0.5 mm [root mean square deviation (RMSE%) 17]), intermediate correlation with 2D TEE (average deviation of 0.6 mm [RMSE% 21]) and no correlation with AMVQ (average deviation of 0.7 mm [RMSE% 24]). In conclusion, 3D TEE overestimates IVS thickness versus CMR in patients with HOCM who underwent SM, with greater discrepancy in those with thinner IVS. There are significant differences in MV lengths measured using different imaging techniques.


Subject(s)
Cardiomyopathy, Hypertrophic , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Mitral Valve , Multimodal Imaging , Ventricular Septum , Humans , Cardiomyopathy, Hypertrophic/surgery , Cardiomyopathy, Hypertrophic/diagnostic imaging , Middle Aged , Male , Female , Prospective Studies , Ventricular Septum/diagnostic imaging , Ventricular Septum/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Echocardiography, Transesophageal/methods , Echocardiography, Three-Dimensional/methods , Aged , Magnetic Resonance Imaging, Cine/methods , Cardiac Surgical Procedures/methods , Magnetic Resonance Imaging/methods
19.
Article in English | MEDLINE | ID: mdl-38814497

ABSTRACT

A 43-year-old nigerian woman presented to cardiac intensive care unit for acute pulmonary edema with severe mitral regurgitation in a hypertrophic non obstructive cardiomyopathy for prevalent hypertrophy of posterior and lateral walls. A transesophageal echocardiography showed the isolated cleft of posterior mitral leaflet. In literature deep and multiple mitral valve clefts are described in patients with hypertrophic obstructive cardiomyopathy undergoing septal myectomy, including possible true posterior clefts, but they are not associated with the premyectomy severity of mitral regurgitation or jet direction, and do not result in surgical MV intervention. The hypertrophic cardiomyopathy is not confined to cardiac muscle but rather involves the mitral valve with structural abnormalities. In this case surgical correction of cleft was the solution for several mitral regurgitation.

20.
J Cardiothorac Vasc Anesth ; 27(4): 654-9, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23537584

ABSTRACT

OBJECTIVE: Transapical aortic valve implantation (TAVI) may lead to obstruction of coronary arteries during deployment. To prevent this, it is essential to determine the distance of the coronary ostium to the aortic annulus prior to valve placement. Multidetector computed tomography (MDCT) commonly is used to determine these measurements, but even marginal exposure to contrast agents can result in acute kidney injury in this high-risk group of multi-morbid patients. The aim of the study was to determine the feasibility of real-time 3D transesophageal echocardiography (RT 3D TEE) as the first-choice technique for noninvasive evaluation of the coronary ostium during TAVI. DESIGN: Retrospective study. SETTING: University hospital. INTERVENTIONS: Fifty patients underwent MDCT the evening before surgery. RT 3D TEE was performed intraoperatively before valve deployment. The dataset from both of these examinations was digitally stored and evaluated. MDCT was performed in nonanesthetized patients; however, in the RT 3D TEE group, general anesthesia was established. MEASUREMENTS AND MAIN RESULTS: The distances from the right coronary artery and the left coronary artery ostium were measured retrospectively. Bland-Altman Plots and linear regression analysis showed excellent correlation between the 2 methodologies; intraobserver and interobserver variance were calculated using analysis of variance. Krippendorff's α indicated excellent agreement between the 2 observers (0.96 and 0.98) as well as between RT 3D TEE and MDCT (0.97 and 0.98). CONCLUSIONS: The observations showed that RT 3D TEE reliably can measure the coronary ostium distance from the aortic annulus. It is feasible and an alternative method for evaluating these measurements and thereby preventing contrast exposure during MDCT, which may jeopardize the safety of patients with pre-existing renal disease.


Subject(s)
Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Coronary Vessels/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Heart Valve Prosthesis Implantation/methods , Aged , Aged, 80 and over , Electrocardiography , Female , Humans , Image Processing, Computer-Assisted , Linear Models , Male , Observer Variation , Software , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL