1.
Psychophysiology ; 61(4): e14480, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37971153

ABSTRACT

In this study, we conducted research on a deep learning-based blood pressure (BP) estimation model suitable for wearable environments. To measure BP while wearing a wearable watch, it needs to be considered that computing power for signal processing is limited and the input signals are subject to noise interference. Therefore, we employed a convolutional neural network (CNN) as the BP estimation model and utilized time-series electrocardiogram (ECG) and photoplethysmogram (PPG) signals, which are quantifiable in a wearable context. We generated periodic input signals and used differential and thresholding methods to decrease noise in the preprocessing step. We then applied a max-pooling technique with filter sizes of 2 × 1 and 5 × 1 within a 3-layer convolutional neural network to estimate BP. Our method was trained, validated, and tested using 2.4 million data samples from 49 patients in the intensive care unit. These samples, totaling 3.1 GB were obtained from the publicly accessible MIMIC database. As a result of a test with 480,000 data samples, the average root mean square error in BP estimation was 3.41, 5.80, and 2.78 mm Hg in the prediction of pulse pressure, systolic BP (SBP), and diastolic BP (DBP), respectively. The cumulative error percentage less than 5 mm Hg was 68% and 93% for SBP and DBP, respectively. In addition, the cumulative error percentage less than 15 mm Hg was 98% and 99% for SBP and DBP. Subsequently, we evaluated the impact of changes in input signal length (1 cycle vs. 30 s) and the introduction of noise on BP estimation results. The experimental results revealed that the length of the input signal did not significantly affect the performance of CNN-based analysis. When estimating BP using noise-added ECG signals, the mean absolute error (MAE) for SBP and DBP was 9.72 and 6.67 mm Hg, respectively. Meanwhile, when using noise-added PPG signals, the MAE for SBP and DBP was 26.85 and 14.00 mm Hg, respectively. Therefore, this study confirmed that using ECG signals rather than PPG signals is advantageous for noise reduction in a wearable environment. Besides, short sampling frames without calibration can be effective as input signals. Furthermore, it demonstrated that using a model suitable for information extraction rather than a specialized deep learning model for sequential data can yield satisfactory results in BP estimation.


Subject(s)
Blood Pressure Determination , Photoplethysmography , Humans , Blood Pressure/physiology , Blood Pressure Determination/methods , Calibration , Photoplethysmography/methods , Neural Networks, Computer
2.
J Biomed Inform ; 156: 104680, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38914411

ABSTRACT

OBJECTIVE: Failure to receive prompt blood transfusion leads to severe complications if massive bleeding occurs during surgery. For the timely preparation of blood products, predicting the possibility of massive transfusion (MT) is essential to decrease morbidity and mortality. This study aimed to develop a model for predicting MT 10 min in advance using non-invasive bio-signal waveforms that change in real-time. METHODS: In this retrospective study, we developed a deep learning-based algorithm (DLA) to predict intraoperative MT within 10 min. MT was defined as the transfusion of 3 or more units of red blood cells within an hour. The datasets consisted of 18,135 patients who underwent surgery at Seoul National University Hospital (SNUH) for model development and internal validation and 621 patients who underwent surgery at the Boramae Medical Center (BMC) for external validation. We constructed the DLA by using features extracted from plethysmography (collected at 500 Hz) and hematocrit measured during surgery. RESULTS: Among 18,135 patients in SNUH and 621 patients in BMC, 265 patients (1.46%) and 14 patients (2.25%) received MT during surgery, respectively. The area under the receiver operating characteristic curve (AUROC) of DLA predicting intraoperative MT before 10 min was 0.962 (95% confidence interval [CI], 0.948-0.974) in internal validation and 0.922 (95% CI, 0.882-0.959) in external validation, respectively. CONCLUSION: The DLA can successfully predict intraoperative MT using non-invasive bio-signal waveforms.


Subject(s)
Blood Transfusion , Humans , Female , Male , Retrospective Studies , Middle Aged , Algorithms , Aged , Monitoring, Intraoperative/methods , Hemodynamic Monitoring/methods , Adult , Deep Learning , ROC Curve , Hemodynamics , Hematocrit , Blood Loss, Surgical
3.
Sensors (Basel) ; 24(7)2024 Mar 31.
Article in English | MEDLINE | ID: mdl-38610459

ABSTRACT

Heart failure is a prevalent cardiovascular condition with significant health implications, necessitating effective diagnostic strategies for timely intervention. This study explores the potential of continuous monitoring of non-invasive signals, specifically integrating photoplethysmogram (PPG) and electrocardiogram (ECG), for enhancing early detection and diagnosis of heart failure. Leveraging a dataset from the MIMIC-III database, encompassing 682 heart failure patients and 954 controls, our approach focuses on continuous, non-invasive monitoring. Key features, including the QRS interval, RR interval, augmentation index, heart rate, systolic pressure, diastolic pressure, and peak-to-peak amplitude, were carefully selected for their clinical relevance and ability to capture cardiovascular dynamics. This feature selection not only highlighted important physiological indicators but also helped reduce computational complexity and the risk of overfitting in machine learning models. The use of these features in training machine learning algorithms led to a model with impressive accuracy (98%), sensitivity (97.60%), specificity (96.90%), and precision (97.20%). Our integrated approach, combining PPG and ECG signals, demonstrates superior performance compared to single-signal strategies, emphasizing its potential in early and precise heart failure diagnosis. The study also highlights the importance of continuous monitoring with wearable technology, suggesting a significant stride forward in non-invasive cardiovascular health assessment. The proposed approach holds promise for implementation in hardware systems to enable continuous monitoring, aiding in early detection and prevention of critical health conditions.


Subject(s)
Cardiovascular Diseases , Heart Failure , Humans , Heart Failure/diagnosis , Electrocardiography , Algorithms , Machine Learning
4.
Sensors (Basel) ; 24(12)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38931763

ABSTRACT

Respiratory rate (RR) is a vital indicator for assessing the bodily functions and health status of patients. RR is a prominent parameter in the field of biomedical signal processing and is strongly associated with other vital signs such as blood pressure, heart rate, and heart rate variability. Various physiological signals, such as photoplethysmogram (PPG) signals, are used to extract respiratory information. RR is also estimated by detecting peak patterns and cycles in the signals through signal processing and deep-learning approaches. In this study, we propose an end-to-end RR estimation approach based on a third-generation artificial neural network model-spiking neural network. The proposed model employs PPG segments as inputs, and directly converts them into sequential spike events. This design aims to reduce information loss during the conversion of the input data into spike events. In addition, we use feedback-based integrate-and-fire neurons as the activation functions, which effectively transmit temporal information. The network is evaluated using the BIDMC respiratory dataset with three different window sizes (16, 32, and 64 s). The proposed model achieves mean absolute errors of 1.37 ± 0.04, 1.23 ± 0.03, and 1.15 ± 0.07 for the 16, 32, and 64 s window sizes, respectively. Furthermore, it demonstrates superior energy efficiency compared with other deep learning models. This study demonstrates the potential of the spiking neural networks for RR monitoring, offering a novel approach for RR estimation from the PPG signal.


Subject(s)
Neural Networks, Computer , Photoplethysmography , Respiratory Rate , Signal Processing, Computer-Assisted , Humans , Respiratory Rate/physiology , Photoplethysmography/methods , Heart Rate/physiology , Algorithms , Deep Learning
5.
Sensors (Basel) ; 24(11)2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38894487

ABSTRACT

Comprehending the regulatory mechanisms influencing blood pressure control is pivotal for continuous monitoring of this parameter. Implementing a personalized machine learning model, utilizing data-driven features, presents an opportunity to facilitate tracking blood pressure fluctuations in various conditions. In this work, data-driven photoplethysmograph features extracted from the brachial and digital arteries of 28 healthy subjects were used to feed a random forest classifier in an attempt to develop a system capable of tracking blood pressure. We evaluated the behavior of this latter classifier according to the different sizes of the training set and degrees of personalization used. Aggregated accuracy, precision, recall, and F1-score were equal to 95.1%, 95.2%, 95%, and 95.4% when 30% of a target subject's pulse waveforms were combined with five randomly selected source subjects available in the dataset. Experimental findings illustrated that incorporating a pre-training stage with data from different subjects made it viable to discern morphological distinctions in beat-to-beat pulse waveforms under conditions of cognitive or physical workload.


Subject(s)
Blood Pressure , Machine Learning , Photoplethysmography , Humans , Blood Pressure/physiology , Male , Photoplethysmography/methods , Female , Adult , Cognition/physiology , Algorithms , Workload , Blood Pressure Determination/methods , Young Adult
6.
BMC Med Inform Decis Mak ; 23(1): 131, 2023 07 21.
Article in English | MEDLINE | ID: mdl-37480040

ABSTRACT

BACKGROUND: Monitoring blood pressure and peripheral capillary oxygen saturation plays a crucial role in healthcare management for patients with chronic diseases, especially hypertension and vascular disease. However, current blood pressure measurement methods have intrinsic limitations; for instance, arterial blood pressure is measured by inserting a catheter in the artery causing discomfort and infection. METHOD: Photoplethysmogram (PPG) signals can be collected via non-invasive devices, and therefore have stimulated researchers' interest in exploring blood pressure estimation using machine learning and PPG signals as a non-invasive alternative. In this paper, we propose a Transformer-based deep learning architecture that utilizes PPG signals to conduct a personalized estimation of arterial systolic blood pressure, arterial diastolic blood pressure, and oxygen saturation. RESULTS: The proposed method was evaluated with a subset of 1,732 subjects from the publicly available ICU dataset MIMIC III. The mean absolute error is 2.52 ± 2.43 mmHg for systolic blood pressure, 1.37 ± 1.89 mmHg for diastolic blood pressure, and 0.58 ± 0.79% for oxygen saturation, which satisfies the requirements of the Association of Advancement of Medical Instrumentation standard and achieve grades A for the British Hypertension Society standard. CONCLUSIONS: The results indicate that our model meets clinical standards and could potentially boost the accuracy of blood pressure and oxygen saturation measurement to deliver high-quality healthcare.


Subject(s)
Deep Learning , Hypertension , Humans , Arterial Pressure , Blood Pressure/physiology , Photoplethysmography/methods , Arteries , Hypertension/diagnosis
7.
Sensors (Basel) ; 23(12)2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37420772

ABSTRACT

Photoplethysmography (PPG) is used to measure blood volume changes in the microvascular bed of tissue. Information about these changes along time can be used for estimation of various physiological parameters, such as heart rate variability, arterial stiffness, and blood pressure, to name a few. As a result, PPG has become a popular biological modality and is widely used in wearable health devices. However, accurate measurement of various physiological parameters requires good-quality PPG signals. Therefore, various signal quality indexes (SQIs) for PPG signals have been proposed. These metrics have usually been based on statistical, frequency, and/or template analyses. The modulation spectrogram representation, however, captures the second-order periodicities of a signal and has been shown to provide useful quality cues for electrocardiograms and speech signals. In this work, we propose a new PPG quality metric based on properties of the modulation spectrum. The proposed metric is tested using data collected from subjects while they performed various activity tasks contaminating the PPG signals. Experiments on this multi-wavelength PPG dataset show the combination of proposed and benchmark measures significantly outperforming several benchmark SQIs with improvements of 21.3% BACC (balanced accuracy) for green, 21.6% BACC for red, and 19.0% BACC for infrared wavelengths, respectively, for PPG quality detection tasks. The proposed metrics also generalize for cross-wavelength PPG quality detection tasks.


Subject(s)
Photoplethysmography , Wearable Electronic Devices , Humans , Heart Rate/physiology , Blood Pressure , Blood Volume , Signal Processing, Computer-Assisted , Algorithms
8.
Sensors (Basel) ; 23(10)2023 May 10.
Article in English | MEDLINE | ID: mdl-37430548

ABSTRACT

In the head-mounted display environment for experiencing metaverse or virtual reality, conventional input devices cannot be used, so a new type of nonintrusive and continuous biometric authentication technology is required. Since the wrist wearable device is equipped with a photoplethysmogram sensor, it is very suitable for use for nonintrusive and continuous biometric authentication purposes. In this study, we propose a one-dimensional Siamese network biometric identification model using a photoplethysmogram. To maintain the unique characteristics of each person and reduce noise in preprocessing, we adopted a multicycle averaging method without using a bandpass or low-pass filter. In addition, to verify the effectiveness of the multicycle averaging method, the number of cycles was changed and the results were compared. Genuine and impostor data were used to verify the biometric identification. We used the one-dimensional Siamese network to verify the similarity between the classes and found that the method with five overlapping cycles was the most effective. Tests were conducted on the overlapping data of five single-cycle signals and excellent identification results were observed, with an AUC score of 0.988 and an accuracy of 0.9723. Thus, the proposed biometric identification model is time-efficient and shows excellent security performance, even in devices with limited computational capabilities, such as wearable devices. Consequently, our proposed method has the following advantages compared with previous works. First, the effect of noise reduction and information preservation through multicycle averaging was experimentally verified by varying the number of photoplethysmogram cycles. Second, by analyzing authentication performance through genuine and impostor matching analysis based on a one-dimensional Siamese network, the accuracy that is not affected by the number of enrolled subjects was derived.


Subject(s)
Biometric Identification , Photoplethysmography , Humans , Cytoplasm , Smart Glasses
9.
Sensors (Basel) ; 23(5)2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36904628

ABSTRACT

A sudden cardiac event in patients with heart disease can lead to a heart attack in extreme cases. Therefore, prompt interventions for the particular heart situation and periodic monitoring are critical. This study focuses on a heart sound analysis method that can be monitored daily using multimodal signals acquired with wearable devices. The dual deterministic model-based heart sound analysis is designed in a parallel structure that uses two bio-signals (PCG and PPG signals) related to the heartbeat, enabling more accurate heart sound identification. The experimental results show promising performance of the proposed Model III (DDM-HSA with window and envelope filter), which had the highest performance, and S1 and S2 showed average accuracy (unit: %) of 95.39 (±2.14) and 92.55 (±3.74), respectively. The findings of this study are anticipated to provide improved technology to detect heart sounds and analyze cardiac activities using only bio-signals that can be measured using wearable devices in a mobile environment.


Subject(s)
Heart Diseases , Heart Sounds , Humans , Signal Processing, Computer-Assisted , Heart , Heart Rate , Algorithms
10.
Sensors (Basel) ; 23(5)2023 Feb 25.
Article in English | MEDLINE | ID: mdl-36904763

ABSTRACT

The early identification of microvascular changes in patients with Coronavirus Disease 2019 (COVID-19) may offer an important clinical opportunity. This study aimed to define a method, based on deep learning approaches, for the identification of COVID-19 patients from the analysis of the raw PPG signal, acquired with a pulse oximeter. To develop the method, we acquired the PPG signal of 93 COVID-19 patients and 90 healthy control subjects using a finger pulse oximeter. To select the good quality portions of the signal, we developed a template-matching method that excludes samples corrupted by noise or motion artefacts. These samples were subsequently used to develop a custom convolutional neural network model. The model accepts PPG signal segments as input and performs a binary classification between COVID-19 and control samples. The proposed model showed good performance in identifying COVID-19 patients, achieving 83.86% accuracy and 84.30% sensitivity (hold-out validation) on test data. The obtained results indicate that photoplethysmography may be a useful tool for microcirculation assessment and early recognition of SARS-CoV-2-induced microvascular changes. In addition, such a noninvasive and low-cost method is well suited for the development of a user-friendly system, potentially applicable even in resource-limited healthcare settings.


Subject(s)
COVID-19 , Photoplethysmography , Humans , Photoplethysmography/methods , SARS-CoV-2 , Oximetry/methods , Oxygen , Neural Networks, Computer , Signal Processing, Computer-Assisted , Heart Rate
11.
Sensors (Basel) ; 23(8)2023 Apr 21.
Article in English | MEDLINE | ID: mdl-37112490

ABSTRACT

Traditional cuff-based sphygmomanometers for measuring blood pressure can be uncomfortable and particularly unsuitable to use during sleep. A proposed alternative method uses dynamic changes in the pulse waveform over short intervals and replaces calibration with information from photoplethysmogram (PPG) morphology to provide a calibration-free approach using a single sensor. Results from 30 patients show a high correlation of 73.64% for systolic blood pressure (SBP) and 77.72% for diastolic blood pressure (DBP) between blood pressure estimated with the PPG morphology features and the calibration method. This suggests that the PPG morphology features could replace the calibration stage for a calibration-free method with similar accuracy. Applying the proposed methodology on 200 patients and testing on 25 new patients resulted in a mean error (ME) of -0.31 mmHg, a standard deviation of error (SDE) of 4.89 mmHg, a mean absolute error (MAE) of 3.32 mmHg for DBP and an ME of -4.02 mmHg, an SDE of 10.40 mmHg, and an MAE of 7.41 mmHg for SBP. These results support the potential for using a PPG signal for calibration-free cuffless blood pressure estimation and improving accuracy by adding information from cardiovascular dynamics to different methods in the cuffless blood pressure monitoring field.


Subject(s)
Photoplethysmography , Pulse Wave Analysis , Humans , Blood Pressure/physiology , Photoplethysmography/methods , Pulse Wave Analysis/methods , Blood Pressure Determination/methods , Sphygmomanometers
12.
Sensors (Basel) ; 23(13)2023 Jul 05.
Article in English | MEDLINE | ID: mdl-37448029

ABSTRACT

A new method for accurately estimating heart rates based on a single photoplethysmography (PPG) signal and accelerations is proposed in this study, considering motion artifacts due to subjects' hand motions and walking. The method comprises two sub-algorithms: pre-quality checking and motion artifact removal (MAR) via Hankel decomposition. PPGs and accelerations were collected using a wearable device equipped with a PPG sensor patch and a 3-axis accelerometer. The motion artifacts caused by hand movements and walking were effectively mitigated by the two aforementioned sub-algorithms. The first sub-algorithm utilized a new quality-assessment criterion to identify highly noise-contaminated PPG signals and exclude them from subsequent processing. The second sub-algorithm employed the Hankel matrix and singular value decomposition (SVD) to effectively identify, decompose, and remove motion artifacts. Experimental data collected during hand-moving and walking were considered for evaluation. The performance of the proposed algorithms was assessed using the datasets from the IEEE Signal Processing Cup 2015. The obtained results demonstrated an average error of merely 0.7345 ± 8.1129 beats per minute (bpm) and a mean absolute error of 1.86 bpm for walking, making it the second most accurate method to date that employs a single PPG and a 3-axis accelerometer. The proposed method also achieved the best accuracy of 3.78 bpm in mean absolute errors among all previously reported studies for hand-moving scenarios.


Subject(s)
Exercise , Photoplethysmography , Humans , Heart Rate/physiology , Photoplethysmography/methods , Exercise/physiology , Signal Processing, Computer-Assisted , Algorithms , Artifacts
13.
Sensors (Basel) ; 23(17)2023 Aug 24.
Article in English | MEDLINE | ID: mdl-37687854

ABSTRACT

Accurately measuring blood pressure (BP) is essential for maintaining physiological health, which is commonly achieved using cuff-based sphygmomanometers. Several attempts have been made to develop cuffless sphygmomanometers. To increase their accuracy and long-term variability, machine learning methods can be applied for analyzing photoplethysmogram (PPG) signals. Here, we propose a method to estimate the BP during exercise using a cuffless device. The BP estimation process involved preprocessing signals, feature extraction, and machine learning techniques. To ensure the reliability of the signals extracted from the PPG, we employed the skewness signal quality index and the RReliefF algorithm for signal selection. Thereafter, the BP was estimated using the long short-term memory (LSTM)-based neural network. Seventeen young adult males participated in the experiments, undergoing a structured protocol composed of rest, exercise, and recovery for 20 min. Compared to the BP measured using a non-invasive voltage clamp-type continuous sphygmomanometer, that estimated by the proposed method exhibited a mean error of 0.32 ± 7.76 mmHg, which is equivalent to the accuracy of a cuff-based sphygmomanometer per regulatory standards. By enhancing patient comfort and improving healthcare outcomes, the proposed approach can revolutionize BP monitoring in various settings, including clinical, home, and sports environments.


Subject(s)
Blood Pressure Determination , Exercise , Male , Young Adult , Humans , Blood Pressure , Reproducibility of Results , Blood Pressure Monitors
14.
Sensors (Basel) ; 23(4)2023 Feb 16.
Article in English | MEDLINE | ID: mdl-36850820

ABSTRACT

Intervals of low-quality photoplethysmogram (PPG) signals might lead to significant inaccuracies in estimation of pulse arrival time (PAT) during polysomnography (PSG) studies. While PSG is considered to be a "gold standard" test for diagnosing obstructive sleep apnea (OSA), it also enables tracking apnea-related nocturnal blood pressure fluctuations correlated with PAT. Since the electrocardiogram (ECG) is recorded synchronously with the PPG during PSG, it makes sense to use the ECG signal for PPG signal-quality assessment. (1) Objective: to develop a PPG signal-quality assessment algorithm for robust PAT estimation, and investigate the influence of signal quality on PAT during various sleep stages and events such as OSA. (2) Approach: the proposed algorithm uses R and T waves from the ECG to determine approximate locations of PPG pulse onsets. The MESA database of 2055 PSG recordings was used for this study. (3) Results: the proportions of high-quality PPG were significantly lower in apnea-related oxygen desaturation (matched-pairs rc = 0.88 and rc = 0.97, compared to OSA and hypopnea, respectively, when p < 0.001) and arousal (rc = 0.93 and rc = 0.98, when p < 0.001) than in apnea events. The significantly large effect size of interquartile ranges of PAT distributions was between low- and high-quality PPG (p < 0.001, rc = 0.98), and regular and irregular pulse waves (p < 0.001, rc = 0.74), whereas a lower quality of the PPG signal was found to be associated with a higher interquartile range of PAT across all subjects. Suggested PPG signal quality-based PAT evaluation reduced deviations (e.g., rc = 0.97, rc = 0.97, rc = 0.99 in hypopnea, oxygen desaturation, and arousal stages, respectively, when p < 0.001) and allowed obtaining statistically larger differences between different sleep stages and events. (4) Significance: the implemented algorithm has the potential to increase the robustness of PAT estimation in PSG studies related to nocturnal blood pressure monitoring.


Subject(s)
Photoplethysmography , Sleep Apnea, Obstructive , Humans , Polysomnography , Heart Rate , Sleep Apnea, Obstructive/diagnosis , Oxygen
15.
Proc IEEE Inst Electr Electron Eng ; 110(3): 355-381, 2022 Mar 11.
Article in English | MEDLINE | ID: mdl-35356509

ABSTRACT

Smart wearables provide an opportunity to monitor health in daily life and are emerging as potential tools for detecting cardiovascular disease (CVD). Wearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram signal, an optical measure of the arterial pulse wave that is strongly influenced by the heart and blood vessels. In this survey, we summarize the fundamentals of wearable photoplethysmography and its analysis, identify its potential clinical applications, and outline pressing directions for future research in order to realize its full potential for tackling CVD.

16.
Adv Exp Med Biol ; 1395: 289-293, 2022.
Article in English | MEDLINE | ID: mdl-36527651

ABSTRACT

A non-invasive, contactless, inexpensive and easy-to-operate perfusion imaging method using a consumer-grade mobile camera (iPhone 8) developed in our group can visualise blood flow in tissue. METHODS: Ischemia was induced in one hand using a blood pressure cuff inflated over the systolic blood pressure to stop the blood flow. Using an iPhone, data was collected from 5 subjects, beginning with no occlusion (a baseline), followed by one hand occluded, and then release of the occlusion to restore blood circulation. This protocol was repeated for each hand for a total of 10 videos. The data were analysed to extract the oscillating and quasi-constant components of the photoplethysmogram signal representing blood flow. In addition, we introduced a scoring parameter to reflect perfusion (i.e., perfusion score). RESULTS: The proposed perfusion score was used to create a pseudo colour map of perfusion across the protocol, demonstrating the ability to detect ischemia caused by occlusion. The difference in perfusion score was statistically significant between ischemia and baseline/recovery. CONCLUSIONS: Pilot results on healthy volunteers demonstrate the feasibility of perfusion imaging using a consumer-grade camera. A further developed method can be used to assess the viability of transplanted tissue.


Subject(s)
Blood Pressure Determination , Perfusion Imaging , Humans , Feasibility Studies , Perfusion Imaging/methods , Ischemia/diagnostic imaging , Hemodynamics , Perfusion
17.
Sensors (Basel) ; 22(17)2022 Aug 27.
Article in English | MEDLINE | ID: mdl-36080924

ABSTRACT

Heart sounds and heart rate (pulse) are the most common physiological signals used in the diagnosis of cardiovascular diseases. Measuring these signals using a device and analyzing their interrelationships simultaneously can improve the accuracy of existing methods and propose new approaches for the diagnosis of cardiovascular diseases. In this study, we have presented a novel smart stethoscope based on multimodal physiological signal measurement technology for personal cardiovascular health monitoring. The proposed device is designed in the shape of a compact personal computer mouse for easy grasping and attachment to the surface of the chest using only one hand. A digital microphone and photoplehysmogram sensor are installed on the bottom and top surfaces of the device, respectively, to measure heart sound and pulse from the user's chest and finger simultaneously. In addition, a high-performance Bluetooth Low Energy System-on-Chip ARM microprocessor is used for pre-processing of measured data and communication with the smartphone. The prototype is assembled on a manufactured printed circuit board and 3D-printed shell to conduct an in vivo experiment to test the performance of physiological signal measurement and usability by observing users' muscle fatigue variation.


Subject(s)
Cardiovascular Diseases , Heart Sounds , Stethoscopes , Heart Sounds/physiology , Humans , Signal Processing, Computer-Assisted , Technology
18.
Sensors (Basel) ; 22(11)2022 May 26.
Article in English | MEDLINE | ID: mdl-35684656

ABSTRACT

This work presents an overview of the main strategies that have been proposed for non-invasive monitoring of heart rate (HR) in extramural and home settings. We discuss three categories of sensing according to what physiological effect is used to measure the pulsatile activity of the heart, and we focus on an illustrative sensing modality for each of them. Therefore, electrocardiography, photoplethysmography, and mechanocardiography are presented as illustrative modalities to sense electrical activity, mechanical activity, and the peripheral effect of heart activity. In this paper, we describe the physical principles underlying the three categories and the characteristics of the different types of sensors that belong to each class, and we touch upon the most used software strategies that are currently adopted to effectively and reliably extract HR. In addition, we investigate the strengths and weaknesses of each category linked to the different applications in order to provide the reader with guidelines for selecting the most suitable solution according to the requirements and constraints of the application.


Subject(s)
Electrocardiography , Photoplethysmography , Heart Rate/physiology , Monitoring, Physiologic
19.
Sensors (Basel) ; 22(14)2022 Jul 09.
Article in English | MEDLINE | ID: mdl-35890834

ABSTRACT

Photoplethysmography is a widely used technique to noninvasively assess heart rate, blood pressure, and oxygen saturation. This technique has considerable potential for further applications-for example, in the field of physiological and mental health monitoring. However, advanced applications of photoplethysmography have been hampered by the lack of accurate and reliable methods to analyze the characteristics of the complex nonlinear dynamics of photoplethysmograms. Methods of nonlinear time series analysis may be used to estimate the dynamical characteristics of the photoplethysmogram, but they are highly influenced by the length of the time series, which is often limited in practical photoplethysmography applications. The aim of this study was to evaluate the error in the estimation of the dynamical characteristics of the photoplethysmogram associated with the limited length of the time series. The dynamical properties were evaluated using recurrence quantification analysis, and the estimation error was computed as a function of the length of the time series. Results demonstrated that properties such as determinism and entropy can be estimated with an error lower than 1% even for short photoplethysmogram recordings. Additionally, the lower limit for the time series length to estimate the average prediction time was computed.


Subject(s)
Photoplethysmography , Signal Processing, Computer-Assisted , Algorithms , Blood Pressure/physiology , Heart Rate/physiology , Photoplethysmography/methods
20.
Sensors (Basel) ; 22(3)2022 Jan 25.
Article in English | MEDLINE | ID: mdl-35161664

ABSTRACT

Cardiovascular diseases are the most common causes of death around the world. To detect and treat heart-related diseases, continuous blood pressure (BP) monitoring along with many other parameters are required. Several invasive and non-invasive methods have been developed for this purpose. Most existing methods used in hospitals for continuous monitoring of BP are invasive. On the contrary, cuff-based BP monitoring methods, which can predict systolic blood pressure (SBP) and diastolic blood pressure (DBP), cannot be used for continuous monitoring. Several studies attempted to predict BP from non-invasively collectible signals such as photoplethysmograms (PPG) and electrocardiograms (ECG), which can be used for continuous monitoring. In this study, we explored the applicability of autoencoders in predicting BP from PPG and ECG signals. The investigation was carried out on 12,000 instances of 942 patients of the MIMIC-II dataset, and it was found that a very shallow, one-dimensional autoencoder can extract the relevant features to predict the SBP and DBP with state-of-the-art performance on a very large dataset. An independent test set from a portion of the MIMIC-II dataset provided a mean absolute error (MAE) of 2.333 and 0.713 for SBP and DBP, respectively. On an external dataset of 40 subjects, the model trained on the MIMIC-II dataset provided an MAE of 2.728 and 1.166 for SBP and DBP, respectively. For both the cases, the results met British Hypertension Society (BHS) Grade A and surpassed the studies from the current literature.


Subject(s)
Hypertension , Photoplethysmography , Blood Pressure , Blood Pressure Determination , Electrocardiography , Humans , Hypertension/diagnosis