Int Endod J ; 54(7): 1166-1174, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33556198

ABSTRACT

AIM: To evaluate in a laboratory setting the performance of two reciprocating glide path systems, WaveOne Gold Glider (WO) and R-Pilot (RP), to create a glide path in mesial root canals of mandibular molars and to assess the torsional resistance of instruments after performing the glide path. METHODOLOGY: A total of 60 mesial root canals of extracted human mandibular molars were divided into two groups (n = 30) according to the glide path system to be used. The data from the volume of each canal, acquired by microcomputed tomography (micro-CT), were validated statistically for the anatomical pairing of the groups. Preparation time, frequency in gaining apical patency, plastic deformation rate of instruments, and canal transportation and centring ability were recorded and compared statistically. The torsional fatigue of the instruments after use was also evaluated. Data were analysed using Fisher's exact test and Mann-Whitney U-test with a 5% significance level. RESULTS: No significant differences were found between groups regarding the time required to perform the glide path, the frequency distributions of the canals classified as patent and the instruments with plastic deformation after use (P > 0.05). No significant differences were found between groups regarding the degree of canal transportation and centring ability at the cervical, middle and apical thirds (P > 0.05). The RP groups had significantly greater maximum torsional strength values compared with the WO groups (P < 0.05). The used WO group had greater angular deflection to fracture when compared to the new WO group (P < 0.05). A significant difference was also found in the percentage of loss of angular deflection in a comparison of the WO group with the RP group (P < 0.05). CONCLUSIONS: The WO and RP instruments performed the same in terms of preparation time, plastic deformation, gaining apical patency, degree of canal transportation and centring ability. The RP instruments had greater torsional strength, less angular deflection and lower percentage of loss in angular deflection than the WO. The used WO group had the greatest angular deflection values.


Subject(s)
Dental Pulp Cavity , Laboratories , Dental Instruments , Dental Pulp Cavity/diagnostic imaging , Equipment Design , Humans , Molar/diagnostic imaging , Molar/surgery , Root Canal Preparation , Statistics, Nonparametric , Titanium , X-Ray Microtomography
2.
J Contemp Dent Pract ; 22(4): 361-364, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34267004

ABSTRACT

AIM AND OBJECTIVE: The present study aims to evaluate the difference in torsional resistance of two reciprocating nickel-titanium (Ni-Ti) rotary files: WaveOne Gold and EdgeOne Fire. MATERIALS AND METHODS: A total of 40 nickel-titanium rotary instruments (n = 40): 20 WaveOne Gold Small (WOGS) and 20 EdgeOne Fire Small (EOFS) were divided into two groups. Each instrument was tested using a torsional resistance device already validated in previous studies to evaluate and compare torsional resistance. The static torsional test was implemented by blocking each instrument at 3 mm from the tip and rotating it until fracture with a reciprocating motion. Torque to fracture (TtF) and fragment length (FL) were measured and statistically analyzed. RESULTS: Statistical analysis of TtF found significant differences between the two groups (p<0.05). The EOFS showed higher TtF if compared to WOGS, with a mean value and a standard deviation of 3.05 ± 0.07 (N cm) against 2.97 ± 0.08 (N cm). Data for FL showed no significant differences (p>0.05) between the two groups. CONCLUSION: According to the results of this study, it is reasonable to assert that EOFS instruments showed a higher torsional resistance if compared to the WOGS. CLINICAL SIGNIFICANCE: As evidenced by this study, EOFS should be considered as a safer solution, in terms of torsional resistance, if compared to WOGS, reducing the risk of intracanal separation due to excessive torsional load.


Subject(s)
Nickel , Titanium , Dental Alloys , Dental Instruments , Equipment Design , Hot Temperature , Materials Testing , Root Canal Preparation , Torsion, Mechanical
3.
Int Endod J ; 53(12): 1689-1695, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32767775

ABSTRACT

AIM: To evaluate the bending, buckling and torsional resistance of ProGlider (PG) (Dentsply Sirona, Ballaigues, Switzerland), R-Pilot (RP) (VDW, Munich, Germany) and WaveOne Gold Glider (WOGG) (Dentsply Sirona). METHODOLOGY: Ninety instruments were used: 30 PG (size 0.16, .02v taper), 30 RP (size 0.125, .04 taper) and 30 WOGG (size 0.15, .02v taper). The bending resistance test was performed on 10 randomly selected instruments of each system according to ISO 3630-1 specifications. For the buckling resistance test, a loading was applied in the axial direction of each instrument using a universal test machine, with a 20 N cell and 15 mm min-1 speed, in the axial direction. When a lateral elastic displacement of 1 mm occurred, the force was registered. The torsional resistance test was performed according to ISO 3630-1 specifications. Statistical analysis was performed using one-way anova and post hoc Student-Newman-Keuls test (P < 0.05). RESULTS: WOGG had the lowest bending resistance, whilst RP had the highest bending resistance (P < 0.05). RP also had the highest buckling resistance, and WOGG had the lowest (P < 0.05). PG had intermediate results regarding bending and buckling resistance, with significant differences to RP and WOGG (P < 0.05). RP had the highest torsional strength and the lowest angular deflection when compared to PG and WOGG (P < 0.05). No differences in the torsional strength and angular deflection were observed between WOGG and PG (P> 0.05). CONCLUSION: The glide path instruments had different behaviours in term of bending, buckling and torsional resistance.


Subject(s)
Dental Instruments , Mechanical Phenomena , Dental Alloys , Equipment Design , Germany , Gold , Humans , Materials Testing , Root Canal Preparation , Titanium , Torsion, Mechanical
4.
Int Endod J ; 52(11): 1645-1651, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31132156

ABSTRACT

AIM: To evaluate the influence of controlled memory (CM) thermal treatment on the torsional resistance and surface roughness of nickel-titanium instruments with identical geometric and dimensional characteristics. The influence of environmental temperature on torsional resistance was also evaluated. METHODOLOGY: A sample of 25 conventional NiTi alloy and 25 CM thermal-treated NiTi instruments, with an identical geometric design and a nominal size of 0.25 mm at D0 and a nominal taper of .06 mm mm-1 were selected. The torsional strength and the angle of rotation of the instruments were tested following ISO 3630-1 at two temperatures: 21 and 35 °C. The fracture surfaces of all tested instruments were verified with a scanning electron microscope. The surface roughness of the blades of conventional NiTi alloy and CM wire files was evaluated by using a New View 7100 Profilometer. Statistical analysis was performed using Student's t-test and paired t-test to analyse the torsional resistance and surface roughness at a significance level of P < 0.05. RESULTS: The torsional strength of thermally-treated instruments was significantly lower than nontreated instruments (P < 0.05). However, thermally-treated instruments had significantly greater angular rotation to fracture than nontreated instruments (P < 0.05). Temperature did not influence the torsional strength (P > 0.05) and the angular rotation (P > 0.05) of the instruments. Regarding the roughness measurements, groove depth was lower at the surface of thermally-treated instruments when compared to nontreated instruments (P < 0.05). CONCLUSION: Thermal treatment influenced the torsional resistance and surface roughness of NiTi instruments with identical geometric and dimensional characteristics. Temperature did not affect torsional behaviour.


Subject(s)
Nickel , Titanium , Alloys , Dental Alloys , Equipment Design , Equipment Failure , Hot Temperature , Humans , Materials Testing , Root Canal Preparation , Stress, Mechanical , Torsion, Mechanical
5.
Int Endod J ; 52(12): 1768-1772, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31306497

ABSTRACT

AIM: To compare the martensitic transformation temperatures and torsional resistance behaviour of classic M-Wire Reciproc and Reciproc blue files (VDW, Munich, Germany). METHODOLOGY: M-Wire classic Reciproc R25 and Reciproc blue R25 instruments were used. Transformation temperatures were determined by differential scanning calorimetry (DSC-DSC 60, Shimadzu, Kyoto, Japan). Three samples with approximately 20 mg of each system were cooled to -120 °C and then heated to 100 °C and then cooled to -100 °C at a rate of 10 °C min-1 . The maximum torque values and angular deflection until fracture of new instruments (n = 10) were measured according to ISO 3630-1. Results were analysed statistically using the Student's t-test at a significance level of P < 0.05. RESULTS: DSC results revealed the absence of martensitic transformation for Reciproc instruments in the temperature range analysed. In both systems, the instruments were composed of a mixture of R-phase and austenite at room temperature. After torsional tests, Reciproc blue had significantly lower values for mean maximum torque at rupture (P < 0.05), although the angular deflection values were significantly higher than the Reciproc classic group (P < 0.05). CONCLUSIONS: Both Reciproc and Reciproc blue instruments were composed of a mixture of R-phase and austenite. Reciproc Blue instruments had a greater angle of rotation to fracture but a lower torque to failure than M-Wire Reciproc instruments.


Subject(s)
Dental Instruments , Root Canal Preparation , Equipment Design , Germany , Humans , Materials Testing , Stress, Mechanical , Temperature , Titanium
6.
Int Endod J ; 52(6): 874-879, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30586160

ABSTRACT

AIM: To evaluate the torsional properties of the NiTi glide path reciprocating instruments R-Pilot (VDW, Munich, Germany) and WaveOne Gold Glider (Dentsply Sirona, Ballaigues, Switzerland). METHODOLOGY: Ten R-Pilot (size 12.5, .04 taper) and 10 WaveOne Gold Glider (size 15, .02v taper) instruments were used. The torque and angle of rotation at failure of new instruments (n = 10) were measured according to ISO 3630-1. Three millimetres of each instrument tip was clamped to a small load cell by a lever arm linked to the torsion axis. The fracture surface of all fragments was examined with a scanning electron microscope. Data were analysed using the Student t-test at a significance level of P < 0.05. RESULTS: The maximum torsional strength of the R-Pilot instruments was greater than the WaveOne Gold Glider (P < 0.05). In contrast, WaveOne Gold Glider instruments had significantly higher angular rotation to fracture than R-Pilot instruments (P < 0.05). The scanning electron microscopy of the fracture surfaces revealed similar and typical features of torsional failure (ductile type) for both brands. The torsional failure displayed two zones: the first with microvoids in the centre of the instruments (core) and the second one represented by plastic deformation around the microvoids; this configuration occurred because of the shear stresses originated during the twisting. CONCLUSIONS: R-Pilot instruments had a lower angle of rotation to fracture but a higher torque to failure than WaveOne Gold Glider instruments.


Subject(s)
Dental Instruments , Gold , Equipment Failure Analysis , Germany , Humans , Materials Testing , Root Canal Preparation , Torque , Torsion, Mechanical
7.
Int Endod J ; 52(2): 244-249, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30040121

ABSTRACT

AIM: To determine the distortional angle and torsional load at the pseudoelastic limit of Reciproc Blue instruments and to verify the safety of using pre-set dedicated motors designed for use with the original Reciproc instruments. METHODOLOGY: Two torsional conditions of Reciproc R25 and Reciproc Blue R25 were tested using a custom device. The first condition fixed the file tips at 3 mm and repetitively rotated them, with gradually increasing angles, from 10° to 270°, and the resulting torque was recorded (n = 15). The second test involved a single continuous rotation until fracture (n = 15). The pseudoelastic limits of the instruments were determined from their torque-rotation curves. For statistical analysis, two-way analysis of variance and t-tests were used, at a 95% significance level. Tested specimens were examined using field-emission scanning electron microscopy (FE-SEM). RESULTS: The angle at the pseudoelastic limit was significantly greater for Reciproc Blue than Reciproc, regardless of test mode (P < 0.05). When torsional loading was repeated, using gradually increasing rotational angles, the torsional resistance was significantly lower than for a single rotation (P < 0.05). However, under all test conditions, the pseudoelastic limit was below the pre-set 170° of the dedicated reciprocating motor. FE-SEM evaluation of the lateral aspects of the instruments revealed numerous longitudinal microcracks running along their long axis. For Reciproc Blue groups, the file shaft machining grooves were distorted after repetitive and continuous torsional tests. CONCLUSIONS: The 170° pre-set angle of the dedicated endodontic motors for the Reciproc system was safe for Reciproc Blue in single or time-restricted use.


Subject(s)
Dental Instruments , Equipment Design , Root Canal Preparation/instrumentation , Torsion, Mechanical , Analysis of Variance , Dental Alloys/chemistry , Equipment Failure , Equipment Failure Analysis , Equipment Safety , Humans , Materials Testing , Microscopy, Electron, Scanning , Nickel/chemistry , Rotation , Stress, Mechanical , Surface Properties , Titanium/chemistry , Torque
8.
BMC Oral Health ; 19(1): 124, 2019 06 21.
Article in English | MEDLINE | ID: mdl-31226984

ABSTRACT

BACKGROUND: The aim of this study is to compare the torsional resistance of the available ProTaper rotary systems, namely, ProTaper Universal (PTU), ProTaper Next (PTN), and ProTaper Gold (PTG). METHODS: A total of 195 files from the three systems distributed into 13 groups (PTU-S1, PTU-S2, PTU-F1, PTU-F2, PTU-F3, PTG-S1, PTG-S2, PTG-F1, PTG-F2, PTG-F3, PTN-X1, PTN-X2 and PTN-X3) were subjected to torsional fatigue until failure. The torsional test was performed according to ISO 3630-1, where each file was placed in a straight position to eliminate the influence of cyclic fatigue. The Kruskal-Wallis test was conducted to compare the mean maximum torques and angular deflections at fracture for the groups, and the Mann-Whitney test was performed for pairwise comparisons. The significance level was set at 0.05 and the fractured surfaces were examined under a scanning electron microscope. RESULT: Among the tested files, PTG-S1 had the lowest torsional fatigue resistance, whereas PTU-F2 and PTU-F3 had the highest torsional resistance. The scanning electron microscope showed typical features of torsional failure. CONCLUSION: The new ProTaper systems (PTG and PTN) did not show improved torsional resistance in comparison with PTU.


Subject(s)
Materials Testing , Root Canal Preparation/instrumentation , Equipment Failure , Humans , Microscopy, Electron, Scanning , Nickel , Titanium
9.
Int Endod J ; 51(5): 572-576, 2018 May.
Article in English | MEDLINE | ID: mdl-28700083

ABSTRACT

AIM: To compare the torsional resistance of XP-endo Shaper (XPS; size 30, .01 taper, FKG Dentaire, La Chaux-de-Fonds, Switzerland) instruments at body temperature with TRUShape (TRS; size 30, .06 taper, Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), ProFile Vortex (PV; size 30, .04 taper, Dentsply Tulsa Dental Specialties) and FlexMaster (FM; size 30, .04 taper, VDW GmbH, Munich, Germany) nickel-titanium rotary instruments. METHODOLOGY: A metal block with a square-shaped mould (5 mm × 5 mm × 5 mm) was positioned inside a glass container. Five millimetres of the tip of each instrument was held inside the metal block by filling the mould with a resin composite. The instruments were tested for torsional resistance in saline solution at 37 °C. Data were analysed using one-way analysis of variance (anova) and Tukey post hoc tests. The significance level was set at P < 0.05. RESULTS: FM had the greatest torsional resistance amongst the instruments tested (P < 0.001). There was no significant difference between FM and PV instruments (P = 0.211). The ranking for torsional resistance values was: FM > PV > TRS > XPS. CONCLUSIONS: FlexMaster and ProFile Vortex instruments were more resistant to torsional stress compared with TRUShape and XP-endo Shaper instruments. The manufacturing process used to produce XP-endo Shaper instruments did not enhance their resistance to torsional stress as compared with the other instruments.


Subject(s)
Alloys , Root Canal Obturation/instrumentation , Body Temperature , Equipment Failure , Equipment Failure Analysis , Humans , Microscopy, Electron, Scanning , Torsion, Mechanical
10.
Clin Oral Investig ; 22(7): 2633-2638, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29392414

ABSTRACT

OBJECTIVES: To evaluate the cyclic fatigue using severely curved canals and torsional resistance of ProDesign R (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil), Reciproc Blue (VDW, Munich, Germany), and WaveOne Gold (Dentsply Maillefer, Ballaigues, Switzerland) reciprocating instruments MATERIALS AND METHODS: Twenty instruments of the ProDesign R (25/0.06) system, 20 instruments of the Reciproc Blue (25/0.08v) system, and 20 instrument of the WaveOne Gold (25/0.07v) system were used. Cyclic fatigue resistance was tested measuring the time to fracture and the number of cycles to fracture in an artificial stainless steel severely curved canal with 80° angle and a 3-mm radius of curvature (n = 10). Torque and angle of rotation at failure of new instruments (n = 10) were measured according to ISO 3630-1. The fracture surfaces of all fragments were examined with a scanning electron microscope. Results were statistically analyzed using one-way ANOVA and Tukey's test at a significance level of p < 0.05. RESULTS: ProDesign R instruments showed a significantly longer cyclic fatigue life than the other tested instruments (p < 0.05). Reciproc Blue showed longer cyclic life than WaveOne Gold (p < 0.05). Reciproc Blue showed the higher torsional strength, followed by WaveOne Gold and ProDesign R instruments (p < 0.05). Moreover, Reciproc Blue showed significantly higher angular rotation to fracture than ProDesign R (p < 0.05). WaveOne Gold showed intermediary results regarding angular rotation to fracture with no differences when compared to Reciproc Blue or ProDesign R instruments (p < 0.05). CONCLUSIONS: ProDesign R presented the highest cyclic fatigue resistance in severely curved canals when compared with Reciproc Blue and WaveOne Gold. However, Reciproc Blue showed the higher torsional strength overall and higher angular rotation to fracture when compared to ProDesign R. CLINICAL RELEVANCE: Despite the numerous advantages of reciprocating instruments, these instruments still have some risk of fracture during its use, especially in severely curved canals. The present study evaluated the cyclic fatigue and torsional resistance of thermally treated reciprocating instruments.


Subject(s)
Dental Instruments , Equipment Failure Analysis , Equipment Design , Stress, Mechanical , Surface Properties , Torque
11.
Int Endod J ; 50(11): 1077-1083, 2017 Nov.
Article in English | MEDLINE | ID: mdl-27917513

ABSTRACT

AIM: To compare the torsional and bending resistance of WaveOne Gold (Dentsply Tulsa Dental Specialties, Tulsa, OK, USA), Reciproc (VDW, Munich, Germany) and Twisted File Adaptive (Axis/SybronEndo, Orange, CA, USA) instruments. METHODOLOGY: Torsional strength of WaveOne Gold primary size 25, .07 taper, Reciproc size 25, .08 taper and Twisted File Adaptive M-L1 size 25, .08 taper was measured by fastening the apical 3 mm of the instrument firmly and applying a constant rotation at 2 rpm to the instrument using a torsiometer. The fractured instruments were examined using a scanning electron microscope (SEM). The bending resistance of the instruments was measured using the cantilever bending test. The data were statistically analysed using one-way analysis of variance (anova) and Tukey post hoc tests. The statistical significance level was set at P < 0.05. RESULTS: WaveOne Gold had a significantly higher torsional resistance than Reciproc and Twisted File Adaptive (P < 0.001). Reciproc had a significantly higher torsional resistance than Twisted File Adaptive (P < 0.001). WaveOne Gold had a significantly lower resistance to bend than Reciproc and Twisted File Adaptive (P < 0.001). There was a significant difference in bending resistance between Reciproc and Twisted File Adaptive instruments (P < 0.001). SEM of the fracture cross-sectional surface displayed the classical features of torsional failure, including fibrous dimple marks near the centre of rotation and circular abrasion marks. CONCLUSIONS: WaveOne Gold exhibited higher resistance to torsional stress and flexibility compared with Reciproc and Twisted File Adaptive instruments. Torsional resistance and flexibility properties of the instruments could be affected by the alloy from which the instrument is manufactured and different cross-sectional design.


Subject(s)
Dental Instruments/standards , Analysis of Variance , Torsion, Mechanical
12.
Int Endod J ; 49(11): 1073-1078, 2016 Nov.
Article in English | MEDLINE | ID: mdl-26426295

ABSTRACT

AIM: To evaluate and compare the resistance to cyclic fatigue and torsional stress, flexibility and surface microhardness of ProTaper Gold (PTG; Dentsply, Tulsa Dental Specialties, Tulsa, OK, USA) system with ProTaper Universal (PTU; Dentsply Maillefer, Ballaigues, Switzerland). METHODOLOGY: PTG and PTU instruments were rotated in simulated canals and the number of cycles to failure was recorded to assess their cyclic fatigue resistance. Torsional strength was measured using a torsiometer after fixing firmly the apical 3 mm of the instrument. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of the broken instruments. The instruments were tested for bending resistance using cantilever-bending test. Vickers microhardness was measured on the cross section of instruments with 300 g load and 15 s dwell time. Data were analysed statistically using independent t-tests. Statistical significance was set at P < 0.05. RESULTS: PTG instruments had a significantly higher resistance to cyclic fatigue and flexibility than PTU (P < 0.001). The fractured cross-sectional surfaces revealed typical features of cyclic fractures, including crack origins, fatigue zones and overload fast fracture zones. On the other hand, PTU instruments were associated with higher resistance to torsional stress and microhardness than PTG instruments (P < 0.001). After torsional tests, the fractured cross-sectional surfaces revealed skewed dimples near the centre of the fracture surfaces and circular abrasion streaks. CONCLUSIONS: The PTG instrument had improved resistance to cyclic fatigue and flexibility compared with PTU. PTU instruments had improved resistance to torsional stress and microhardness compared with PTG.


Subject(s)
Dental Equipment , Nickel , Titanium , Equipment Design , Equipment Failure , Materials Testing , Stress, Mechanical , Torsion, Mechanical
13.
Int Endod J ; 48(9): 894-901, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25266920

ABSTRACT

AIM: To assess and compare the resistance to cyclic fatigue, torsional stress, bending and buckling of ProGlider (PG; Dentsply Maillefer, Ballaigues, Switzerland) instruments with PathFile (PF; Dentsply Maillefer) pathfinding nickel-titanium rotary instruments. METHODOLOGY: Size 16, .02 taper PG and PF instruments were rotated in simulated canals until failure, and the number of cycles to failure (NCF) was recorded to evaluate their cyclic fatigue resistance. Torsional strength was measured using a torsiometer after fixing rigidly the apical 5 mm of the instrument. A scanning electron microscope was used to characterize the topographic features of the fracture surfaces of the instruments. The instruments were evaluated for bending resistance using a cantilever-bending test. The buckling resistance was measured by recording the maximum load required to form a lateral elastic displacement along the file axis using a universal testing machine. Data were statistically analysed using independent t-tests. Statistical significance was set at P < 0.05. RESULTS: ProGlider instrument had a significantly higher flexibility, higher resistance to cyclic fatigue and torsional stress than PF instruments (P < 0.05). The fractured cross-sectional surfaces revealed typical features of cyclic fatigue and torsional fractures. There was no significant difference in the maximum load needed to buckle the two instruments tested (P = 0.082). CONCLUSIONS: ProGlider NiTi pathfinding instrument manufactured from M-Wire alloy had enhanced mechanical properties, including higher flexibility, higher resistance to cyclic fatigue and torsional stress compared with PathFile instrument made of conventional NiTi alloy.


Subject(s)
Dental Instruments , Equipment Failure , Materials Testing , Microscopy, Electron, Scanning , Nickel , Stress, Mechanical , Titanium , Torsion, Mechanical
14.
Int Endod J ; 47(3): 290-7, 2014 Mar.
Article in English | MEDLINE | ID: mdl-23815415

ABSTRACT

AIM: To assess and compare the flexibility and torsional resistance of PathFile, RaCe ISO 10 and Scout RaCe instruments in relation to stainless steel K-File hand instruments. METHODOLOGY: Rotary PathFile (sizes 13, 16 and 19; .02 taper), Race ISO 10 (size 10; 0.02, 0.04 and 0.06 tapers), Scout RaCe (sizes 10, 15 and 20; 0.02 taper) and hand K-File (sizes 10, 15 and 20; 0.02 taper) instruments were evaluated. Alloy chemical composition, phases present and transformation temperatures were determined for the NiTi instruments. For all instruments, diameters at each millimetre from the tip as well as cross-sectional areas at 3 mm from the tip were measured based on ANSI/ADA Specification No. 101 using image analysis software. Resistance to bending and torsional resistance were determined according to specification ISO 3630-1. Vickers microhardness measurements were also taken in all instruments to assess their strength. Data were analysed using analysis of variance (α = 0.05). RESULTS: The alloys used in the manufacture of the three types of NiTi instruments had approximately the same chemical composition, but the PathFile instruments had a higher Af transformation temperature and contained a small amount of B19' martensite. All instruments had diameter values within the standard tolerance. The bending and torsional resistance values were significantly increased relative to the instrument diameter and cross-sectional area. CONCLUSIONS: PathFile instruments were the most flexible and the least torque resistant, whilst the stainless steel instruments were the least flexible although they were more torque resistant than the NiTi instruments.


Subject(s)
Dental Instruments , Equipment Failure Analysis , Nickel/chemistry , Root Canal Preparation/instrumentation , Titanium/chemistry , Dental Alloys/chemistry , Equipment Design , Materials Testing , Pliability , Spectrometry, X-Ray Emission , Stainless Steel/chemistry , Torque
15.
Aust Endod J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747371

ABSTRACT

This study assessed the mechanical properties of the Only One File Blue and the Reciproc Blue instruments. A total of 80 new 25 mm reciprocating NiTi instruments (25/.08v) were evaluated for their mechanical performance (n = 40 per group). Cyclic fatigue resistance, torsional fatigue, flexural resistance and buckling resistance tests were conducted. Statistical analysis was employed with a significance level set at 5%. The results indicated no statistically significant differences in resistance to cyclic fatigue neither in the fragment length between the instruments (p > 0.05). However, the Reciproc Blue instrument exhibited greater torque to fracture and a larger rotation angle than the Only One File Blue instrument (p < 0.05). The Only One File Blue instrument demonstrated higher flexibility but lower resistance to buckling compared to the Reciproc Blue instrument (p < 0.05). In conclusion, the tested instruments exhibit differences in mechanical properties, with the Reciproc Blue instrument generally presenting greater advantages than the Only One File Blue.

16.
J Endod ; 50(7): 1011-1016, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38642733

ABSTRACT

INTRODUCTION: The purpose of this study was to evaluate the effect of side flattening of cutting flutes on the cyclic resistance and torsional resistance of nickel-titanium files. METHODS: Both novel flattened Platinum V.EU (PL) and standard nonflattened CC Premium V.EU (CC) rotaries were tested. For cyclic fatigue tests, all the files were rotated in an artificial root canal with a curvature of 45° and a radius of 6.06 mm at 300 rpm (n = 15 in each group). The number of cycles to failure (NCF) was calculated. For torsional tests, the files were rotated at 2 rpm clockwise until fracture occurred. The maximum torque value at fracture was measured and the toughness and distortion angle were computed. Subsequently, 5 fragments were randomly selected in each experiment, the cross-section and longitudinal direction of the fragments were photographed using a scanning electron microscope. An unpaired t-test was performed at a significance level of 95%. RESULTS: There was a statistically significant difference in NCF between CC and PL (P < .05). CC showed higher NCF than PL. There was no statistically significant difference between CC and PL with regards to the parameters related to torsional resistance (distortion angle, ultimate strength, and toughness) (P > .05). CONCLUSION: Within the limitations of this study, side flattening of the file did not improve cyclic resistance or torsional resistance of the files. As side flattening may reduce a file's cyclic resistance, such files should be used with caution in clinical practice.


Subject(s)
Equipment Failure , Nickel , Root Canal Preparation , Titanium , Torsion, Mechanical , Root Canal Preparation/instrumentation , Materials Testing , Equipment Design , Torque , Microscopy, Electron, Scanning , Dental Instruments , Dental Alloys/chemistry
17.
J Endod ; 50(2): 213-219, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37924940

ABSTRACT

INTRODUCTION: The aim of this study was to evaluate the torsional resistance, cyclic fatigue resistance, and bending stiffness of nickel-titanium (NiTi) file systems with different heat treatments and cross-sectional designs. METHODS: WaveOne Primary treated with memory-triple (MT) heat treatment (WOMT) was compared with WaveOne Primary (WO) and WaveOne Gold Primary (WOG). Torsional resistance test was performed using a customized device, and the distortion angle, ultimate strength, and toughness were evaluated. For cyclic fatigue resistance test, the instruments were reciprocated with continuous 4 mm up-and-down movement until fracture in a customized device, and the time to fracture was compared. Fracture surfaces of each group were examined under the scanning electron microscope. Bending stiffness was measured using a custom-made device. The results were analyzed using one-way analysis of variance and the Tukey's post hoc comparison at a significance level of 95%. RESULTS: WOMT showed higher ultimate strength and toughness than the other systems (P < .05). WOMT also showed highest cyclic fatigue resistance among the tested groups (P < .05). WO had the highest bending stiffness than others, whereas WOMT had a larger residual angle than others (P < .05). CONCLUSIONS: This new MT heat treatment technique makes NiTi file more flexible and improves its mechanical properties. In addition, the effect of heat treatment on flexibility was found to be more significant than that of the cross-sectional area.


Subject(s)
Alloys , Hot Temperature , Titanium , Nickel , Dental Instruments , Equipment Design , Root Canal Preparation , Stress, Mechanical , Materials Testing , Torsion, Mechanical
18.
Int Dent J ; 2024 Aug 12.
Article in English | MEDLINE | ID: mdl-39138098

ABSTRACT

OBJECTIVES: This study evaluated the phase composition, phase transformation behaviour, and mechanical properties of five heat-treated NiTi instruments. METHODS: ProTaper NEXT (M-wire, PTN), ProTaper Gold (Gold-wire, PTG), One Curve (C-wire, OC), EdgeTaper Platinum (Fire-wire, ETP), NeoNiTi (electrical discharge machining-wire, NNA), and ProTaper Universal (conventional wire, PTU, control) with #25-tip size were tested (n = 12/group) for cyclic fatigue resistance (number of cycles to failure; NCF) and torsional resistance (angle of rotation to fracture and maximum torque at fracture [ultimate torsional strength]). The geometry and fracture surfaces of the tested instruments were examined by scanning electron microscopy. The phase transformation temperature and phase composition of the instruments were evaluated using differential scanning calorimetry and X-ray diffraction. Data were statistically analysed using one-way ANOVA and Tukey's post hoc test, with the significance level set at 5%. RESULTS: PTG showed the highest NCF (P < .05) at 37°C, while ETP exhibited the highest angle of rotation to fracture, ultimate torsional strength, and stiffness (P < .05). Scanning electron microscopy demonstrated typical clusters of fatigue striations and numerous cracks after cyclic fatigue fracture, whereas there was a concentric abrasion pattern with a dimple and microvoids at the centre after torsional fracture. In differential scanning calorimetry curves, austenite-finishing temperatures of heat-treated instruments were higher than 37°C, whereas that of PTU was lower than 37°C. PTU showed strong peaks of austenite at 25 and 37°C, whereas ETP showed a strong peak of R-phase at 25°C, but mostly austenite phase at 37°C in X-ray diffraction. CONCLUSIONS: Geometry, alloy type, and phase transformation temperatures of NiTi instruments affected their mechanical behaviour. CLINICAL RELEVANCE: PTG showed the highest NCF, suitable for markedly curved canals. ETP had the highest torsional resistance, appropriate for narrow and constricted canals.

19.
Microsc Res Tech ; 86(12): 1635-1641, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37587834

ABSTRACT

This study evaluated the cyclic and torsional fatigue resistance of a new nickel-titanium (Flat File 25.04) instrument on the continuous and reciprocating motion. Sixty instruments of the ProDesign Logic2 25.03 and 25.05 (Easy Equipamentos Odontológicos, Belo Horizonte, Brazil), and MK Flat File 25.04 (n = 20) (MK Life, Porto Alegre, Brazil) were used. For the cyclic fatigue test, an artificial stainless steel simulated canal with an angle of 60° and a radius of curvature of 5 mm located 5 mm from its tip was used. The torque and rotation angle at the instruments' failure on the torsional fatigue test was based on the ISO 3630-1 protocol, in which the 3 mm tip of each instrument was fixed and connected to an electric motor and a load cell. The fractured surface of each fragment was examined by scanning electron microscopy. Data were analyzed using a 1-way analysis of variance and Tukey's test with a significance level of 5%. Flat File 25.04 had lower cyclic fatigue in both kinematics than the Logic instruments (p < .05). Reciprocating motion improved the cyclic fatigue of the tested instruments (p < .05). Flat File 25.04 had similar torque to Logic2 25.05 (p > .05), and both were superior to Logic2 25.03 (p < .05). The angular deflection values were different for the three tested instruments (p < .05), in the decreasing order: Logic2 25.03, 25.05, and Flat File 25.04. Flat File presented good resistance to cyclic and torsional fatigue resistance. Reciprocating motion improved the cyclic fatigue resistance of the instruments and can be considered when using programmable motors. RESEARCH HIGHLIGHTS: Scanning electron microscopy evaluation of different endodontic rotary file and fatigue resistance tests.

20.
Aust Endod J ; 48(1): 121-130, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34670014

ABSTRACT

To compare used and unused Reciproc Blue and Reciproc after retreatment, the instruments were used in the mesiobuccal canals of maxillary molars with curvature. The torsional resistances were tested and then unused instruments were subjected to XRD, DSC and microhardness tests. Student's t, ANOVA and Tukey's tests were performed (α-level 0.05). The torsional strength of used Reciproc Blue was not significantly different than unused ones (P > .05), while torsional strength of Reciproc decreased significantly (P < .05). DSC and XRD indicated that Reciproc Blue exhibited prominent transformation peaks corresponding austenite to R-phase. Microhardness of Reciproc was significantly higher (P < .05). A second reuse of Reciproc Blue for retreatment could be considered safe in terms of torsional strength. Blue treatment also decreased surface microhardness of the instrument and changed phase composition by increasing the R-phase.


Subject(s)
Dental Instruments , Root Canal Preparation , Alloys , Equipment Design , Humans , Materials Testing , Retreatment , Titanium