Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters

Database
Language
Publication year range
1.
EJVES Short Rep ; 42: 34-36, 2019.
Article in English | MEDLINE | ID: mdl-30931405

ABSTRACT

INTRODUCTION: Access site vascular complications in transfemoral transcatheter aortic valve implantation (TF-TAVI) are still a major concern. Recently, a novel collagen plug based closure device (Manta) was introduced. The results from the first reports on Manta are very promising, but not much is known about the long-term patency. REPORT: A case of late pseudoaneurysm after access site arterial closure with Manta in TF-TAVI is described. The patient presented five weeks after left sided TF-TAVI with pain and claudication like symptoms in the left leg. CT angiography revealed a pseudoaneurysm at the puncture site. The patient was successfully treated by vascular surgery. DISCUSSION: The results from recent peri-operative reports on the Manta vascular closure device (VCD) are promising, but not much is known about the long-term patency. In the present report a patient is described who developed a pseudoaneurysm several weeks after access site closure with Manta. To the authors' knowledge, no such late access site complications after use of the Manta VCD have been reported previously.

2.
Indian J Radiol Imaging ; 23(2): 134-8, 2013 Apr.
Article in English | MEDLINE | ID: mdl-24082477

ABSTRACT

BACKGROUND: Vascular access site management is crucial to safe, efficient, and comfortable diagnostic or interventional percutaneous procedures. The Angioseal™ vascular closure device has been shown to be safe and effective in reducing the time to hemostasis following angiographic or interventional procedures. Relatively few studies have been conducted in the UK to assess the safety and efficacy of the device in a local setting. MATERIALS AND METHODS: Data were retrospectively reviewed on 147 patients who underwent either diagnostic angiography or percutaneous interventional procedures from January 2008 to October 2009, and who had the femoral access site closed by 6F VIP Angioseal. A total of 147 patients (F: 49, M: 98), including 80 right femoral punctures, 57 left femoral punctures, and 10 bilateral punctures were reviewed using radiological reports and patients' clinical data. Data on antiplatelet and anticoagulant therapy were recorded. All procedures were carried out by two interventional radiologists at a single institution, under similar operating conditions. RESULTS: There were a total of six complications (4.47%), of which one was a major complication (0.75%), i.e., retroperitoneal bleed. There were five minor complications (3.73%), which included device deployment failure (2), device malfunction (2), and a superficial hematoma (>6 cm). Total complications were 6 out of 157 (3.8%) [95% CI = 0.8-6.8%)]. Successful hemostasis was achieved in less than 5 min in over 97% of patients. Successful device deployment was seen in over 98% of cases. CONCLUSION: We conclude that in our experience, the Angioseal vascular closure device is a safe and efficient means of achieving hemostasis post antegrade or retrograde puncture for diagnostic and percutaneous intervention procedures.

SELECTION OF CITATIONS
SEARCH DETAIL