Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 19.392
Filter
Add more filters

Publication year range
1.
N Engl J Med ; 390(21): 1959-1971, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38587261

ABSTRACT

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Bioprosthesis/adverse effects , Heart Failure , Kaplan-Meier Estimate , Postoperative Complications/etiology , Prosthesis Design , Prosthesis Failure , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects
2.
N Engl J Med ; 390(17): 1572-1583, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38588025

ABSTRACT

BACKGROUND: Among low-risk patients with severe, symptomatic aortic stenosis who are eligible for both transcatheter aortic-valve implantation (TAVI) and surgical aortic-valve replacement (SAVR), data are lacking on the appropriate treatment strategy in routine clinical practice. METHODS: In this randomized noninferiority trial conducted at 38 sites in Germany, we assigned patients with severe aortic stenosis who were at low or intermediate surgical risk to undergo either TAVI or SAVR. Percutaneous- and surgical-valve prostheses were selected according to operator discretion. The primary outcome was a composite of death from any cause or fatal or nonfatal stroke at 1 year. RESULTS: A total of 1414 patients underwent randomization (701 to the TAVI group and 713 to the SAVR group). The mean (±SD) age of the patients was 74±4 years; 57% were men, and the median Society of Thoracic Surgeons risk score was 1.8% (low surgical risk). The Kaplan-Meier estimate of the primary outcome at 1 year was 5.4% in the TAVI group and 10.0% in the SAVR group (hazard ratio for death or stroke, 0.53; 95% confidence interval [CI], 0.35 to 0.79; P<0.001 for noninferiority). The incidence of death from any cause was 2.6% in the TAVI group and 6.2% in the SAVR group (hazard ratio, 0.43; 95% CI, 0.24 to 0.73); the incidence of stroke was 2.9% and 4.7%, respectively (hazard ratio, 0.61; 95% CI, 0.35 to 1.06). Procedural complications occurred in 1.5% and 1.0% of patients in the TAVI and SAVR groups, respectively. CONCLUSIONS: Among patients with severe aortic stenosis at low or intermediate surgical risk, TAVI was noninferior to SAVR with respect to death from any cause or stroke at 1 year. (Funded by the German Center for Cardiovascular Research and the German Heart Foundation; DEDICATE-DZHK6 ClinicalTrials.gov number, NCT03112980.).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Kaplan-Meier Estimate , Stroke/epidemiology , Stroke/etiology , Stroke/mortality , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/mortality , Risk Factors , Germany
3.
N Engl J Med ; 389(21): 1949-1960, 2023 Nov 23.
Article in English | MEDLINE | ID: mdl-37874020

ABSTRACT

BACKGROUND: A previous analysis in this trial showed that among patients with severe, symptomatic aortic stenosis who were at low surgical risk, the rate of the composite end point of death, stroke, or rehospitalization at 1 year was significantly lower with transcatheter aortic-valve replacement (TAVR) than with surgical aortic-valve replacement. Longer-term outcomes are unknown. METHODS: We randomly assigned patients with severe, symptomatic aortic stenosis and low surgical risk to undergo either TAVR or surgery. The first primary end point was a composite of death, stroke, or rehospitalization related to the valve, the procedure, or heart failure. The second primary end point was a hierarchical composite that included death, disabling stroke, nondisabling stroke, and the number of rehospitalization days, analyzed with the use of a win ratio analysis. Clinical, echocardiographic, and health-status outcomes were assessed through 5 years. RESULTS: A total of 1000 patients underwent randomization: 503 patients were assigned to undergo TAVR, and 497 to undergo surgery. A component of the first primary end point occurred in 111 of 496 patients in the TAVR group and in 117 of 454 patients in the surgery group (Kaplan-Meier estimates, 22.8% in the TAVR group and 27.2% in the surgery group; difference, -4.3 percentage points; 95% confidence interval [CI], -9.9 to 1.3; P = 0.07). The win ratio for the second primary end point was 1.17 (95% CI, 0.90 to 1.51; P = 0.25). The Kaplan-Meier estimates for the components of the first primary end point were as follows: death, 10.0% in the TAVR group and 8.2% in the surgery group; stroke, 5.8% and 6.4%, respectively; and rehospitalization, 13.7% and 17.4%. The hemodynamic performance of the valve, assessed according to the mean (±SD) valve gradient, was 12.8±6.5 mm Hg in the TAVR group and 11.7±5.6 mm Hg in the surgery group. Bioprosthetic-valve failure occurred in 3.3% of the patients in the TAVR group and in 3.8% of those in the surgery group. CONCLUSIONS: Among low-risk patients with severe, symptomatic aortic stenosis who underwent TAVR or surgery, there was no significant between-group difference in the two primary composite outcomes. (Funded by Edwards Lifesciences; PARTNER 3 ClinicalTrials.gov number, NCT02675114.).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/mortality , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Postoperative Complications/etiology , Risk Factors , Stroke/epidemiology , Stroke/etiology , Stroke/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Treatment Outcome , Follow-Up Studies , Patient Readmission , Heart Failure/etiology
4.
Circulation ; 150(12): 952-965, 2024 Sep 17.
Article in English | MEDLINE | ID: mdl-38836358

ABSTRACT

BACKGROUND: Whether aortic valve stenosis (AS) can adversely affect systemic endothelial function independently of standard modifiable cardiovascular risk factors is unknown. METHODS: We therefore investigated endothelial and cardiac function in an experimental model of AS mice devoid of standard modifiable cardiovascular risk factors and human cohorts with AS scheduled for transcatheter aortic valve replacement. Endothelial function was determined by flow-mediated dilation using ultrasound. Extracellular hemoglobin (eHb) concentrations and nitric oxide (NO) consumption were determined in blood plasma of mice and humans by ELISA and chemiluminescence. This was complemented by measurements of aortic blood flow using 4-dimensional flow acquisition by magnetic resonance imaging and computational fluid dynamics simulations. The effects of plasma and red blood cell (RBC) suspensions on vascular function were determined in transfer experiments in a murine vasorelaxation bioassay system. RESULTS: In mice, the induction of AS caused systemic endothelial dysfunction. In the presence of normal systolic left ventricular function and mild hypertrophy, the increase in the transvalvular gradient was associated with elevated eryptosis, increased eHb, and increased plasma NO consumption; eHb sequestration by haptoglobin restored endothelial function. Because the aortic valve orifice area in patients with AS decreased, postvalvular mechanical stress in the central ascending aorta increased. This was associated with elevated eHb, circulating RBC-derived microvesicles, eryptotic cells, lower haptoglobin levels without clinically relevant anemia, and consecutive endothelial dysfunction. Transfer experiments demonstrated that reduction of eHb by treatment with haptoglobin or elimination of fluid dynamic stress by transcatheter aortic valve replacement restored endothelial function. In patients with AS and subclinical RBC fragmentation, the remaining circulating RBCs before and after transcatheter aortic valve replacement exhibited intact membrane function, deformability, and resistance to osmotic and hypoxic stress. CONCLUSIONS: AS increases postvalvular swirling blood flow in the central ascending aorta, triggering RBC fragmentation with the accumulation of hemoglobin in the plasma. This increases NO consumption in blood, thereby limiting vascular NO bioavailability. Thus, AS itself promotes systemic endothelial dysfunction independent of other established risk factors. Transcatheter aortic valve replacement is capable of limiting NO scavenging and rescuing endothelial function by realigning postvalvular blood flow to near physiological patterns. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT05603520 and NCT01805739.


Subject(s)
Aortic Valve Stenosis , Endothelium, Vascular , Hemoglobins , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/blood , Aortic Valve Stenosis/metabolism , Animals , Humans , Endothelium, Vascular/metabolism , Endothelium, Vascular/physiopathology , Mice , Hemoglobins/metabolism , Male , Female , Mice, Inbred C57BL , Aged , Transcatheter Aortic Valve Replacement , Nitric Oxide/metabolism , Nitric Oxide/blood , Disease Models, Animal , Aged, 80 and over , Vasodilation
5.
Circulation ; 149(15): 1172-1182, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38410954

ABSTRACT

BACKGROUND: Recent guidelines redefined exercise pulmonary hypertension as a mean pulmonary artery pressure/cardiac output (mPAP/CO) slope >3 mm Hg·L-1·min-1. A peak systolic pulmonary artery pressure >60 mm Hg during exercise has been associated with an increased risk of cardiovascular death, heart failure rehospitalization, and aortic valve replacement in aortic valve stenosis. The prognostic value of the mPAP/CO slope in aortic valve stenosis remains unknown. METHODS: In this prospective cohort study, consecutive patients (n=143; age, 73±11 years) with an aortic valve area ≤1.5 cm2 underwent cardiopulmonary exercise testing with echocardiography. They were subsequently evaluated for the occurrence of cardiovascular events (ie, cardiovascular death, heart failure hospitalization, new-onset atrial fibrillation, and aortic valve replacement) during a follow-up period of 1 year. Findings were externally validated (validation cohort, n=141). RESULTS: One cardiovascular death, 32 aortic valve replacements, 9 new-onset atrial fibrillation episodes, and 4 heart failure hospitalizations occurred in the derivation cohort, whereas 5 cardiovascular deaths, 32 aortic valve replacements, 1 new-onset atrial fibrillation episode, and 10 heart failure hospitalizations were observed in the validation cohort. Peak aortic velocity (odds ratio [OR] per SD, 1.48; P=0.036), indexed left atrial volume (OR per SD, 2.15; P=0.001), E/e' at rest (OR per SD, 1.61; P=0.012), mPAP/CO slope (OR per SD, 2.01; P=0.002), and age-, sex-, and height-based predicted peak exercise oxygen uptake (OR per SD, 0.59; P=0.007) were independently associated with cardiovascular events at 1 year, whereas peak systolic pulmonary artery pressure was not (OR per SD, 1.28; P=0.219). Peak Vo2 (percent) and mPAP/CO slope provided incremental prognostic value in addition to indexed left atrial volume and aortic valve area (P<0.001). These results were confirmed in the validation cohort. CONCLUSIONS: In moderate and severe aortic valve stenosis, mPAP/CO slope and percent-predicted peak Vo2 were independent predictors of cardiovascular events, whereas peak systolic pulmonary artery pressure was not. In addition to aortic valve area and indexed left atrial volume, percent-predicted peak Vo2 and mPAP/CO slope cumulatively improved risk stratification.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Heart Failure , Humans , Middle Aged , Aged , Aged, 80 and over , Prognosis , Echocardiography, Stress/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/complications , Prospective Studies , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Cardiac Output , Heart Failure/complications , Oxygen
6.
Circulation ; 149(9): 644-655, 2024 02 27.
Article in English | MEDLINE | ID: mdl-37883682

ABSTRACT

BACKGROUND: The optimal treatment in patients with severe aortic stenosis and small aortic annulus (SAA) remains to be determined. This study aimed to compare the hemodynamic and clinical outcomes between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR) in patients with a SAA. METHODS: This prospective multicenter international randomized trial was performed in 15 university hospitals. Participants were 151 patients with severe aortic stenosis and SAA (mean diameter <23 mm) randomized (1:1) to TAVR (n=77) versus SAVR (n=74). The primary outcome was impaired valve hemodynamics (ie, severe prosthesis patient mismatch or moderate-severe aortic regurgitation) at 60 days as evaluated by Doppler echocardiography and analyzed in a central echocardiography core laboratory. Clinical events were secondary outcomes. RESULTS: The mean age of the participants was 75.5±5.1 years, with 140 (93%) women, a median Society of Thoracic Surgeons predicted risk of mortality of 2.50% (interquartile range, 1.67%-3.28%), and a median annulus diameter of 21.1 mm (interquartile range, 20.4-22.0 mm). There were no differences between groups in the rate of severe prosthesis patient mismatch (TAVR, 4 [5.6%]; SAVR, 7 [10.3%]; P=0.30) and moderate-severe aortic regurgitation (none in both groups). No differences were found between groups in mortality rate (TAVR, 1 [1.3%]; SAVR, 1 [1.4%]; P=1.00) and stroke (TAVR, 0; SAVR, 2 [2.7%]; P=0.24) at 30 days. After a median follow-up of 2 (interquartile range, 1-4) years, there were no differences between groups in mortality rate (TAVR, 7 [9.1%]; SAVR, 6 [8.1%]; P=0.89), stroke (TAVR, 3 [3.9%]; SAVR, 3 [4.1%]; P=0.95), and cardiac hospitalization (TAVR, 15 [19.5%]; SAVR, 15 [20.3%]; P=0.80). CONCLUSIONS: In patients with severe aortic stenosis and SAA (women in the majority), there was no evidence of superiority of contemporary TAVR versus SAVR in valve hemodynamic results. After a median follow-up of 2 years, there were no differences in clinical outcomes between groups. These findings suggest that the 2 therapies represent a valid alternative for treating patients with severe aortic stenosis and SAA, and treatment selection should likely be individualized according to baseline characteristics, additional anatomical risk factors, and patient preference. However, the results of this study should be interpreted with caution because of the limited sample size leading to an underpowered study, and need to be confirmed in future larger studies. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03383445.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Prospective Studies , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Risk Factors , Stroke/etiology
7.
Circulation ; 149(10): 734-743, 2024 03 05.
Article in English | MEDLINE | ID: mdl-37874908

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is common in patients undergoing transcatheter aortic valve replacement (TAVR) and is associated with increased risk of bleeding and stroke. While left atrial appendage occlusion (LAAO) is approved as an alternative to anticoagulants for stroke prevention in patients with AF, placement of these devices in patients with severe aortic stenosis, or when performed at the same time as TAVR, has not been extensively studied. METHODS: WATCH-TAVR (WATCHMAN for Patients with AF Undergoing TAVR) was a multicenter, randomized trial evaluating the safety and effectiveness of concomitant TAVR and LAAO with WATCHMAN in AF patients. Patients were randomized 1:1 to TAVR + LAAO or TAVR + medical therapy. WATCHMAN patients received anticoagulation for 45 days followed by dual antiplatelet therapy until 6 months. Anticoagulation was per treating physician preference for patients randomized to TAVR + medical therapy. The primary noninferiority end point was all-cause mortality, stroke, and major bleeding at 2 years between the 2 strategies. RESULTS: The study enrolled 349 patients (177 TAVR + LAAO and 172 TAVR + medical therapy) between December 2017 and November 2020 at 34 US centers. The mean age of patients was 81 years, and the mean scores for CHA2DS2-VASc and HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly) were 4.9 and 3.0, respectively. At baseline, 85.4% of patients were taking anticoagulants and 71.3% patients were on antiplatelet therapy. The cohorts were well-balanced for baseline characteristics. The incremental LAAO procedure time was 38 minutes, and the median contrast volume used for combined procedures was 119 mL versus 70 mL with TAVR alone. At the 24-month follow-up, 82.5% compared with 50.8% of patients were on any antiplatelet therapy, and 13.9% compared with 66.7% of patients were on any anticoagulation therapy in TAVR + LAAO compared with TAVR + medical therapy group, respectively. For the composite primary end point, TAVR + LAAO was noninferior to TAVR + medical therapy (22.7 versus 27.3 events per 100 patient-years for TAVR + LAAO and TAVR + medical therapy, respectively; hazard ratio, 0.86 [95% CI, 0.60-1.22]; Pnoninferiority<0.001). CONCLUSIONS: Concomitant WATCHMAN LAAO and TAVR is noninferior to TAVR with medical therapy in severe aortic stenosis patients with AF. The increased complexity and risks of the combined procedure should be considered when concomitant LAAO is viewed as an alternative to medical therapy for patients with AF undergoing TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03173534.


Subject(s)
Aortic Valve Stenosis , Atrial Appendage , Atrial Fibrillation , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Transcatheter Aortic Valve Replacement/adverse effects , Platelet Aggregation Inhibitors/adverse effects , Atrial Appendage/surgery , Stroke/epidemiology , Stroke/etiology , Stroke/prevention & control , Hemorrhage/chemically induced , Anticoagulants/adverse effects , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Treatment Outcome
8.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38795719

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Female , Humans , Male , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Postoperative Complications/epidemiology , Prospective Studies , Prosthesis Design , Severity of Illness Index , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
9.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Article in English | MEDLINE | ID: mdl-38552656

ABSTRACT

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Adolescent , Adult , Aged , Female , Humans , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Prospective Studies , Prosthesis Design , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Article in English | MEDLINE | ID: mdl-36121045

ABSTRACT

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Subject(s)
Aortic Valve Stenosis , Embolic Protection Devices , Intracranial Embolism , Prosthesis Implantation , Stroke , Transcatheter Aortic Valve Replacement , Acute Kidney Injury/etiology , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Delirium/etiology , Humans , Intracranial Embolism/etiology , Intracranial Embolism/prevention & control , Ischemic Attack, Transient/etiology , Prosthesis Implantation/instrumentation , Risk Factors , Stroke/etiology , Stroke/prevention & control , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
11.
Arterioscler Thromb Vasc Biol ; 44(4): e131-e144, 2024 04.
Article in English | MEDLINE | ID: mdl-38357817

ABSTRACT

BACKGROUND: Aortic valve stenosis (AVS) is the most common valvular disease in the developed world. AVS involves the progressive fibrocalcific remodeling of the aortic valve (AV), which impairs function and can ultimately lead to heart failure. Due to gaps in our understanding of the underlying mechanisms of AVS, there are no pharmacological treatments or dietary interventions known to slow AVS progression. Recent studies have begun to suggest oxylipins-a class of bioactive lipids-may be dysregulated in the valves of patients with AVS. METHODS: We utilized high-performance liquid chromatography-tandem mass spectrometry to conduct a targeted oxylipin analysis on human AV tissue and plasma from a cohort of 110 patients undergoing AV surgery. RESULTS: We identified 36 oxylipins in human AV tissue with all showing significant increase in patients with severe AVS. A multivariate model including patient characteristics and valvular oxylipins identified the arachidonic acid-COX (cyclooxygenase) pathway-derived prostanoids to be the most associated with AVS severity. Plasma oxylipin levels were measured in a subset of AV surgery patients and compared with a control group of healthy participants, showing distinct oxylipin profiles between control and disease. CONCLUSIONS: Our comprehensive analysis of oxylipins in the human AV identified the inflammatory and osteogenic regulating prostanoids to be positively correlated with AVS severity. This elucidation of prostanoid dysregulation warrants further research into COX inhibition to mitigate AVS.


Subject(s)
Aortic Valve Stenosis , Oxylipins , Humans , Prostaglandins , Aortic Valve Stenosis/surgery , Aortic Valve/surgery
12.
Arterioscler Thromb Vasc Biol ; 44(2): 513-521, 2024 02.
Article in English | MEDLINE | ID: mdl-38152887

ABSTRACT

BACKGROUND: Leaflet calcification contributes to the development and progression of aortic valve stenosis. Vitamin K activates inhibitors of vascular calcification and may modulate inflammation and skeletal bone loss. Therefore, we aimed to determine whether higher dietary intakes of vitamin K1 are associated with a lower incidence of aortic stenosis. METHODS: In the Danish Diet, Cancer and Health study, participants aged 50 to 64 years completed a 192-item food frequency questionnaire at baseline, from which habitual intakes of vitamin K1 were estimated. Participants were prospectively followed using linkage to nationwide registers to determine incident aortic valve stenosis (primary outcome) and aortic stenosis with subsequent complications (aortic valve replacement, heart failure, or cardiovascular disease-related mortality; secondary outcome). RESULTS: In 55 545 participants who were followed for a maximum of 21.5 years, 1085 were diagnosed with aortic stenosis and 615 were identified as having subsequent complications. Participants in the highest quintile of vitamin K1 intake had a 23% lower risk of aortic stenosis (hazard ratio, 0.77 [95% CI, 0.63-0.94]) and a 27% lower risk of aortic stenosis with subsequent complications (hazard ratio, 0.73 [95% CI, 0.56-0.95]), compared with participants in the lowest quintile after adjusting for demographics and cardiovascular risk factors. CONCLUSIONS: In this study, a high intake of vitamin K1-rich foods was associated with a lower incidence of aortic stenosis and a lower risk of aortic stenosis with subsequent complications.


Subject(s)
Aortic Valve Stenosis , Vitamin K 1 , Humans , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery , Aortic Valve , Vitamin K , Eating , Risk Factors , Vitamin K 2
13.
Eur Heart J ; 45(11): 952-962, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38437633

ABSTRACT

BACKGROUND AND AIMS: The length of stay (LOS) after transcatheter aortic valve implantation (TAVI) remains extremely variable whereas early discharge has been shown to be feasible and safe. The study objective was to evaluate the efficacy and safety of an intervention aimed at reducing LOS after transfemoral TAVI. METHODS: FAST-TAVI II is a prospective, multicentre, cluster, randomized, controlled study including patients with severe symptomatic aortic stenosis, who had transfemoral TAVI. The intervention consisted in a dedicated training programme to implement 10 quality of care measures to reduce LOS with an implementation phase of eight weeks. The primary endpoint was the proportion of patients discharged early within 3 days. Secondary endpoints included: LOS, 30-day mortality and 30-day incidence of readmission for cardiovascular events. RESULTS: During the study period, 969 patients were enrolled in the intervention group and 860 patients in the control group. Mean age was 81.9 ± 6.6 years and mean EuroSCORE II was 4.4 ± 4.5%. Early discharge was achieved in 563 (58.1%) patients in the intervention group vs. 364 (42.3%) patients in the control group (P < .0001). Median LOS was significantly reduced in the intervention group compared to the control group [3 (IQR: 3) vs. 4 days (IQR: 3), P < .0001]. Thirty-day mortality was low and similar in the two groups (0.5% vs. 0.9%, P = .30), as were 30-day readmissions (4.6% vs. 2.8%, P = .28). CONCLUSIONS: The intervention was simple and fast to implement, and was effective and safe to reduce LOS and increase the proportion of patients discharged early after TAVI (NCT04503655).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aged , Aged, 80 and over , Aortic Valve Stenosis/surgery , Length of Stay , Prospective Studies , Patient Discharge , Treatment Outcome , Aortic Valve/surgery , Risk Factors
14.
Eur Heart J ; 45(21): 1904-1916, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38554125

ABSTRACT

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.


Subject(s)
Aortic Valve Stenosis , Benchmarking , Length of Stay , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Male , Female , Aged, 80 and over , Length of Stay/statistics & numerical data , Aged , Critical Pathways , Europe/epidemiology , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Patient Safety
15.
Eur Heart J ; 45(33): 3031-3041, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all [100%; 95% confidence interval (CI) 94%-100.0%, P < .001] patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 [98.3%; 95% CI (91.1%-100%)] patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1%-99.0%). Within 90 days, freedom from mortality was 95% [95% CI (86.1%-99.0%)], without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favourable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/adverse effects , Male , Aged , Prospective Studies , Aortic Valve Stenosis/surgery , Prosthesis Failure , Prosthesis Design , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Treatment Outcome , Coronary Occlusion/surgery , Postoperative Complications/epidemiology
16.
Eur Heart J ; 45(21): 1890-1900, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38270189

ABSTRACT

BACKGROUND AND AIMS: In transcatheter aortic valve replacement (TAVR) recipients, the optimal management of concomitant chronic obstructive coronary artery disease (CAD) remains unknown. Some advocate for pre-TAVR percutaneous coronary intervention, while others manage it expectantly. The aim of this study was to assess the impact of varying degrees and extent of untreated chronic obstructive CAD on TAVR and longer-term outcomes. METHODS: The authors conducted a retrospective cohort study of TAVR recipients from January 2015 to November 2021, separating patients into stable non-obstructive or varying degrees of obstructive CAD. The major outcomes of interest were procedural all-cause mortality and complications, major adverse cardiovascular events, and post-TAVR unplanned coronary revascularization. RESULTS: Of the 1911 patients meeting inclusion, 75%, 6%, 10%, and 9% had non-obstructive, intermediate-risk, high-risk, and extreme-risk CAD, respectively. Procedural complication rates overall were low (death 0.4%, shock 0.1%, extracorporeal membrane oxygenation 0.1%), with no difference across groups. At a median follow-up of 21 months, rates of acute coronary syndrome and unplanned coronary revascularization were 0.7% and 0.5%, respectively, in the non-obstructive population, rising in incidence with increasing severity of CAD (P < .001 for acute coronary syndrome/unplanned coronary revascularization). Multivariable analysis did not yield a significantly greater risk of all-cause mortality or major adverse cardiovascular events across groups. One-year acute coronary syndrome and unplanned coronary revascularization rates in time-to-event analyses were significantly greater in the non-obstructive (98%) vs. obstructive (94%) subsets (Plog-rank< .001). CONCLUSIONS: Transcatheter aortic valve replacement can be performed safely in patients with untreated chronic obstructive CAD, without portending higher procedural complication rates and with relatively low rates of unplanned coronary revascularization and acute coronary syndrome at 1 year.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Postoperative Complications , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Male , Female , Retrospective Studies , Aged, 80 and over , Coronary Artery Disease/surgery , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/mortality , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Aged , Percutaneous Coronary Intervention , Treatment Outcome , Risk Factors
17.
Eur Heart J ; 45(37): 3804-3814, 2024 Oct 05.
Article in English | MEDLINE | ID: mdl-38747246

ABSTRACT

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤75 years of age, including both tricuspid and bicuspid AS. METHODS: The Nordic Aortic Valve Intervention (NOTION)-2 trial enrolled and 1:1 randomized low-risk patients aged ≤75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke, or rehospitalization (related to the procedure, valve, or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group [absolute risk difference 3.1%; 95% confidence interval (CI), -2.7% to 8.8%; hazard ratio (HR) 1.4; 95% CI, 0.7-2.9; P = .3]. Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation, and moderate or greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0; 95% CI, 0.5-2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8; 95% CI, 0.8-18.5) treated with TAVI or surgery, respectively (P for interaction = .1). CONCLUSIONS: Among low-risk patients aged ≤75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at 1 year was similar between TAVI and surgery. Transcatheter aortic valve implantation outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134). TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT02825134.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/mortality , Male , Female , Aged , Bicuspid Aortic Valve Disease/surgery , Bicuspid Aortic Valve Disease/complications , Aortic Valve/surgery , Aortic Valve/abnormalities , Stroke/epidemiology , Stroke/etiology , Heart Valve Diseases/surgery , Heart Valve Diseases/complications , Treatment Outcome , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Patient Readmission/statistics & numerical data , Tricuspid Valve/surgery
18.
Circulation ; 148(16): 1220-1230, 2023 10 17.
Article in English | MEDLINE | ID: mdl-37634187

ABSTRACT

BACKGROUND: Computed tomography (CT) is recommended for guiding transcatheter aortic valve replacement (TAVR). However, a sizable proportion of TAVR candidates have chronic kidney disease, in whom the use of iodinated contrast media is a limitation. Cardiac magnetic resonance imaging (CMR) is a promising alternative, but randomized data comparing the effectiveness of CMR-guided versus CT-guided TAVR are lacking. METHODS: An investigator-initiated, prospective, randomized, open-label, noninferiority trial was conducted at 2 Austrian heart centers. Patients evaluated for TAVR according to the inclusion criteria (severe symptomatic aortic stenosis) and exclusion criteria (contraindication to CMR, CT, or TAVR, a life expectancy <1 year, or chronic kidney disease level 4 or 5) were randomized (1:1) to undergo CMR or CT guiding. The primary outcome was defined according to the Valve Academic Research Consortium-2 definition of implantation success at discharge, including absence of procedural mortality, correct positioning of a single prosthetic valve, and proper prosthetic valve performance. Noninferiority was assessed using a hybrid modified intention-to-treat/per-protocol approach on the basis of an absolute risk difference margin of 9%. RESULTS: Between September 11, 2017, and December 16, 2022, 380 candidates for TAVR were randomized to CMR-guided (191 patients) or CT-guided (189 patients) TAVR planning. Of these, 138 patients (72.3%) in the CMR-guided group and 129 patients (68.3%) in the CT-guided group eventually underwent TAVR (modified intention-to-treat cohort). Of these 267, 19 patients had protocol deviations, resulting in a per-protocol cohort of 248 patients (121 CMR-guided, 127 CT-guided). In the modified intention-to-treat cohort, implantation success was achieved in 129 patients (93.5%) in the CMR group and in 117 patients (90.7%) in the CT group (between-group difference, 2.8% [90% CI, -2.7% to 8.2%]; P<0.01 for noninferiority). In the per-protocol cohort (n=248), the between-group difference was 2.0% (90% CI, -3.8% to 7.8%; P<0.01 for noninferiority). CONCLUSIONS: CMR-guided TAVR was noninferior to CT-guided TAVR in terms of device implantation success. CMR can therefore be considered as an alternative for TAVR planning. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03831087.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Renal Insufficiency, Chronic , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prospective Studies , Treatment Outcome , Tomography, X-Ray Computed , Magnetic Resonance Imaging , Renal Insufficiency, Chronic/surgery , Risk Factors
19.
Clin Infect Dis ; 78(1): 179-187, 2024 01 25.
Article in English | MEDLINE | ID: mdl-37552784

ABSTRACT

BACKGROUND: Scarce data are available comparing infective endocarditis (IE) following surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR). This study aimed to compare the clinical presentation, microbiological profile, management, and outcomes of IE after SAVR versus TAVR. METHODS: Data were collected from the "Infectious Endocarditis after TAVR International" (enrollment from 2005 to 2020) and the "International Collaboration on Endocarditis" (enrollment from 2000 to 2012) registries. Only patients with an IE affecting the aortic valve prosthesis were included. A 1:1 paired matching approach was used to compare patients with TAVR and SAVR. RESULTS: A total of 1688 patients were included. Of them, 602 (35.7%) had a surgical bioprosthesis (SB), 666 (39.5%) a mechanical prosthesis, 70 (4.2%) a homograft, and 350 (20.7%) a transcatheter heart valve. In the SAVR versus TAVR matched population, the rate of new moderate or severe aortic regurgitation was higher in the SB group (43.4% vs 13.5%; P < .001), and fewer vegetations were diagnosed in the SB group (62.5% vs 82%; P < .001). Patients with an SB had a higher rate of perivalvular extension (47.9% vs 27%; P < .001) and Staphylococcus aureus was less common in this group (13.4% vs 22%; P = .033). Despite a higher rate of surgery in patients with SB (44.4% vs 27.3%; P < .001), 1-year mortality was similar (SB: 46.5%; TAVR: 44.8%; log-rank P = .697). CONCLUSIONS: Clinical presentation, type of causative microorganism, and treatment differed between patients with an IE located on SB compared with TAVR. Despite these differences, both groups exhibited high and similar mortality at 1-year follow-up.


Subject(s)
Aortic Valve Stenosis , Endocarditis, Bacterial , Endocarditis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Treatment Outcome , Heart Valve Prosthesis/adverse effects , Endocarditis, Bacterial/epidemiology , Endocarditis, Bacterial/etiology , Endocarditis, Bacterial/surgery , Endocarditis/epidemiology , Endocarditis/etiology , Endocarditis/surgery , Risk Factors
20.
Ann Surg ; 279(5): 891-899, 2024 May 01.
Article in English | MEDLINE | ID: mdl-37753657

ABSTRACT

OBJECTIVE: To associate surgeon-anesthesiologist team familiarity (TF) with cardiac surgery outcomes. BACKGROUND: TF, a measure of repeated team member collaborations, has been associated with improved operative efficiency; however, examination of its relationship to clinical outcomes has been limited. METHODS: This retrospective cohort study included Medicare beneficiaries undergoing coronary artery bypass grafting (CABG), surgical aortic valve replacement (SAVR), or both (CABG+SAVR) between January 1, 2017, and September 30, 2018. TF was defined as the number of shared procedures between the cardiac surgeon and anesthesiologist within 6 months of each operation. Primary outcomes were 30- and 90-day mortality, composite morbidity, and 30-day mortality or composite morbidity, assessed before and after risk adjustment using multivariable logistic regression. RESULTS: The cohort included 113,020 patients (84,397 CABG; 15,939 SAVR; 12,684 CABG+SAVR). Surgeon-anesthesiologist dyads in the highest [31631 patients, TF median (interquartile range)=8 (6, 11)] and lowest [44,307 patients, TF=0 (0, 1)] TF terciles were termed familiar and unfamiliar, respectively. The rates of observed outcomes were lower among familiar versus unfamiliar teams: 30-day mortality (2.8% vs 3.1%, P =0.001), 90-day mortality (4.2% vs 4.5%, P =0.023), composite morbidity (57.4% vs 60.6%, P <0.001), and 30-day mortality or composite morbidity (57.9% vs 61.1%, P <0.001). Familiar teams had lower overall risk-adjusted odds of 30-day mortality or composite morbidity [adjusted odds ratio (aOR) 0.894 (0.868, 0.922), P <0.001], and for SAVR significantly lower 30-day mortality [aOR 0.724 (0.547, 0.959), P =0.024], 90-day mortality [aOR 0.779 (0.620, 0.978), P =0.031], and 30-day mortality or composite morbidity [aOR 0.856 (0.791, 0.927), P <0.001]. CONCLUSIONS: Given its relationship with improved 30-day cardiac surgical outcomes, increasing TF should be considered among strategies to advance patient outcomes.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Aged , United States , Transcatheter Aortic Valve Replacement/methods , Retrospective Studies , Medicare , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL